AEMC SL261 User manual

AC/DC CURRENT
OSCILLOSCOPE PROBE
SL261
ENGLISH User Manual

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 1201.51
Model #: SL261
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
®
INSTRUMENTS
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols................................................3
1.2 DenitionofMeasurementCategories .....................................3
1.3 ReceivingYourShipment..........................................................3
1.4 OrderingInformation.................................................................4
1.4.1 AccessoriesandReplacementParts............................4
2. PRODUCT FEATURES ...................................................................... 5
2.1 Description................................................................................5
2.2 Compatibility .............................................................................5
2.3 Features....................................................................................6
3. SPECIFICATIONS............................................................................. 7
3.1 ElectricalSpecications ............................................................7
3.2 MechanicalSpecications ........................................................8
3.3 EnvironmentalSpecications....................................................9
3.4 SafetySpecications ................................................................9
3.5 TypicalResponseCurves .......................................................10
4. OPERATION .................................................................................. 12
4.1 ZeroAdjustment......................................................................12
4.2 CurrentMeasurement.............................................................12
4.3 Battery Indication (Green LED)...............................................13
4.4 Peak Overload (OL) Indication (Red LED) .............................13
5. MAINTENANCE ............................................................................. 14
5.1 Maintenance ...........................................................................14
5.2 Cleaning..................................................................................14
5.3 ReplacingtheBatteries...........................................................15
RepairandCalibration...........................................................................16
TechnicalandSalesAssistance ............................................................16
Limited Warranty ...................................................................................17
WarrantyRepairs...................................................................................17

2
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 1
INTRODUCTION
WARNING
The safety warnings are provided to ensure the safety of
personnel and proper operation of the instrument. Read the
instruction completely.
• Usecautiononanycircuit:potentiallyhighvoltagesandcurrents
maybepresentandmayposeashockhazard.
• Donotusetheprobeifdamaged.Alwaysconnectthecurrent
probetothemeasuringdevicebeforeitisconnectedaroundthe
conductor
• Donotuseonnoninsulatedconductorwithapotentialtoground
greaterthan600VCATIIIpollution2.Useextremecautionwhen
clampingaroundbareconductorsorbusbars.
• Beforeeachuse,inspecttheprobe;lookforcracksinhousingor
outputcableinsulation.
• Donotuseclampinwetenvironmentorinlocationsthathazard-
ousgasesexist.
• Donotusetheprobeanywherebeyondthetactilebarrier.

AC/DC Current Oscilloscope Probe Model SL261
3
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or rein-
forced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
This symbol refers to a type A current sensor. This symbol signifies that
application around and removal from HAZARDOUS LIVE conductors is per-
mitted.
Probe fitted with an electronic output limiter providing protection against
voltage surges caused by the accidental opening of the probe secondary
circuit to 30V max. peak.
In conformity with WEEE 2002/96/EC.
1.2 Definition of Measurement Categories
CAT II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
CAT III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installationandcircuitbreakers.
CAT IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
with the packing list. Notify your distributor of any missing items. If the
equipmentappearstobedamaged,leaclaimimmediatelywiththecar-
rierandnotifyyourdistributoratonce,givingadetaileddescriptionofany
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.

4
AC/DC Current Oscilloscope Probe Model SL261
1.4 Ordering Information
AC/DCCurrentProbeModelSL261
(10A-100mV/A,100A-10mV/A,BNC).................................. Cat. #1201.51
Includes a user manual.
1.4.1 Accessories and Replacement Parts
Adapter-BNCAdapterforusewithAC/DCCurrentProbe
ModelSL261&Meters8220,8333,8335&8336 .............. Cat. #2140.40

AC/DC Current Oscilloscope Probe Model SL261
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
The SL261 AC/DC Current Oscilloscope Probe expands oscilloscope
applicationsinindustrial,automotiveorpowerenvironments,andisideal
for analysis and measurement of distorted current waveforms and har-
monics.Theprobepermitsaccuratedisplayandmeasurementofcurrents
from100mAto100Arms,DCto100kHzwithoutbreakingintothecircuit.
TheprobeusesHalleecttechnologytomeasureACandDCsignals.The
probeconnectsdirectlytoanoscilloscopethrougha2metercoaxialcable
withaninsulatedBNC.
2.2 Compatibility
TheModelSL261iscompatiblewithanyanalogordigitaloscilloscopeor
othervoltage-measuringinstrumentwhichhasthefollowingfeatures:
• BNCinputconnector
• Rangecapableofdisplaying0.2to0.5Vperdivision
• Minimuminputimpedanceof1MΩ

6
AC/DC Current Oscilloscope Probe Model SL261
2.3 Features
ZERO
OFF
I
Battery
Compartment
Screw
Range Selection Switch
Power Indication LED
Zero Adjust Knob
Current Flow for DC Measurements
or Supply to Load for AC Measurements
Battery
Compartment Cover
Ø = 0.46"
(11.8 mm
)
Peak Overload
Indication LED
Keep hands below
this point
100 mV/A
10 mV/A
WARNING: Always keep hand on the handle part of the probe.

AC/DC Current Oscilloscope Probe Model SL261
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
*Referenceconditions:23°C±5°C,20to75%RH,DCto1kHz,probezeroed,1minute
warmup,batteriesat9V±0.1V,externalmagneticeld<40A/m,noDCcomponent,no
externalcurrentcarryingconductor,1MΩ/100pFload,conductorcenteredinjaw.
Current Range:
100mV/A:100mAto10Apeak
10mV/A:1to100Apeak
Output Signal:1000mVpeakmax
AC Current Accuracy:
Aftercalibrationandforoneyear
(zeroprobebeforemakingmeasurement)
Range Accuracy Phase Shift
100mV/A
(50mA to 10ADC/ACpeak) ±3%ofreading±50mA <1.5°fromDCto65Hz
10mV/A
(500mA to 40ADC/ACpeak) ±4%ofreading±50mA
<1°fromDCto65Hz
10mV/A
(40A to 80ADC/ACpeak) 12%ofreading±50mA
10mV/A
(80A to 100ADC/ACpeak) 15%ofreading
Frequency Range: DCto100kHz(-3dBwithcurrentderating)
Noise:
Range10mV/A:480µV
Range100mV/A:3mV
Slew Rate:
Range10mV/A:20mV/µs
Range100mV/A:0.3V/µs
Load Impedance: >1MΩ/100pF

8
AC/DC Current Oscilloscope Probe Model SL261
Insertion Impedance (50/60 Hz): 100mV/A:3µs
10mV/A:0.01Ω
Rise or Fall Time:Range100mV/A:3µs
Range10mV/A:4µs
Working Voltage: 600Vrmsmax
Common Mode Voltage: 600Vrmsmax
Inuence of Adjacent Conductor: < 0.2mA/A AC
Inuence of Conductor Position in Jaw: 0.5%ofreadingatkHz
Battery: 9Valkaline(NEDA1604A,IEC6LR61)
Low Battery: GreenLEDwhen≥6.5V
Overload Indication:
RedLEDindicatesinputgreaterthantheselectedrange
Typical Consumption: 8.6mA
Battery Life: 55hourstypical
3.2 Mechanical Specifications
Zero Adjustment: 20turnpotentiometer
Maximum Cable Diameter: 0.46" (11.8 mm)
Case Protection: IP20perIEC529
Drop Test:
1.0mon38mmofoakonconcrete;testaccordingtoIEC1010
Mechanical Shock: 100G;testperIEC68-2-27
Vibration:
TestperIEC68-2-6,frequencyrange10Hzto55Hz,amplitude0.15mm
Handle: Lexan®920A,UL94V2
Dimensions: 9.09x1.42x2.64"(231x36x67mm)
Weight: 11.6oz(330g)withbattery
Color: Lightgray
Output Lead: InsulatedcoaxialcablewithinsulatedBNCconnector
Cable Length: 6.5foot(2m)

AC/DC Current Oscilloscope Probe Model SL261
9
3.3 Environmental Specifications
Operating Temperature:0°to50°C(32°to122°F)
Storage Temperature:-30°to80°C(-22°to176°F)
Operating Relative Humidity:
10°to30°C:85±5%RH(withoutcondensation)
40°to50°C:45±5%RH(withoutcondensation)
Inuence of Temperature: <0.2%per°C
Altitude:Non-operating:0to12,000m
Operating:0to2000m
3.4 Safety Specifications
E192383
Electrical:Doubleinsulationorreinforcedinsulationbetweentheprimary
orsecondaryandtheoutercaseofthehandleperEN61010-2-032.
600V,CATIII,PollutionDegree:2
Electromagnetic Compatibility:
EN 50081-1 Class B
EN50082-2ElectrostaticdischargeIEC1000-4-2
Radiated Field IEC 1000-4-3
Fast Transients IEC 1000-4-4
MagneticFieldat50/60HzIEC1000-4-8
*Specications are subject to change without notice

10
AC/DC Current Oscilloscope Probe Model SL261
3.5 Typical Response Curves
0
-1
-2
-3
-4
-5
Frequenc
y
Frequency in Hz
range 100 mV/A
range 10 mV/A
frequency response
measurement current: 1A sine
100 1000 10000 100000
gain in dB
0
-10
-50
-100
-150
Phase Shift
Frequency in Hz
range 100 mV/A
range 10 mV/A
phase graph
measurement current: 1A sine
100 10000 100000
phase in °

AC/DC Current Oscilloscope Probe Model SL261
11
0%
-2%
-4%
-6%
-8%
-10%
-12%
-14%
-16%
0A 20A 40A 60A 80A 100A
Accuracy
Uncertainty
Typical
Specification

12
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 4
OPERATION
4.1 Zero Adjustment
Theprobehasazeroadjustmentthatshouldbeadjustedbeforemeasure-
ment.Alternatively,youmay“zero”withtheoscilloscopeinstead.
4.2 Current Measurement
WARNING: Always connect the probe to the instrument before clamping onto
the circuit under test.
• ConnecttheModelSL261totheproperinputchannelontheoscil-
loscope.
•
Beginwiththeleastsensitiverangeonthecurrentprobe(10mV/A)
• Selectthe0.5V/Divisionrangeontheoscilloscope.
• Clamptheprobeontheconductortobemeasuredandreadthe
currentowingdirectlyonyouroscilloscope.
(Remember to unclamp the probe from the conductor before discon-
necting it from your meter or instrument.)
Youmayalsouseyouroscilloscopetoamplifythesignalwhileusingthe
100mV/A probe range (which oers the best accuracy and least phase
shift).
NOTE: It is possible to change the range on the current probe without remov-
ing the probe from the current carrying conductor, but it is important to
remember not to exceed the permissible peak ratings of 1000mV peak or
2000mV peak to peak maximum. The peak ratings by range are: 10A peak
on the 100mV/A range, 100A peak on the 10mV/A range.

AC/DC Current Oscilloscope Probe Model SL261
13
4.3 Battery Indication (Green LED)
TheprobehasabatteryconditionLED.Toensureproperreadingswith
yourcurrentprobe,besurethatthegreenLEDislitduringmeasurement.
Ifnot,replacethe9Vbattery.
4.4 Peak Overload (OL) Indication (Red LED)
TheSL261oersanoverloadindicator.IftheredLEDilluminatesduring
measurement,thisindicatesthatthepeakvalueexceedstheinstrument
responselevelandthattheoutputisdistorted.Switchtheprobetoahigher
rangeifpossible.

14
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 5
MAINTENANCE
5.1 Maintenance
WARNING
• Toensureoptimumperformance,itisimportanttokeeptheprobe
jawmatingsurfacescleanatalltimes.Failuretodosomayresult
inerrorinreadings.
• Formaintenanceuseonlyspeciedfactoryreplacementparts.
• Toavoidelectricalshock,donotattempttoperformanyservicing
unlessyouarequaliedtodoso.
• Toavoidelectricalshockand/ordamagetotheinstrument,donot
allowwaterorotherforeignsubstancesintothecase.
• Disconnecttheunitfromallcircuitsandtestcablesbeforeopen-
ingthecase.
5.2 Cleaning
• Tocleantheprobebody,useasoftclothdampenedinasolution
ofmilddetergentandwater.Tocleanthecore,openthejawand
cleantheexposedcoresurfaceswithacottonswabdampened
with isopropyl alcohol (isopropanol) or ethyl alcohol (fotocol or
ethanol).Lubricatethejawsmatingsurfaceswithalightoil.
• Do not use chemicals containing benzine, benzene, toluene,
xylene,acetone,orsimilarsolvents.
• Donotimmersetheprobeinliquidsoruseabrasivecleaners.

AC/DC Current Oscilloscope Probe Model SL261
15
5.3 Replacing the Batteries
CAUTION: Risk of electric shock. Disconnect all input(s) from the unit or
remove the probe from any conductor before opening the battery cover to
change the batteries.
Ifthe greenbattery indication LEDdoes notlight up when the probeis
turnedon,thebatterieswillneedtobereplaced.
Donotreplacethebatterywhileprobeisinuse.
Toreplacethebattery:
• Disconnecttheprobefromthecircuitandtheoscilloscope.
• Turntheprobe“OFF”.
• Unscrewthebatterycompartmentscrewandpulloutthebatterycom-
partmentcover.
• Replacethebatteryandputthecoverbackon.

16
AC/DC Current Oscilloscope Probe Model SL261
Repair and Calibration
Toensurethatyourinstrumentmeetsfactoryspecications,werecommend
thatitbescheduledbacktoourfactoryServiceCenteratone-yearintervals
forrecalibration,orasrequiredbyotherstandardsorinternalprocedures.
For instrument repair and calibration:
You must contact our Service Center for a Customer ServiceAuthorization
Number(CSA#).Thiswillensurethatwhenyourinstrumentarrives,itwillbe
trackedandprocessedpromptly.PleasewritetheCSA#ontheoutsideofthe
shipping container. If the instrument is returned for calibration, we need to
knowifyouwantastandardcalibration,oracalibrationtraceabletoN.I.S.T.
(Includescalibrationcerticateplusrecordedcalibrationdata).
Ship To: ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments
15 Faraday Drive
Dover,NH03820USA
Phone:(800)945-2362(Ext.360)
(603)749-6434(Ext.360)
Fax: (603)742-2346or(603)749-6309
E-mail:[email protected]
(Orcontactyourauthorizeddistributor)
Costsforrepair,standardcalibration,andcalibrationtraceabletoN.I.S.T.are
available.
NOTE: You must obtain a CSA# before returning any instrument.
Technical and Sales Assistance
Ifyouareexperiencinganytechnicalproblems,orrequireanyassistancewith
theproperoperationorapplicationofyourinstrument,pleasecall,mail,faxor
e-mailourtechnicalsupportteam:
ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments
200FoxboroughBoulevard
Foxborough,MA02035USA
Phone:(800)343-1391
(508) 698-2115
Fax: (508)698-2118
E-mail:[email protected]
www.aemc.com
NOTE: Do not ship Instruments to our Foxborough, MA address.

AC/DC Current Oscilloscope Probe Model SL261
17
Limited Warranty
The AC/DC Current Oscilloscope Probe Model SL261 is warranted to the
owner for a period of two years from the date of original purchase against
defectsinmanufacture.ThislimitedwarrantyisgivenbyAEMC®Instruments,
notbythedistributorfromwhomitwaspurchased.Thiswarrantyisvoidifthe
unithasbeentamperedwith,abusedorifthedefectisrelatedtoservicenot
performedbyAEMC®Instruments.
Full warranty coverage and product registration is available on our
website at www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.
What AEMC®Instruments will do:
Ifamalfunctionoccurswithinthewarrantyperiod,youmayreturntheinstrument
tousforrepair,providedwehaveyourwarrantyregistrationinformationonle
oraproofofpurchase.AEMC®Instrumentswill,atitsoption,repairorreplace
thefaultymaterial.
REGISTER ONLINE AT:
www.aemc.com
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
First, request a Customer ServiceAuthorization Number (CSA#) by phone
orbyfaxfromourServiceDepartment(seeaddressbelow),thenreturnthe
instrumentalongwith the signed CSAForm.Pleasewrite the CSA# on the
outsideoftheshippingcontainer.Returntheinstrument,postageorshipment
pre-paidto:
Ship To: ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments
15FaradayDrive•Dover,NH03820USA
Phone:(800)945-2362(Ext.360)
(603)749-6434(Ext.360)
Fax: (603)742-2346or(603)749-6309
E-mail:[email protected]
Caution:Toprotectyourselfagainstin-transitloss,werecommendyouinsure
yourreturnedmaterial.
NOTE: You must obtain a CSA# before returning any instrument.

04/17
99-MAN100042v16
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
15FaradayDrive•Dover,NH03820USA•Phone:(603)749-6434•Fax:(603)742-2346
www.aemc.com
Other manuals for SL261
4
Table of contents
Other AEMC Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Purafil
Purafil ONGuard 4000 quick start guide

GAGEMAKER
GAGEMAKER MIC TRAC MT-3000 Operation manual

G.R.A.S.
G.R.A.S. 50AI instruction manual

Adam Pumps
Adam Pumps BENZ FLOW Installation, use and maintenance guide

Shark
Shark 100B quick start guide

Gossen MetraWatt
Gossen MetraWatt METRAPHASE 1 operating instructions