AERTECNICA TUBO PERFETTO INOX TXA User manual

PERFETTO INOX TXA
PERFETTO TPA
PERFETTO TP
CLASSIC TC
Central power unit

Index
GeneRAL InFORMATIOn
3 General warnings
3 Warranty
4 Safety
4 Certifications
4 Identification
4 Manufacturer
5 Identification plate
5 TUBÒ system description
6 Part description
7 Technical features
8 Foreseen use
8 Prohibited uses
8 Unauthorised uses
8 Operator
8 Starting/stopping
9 Built-in vacuum socket
9 Wireless kit
InSTALLATIOn
10 Opening the packaging
10 Handling the packaging
10 Installation location
11 Central power unit installation
allowances
12 Bracket fastening
13 Dust inlet line connection
13 Exhaust conveyor line connection
14 Connection of the exhaust line to the
ambient atmosphere
14 Air discharge grills
14 Electric motor air intakes
15 TUBÒ System electrical connection
16 Control panel with
AVI display and keyboard
17 Control panel operation with
AVI display
19 AVT control panel
19 AVT control panel functioning
20 Central power unit inspection
MAInTenAnCe
21
Maintenance of Perfetto TXA - TPA - TP
central power units
21 Container emptying
22 Clean Bag insertion
23 Filter cartridge replacement
24 Classic TC central
power unit maintenance
24 Container emptying
24 Filter cartridge replacement
26 Filter cartridge regeneration
27 Central power unit disposal
28 Anomaly and lock table
(Perfetto TXA,
TPA and TP central power units)
30 Troubleshooting
(Perfetto TXA, TPA
and TP central power units)
31 Anomaly and lock table
(Classic TC central power unit)
32 Troubleshooting (Classic TC central
power units)

english
General warninGs
Carefully read the manual
The installation, user and maintenance manual is an
integral and essential part of the central power unit
and must be read carefully as it contains important
information concerning operator safety, foreseen
operation and the correct maintenance of the central
power unit.
Keep the manual in a safe place
It is recommended to store the user manual in the
multifunction pocket (in all PERFETTO TXA, TPA - TP
models excluding models TX1A, TP1A , TP1 and the
CLASSIC TC series).
warranty
Warranty terms within the European Union
Aertecnica guarantees the proper operation of the
purchased central power unit for a 24 month period
starting from the documented purchase date.
If there is not any documentation that proves the
purchase date (invoice or fiscal receipt), the 24 month
period will refer to the date it was sold by AERTECNICA.
The warranty conditions are those provided by current
European legislation and in any case the following are
not covered by the warranty:
Faults, damage or breakage caused by incorrect electric
connection during or after installation
Faults, damage or breakage caused by the malfunctioning
of other components in the system, e.g., vacuum
sockets, if these components are not from AERTECNICA.
Faults, damage or breakage caused by pipe clogging.
Damage or breakages owing to carelessness, negligence,
inability or associated with prohibited or unauthorised
uses.
Materials, components and accessories, including
electric and electronic ones, when the damage is not
related to original manufacturing defects or when the
damage is due to component wear.
The manufacturer shall not accept any contractual and
extra contractual liability due to damage caused by errors in
using and installing the central power unit or due to failure
to observe the instructions provided by the manufacturer.
The warranty will lapse in the case of tampering, repairs
carried out by unauthorised individuals.
Aertecnica declines all liability concerning decreased
performance or damage to the central power unit due
to the use of non-original spare parts.
Other additional warranty conditions will only and
exclusively be the responsibility of the party proposing
them.
For all disputes, the court of Forlì-Cesena (Italy) shall have
exclusive jurisdiction and Italian legislation shall apply.
Warranty terms outside the European Union
For countries that are not part of the European Union,
the warranty shall be the responsibility of the importing
company and the warranty conditions shall be those
foreseen by the applicable regulations in the country
of import.
This manual is printed on 100% recycled
paper
NOTE
Aertecnica reserves the right to modify the product
and the related technical documentation without
incurring any obligation to third parties.
No part of this manual may be reproduced, copied
or distributed in any manner without written
authorisation from Aertecnica.
3

english
safety
The operator must accurately respect the following
operating instructions in order to guarantee the safety
of persons and the functioning of the central power
unit.
HAZARD: this indicates that attention must be
paid in order to prevent events that could cause
serious accidents that harm people or their health.
HAZARDS OF AN ELECTRIC NATURE: make sure
that the central power unit is connected with the
relative cable to a standard compliant earthing
system.
The power supply and relative socket must be
suited to the nominal power of the central
power unit. For exterior installations, the power
socket must have a suitable IP rating.
CRUSHING HAZARD: when handling and installing
the central power unit it is recommended to use
suitable equipment for lifting and securing it
to prevent the central power unit from falling
accidentally.
HAZARD OF DAMAGING THE CENTRAL POWER
UNIT: follow the provided instructions for use
to prevent consequences that could damage the
central power unit.
INHALATION OF HARMFUL ELEMENTS AND DUST:
protect respiratory organs by using protective
masks when emptying the dust containers and
when replacing the filter cartridge so the collected
dust is not inhaled.
DUST SENSITIVITY: this means that hand
protection must be used to prevent harming
operators who are sensitive to the collected dust.
Quality system
UNI EN ISO 9001
Environmental management
system
UNI EN ISO 14001
Product certication for the single-
phase power unit range for the
residential market sector, series:
PERFETTO INOX TXA
PERFETTO TPA
PERFETTO TP
CLASSIC TC
certifications
Aertecnica S.p.A is a company certified with:
iDentification
This user and maintenance manual is an inherent part of
the central power unit:
SERIES: PERFETTO INOX TXA
MOD: TX1A - TX2A - TX3A - TX4A
SERIES: PERFETTO TPA
MOD: TP1A - TP2A - TP3A - TP4A
SERIES: PERFETTO TP
MOD: TP1 - TP2 - TP3 - TP4
SERIES: CLASSIC TC
MOD: TC1 - TC2 - TC3 - TC4
Manufacturer
AERTECNICA S.p.A.
Via Cerchia di Sant’Egidio,760
47521 Cesena (FC) ITALY
Tel. +39 0547/637311
Fax +39 0547/631388
www.aertecnica.com
Technical service
The Technical Service Centre can be contacted for all
technical problems and in order to request spare parts.
For all communications concerning the central power
unit, the user should always provide the following data:
central power unit model
serial number
year of manufacturing
date of purchase and a detailed description of the
discovered problems.
When replacing the central power unit's spare parts it
is recommended to use original spare parts; Aertecnica
declines all liability concerning decreased performance
or damage to the central power unit due to the use of
non-original spare parts.
User and maintenance manual
4General information
General information

english
iDentification plate
For these models, the identification plate is located on
the body of the central power unit as shown in the
figure.
The necessary identification data:
model
serial number
year of manufacturing.
Description of the tubò
vacuuM systeM
The purchased central power unit is the main component
of TUBÒ, Aertecnica's advanced vacuum system.
The TUBÒ system consists of the central power unit,
vacuum sockets installed in the building's walls, the
hose that is inserted in the vacuum sockets based on
the room to be cleaned and a set of cleaning accessories
suitable for all residential needs.
A network of plastic pipes installed under the floor and
in the walls of the building form the dust intake line
that is connected to the central power unit.
The collected dust reaches the central power unit; the
large dust particles fall into the collection container
whereas a filter cartridge retains the suspended dust;
the micro dust (invisible to the eye and not filtered
by the cartridge) is discharged outside through the
air exhaust line, guaranteeing home hygiene and
preventing the dust from recirculating in homes.
The system must only be used by one operator.
The system must only be used with the hose and
cleaning accessories connected to Aertecnica sockets
installed in the building.
The system can reach all areas of the home, both
inside as well as outside depending on the position
of the vacuum sockets installed in the building. The
recommended hose is 7 m long, which makes it possible
to cover a circular area of approx. 30 m2 (a reduction
in the radius of the circumference is due to obstacles in
the room (furniture) that make it necessary for the tube
to follow a curved path).
The dust container must be emptied periodically (approx.
2-3 times a year; see paragraph CONTAINER EMPTYING).
The filter cartridge should be replaced with a new one
every 2-3 years (based on its use; see paragraph FILTER
CARTRIDGE REPLACEMENT).
The filter cartridge can be regenerated by washing it
periodically (based on its use; see paragraph FILTER
CARTRIDGE REGENERATION).
These timescales are approximate for normal vacuum
system use. In the case of intense use of the system
and a large amount of vacuumed dust, the timescale
will be shortened.
General information
General information
5

english
part Description
CLASSIC TC LINE
1 - Dual right/left air exhaust
2 - Motor air intake (mod. CLASSIC TC3, TC4)
3 - Sound-proofed motor chamber
4 - Electric motor
5 - Temperature sensor
6 - Power electronic board
7 - AVT panel
8 - Dual right/left dust inlet
9 - PRECISION filter cartridge
10 - QUICK FIX bracket
11 - Ergonomic handles
12 - Cone conveyor
13 - Dust container
14 - Dust inlet closing cap
15 - 12V socket line and power supply line casing
PERFETTO INOX TXA, TPA AND TP LINE
1 - Dual right/left air exhaust
2 - Motor air intake (excluding mod. PERFETTO TX1A, TP1A and TP1)
3 - Sound-proofed motor chamber
4 - Electric motor
5 - Temperature sensor
6 - Electronic card EVOLUTION 1.0
7 –AVI display and bult-in keyboard
8 - Dual right/left dust inlet
9 - Built-in vacuum socket
10 - PRECISION filter cartridge
11 - Self-Cleaning filter APF system
(mod. PERFETTO TXA and TPA)
12 - QUICK FIX bracket
13 - Side multifunction pockets
(excluding mod. PERFETTO TX1A, TP1A and TP1)
14 - Ergonomic handles
15 - Cone conveyor
16 - CLEAN BAG dust bag
17 - CLEAN BAG blocking system
18 - Dust container
19 - Dust inlet closing cap
20 - 12V socket line and power supply line casing
1
1
2
3 4 5
6
7
15
8
9
10
8
12
11
13
14
11
11
1
1
2
3 4 5
7
9
19
20
8
10
8
13
15
14
16
17
14
13
12
6
User and maintenance manual
6General information
General information

english
Line Perfetto INOX TXA Perfetto TPA
TP
Classic TC
Model TX1A TX2A TX3A TX4A TP1A
TP1
TP2A
TP2
TP3A
TP3
TP4A
TP4
TC1 TC2 TC3 TC4
Power supply Volt (Vac) 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240
Motor power Watts (W) 1.260 1.600 1.350 1.590 1.260 1.600 1.350 1.590 1.260 1.600 1.350 1.590
Frequency Hz50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Electric protection IP IP551IP551IP452IP452IP551IP551IP452IP452IP551IP551IP452IP452
Motor rpm rpm
(giri/min.) 43.507 46.480 29.892 31.672 43.507 46.480 29.892 31.672 43.507 46.480 29.892 31.672
Turbine stages no. 1 1 3 3 1 1 3 3 1 1 3 3
Socket power supply Volt (Vcc) 12 12 12 12 12 12 12 12 12 12 12 12
Vacuum power Air Watts 504 653 526 566 504 653 526 566 504 653 526 566
Max. air ow rate m3/h 207 195 174 168 207 195 174 168 207 195 174 168
Max. vacuum mbar 270 313 374 413 270 313 374 413 270 313 374 413
Noise dB 62,5 63 64 64,5 62,5 63 64 64,5 62,5 63 64 64,5
Filter cartridge
surface cm24.000 8.200 12.300 12.300 4.000 8.200 12.300 12.300 4.000 8.200 12.300 12.300
Filter cartridge
material POLYESTER POLYESTER POLYESTER
Dust container
capacity litres 13,5 13,5 22 22 13,5 13,5 22 22 13,5 13,5 22 22
Height cm 60 90 115 115 60 90 115 115 60 90 115 115
Diameter cm 30 30 34 34 30 30 34 34 30 30 34 34
Weight kg 10,8 13,8 17,3 17,3 10,8
9,8
13,8
12,8
17,3
16,3
17,3
16,3
9,5 12,2 15,3 15,3
Dynamic
Control Display
compatibility
(CMT800)
YES YES YES YES YES YES YES YES YES YES YES YES
Wireless system
compatibility
(CM187)
YES YES YES YES YES YES YES YES YES YES YES YES
SOFT START starting YES YES YES YES YES YES YES YES YES YES YES YES
Right and left dust
inlet YES YES YES YES YES YES YES YES YES YES YES YES
Right and left air
exhaust YES YES YES YES YES YES YES YES YES YES YES YES
AVI display YES YES YES YES YES YES YES YES NO NO NO NO
AVT panel NO NO NO NO NO NO NO NO YES YES YES YES
ModBus
communication
system
YES YES YES YES YES YES YES YES YES YES YES YES
QUICK FIX bracket YES YES YES YES YES YES YES YES YES YES YES YES
APF system YES YES
NO YES YES YES
NO
YES
NO
YES
NO
YES
NO NO NO NO NO
Built-in vacuum
socket YES YES YES YES YES YES YES YES NO NO NO NO
CLEAN BAG YES YES YES YES YES YES YES YES NO NO NO NO
Multifunction
Pockets NO YES YES YES NO YES YES YES NO NO NO NO
Silencer as standard
equipment NO YES YES YES NO YES YES YES NO YES YES YES
1
IP55 exhaust conveyor with exhaust tubing
IP43 direct exhaust from the central power unit, without exhaust piping
2
IP45 exhaust conveyor with exhaust tubing
IP43 direct exhaust from the central power unit, without
exhaust piping
technical features
General information
General information
7

english
foreseen use
The central power unit was designed to be connected
to tubing able to vacuum dust. The operator uses
the hose and cleaning accessories connected to the
Aertecnica sockets. The system must only be used by a
single operator to only vacuum dust or minuscule solid
particles, using only one vacuum socket at a time in
order to secure adequate efficiency.
The CLEAN BAG (in the PERFETTO TXA, TPA and TP series)
must be replaced with a new one each time that it is
filled.
The dust container (in the CLASSIC TC series) must be
emptied each time that it is filled.
The filter cartridge must be regenerated periodically
and must be replaced every 2-3 years or immediately
if it breaks. When replacing spare parts, use original
Aertecnica spare parts.
prohibiteD use
- Do not vacuum lighted cigarettes, hot embers or
burning material: these materials may cause a fire to
start that would damage the hoses and the central
power unit.
- Do not vacuum cloths, rags, fabrics or textile material:
these materials could obstruct the hoses or damage the
central power unit .
- Do not allow children to play with the vacuum sockets,
opening and closing them continuously or inserting
toys or solid items of unsuitable dimensions.
- Do not use the system with the central power unit
turned on without the filter cartridge inserted.
- Do not block the air exhaust line.
- Do not block the air sockets for electric motor cooling.
- Do not use the cleaning accessories to vacuum parts
of the body.
- Do not install the central power unit in an environment
classified as ATEX as per European Union standards.
unauthoriseD use
- Do not vacuum liquids, materials saturated with
liquids or very moist materials: these materials could
cause the electric system to short circuit, prevent the
proper passage of the dust or damage the sockets and
the central power unit.
turninG on/off
The standard hose comes in two types:
TYPE 1 : hose with an activator union: the central
power unit turns on when the union (B) is inserted in the
vacuum socket (A).
TYPE 2: hose with a switch: the central power unit is
turned on using the switch on the hose itself.
Insert the hose-socket union with the special plates (D)
in correspondence of the contacts (E) inside the socket.
To turn off the central power unit:
with the TYPE 1 hose, remove the hose from the vacuum
socket (A);
with the TYPE 2 hose, move the switch to the OFF position
Liquid can be vacuumed using a special accessory (art.
AP372; art. AP373).
- Do not vacuum dust using more than one vacuum
socket at the same time.
- Never leave the hose and cleaning accessories
connected to the system unattended whilst the central
power unit is on.
operator
The operator must not present limited physical, sensory
or mental capabilities; the operator must not be an
unskilled person or a person with no knowledge of
the product unless the aforementioned is under the
supervision of somebody responsible for their safety or
has received instructions with regards using the central
power unit.
The operator must be over the age of 14 years.
The operator must always be careful when using the
system in order to avoid tripping over the hose or
cleaning accessories connected to the system, and must
extend these same personal safety measures to the
persons which may be present in the area at the same
time.
Use personal protection garments before
carrying out operations such as emptying
the dust container or replacing/cleaning the
ltering cartridge.
E
A
B
E
A
D
C
TYPE 1 TYPE 2
User and maintenance manual
8General information
General information

english
OK
mbar
1,5 mt.
built-in vacuuM socket
The models in the PERFETTO TXA, TPA and TP line have a
built-in vacuum socket (1).
Turning on the central power unit
After inserting the union (3) in the socket (1), start the
central power unit by pressing the START button on the
control panel (4).
Turning off the central power unit
The central power unit turns off by pressing the STOP
button on the control panel (5) for one second or 15
seconds after closing the door (2).
The built-in vacuum socket can be used for cleaning the
central power unit's equipment room.
the wireless kit (cM187)
The Wireless hose is the solution for situations in which
the system does not have the electrical preparation or to
add a new socket to an already existing system without
installing the 12V socket line.
It can be used with all types of vacuum sockets.
The kit includes a wireless hose (1) and a receiver (2).
The 12V socket line cable that is supplied with the
central power unit must be connected directly to the
wireless input on the central power unit's electronic
card
Receiver transmission power
Inside a building, the transmission range between the
wireless hose and the receiver is 15 m, which makes it
possible to go up or down 2 floors.
Starting/stopping the central power unit
The central power starts when the START/STOP button is
pressed (3). The LED (4) turns green.
The central power unit stops when the START/STOP
button is pressed again or 15 seconds after the vacuum
socket door is closed.
NOTE
With socket models Air Active, Open and the NEW AIR
sockets with a microswitch (NA699) the central power
unit turns on when the socket door is opened.
2
1
4
3
1
3
2
4
5
General information
General information
9

english
opening the packaging
The central power unit is delivered inside cardboard
packaging to make it easier to transport.
It is recommended to not remove the packaging until
installation to prevent damaging it.
When opening the central power unit packaging, follow
the instructions indicated on the sides of the cardboard
box.
Check that the product is not damaged and that the
box contains the warranty voucher with the coupon to
be filled out completely and resent to Aertecnica (see
WARRANTY paragraph).
The packaging elements that accompany
the central power unit upon delivery are
inert solid waste that must be disposed of
according to current applicable regulations.
External central power unit
When installing the central power unit
externally ensure that a junction box with
an adequate degree of electrical protection
is used.
NOTENOTE
handling the packaging
To lift and transport the central power unit, use the
handles positioned on the sides of the packaging (A).
inStallation location
The central power unit must be installed in well-ventilated
service rooms (for example, closets, garages, cellars or attic
rooms) protected from significant climate changes.
The high level of electrical protection and resistance to
the elements allows for the extension of installation
of the central power unit to outdoor environments, on
balconies, loggias and verandahs.
The 220/240 power supply and the socket activation
line must be near to the central power unit in order to
activate the vacuum cleaning system.
The installation location must have adequate dimensions
(a minimum of 1,000 mm in front of the central power
unit) to allow for filter cartridge, dust bag or dust
container replacement operations.
The installation location must be sufficiently illuminated
(minimum of 300 lumen) to allow for maintenance
operations and operations on the central power unit
control panel.
The central power unit must not be placed in an
environment classified as ATEX.
10 User and maintenance manual Installation
Installation

english
centRal poWeR Unit inStallation
alloWanceS
The following table specifies the main reference allowances
for correct central power unit installation.
TX1A TX2A TX3A TX4A TP1/TP1A TP2/TP2A TP3/TP3A TP4/TP4A TC1 TC2 TC3 TC4
A138 418 418 138 328
328
350
257
300
286
230
34
900
273
115
103
560
1400
418 418 138 328 418 418
B350 350 350 350 350 350 350 350 350 350 350
C257 257 257 257 257 257 257 257 257 257 257
PERFETTO TXA PERFETTO TP - PERFETTO TPA CLASSIC TC
D300 340 340 300 300 340 340 300 300 340 340
E286 304 304 286 286 304 304 286 286 304 304
F230 340 340 230 230 340 340 230 230 340 340
G34 34 34 34 34 34 34 34 34 34 34
H600 1115 1115 600 900 1115 1115 600 900 1115 1115
I273 308 308 273 273 308 308 273 273 308 308
L115 137 137 115 115 137 137 115 115 137 137
M103 112 112 103 103 112 112 103 103 112 112
N560 600 600 560 560 600 600 560 560 600 600
P** 1500 1400 1400 1500 1400 1400 1400 1500 1400 1400 1400
P**
Q
recommended allowance
oor level
The indicates measurements are in mm.
N
H
G
F
B
C
E
240 V
12 V
I
A
P
Q
L
M
D
Installation
Installation
11

english
bRacket faStening
1 - Make the holes in the wall
2 - Fasten the bracket to the wall following the
described assembly order:
A - Screw 6x70
B - Flat washer 6x24
C - Rubber washer
D - End stop
E - Rubber antivibration pad
3 - Stand with the central power unit in front of the
bracket and use a downward movement to hook the
central power unit support to the bracket slide.
4 - With a simple left to right movement, slide the
central power unit support to the end stop.
6 - To unhook the central power unit from the support,
press the lock hook with the help of a screw driver (F).
Slide the central power unit to the left and lift it.
Unhooking the central power unit
5 - The lock hook must release with a CLICK; use a
screwdriver for leverage if necessary (see figure 6,
letter F).
ABCD
EB
F
12 User and maintenance manual Installation
Installation

english
connection
exhaUSt conveyoR line
All of the central power units have a dual air exhaust
outlet to permit the installation of the air exhaust
line on both sides of the central power unit, making
installation easier.
Select the most convenient air exhaust outlet to connect
the central power unit. Connect the exhaust conveyor
line hose with the provided clamp (f).
It is recommended to install an exhaust hose that is no
longer than 5 metres.
If the exhaust line is longer, use a hose with a diameter
of ø 63 or larger and install a silencer of a suitable
diameter.
Always position the silencer near the exhaust grille.
Air exhaust line components
1 - silencer ø100
2 - conical increase ø50F - ø82F
3 - exhaust grille ø82
4 - outlet hole ø82
Use an exhaust grille code TR310 or similar grille without
the presence of insect protection netting.
In the instance of a ø50 terminal, use an exhaust grille
code TR316.
Dust inlet line connection
All of the central power units have a dual dust inlet to
permit the connection of the socket line hose on both
sides of the central power unit, making installation
easier.
Select the most convenient central power unit dust
inlet to connect the dust inlet line. Assemble the rubber
sleeve (a) on the dust inlet using the two provided
clamps (b) and connect it to the inlet hose (c).
Close the dust inlet not in use
The dust inlet not in use (d) must be closed by pressing
on the relevant closing cap (e) provided.
connection
dUSt inlet line
OK
mbar
OK
mbar
c
d
b
a
d
bc
a
e
d
NOTE
ø 50
ø100
300 mm
ø 50
ø 82
ø 82
1
3
2
4
OK
mbar
max 5m.
fg
Installation
Installation
13

english
OK
mbar
diRect exteRnal aiR exhaUSt line
If the central power unit is installed outside (on a
terrace, balcony or loggia) the air exhaust conveyor is
not needed as it uses the air exhaust openings (J) on the
central power unit itself.
It is necessary to assemble, on both openings (J) the
relevant discharge grilles, provided with the central
power unit, according to the description provided in the
following paragraph.
aiR diSchaRge gRille
Fit the 2 grilles in both air exhaust openings following
the instructions indicated below.
The inner side is the one with the grille; the grille blades
must be rotated downward.
The external side is the one with a helicoidal section
drawing.
electRic motoR aiR intakeS
The PERFETTO TX3A and TX4A, TP3A and TP4A, TP3
and TP4, TC3 and TC4 power units have air intakes (h)
that must not be blocked to guarantee electric motor
cooling.
Remove the internal protective sponge (k) and wash it
once a year to ensure air passage.
This solution is indicated only for central power units
installed externally.
NOTE
Close the air discharge union not in use
The air discharge union not in use (g) must be closed
using cap (h) and fixed using the clamp (f) provided.
h
f
g
J J
NOTE
k
h
hh
14 User and maintenance manual Installation
Installation

english
4
5
2
1
7
6
3
3
7
2
1 2 3 4 5 61 2
gray
green
black
green
red
blue
white
brown
yellow
+12 Vcc
-GND
TXA
OK
mbar
TXB
electRical connection of the
tUbÒ SyStem
The central power unit electric power
supply system must be installed by qualied
personnel in compliance with current
applicable regulations.
The manufacturer declines all liability for
poor operation or damage to people and/
or property due to connection to a non-
compliant electric system
Connection of the central power unit to the power
supply line
The power supply cable with Schuko plug (A) for the
central power unit is supplied as standard equipment
with the central power unit .
Connection of the central power unit to the socket line
A socket cable connection is supplied with the socket
activation line and remote data transmission (B) as
standard equipment.
DANGER OF ELECTROCUTION
Make sure that the electric line is
dimensioned to support the central power
unit power and check that the mains network
corresponds to the voltage specied on the
identication plate.
A
B
ELECTRICAL CONNECTION DIAGRAM
To make the socket line connection, wire the central
power unit connection cable as shown in the figure
ELECTRICAL DANGER
If the power supply cable is damaged, it
must be replaced by the manufacturer or its
Technical Service Centre or in any case by a
specialised technician in order to prevent all
electrical hazards.
DISCONNECT THE POWER SUPPLY
TO THE CENTRAL POWER UNIT
To fully disconnect the central power unit from the
electric line, remove the Schuko plug (A) from the
power point.
General components
1 - central power unit power supply cable
2 - 12v socket cable line
+ Dynamic Control Display (CMT800)
3 - electric junction box
4 - pre-wired sheathing 2x1 ø16
for socket line
5 - pre-wired sheathing 4x1 ø16
6 - inlet frames
7 - Dynamic Control Display (CMT800)
Vacuum socket
contact
Installation
Installation
15

english
contRol panel
With avi diSplay and keyboaRd
(for PERFETTO TXA, TPA and TP central power units)
AVI DISPLAY
The alpha-numeric display is controlled by the
EVOLUTION 1.0 electronic card and is used to control
the following parameters:
CLEAN BAG FILLING
This detects the filling level of the dust container and
displays 4 different levels.
FILTER CARTRIDGE SATURATION
This detects the saturation level of the filter cartridge
and displays 5 different levels.
OPERATING VACUUM RANGE
This displays the vacuum level at which the central
power unit is operating: LO (low) - OK (correct) - HI
(high)
OPERATING VACUUM
This displays the operating vacuum level of the central
power unit
MOTOR POWER PERCENTAGE
This displays the motor power percentage that is
adjusted on the hose with the speed variator.
TOTAL MOTOR HOURS
This displays the total hours of use of the central power
unit.
MOTOR TEMPERATURE
Displays the motor temperature.
STARTING ANOMALY/LOCK
Displays an anomaly/lock due to an excessive number of
starts within a 1 minute period.
MOTOR TEMPERATURE ANOMALY/LOCK
Displays an anomaly/lock due to the engine temperature
exceeding 80°C.
MAXIMUM USE TIME ANOMALY/LOCK
Displays an anomaly/lock due to continuous use of the
central power unit for 30 minutes.
KEYBOARD
The keyboard has 4 buttons that are used to perform the
following functions:
START BUTTON / r
The START button is used to start the central power unit
after inserting the hose in the built-in vacuum socket.
The rarrow is used to navigate the upper menu in the
programme.
STOP BUTTON / s
The STOP button is used to turn off the central power
unit. The unit also turns off 15 seconds after the built-in
vacuum socket door is closed. The sarrow is used to
navigate the lower menu in the programme.
RESET/ESC BUTTON
Pressing the button, the central power unit is reset after
a lock or anomaly (see ANOMALY OR LOCK paragraph).
MENU/OK BUTTON
By pressing the button, it displays the central power
unit's maintenance cycles.
The central power unit has a control panel that includes
an AVI display (immediate display) and a built-in
keyboard to navigate and control the various central
power unit operating parameters.
16 User and maintenance manual Installation
Installation

english
CONTROL PANEL OPERATION
ALPHA - NUMERIC DISPLAY
With the central power unit ON, it displays the following
operating parameters:
OPERATING VACUUM
In standard operating conditions, it displays
the operating vacuum level of the central
power unit
TOTAL MOTOR HOURS
pressing the MENU key twice, it displays the
total hours of central power unit use
MOTOR TEMPERATURE
pressing the MENU key three times, it displays
the temperature of the motor chamber
BAG FILLING
pressing the MENU key twice, it displays the
amount of time that passed, in hours, since the
last CLEAN BAG maintenance was performed
STAND BY
If 30 seconds pass without pressing any key,
3 continuously flashing LED appear in the
display.
By pressing any key, the central power unit
exits STAND BY status and displays the total
hours of central power unit use.
MOTOR POWER PERCENTAGE
by pressing the MENU key once, it displays the
motor power percentage that is adjusted on
the hose with the speed variator.
Once the vacuuming phase is completed with the central
power unit in STAND BY, this displays the following
operating parameters:
TOTAL MOTOR HOURS
this displays the total hours of use of the
central power unit
FILTER SATURATION
by pressing the MENU key once, it displays
the saturation degree of the filter cartridge,
expressed in mbar according to this reference
scale:
0 mbar = filter clean
10 mbar = filter saturated 50%
20 mbar = filter saturated 100%
OK
mbar
OK
OK
h
Installation
Installation
17

english
vacuum high
(171 - 240 mbar)
vacuum correct
(90 - 170) mbar)
vacuum low
(0 - 89) mbar)
CONTAINER/CLEAN BAG
FILLING LEVEL
This calculates the presumed filling level of the dust
container or CLEAN BAG, using 4 progressive stages.
lling level 25-49 %
lling level 50-74 %
lling level 75-99 %
lling level 100 % - the bag is
completely full and must be
replaced
(see ANOMALY AND LOCK TABLE)
FILTER CARTRIDGE
SATURATION LEVEL
The filter cartridge saturation level is displayed with 5
progressive stages.
saturation 20 - 39 %
saturation 40 - 59 %
saturation 60 - 79 %
saturation 80 - 99 %
saturation 100 % - the central
control unit stops due to lter
saturation lock.
(see ANOMALY AND LOCK TABLE)
STARTING ANOMALY/LOCK
Displays an anomaly/lock due to an excessive number of
starts/stops within a 1 minute period.
OPERATING VACUUM RANGE
Indicates the vacuuming power at which the system
is operating. 3 different vacuum levels are shown on
the display
If the system operates at a vacuum level
greater than 240 mbar, the wording will
ash and the central power unit will be
locked after 15 seconds due to excessive
operating vacuum.
(see ANOMALY AND LOCK TABLE)
MOTOR TEMPERATURE ANOMALY/LOCK
Displays an anomaly/lock due to the motor chamber
temperature exceeding 80°C.
the temperature warning light appears,
which ashes together with the xed
maintenance warning light that
indicates a central power unit lock due
to motor chamber overheating.
(see ANOMALY AND LOCK TABLE)
After 5 consecutive starts during a one
minute period, the warning light signals
thatthecentralpowerunitwillbelocked
if started again within one minute. (see
ANOMALY AND LOCK TABLE)
After 6 consecutive starts during a
one minute period, the central power
unit is locked.
(see ANOMALY AND LOCK TABLE)
After 29 minutes of continuous sys-
tem use, a ashing clock appears that
indicates the maximum use time.
(see ANOMALY AND LOCK TABLE)
The central power unit is locked due to
continuous system use for 30 minutes.
(see ANOMALY AND LOCK TABLE)
MAXIMUM USE TIME ANOMALY/LOCK
Displays an anomaly/lock due to continuous use of the
system for 30 minutes.
+
+
+
+
18 User and maintenance manual Installation
Installation

english
AVT conTrol pAnel
(on CLASSIC TC central power units)
AVT PANEL
The central power unit is equipped with an AVT panel
(timed display) that makes it possible to display the
central power unit's main maintenance operations.
DUST CONTAINER FILLING LED
Indicates the presumed maximum filling of
the dust container.
When the LED turns on, the dust container is full and
must be emptied.
Perform the maintenance and turn off the signal by
pressing the PRESS RESET button.
FILTER CARTRIDGE SATURATION LED
Indicates the presumed maximum saturation
of the filter cartridge.
When the warning light turns on, the filter cartridge is
saturated and must be regenerated or replaced.
Perform the maintenance and turn off the signal by
pressing the PRESS RESET button.
MOTOR TEMPERATURE LED
This indicates a central power unit lock due to
a motor chamber temperature that exceeds 80°C.
To reset central power unit use, the temperature must
go below 55°C.
After the temperature has gone below 55°C, press the
PRESS RESET button to remove the signal
LED ON
This indicates normal central power unit operation.
LED ON BLINKING
Indicates that the operating vacuum exceeds the value
of 240 mbar. The central power unit will be locked after
15 seconds.
CONTROL PANEL OPERATION
LED STAND BY
This indicates that the central power unit is
powered but not being used.
PRESS RESET BUTTON
This is used to reset central power unit anomalies
HIGH OPERATING VACUUM LOCK
The central power unit is locked because the operating
vacuum exceeded the 240 mbar limit for more than 15
seconds;
The ON and PRESS RESET lights blink ( see LOCK TABLE
of the TC central power units)
Switch off the signal by pressing the PRESS RESET
button.
Installation
Installation
19

english
central power unit inspection
The general centralised vacuum system inspection must be done after the final assembly of all vacuum sockets and the
selected central power unit
PERFETTO TXA, TPA AND TP CENTRAL POWER UNITS
Check 1
Activate the central power unit with all sockets closed by pressing the START button on the control panel. The display
will show the maximum vacuum level reached by the central power unit, which will stop automatically after 15 seconds.
Note the value that was reached (value 1).
Disconnect the tubing from the central power unit and place a cap on the central power unit inlet.
Reactivate the central power unit and note the value that was reached (value 2) indicated on the display.
Check that the difference between values 2 and 1 does not exceed 15 mbar.
If the value is higher, this means that there are leaks that must be found and repaired.
Check 2
Compare value 2 with the vacuum value indicated in the technical features table for the central power unit model that
was purchased.
Check that the difference between the two values does not exceed 10% of the table value.
If the value is higher, contact the Aertecnica Service Centre.
Note
The values indicated in the table refer to a power supply voltage of 240 V at 50 Hz. If the mains voltage is less,
use the following formula:
every 10 volt = 10 mbar (example with the TP1 central power unit: 270 mbar at 240 V = 250 mbar at 220 V).
CLASSIC TC CENTRAL POWER UNITS
Check 1
Activate the central power unit with all sockets closed, jumpering the 12V socket line.
Inserting the vacuum gauge in the dust inlet that is not used or in any vacuum socket, check the vacuum value obtained
by the central power unit, which will stop automatically after 15 seconds. Note the value that was reached (value 1).
Disconnect the tubing from the central power unit and insert a vacuum gauge
(AT010)
in its place. Activate the central
power unit jumpering the 12V socket cable line; check the vacuum value obtained by the central power unit, which will
stop automatically after 15 seconds. Note the value that was reached (value 2).
Check that the difference between values 2 and 1 does not exceed 15 mbar.
If the value is higher, this means that there are leaks that must be found and repaired.
Check 2
Compare value 2 with the vacuum value indicated in the technical features table for the central power unit model that
was purchased.
Check that the difference between the two values does not exceed 10% of the table value.
If the value is higher, contact the Aertecnica Service Centre.
Note
the values indicated in the table refer to a power supply voltage of 240 V at 50 Hz. If the mains voltage is less,
use the following formula:
every 10 volt = 10 mbar (example with the TP1 central power unit: 270 mbar at 240 V = 250 mbar at 220 V).
VACUUM TEST - FOR ALL CENTRAL POWER UNITS
Insert the hose in the furthest socket and activate the central power unit.
For PERFETTO TXA,TPA and TP central power units: the vacuum value will appear on the display; if the value is
correct (RANGE between 90 and 170 mbar) OK will be displayed. In this case, the test is positive.
Otherwise, contact the Aertecnica Service Centre.
For CLASSIC TC central power units: insert the vacuum gauge (AT010) in the socket adjacent to the one occupied by
the hose; if the vacuum value is correct (RANGE between 100 and 150 mbar) the hand will point to the green zone. In
this case, the test is positive. Otherwise, contact the Aertecnica Service Centre.
User and maintenance manual
20 Maintenance
Maintenance
This manual suits for next models
3
Table of contents
Other AERTECNICA Vacuum Cleaner manuals

AERTECNICA
AERTECNICA TUBO STUDIO TS1 User manual

AERTECNICA
AERTECNICA AIRO TWIST User manual

AERTECNICA
AERTECNICA TUBO ROBO ITR804 User manual

AERTECNICA
AERTECNICA TUBO ROBO TR900L User manual

AERTECNICA
AERTECNICA ROBO TR800 User manual

AERTECNICA
AERTECNICA AP353PR Operator's manual

AERTECNICA
AERTECNICA TUBO CM188T User manual

AERTECNICA
AERTECNICA TUBO FAST User manual