AEMC SL261 User manual

AC/DC CURRENT
OSCILLOSCOPE PROBE
SL261
E N G L I S H User Manual
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

________________________________
Catalog #: 1201.51
Model #: SL261
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

Table of Contents
INTRODUCTION ..................................................................................... 2
1.1 International Electrical Symbols................................................3
1.2DenitionofMeasurementCategories .....................................3
1.3ReceivingYourShipment..........................................................3
1.4OrderingInformation.................................................................4
1.4.1AccessoriesandReplacementParts............................4
PRODUCT FEATURES............................................................................. 5
2.1Description................................................................................5
2.2Compatibility .............................................................................5
2.3Features....................................................................................6
SPECIFICATIONS................................................................................... 7
3.1ElectricalSpecications ............................................................7
3.2MechanicalSpecications ........................................................8
3.3EnvironmentalSpecications....................................................9
3.4SafetySpecications ................................................................9
3.5TypicalResponseCurves .......................................................10
OPERATION......................................................................................... 12
4.1ZeroAdjustment......................................................................12
4.2CurrentMeasurement.............................................................12
4.3 Battery Indication (Green LED)...............................................13
4.4 Peak Overload (OL) Indication (Red LED) .............................13
MAINTENANCE ................................................................................... 14
5.1Maintenance ...........................................................................14
5.2Cleaning..................................................................................14
5.3ReplacingtheBatteries...........................................................15
RepairandCalibration ..........................................................................16
TechnicalandSalesAssistance ............................................................16
Limited Warranty...........................................................................................17
WarrantyRepairs ..................................................................................17
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

2
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 1
INTRODUCTION
WARNING
The safety warnings are provided to ensure the safety of
personnel and proper operation of the instrument. Read the
instruction completely.
•Usecautiononanycircuit:potentiallyhighvoltagesandcurrents
maybepresentandmayposeashockhazard.
•Donotusetheprobeifdamaged.Alwaysconnectthecurrent
probetothemeasuringdevicebeforeitisconnectedaroundthe
conductor
•Donotuseonnoninsulatedconductorwithapotentialtoground
greaterthan600VCATIIIpollution2.Useextremecautionwhen
clampingaroundbareconductorsorbusbars.
•Beforeeachuse,inspecttheprobe;lookforcracksinhousingor
outputcableinsulation.
•
Donotuseclampinwetenvironmentorinlocationsthathazardous
gasesexist.
•Donotusetheprobeanywherebeyondthetactilebarrier.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
3
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or
reinforced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
This symbol refers to a type A current sensor. This symbol signifies that
application around and removal from HAZARDOUS LIVE conductors is
permitted.
Probe fitted with an electronic output limiter providing protection against
voltage surges caused by the accidental opening of the probe secondary
circuit to 30V max. peak.
In conformity with WEEE 2002/96/EC.
1.2 Definition of Measurement Categories
CAT II: Formeasurementsperformedoncircuitsdirectlyconnectedto
theelectricaldistributionsystem.Examplesaremeasurements
onhouseholdappliancesorportabletools.
CAT III:Formeasurementsperformedinthebuildinginstallationat
thedistributionlevelsuchasonhardwiredequipmentin xed
installationandcircuitbreakers.
CAT IV: Formeasurementsperformedattheprimaryelectricalsupply
(<1000V)suchasonprimaryovercurrentprotectiondevices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
withthepackinglist.Notifyyourdistributorofanymissingitems.Ifthe
equipmentappearstobedamaged,leaclaimimmediatelywiththecar
rier
andnotifyyourdistributoratonce,givingadetaileddescriptionofany
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

4
AC/DC Current Oscilloscope Probe Model SL261
1.4 Ordering Information
AC/DCCurrentProbeModelSL261
(10A-100mV/A,100A-10mV/A,BNC)..................................Cat. #1201.51
Includes a user manual.
1.4.1 Accessories and Replacement Parts
Adapter-BNCAdapterforusewithAC/DCCurrentProbe
ModelSL261&Meters8220,8333,8335&8336 .............. Cat. #2140.40
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheSL261AC/DCCurrentOscilloscopeProbeexpandsoscilloscope
applicationsinindustrial,automotiveorpowerenvironments,andis
idealforanalysisandmeasurementofdistortedcurrentwaveformsand
harmonics.Theprobepermitsaccuratedisplayandmeasurementof
currentsfrom100mAto100Arms,DCto100kHzwithoutbreakinginto
thecircuit.The probeusesHalleecttechnologytomeasureACandDC
signals.Theprobeconnectsdirectlytoanoscilloscopethrougha2meter
coaxialcablewithaninsulatedBNC.
2.2 Compatibility
TheModelSL261iscompatiblewithanyanalogordigitaloscilloscopeor
othervoltage-measuringinstrumentwhichhasthefollowingfeatures:
•BNCinputconnector
•Rangecapableofdisplaying0.2to0.5Vperdivision
•Minimuminputimpedanceof1MΩ
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

6
AC/DC Current Oscilloscope Probe Model SL261
2.3 Features
ZERO
OFF
I
Battery
Compartment
Screw
Range Selection Switch
Power Indication LED
Zero Adjust Knob
Current Flow for DC Measurements
or Supply to Load for AC Measurements
Battery
Compartment Cover
Ø = 0.46"
(11.8 mm)
Peak Overload
Indication LED
Keep hands below
this point
100 mV/A
10 mV/A
WARNING: Always keep hand on the handle part of the probe.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
*Referenceconditions:23°C±5°C,20to75%RH,DCto1kHz,probezeroed,1
minutewarmup,batteriesat9V±0.1V,externalmagneticeld<40A/m,noDC
component,noexternalcurrentcarryingconductor,1MΩ/100pFload,conductor
centeredinjaw.
Current Range:
100mV/A:100mAto10Apeak
10mV/A:1to100Apeak
Output Signal:1000mVpeakmax
AC Current Accuracy:
Aftercalibrationandforoneyear
(zeroprobebeforemakingmeasurement)
Range Accuracy Phase Shift
100mV/A
(50mA to 10ADC/ACpeak) ±3%ofreading±50mA <1.5°fromDCto65Hz
10mV/A
(500mA to 40ADC/ACpeak) ±4%ofreading±50mA
<1°fromDCto65Hz
10mV/A
(40A to 80ADC/ACpeak) 12%ofreading±50mA
10mV/A
(80A to 100ADC/ACpeak) 15%ofreading
Frequency Range: DCto100kHz(-3dBwithcurrentderating)
Noise:
Range10mV/A:480µV
Range100mV/A:3mV
Slew Rate:
Range10mV/A:20mV/µs
Range100mV/A:0.3V/µs
Load Impedance: >1MΩ/100pF
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

8
AC/DC Current Oscilloscope Probe Model SL261
Insertion Impedance (50/60 Hz): 100mV/A:3µs
10mV/A:0.01Ω
Rise or Fall Time:Range100mV/A:3µs
Range10mV/A:4µs
Working Voltage: 600Vrmsmax
Common Mode Voltage: 600Vrmsmax
Inuence of Adjacent Conductor: < 0.2mA/A AC
Inuence of Conductor Position in Jaw: 0.5%ofreadingatkHz
Battery: 9Valkaline(NEDA1604A,IEC6LR61)
Low Battery: GreenLEDwhen≥6.5V
Overload Indication:
RedLEDindicatesinputgreaterthantheselectedrange
Typical Consumption: 8.6mA
Battery Life: 55hourstypical
3.2 Mechanical Specifications
Zero Adjustment: 20turnpotentiometer
Maximum Cable Diameter: 0.46" (11.8 mm)
Case Protection: IP20perIEC529
Drop Test:
1.0mon38mmofoakonconcrete;testaccordingtoIEC1010
Mechanical Shock: 100G;testperIEC68-2-27
Vibration:
TestperIEC68-2-6,frequencyrange10Hzto55Hz,amplitude0.15mm
Handle: Lexan®920A,UL94V2
Dimensions: 9.09x1.42x2.64"(231x36x67mm)
Weight: 11.6oz(330g)withbattery
Color: Lightgray
Output Lead: InsulatedcoaxialcablewithinsulatedBNCconnector
Cable Length: 6.5foot(2m)
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
9
3.3 Environmental Specifications
Operating Temperature:0°to50°C(32°to122°F)
Storage Temperature:-30°to80°C(-22°to176°F)
Operating Relative Humidity:
10°to30°C:85±5%RH(withoutcondensation)
40°to50°C:45±5%RH(withoutcondensation)
Inuence of Temperature: <0.2%per°C
Altitude:Non-operating:0to12,000m
Operating:0to2000m
3.4 Safety Specifications
E192383
Electrical:Doubleinsulationorreinforcedinsulationbetweentheprimary
orsecondaryandtheoutercaseofthehandle perEN61010-2-032.
600V,CATIII,PollutionDegree:2
Electromagnetic Compatibility:
EN 50081-1 Class B
EN50082-2ElectrostaticdischargeIEC1000-4-2
Radiated Field IEC 1000-4-3
Fast Transients IEC 1000-4-4
MagneticFieldat50/60HzIEC1000-4-8
*Specications are subject to change without notice
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

10
AC/DC Current Oscilloscope Probe Model SL261
3.5 Typical Response Curves
0
-1
-2
-3
-4
-5
Frequency
Frequency in Hz
range 100 mV/A
range 10 mV/A
frequency response
measurement current: 1A sine
100 1000 10000 100000
gain in dB
0
-10
-50
-100
-150
Phase Shift
Frequency in Hz
range 100 mV/A
range 10 mV/A
phase graph
measurement current: 1A sine
100 10000 100000
phase in °
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
11
0%
-2%
-4%
-6%
-8%
-10%
-12%
-14%
-16%
0A 20A 40A 60A 80A 100A
Accurac
y
Uncertainty
Typical
Specification
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

12
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 4
OPERATION
4.1 Zero Adjustment
Theprobehasazeroadjustmentthatshouldbeadjustedbefore
measurement.Alternatively,youmay“zero”withtheoscilloscopeinstead.
4.2 Current Measurement
WARNING: Always connect the probe to the instrument before clamping onto
the circuit under test.
•ConnecttheModelSL261totheproperinputchannelonthe
oscilloscope.
•
Beginwiththeleastsensitiverangeonthecurrentprobe(10mV/A).
•Selectthe0.5V/Divisionrangeontheoscilloscope.
•Clamptheprobeontheconductortobemeasuredandreadthe
currentowingdirectlyonyouroscilloscope.
(Remember to unclamp the probe from the conductor before
disconnecting it from your meter or instrument.)
Youmayalsouseyouroscilloscopetoamplifythesignalwhileusingthe
100mV/Aproberange(whichoersthebestaccuracyandleastphase
shift).
NOTE: It is possible to change the range on the current probe without removing
the probe from the current carrying conductor, but it is important to remember
not to exceed the permissible peak ratings of 1000mV peak or 2000mV peak
to peak maximum. The peak ratings by range are: 10A peak on the 100mV/A
range, 100A peak on the 10mV/A range.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
13
4.3 Battery Indication (Green LED)
TheprobehasabatteryconditionLED.Toensureproperreadingswith
yourcurrentprobe,besurethatthegreenLEDislitduringmeasurement.
Ifnot,replacethe9Vbattery.
4.4 Peak Overload (OL) Indication (Red LED)
TheSL261oersanoverloadindicator.IftheredLEDilluminatesduring
measurement,thisindicatesthat thepeakvalueexceedstheinstrument
responselevelandthattheoutputisdistorted.Switchtheprobetoahigher
rangeifpossible.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

14
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 5
MAINTENANCE
5.1 Maintenance
WARNING
• Toensureoptimumperformance,itisimportanttokeeptheprobe
jaw matingsurfacescleanatalltimes.Failuretodo somayresult
inerrorinreadings.
•For maintenanceuseonlyspeciedfactoryreplacementparts.
•Toavoidelectricalshock,donotattempttoperformanyservicing
unlessyouarequaliedtodoso.
• Toavoidelectricalshockand/ordamagetotheinstrument,donot
allowwaterorotherforeignsubstancesintothecase.
•Disconnecttheunitfromallcircuitsandtestcablesbeforeopen-
ingthecase.
5.2 Cleaning
•Tocleantheprobebody,useasoftclothdampenedinasolution
ofmilddetergentandwater.Tocleanthecore,openthejawand
cleantheexposedcoresurfaceswithacottonswabdampened
withisopropylalcohol(isopropanol)orethylalcohol(fotocolor
ethanol).Lubricatethejawsmatingsurfaceswithalightoil.
•Donotusechemicalscontainingbenzine,benzene,toluene,
xylene,acetone,orsimilarsolvents.
•Donotimmersetheprobeinliquidsoruseabrasivecleaners.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
15
5.3 Replacing the Batteries
CAUTION: Risk of electric shock. Disconnect all input(s) from the unit or
remove the probe from any conductor before opening the battery cover to
change the batteries.
IfthegreenbatteryindicationLEDdoesnotlightupwhentheprobeis
turnedon,thebatterieswillneedtobereplaced.
Donotreplacethebatterywhileprobeisinuse.
Toreplacethebattery:
•Disconnecttheprobefromthecircuitandthe oscilloscope.
•Turntheprobe“OFF”.
•Unscrewthebatterycompartmentscrewandpulloutthebattery
compartmentcover.
•Replacethebatteryandputthecoverbackon.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

16
AC/DC Current Oscilloscope Probe Model SL261
Repair and Calibration
Toensurethatyourinstrumentmeetsfactoryspecications,werecommend
thatitbescheduledbacktoourfactoryServiceCenteratone-yearintervals
forrecalibration,orasrequiredbyotherstandardsorinternalprocedures.
For instrument repair and calibration:
YoumustcontactourServiceCenterforaCustomerServiceAuthorization
Number(CSA#).Thiswillensurethatwhenyourinstrumentarrives,itwillbe
trackedandprocessedpromptly.PleasewritetheCSA#ontheoutsideofthe
shippingcontainer.Iftheinstrumentisreturnedforcalibration,weneedto
knowifyouwantastandardcalibration,oracalibrationtraceabletoN.I.S.T.
(Includescalibrationcerticateplusrecordedcalibrationdata).
forrepair,standardcalibration, andcalibrationtraceabletoN.I.S.T.are
available.
NOTE: You must obtain a CSA# before returning any instrument.
Technical and Sales Assistance
Ifyouareexperiencinganytechnicalproblems,orrequireanyassistance
withtheproperoperationorapplicationofyourinstrument,pleasecall,faxor
e-mailourtechnicalsupport
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
17
Limited Warranty
TheAC/DCCurrentOscilloscopeProbeModelSL261iswarrantedtothe
ownerforaperiodoftwoyearsfromthedateoforiginalpurchaseagainst
defectsinmanufacture.ThislimitedwarrantyisgivenbyAEMC®Instruments,
notbythedistributorfromwhomitwaspurchased.Thiswarrantyisvoidifthe
unithasbeentamperedwith,abusedorifthe defectisrelatedtoservicenot
performedbyAEMC®Instruments.
amalfunctionoccurswithinthewarrantyperiod,youmayreturntheinstrument
tousforrepair,providedwehaveyourwarrantyregistrationinformationonle
oraproofofpurchase.AEMC®Instrumentswill,atitsoption,repairorreplace
thefaultymaterial.
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
First,requestaCustomerServiceAuthorizationNumber(CSA#)byphone
orbyfaxfromourServiceDepartment(seeaddressbelow),thenreturnthe
instrumentalongwiththesignedCSAForm.PleasewritetheCSA#onthe
outsideoftheshippingcontainer.Returntheinstrument,postageorshipment
pre-paid
Toprotectyourselfagainstin-transitloss,werecommendyouinsure
yourreturnedmaterial.
NOTE: You must obtain a CSA# before returning any instrument.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

10/21
99-MAN100042
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com
Other manuals for SL261
4
Table of contents
Other AEMC Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

PCB Piezotronics
PCB Piezotronics P356A71 Installation and operating manual

L&T Electrical & Automation
L&T Electrical & Automation 1 Phase DIN Rail Meter user manual

KROHNE
KROHNE IFC 050 quick start

Lutron Electronics
Lutron Electronics DW-6064 Operation manual

Master Meter
Master Meter Madness PD Assembly instructions

socomec
socomec COUNTIS E43 instruction manual