Aiphone IS-DVF-2RA-FR User manual

IS-DVF-2RA-FR
Stainless Steel Flush Mount Video Door Station with
Standard & Emergency Call Buttons
-INSTRUCTIONS-
STEADY GREEN INDICATES CALL ANSWERED
CALL
EMERGENCY
IS-DVF-2RA-FR
Pg.1
The IS-DVF-2RA-FR is a stainless steel ush mount video door station with standard and emergency
call buttons. The unit is equipped with signage in French for both the standard and emergency
buttons. A call status indicator is included to meet rescue assistance requirements.
The IS-DVF-2RA-FR must connect to the IS-CCU or IS-SCU control units.
1
2
3
4
5
6
7
8
9
IS-DVF-2RA-FR NAMES & FUNCTIONS:
1. Camera 6. Call status indicator
2. Microphone 7. French Signage
3. LED Light 8. Call button
4. Speaker 9. Emergency button
5. Name Placard
FEATURES:
• Audio communication with visual indentication
of calling area
• Two call buttons: Standard and Emergency
• LED call status indicator
• CCTV input
• Red mushroom button for emergency call
• Two programmable relay outputs for activation
of external systems/devices
• Name placard
• Stainless steel faceplate with tamper resistant
screws
PACKAGE CONTENTS:
IS-DVF-2RA-FR
Vandal-resistant Door Station
Semi-ush backbox &
tamper-resistant screws
Security Driver
Blank name
placard
INSTALLATION:
• For ush mounting, cut a hole in the wall and
use supplied back box.
Box dimensions are:
11-1/16” H x 5-13/16” W x 1-3/4” D
• For surface mounting, use the SBX-ISDVFRA
surface mount box. This box can mount to a
standard 1-gang box or to any at surface.
Pg. 2
IS-DVF-2RA-FR Instr.
0716
WIRING DIAGRAM:
IS-DVF-2RA-FR
IS-CCU
IS-MV
IS-PU-UL
N/O Dry Contact
0.5 Amp
CAT-5e
CAT-5e
NO
COM
NC
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
• For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
• Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
SPECIFICATIONS:
Camera unit: CMOS camera
Scanning line: 525 lines
Min. illumination: 5 Lux at 1’6”
Terminations: RJ45 jack for audio/video
Screw terminals for door release and relay outputs
Relay rating: 24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board
Operating Temp: 14° ~ 140°F / -10° ~ 60°C
Wiring Distance: 980’ with Cat5e/6 cable
Dimensions: 11-3/4” H x 7” W
w/SBX-ISDVFRA: 11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)
OFF ON
NO
NO
C
NC
C
NC
1234
RELAY BOARD WIRING AND SETTINGS:
Relay 1 Output
N/O, COM, N/C
Relay 2 Output
N/O, COM, N/C
*Relay 2 External Reset
Connect to N/O dry switch
Conguration Switch
See Settings to right
OFF ON
NO
NO
C
NC
C
NC
1234
Board on back of unit
See wiring below
ON
1234
Default Conguration when shipped
Optional Conguration
Normal Call
Emergency Call
Talking
Door Release
Trigger Source RY1 Triggered? RY1 Remains ON
During Talking? RY2 Triggered? RY2 Remains ON
During Talking?
RY2 Requires
Reset?
YES
NO N/A
YES
YES YES
YES YES NO
NO
NO
NO
N/A
N/A
N/A
N/A
N/A
N/A
YES
YES
ON
1234
Contact Technical Support if additional switch congurations
are required.
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on emergency call and remains on during communication.
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on an emergency call and remains on during communication. Relay 2 requires reset.
Normal Call
Emergency Call
Talking
Door Release
Trigger Source RY1 Triggered? RY1 Remains ON
During Talking? RY2 Triggered? RY2 Remains ON
During Talking?
RY2 Requires
Reset?
YES
NO N/A
YES
NO N/A
N/A
N/A
YES
YES
YES
YES
YES YES
N/A
N/A
N/A
NO
NO
YES*
A
iphone Corporation
(800) 692-0200
[email protected]
www.aiphone.com

Other Aiphone Intercom System manuals

Aiphone JF-2MED User manual

Aiphone

Aiphone JF-2MED User manual

Aiphone MCW-P3 User manual

Aiphone

Aiphone MCW-P3 User manual

Aiphone PC-359B User manual

Aiphone

Aiphone PC-359B User manual

Aiphone AN-8000 SERIES User manual

Aiphone

Aiphone AN-8000 SERIES User manual

Aiphone GT-DMB-N User manual

Aiphone

Aiphone GT-DMB-N User manual

Aiphone LE-SSR User manual

Aiphone

Aiphone LE-SSR User manual

Aiphone PP-MK User manual

Aiphone

Aiphone PP-MK User manual

Aiphone GT-1C7 User manual

Aiphone

Aiphone GT-1C7 User manual

Aiphone KB-3MRD User manual

Aiphone

Aiphone KB-3MRD User manual

Aiphone GF-1MDK User manual

Aiphone

Aiphone GF-1MDK User manual

Aiphone KB-3SD User manual

Aiphone

Aiphone KB-3SD User manual

Aiphone AH-108 User manual

Aiphone

Aiphone AH-108 User manual

Aiphone LA-20AS User manual

Aiphone

Aiphone LA-20AS User manual

Aiphone NDRM-20 User manual

Aiphone

Aiphone NDRM-20 User manual

Aiphone PB-2 User manual

Aiphone

Aiphone PB-2 User manual

Aiphone IX-SS-2G User manual

Aiphone

Aiphone IX-SS-2G User manual

Aiphone JM-4MED User manual

Aiphone

Aiphone JM-4MED User manual

Aiphone MY-2CD User manual

Aiphone

Aiphone MY-2CD User manual

Aiphone JF-1MD User manual

Aiphone

Aiphone JF-1MD User manual

Aiphone IS-SS-CI Manual

Aiphone

Aiphone IS-SS-CI Manual

Aiphone NDA-20 User manual

Aiphone

Aiphone NDA-20 User manual

Aiphone IS SERIES Manual

Aiphone

Aiphone IS SERIES Manual

Aiphone INTERCOM AN-8000 User manual

Aiphone

Aiphone INTERCOM AN-8000 User manual

Aiphone NEM-10 User manual

Aiphone

Aiphone NEM-10 User manual

Popular Intercom System manuals by other brands

Panasonic VL-SWD501EX operating instructions

Panasonic

Panasonic VL-SWD501EX operating instructions

Fermax LOFT BUS2 Installer manual

Fermax

Fermax LOFT BUS2 Installer manual

Bosch Security Plena LBB 1925/10 Installation and operating manual

Bosch Security

Bosch Security Plena LBB 1925/10 Installation and operating manual

HOLOVISION 400-A-VIO installation instructions

HOLOVISION

HOLOVISION 400-A-VIO installation instructions

Netatmo NDB01 user guide

Netatmo

Netatmo NDB01 user guide

PS Engineering PM501 Operator's & installation manual

PS Engineering

PS Engineering PM501 Operator's & installation manual

Commax CDV-35U user manual

Commax

Commax CDV-35U user manual

Vimar ELVOX PIXEL UP: 40415.S Installer manual

Vimar

Vimar ELVOX PIXEL UP: 40415.S Installer manual

Clarson OUBLIC IV Service and installation manual

Clarson

Clarson OUBLIC IV Service and installation manual

Carus ARGOS manual

Carus

Carus ARGOS manual

Fermax House Keeper manual

Fermax

Fermax House Keeper manual

Emos H1009 Series manual

Emos

Emos H1009 Series manual

Videx ESVK/6388 Series Installation handbook

Videx

Videx ESVK/6388 Series Installation handbook

Spon NAS-8523DV instruction manual

Spon

Spon NAS-8523DV instruction manual

urmet domus Alpha 1168 Installation booklet

urmet domus

urmet domus Alpha 1168 Installation booklet

Amroad VP115 user guide

Amroad

Amroad VP115 user guide

Fermax DUOX plus 970049b Installer manual

Fermax

Fermax DUOX plus 970049b Installer manual

Intelligent Home IH-6912 Slave user manual

Intelligent Home

Intelligent Home IH-6912 Slave user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.