manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Airflow
  6. •
  7. Fan
  8. •
  9. Airflow AV125T User manual

Airflow AV125T User manual

AV100T Fan With Kit 9041407
AV125T Fan With Kit 9041406
AV100T Fan With Kit & LED 9041408
Aventa Fan Dimensions
Page 2 of 16 Page 3 of 16 Page 4 of 16
Range overview
Aventa In-line Mixed Flow fans are available in 3
model sizes with or without timer function and have
2 speeds.
Aventa In-line Mixed Flow fans can be used as a
simple extract or supply fan where high pressure
and flow rates are required. They can be mounted
vertically with a condensation trap fitted or
horizontally. The range has been designed to
accept standard ducting sizes. The main body of
the fan (1) is detachable from the inlet and outlet
spigots and mounting assembly via the 2 clamps
Page 5 of 16 Page 7 of 16
Mechanical installation
Determine the orientation of the fan airflow direction
by the use of the flow direction arrow on the fan body
(1). (See diagram on page 3).
Remove the fan body by releasing the 2 clamps (6).
Using the mounting base as a guide mark and drill 4
holes. Use the wall plugs and screws provided and
secure the mounting base to the mounting surface.
Insert the fan body (1) and secure with the retaining
clamps (6). (See diagram on page 3).
Connect the appropriately sized ducting to the spigot
ducts. Airflow Developments Ltd recommends that
rigid ducting is used instead of flexible ducting, this
will help to ensure maximum performance.
Type Air flow,
m3/h
Current,
Amps
Power,
Watts
Noise
level,
db(A) @
3m
AV 100/T 145/187 0.11/0.21 21/33 27/36
AV 125/T 220/280 0.18/0.27 23/37 28/37
Fan Specicaon
Electrical installation
The Aventa In-line Mixed Flow range is IPX4 rated
and is suitable for mounting in Zone 2 in bathrooms,
toilets, kitchens, utility rooms when installed with a
30mA RCD. The fan requires a 230V 50Hz single
phase supply. Class II equipment. BS EN 60417. An
external 3A fuse is required for each fan unit. Cable
sizes (max): Fixed flat wiring 2 core 1mm2, 3 core
1/1.5mm2. All electrical installation to be carried out
by an approved electrician in accordance with Part
“P” U.K. Building Regulations and to the latest IEEE
standards, or the appropriate regulations in the
country of installation.
Important
The Aventa In-line Mixed Flow fan range is IPX4
rated and complies with the requirements of the EU
norms and directives. Do not place the fan unit near
direct heat sources, e.g. radiant heaters, or where
temperatures can exceed 40°C (104°F).
Precautions must be taken to avoid back flow of
gases in rooms with open flue fuel burning
appliances.
Page 8 of 16
Aventa In-line Fan With Kit
230V Fan With Kit Installation and Operating Guide
Terminal Blocks Guide
AV100T , AV 125T Fan With Kit Min Speed
Max Speed
Page 6 of 16
Electrical installation
N Neutral
L Permanent Live
LT Switch Live High Speed
L1 Switch Live Low Speed
AV100T Fan With Kit & LED
Electrical installation
N
LN
L
N
LN
L
Max Speed
Min Speed
Fan Timer Adjustment
The fan with timer function switches on when the
voltage is supplied to the LT or L1 terminal via an
external switch.
After the voltage to the LT or L1 terminal is
disconnected the fan continues to run for the set
Run on timer period, between 1 and 20 minutes. The
Run on timer is factory set to 15 mins, it is adjusted
by turning the potentiometer (T) clockwise to
increase and anti-clockwise to decrease.
T
Increase
Decrease
2 Pole
isolator
3 Amp
Switched Fuse
3 Amp
Switched Fuse
2 Pole
isolator
2 Pole
isolator
2 Pole
isolator
3 Amp
Switched Fuse
3 Amp
Switched Fuse
L N
L N
L N
12V DC
L N
LED Driver
LED Driver
12V DC
Red Cable
Black Cable
Red Cable
Black Cable
Page 10 of 16 Page 11 of 16
Page 14 of 16 Page 15 of 16 Page 16 of 16
Page 9 of 16
Page 13 of 16
Warranty
Applicable to units installed and used in the United
Kingdom. Airflow Developments Ltd guarantees the
Aventa in-line for 3 YEARS from date of purchase
against faulty material or workmanship. Warranty only
covers the fan, not the reinstallation of this if required.
In the event of any defective parts being found, Airflow
Developments Ltd reserve the right to repair or at our
discretion replace without charge provided that the
unit:
1. Has been installed and used in accordance with the
fitting and wiring instructions supplied with each unit.
2. Has not been connected to an unsuitable electrical
supply.
3. Has not been subjected to misuse, neglect or
damage.
4. Has not been modified or repaired by any person
not authorised by Airflow Developments Ltd
5. Has been installed in accordance with latest
Building Regulations and IEEE wiring regulations by a
recognised competent installer.
Airflow Developments Ltd shall not be liable for any
loss, injury or other consequential damage, in the
event of a failure of the equipment or arising from, or
in connection with, the equipment excepting only that
nothing in this condition shall be construed as to
exclude or restrict liability for negligence.
This warranty does not in any way affect any
statutory or other consumer rights.
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT
FROM THE POWER SUPPLY BEFORE REMOVING
THE COVER.
When installed according to these instructions the
Aventa in-line range is completely safe. The materials
used do not constitute a hazard.
Cleaning
The external housing of the fan can be wiped with a
damp cloth. Do not use household cleaners containing
abrasives.
Note: Always isolate the fan when cleaning. Never
clean any parts of the fan assembly by immersing in
water or using a dishwasher.
Warning
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
Page 12 of 16
Recommended Best Practice
The Building Regulations 2010, Statutory Instrument
Part 9, paragraph 42, imposes a requirement that
testing and reporting of mechanical ventilation
performance is conducted in accordance with an
approved procedure.
Compliance with this requirement by an assessed and
registered ‘Competent Person’ should follow a ‘Best
Practice’ process and adopt air flow measurement,
Method A – The Unconditional Method – using a
suitable UKAS certified measuring instrument.
Generically referred to as a ‘Zero Pressure Air Flow
Meter’ or ‘Powered Flow Meter’.
Further information on this method is detailed in
NHBC Building Regulations Guidance Note G272a
10/13 and BSRIA ‘A Guide to Measuring air flow rates’
document BG46/2015
Installation with flexible ducting
Where flexible ducting is used the diameter must be
maintained with the minimum radius of a bend equal to
the diameter of the ducting. It is good ventilation
practice that the ducting is extended to 90% of its
possible length in order to maintain the best possible
airflow. Ensure that flexible duct connections are not
over tightened to the fan outlet spigot. To maximise
airflow rigid ducting should be used where possible.
The fan and ducting should be installed in accordance
with the requirements of the Domestic Ventilation
Compliance Guide, part of the Building Regulations.
UK Head-Office
AIRFLOW DEVELOPMENTS Limited
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Fax : +44 (0) 1494 461073
Email: info@airflow.com
Web: airflow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH
organizační složka Praha
Hostýnská 520
108 00 Praha 10
Czech Republic
Tel: +42 (0) 2 7477 2230
Fax: +42 (0) 2 7477 2370
Email: info@airow.cz
Web: airow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH
Wolbersacker 16
53359 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Fax: +49 (0) 222 69205 11
Email: info@airow.de
Web: airow.de
AIRFLOW DEVELOPMENTS LTD reserve the right in the interest of
connuous development to alter any or all specicaons without
80001054 Issue 1 03/21

This manual suits for next models

4

Other Airflow Fan manuals

Airflow 7106A User manual

Airflow

Airflow 7106A User manual

Airflow Duplexvent Rotary DV1500 User manual

Airflow

Airflow Duplexvent Rotary DV1500 User manual

Airflow QuietAir QT 100T User manual

Airflow

Airflow QuietAir QT 100T User manual

Airflow QuietAir QT 120T User manual

Airflow

Airflow QuietAir QT 120T User manual

Airflow QuietAir QT 100MST User manual

Airflow

Airflow QuietAir QT 100MST User manual

Airflow DV 90 SE R Specification sheet

Airflow

Airflow DV 90 SE R Specification sheet

Airflow ACES48ALR User manual

Airflow

Airflow ACES48ALR User manual

Airflow AV100T User manual

Airflow

Airflow AV100T User manual

Airflow Breeze 3.1 User manual

Airflow

Airflow Breeze 3.1 User manual

Airflow MaxAir 7105A User manual

Airflow

Airflow MaxAir 7105A User manual

Airflow iCON Series User manual

Airflow

Airflow iCON Series User manual

Airflow MV150 PECO User manual

Airflow

Airflow MV150 PECO User manual

Airflow Aventa AV100B Installation guide

Airflow

Airflow Aventa AV100B Installation guide

Airflow Uno hab Operating manual

Airflow

Airflow Uno hab Operating manual

Airflow iCON PCS User manual

Airflow

Airflow iCON PCS User manual

Airflow Uno hab Manual

Airflow

Airflow Uno hab Manual

Airflow 72687117 Installation guide

Airflow

Airflow 72687117 Installation guide

Airflow Uno hab User manual

Airflow

Airflow Uno hab User manual

Airflow WHV-8 User manual

Airflow

Airflow WHV-8 User manual

Airflow AFLR48 User manual

Airflow

Airflow AFLR48 User manual

Airflow Ceiling fans User manual

Airflow

Airflow Ceiling fans User manual

Airflow Adroit DV50 User manual

Airflow

Airflow Adroit DV50 User manual

Airflow LA VERNE User manual

Airflow

Airflow LA VERNE User manual

Airflow Duplexvent DV65 Entro-V User manual

Airflow

Airflow Duplexvent DV65 Entro-V User manual

Popular Fan manuals by other brands

Sealey SFF6USB instructions

Sealey

Sealey SFF6USB instructions

Accurex XUEF 100 Series Installation, operation and maintenance manual

Accurex

Accurex XUEF 100 Series Installation, operation and maintenance manual

All Seasons Hire Cyclone 30 operating instructions

All Seasons Hire

All Seasons Hire Cyclone 30 operating instructions

Casablanca Capistrano Owner's guide and installation manual

Casablanca

Casablanca Capistrano Owner's guide and installation manual

EDM 33952 instruction manual

EDM

EDM 33952 instruction manual

Panasonic FV-11VH1 Service manual

Panasonic

Panasonic FV-11VH1 Service manual

Orbegozo CF 101132 instruction manual

Orbegozo

Orbegozo CF 101132 instruction manual

QuietCool GA ES-1500 owner's guide

QuietCool

QuietCool GA ES-1500 owner's guide

Trisa electronics 9346.43 Instructions for use

Trisa electronics

Trisa electronics 9346.43 Instructions for use

NOMA Quatra 052-9329-2 instruction manual

NOMA

NOMA Quatra 052-9329-2 instruction manual

Clas Ohlson TF-803A quick start guide

Clas Ohlson

Clas Ohlson TF-803A quick start guide

Black & Decker BXEFF60E Original instructions

Black & Decker

Black & Decker BXEFF60E Original instructions

Applica C163CM Use and care book

Applica

Applica C163CM Use and care book

Cameo INSTANT AIR 2000 PRO user manual

Cameo

Cameo INSTANT AIR 2000 PRO user manual

Dantherm VentR Installation and service manual

Dantherm

Dantherm VentR Installation and service manual

ECG FS 45 R instruction manual

ECG

ECG FS 45 R instruction manual

Aereco VBP+ R Installation and Maintenance

Aereco

Aereco VBP+ R Installation and Maintenance

Samsung VRF DVM S Water Technical data book

Samsung

Samsung VRF DVM S Water Technical data book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.