Save these instructions
WARNING
Important safety instructions
Read all instructions before using this air cleaner.
When using an electrical appliance, basic precautions should always be followed, including the following:
• Make sure the local voltage used for the cleaner meets the rated voltage specified on the data plate at the
bottom of the machine. Make sure the cleaner is plugged into a live 110-120V AC outlet if the rated voltage
specified on the dataplate is 110-120V, or a 220-240V AC outlet if the rated voltage specified on the
dataplate is 220-240V.
•Always turn off and unplug the air cleaner when not in use.
• Disconnect the power supply from your air cleaner by unplugging the power cable before replacing filters,
cleaning, movement, or maintenance.
• Do not use attachments or filters not recommended by Airgle®.
• Do not use the air cleaner outdoors.
• Do not attempt to remove any part of the unit except the filters.
• Do not attempt to repair the air cleaner.
• Do not attempt to plug in the machine when your hands are wet.
• When unplugging the power cord, please be sure to grasp the front end of the power cord rather than pulling
on the power cable itself.
• Do not soak the cleaner in water or splash water on it.
• Do not operate the air cleaner near an open flame.
• Please make sure no water or other liquids, or any foreign materials enter the inlet or outlet.
• Do not obstruct the air inlet or air outlet of the air cleaner.
• To reduce the risk of electric shock, do not expose to water or rain.
• This product employs an overload protection (fuse). A blown fuse indicates an overload or short-circuit
situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing
instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse
blows, a short circuit may be present and the product should be discarded or returned to an authorized
service facility for examination and/or repair. (For UL Only).
• Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings.
Do not route the cord under furniture or appliances. Arrange the cord away from traffic areas and where it
will not be tripped over.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, if they have been given supervision or
instruction concerning use of the appliance and understand the hazards involved.
• In order to avoid unnecessary personal injury, children should be supervised to ensure that they do not play
with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
• To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
• Save these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
AG500/600 Control Panel
®

3
The gold standard for air cleaner
CONTENTS
Warning: IMPORTANT SAFETY INSTRUCTIONS 2
The Airgle® Air Cleaning System 4
Unpacking 8
Choosing a Suitable Location 9
Connecting to Power 11
Airgle®Components 12
How the Airgle® System Works 13
Using the Control Panel 14
Using the Remote Control 19
Care and Maintenance of your Airgle®Air Cleaning System 20
Component List 3
Component List
Carbon Filter
(Inside Machine)
Titanium Pro®
UV Module Casters Remote Control
(Battery Inside)
Owner’s Manual
(Warranty Cert. Inside)
Model cHEPA
Filter
AG900 1 No 1 1 4 1 1
AG800 1 1 No No 4 1 1
AG600 1
No 1 1 4 1 1
AG500 1 1
No
No 4 1 1
(Inside Machine) (Inside Machine) (Inside Machine)
HEPAfast Filter
®

4
Introduction to Airgle®
The Airgle® Air Cleaning System
Although many people do not experience extreme adverse reactions to airborne particles,
some are particularly sensitive to indoor air pollution. Most individuals have minor reactions
to pungent chemical odors in the air that often cause sneezing, watery eyes and so on.
These reactions will cease if one is removed from the presence of a chemical odor, or if the
chemical smell in the air slowly dissipates. However, for a small number of people, even tiny
amounts of air pollution can cause headaches, fainting, nausea and even endanger their
lives, depending on the cirumstances. This kind of reaction is called a chemical substance
allergy, or MCS.
We use chemical compositions in many products, both at work and at home, meaning
chemical compounds can be found everywhere. Chemical substances are derived from the
use of products made of chemical compositions, such as laundry detergent, shampoo,
perfume and furniture, outdoor air pollutants, and other chemical gases from furniture,
fireworks, clothing, carpets, and decoration materials that contain chloroform, benzene,
formaldehyde, ethanol and volatile organic compounds (VOCs).
AG500 can effectively filter these toxic airborne pollutants, along with dust, pollen, pet
dander, smoke and haze.
AG800 is most effective for those experiencing multiple or severe chemical allergies. With
more activated carbon in the Gas & Odor filter, it not only effectively removes gaseous
pollutants, such as smoke, smells, and other volatile organic compounds, but also provides a
An efficient air cleaning system plays an important role when it comes to improving indoor air
quality. However, an air cleaning system alone is not enough – it needs assistance. That's
where you come in. Controlling the sources of air pollution and making sure proper
ventilation is utilized are critical components in improving the air quality in your home or
office.
To tackle indoor air quality problems, keep these tips in mind:
• Eliminate or reduce the source of air pollution as much as you can. Locating and controlling
the source of pollution in your home directly at the source is very effective.
• Proper ventilation is extremely important. Controlling your air circulation cannot reverse the
fact that the air in your home or office is converted to carbon dioxide (CO2) every time
someone exhales. Proper ventilation will ensure that clean, fresh air is continually introduced
into the room from outside.
• The most ideal method is to use an air cleaner, such as the latest & second generation air
purification technology from Airgle Corporation. It is the best and most effective air
purification machine that can be tailored to fit your needs.
®

Titanium Pro®Module
5
Introduction to Airgle
The AG600 and AG900 come with a Titanium Pro® UV module. These modules are
considered the next generation of photocatalytic oxidation technology, and are the first
Titanium Pro® UV modules in the world, successfully developed by the Airgle team after
many years of research. The modules are configured with all of the components for air
purification through the oxidation effect of photocatalysts and UV light.
The catalytic area in the module can effectively kill bacteria and viruses, as well as safely
break down harmful chemical gases and odors.
The working principle of the Titanium Pro® UV module is that its surface is coated with a
photocatalyst. It degrades air pollutants by exposing both the pollutants and the catalyst to
the photons of UV light. The pollutants are rapidly converted into harmless substances when
the UV light energy activates the catalyst.
potent degradation of indoor decoration pollution, such as formaldehyde, benzene, etc.
Activated carbon is considered the most effective way to eliminate the harmful substances in
gaseous pollutants and air.
We have chosen to utilize the high adsorption properties of coconut shell activated carbon. Its
rich pore structure and great specific surface area remove more formaldehyde, benzene,
TVOC and other harmful gases, as well as odors, quicker and more effectively than other
available products. This brings fresher and cleaner air to individuals with multiple and severe
chemical allergies.
AG600 and AG900 remove various pollutants, including dust particles, smoke, bacteria and
viruses, VOCs, formaldehyde, etc., and are mainly used in hospitals, clinics, healthcare
facilities, laboratories, and research institutes. In the past, only medical institutions could
configure these portable ultra-high efficiency air cleaners, but now Airgle® offers these
industrial-grade machines for home use to families afflicted by air pollution and allergic
diseases. Those suffering from asthma, heavy pollen sensitivity and respiratory difficulties will
greatly benefit from this revolutionary purification technology.
Airgle's second generation medical-grade purification machine uses a cHEPA ultra-high
efficiency filter with a purification ability six to ten times greater than traditional HEPA
technology. It can filter particulate matter of less than 0.3 microns, and the filtration efficiency
can reach 99.998%. The airflow it provides is six times greater than other conventional air
cleaners on the market, and it is faster and more effective at filtering airborne dust, mold
spores, pollen, smoke, haze, animal dander and other stimulations of allergies. Its large filter
is also economically beneficial, extending the service life of the machine, and the Airgle®
AG600 and AG900 Air Cleaners use a Titanium Pro® UV component, which is one of the core
technologies of the Airgle Corporation.
®

6
Introduction to Airgle®
Airgle®
(AG500/AG800) is designed with:
The Airgle®AG500/AG800 Air Cleaning Systems
1) A Gas & Odor filter
2) A HEPAfast filter
Effectively filters airborne dust and particulate matter;
removes pollen, pet dander, smoke, haze and odors.
Decomposition of formaldehyde, toluene and other
decoration pollutants.
Our patented Titanium Pro®includes the following features:
• A catalytic metal plate, an electronic component, a UV germicidal lamp and a UV lamp
ballast, combined into a single disposable module - a handheld, unitized package, designed for
easy insertion into and removal from the air cleaner.
• Unique structural design to allow for maximum airflow, rapidly diluting the concentration of
unwanted airborne contaminants.
• 6.40 times more effective catalytic area, compared to other conversional Tio2 modules.
• 10-watt UVC lamp for AG600, 14-watt UVC lamp for AG900.
• Plug and play technology.
• Works at room temperature.
• No chemical additives.
• No residual ozone.
• High oxidation yields for gas phase reactants and odors.
• Low energy requirements.
• Works in humid conditions.
• Long service life.
®

7
Introduction to Airgle®
Airgle® (AG600/AG900) is designed with:
The Airgle® AG900 Air Cleaning Systems
1) A Gas & Odor filter
2) A cHEPA filter
3) A Titanium Pro® UV Module
The filtration efficiency is 99.998%.
Enhanced technology for the filtration of bacteria and viruses.
Removes dust, pollen, pet dander, smoke, haze and odors.
Decomposition of formaldehyde, toluene and other decoration
pollutants. Efficient removal of gaseous pollutants such as smoke,
odors, and other volatile organic compounds.
Strong degradation of indoor decoration pollution, such as
formaldehyde, benzene, and more.
Model
Net Weight
Gross Weight
Packing Size
Product Size
AG500 AG600 AG800 AG900
33.2 lbs 35.5 lbs 54.7 lbs 56.4 lbs
43.2 lbs 45.8 lbs 67.9 lbs 69.7 lbs
18.90*18.19*23.27 inches 18.90*18.19*23.27 inches
14.96*15.55*20.20 inches 14.96*15.55*20.20 inches 17.72*18.98*24.80 inches
22.40*22.40*27.48 inches
17.72*18.98*24.80 inches
22.40*22.40*27.48 inches
The Airgle®AG500/600/800/900 Air Cleaning Systems Parameters
®

8
Introduction to Airgle®
UNPACKING
Model Number: Purchase Date:QR Code:
Unpack your Airgle®System
as follows:
Pre-Installed Filters:
AG500:
HEPAFast Filter + Gas & Odor Filter
AG600:
cHEPA Filter + Gas & Odor Filter +
Titanium Pro®
出厂前预安装过滤网如下:
AG800 \ AG800S:
HEPAfast滤网+活性炭滤网
AG900 \ AG900S:
cHEPA滤网+活性炭滤网
+Titanium Pro UV 组件
AG850:
HEPAfast滤网+活性炭滤网
+Titanium Pro UV 组件
AG950:
cHEPA滤网+活性炭滤网
Pre-Installed Filters:
AG800:
HEPAFast Filter + Gas & Odor Filter
AG900:
cHEPA Filter + Gas & Odor Filter +
Titanium Pro®
AG500/600 Pre-Installed Filters View:
Titanium Pro® UV is installed horizontally
AG800/900 Pre-Installed Filters View:
Titanium Pro® UV is installed vertically
1. Remove the Airgle® Cleaner System from the packaging.
2. Do not throw the original box and packaging away. Keep it in case you need to transport the
unit again sometime in the future.
3. Check the components received against your packing slip to make sure you have all the parts.
4. Check the unit and all the components for damage. If the unit or any of the components show
damage from shipping, contact your local dealer.
5. For your future convenience, record the model information here. Model information can be
found on the name plate located on the bottom of your unit.
®

9
Introduction to Airgle®
CHOOSING A SUITABLE LOCATION
Now that you have unpacked your air cleaning
system, where are you going to use it?
Living/family rooms:
Bedrooms:
Install the supplied casters as follows:
1) Carefully insert the caster stem into receptor tube vertically.
2) Press on the caster until it aligns with the bottom. Repeat
steps 1) and 2) with the remaining casters.
3) Ensure each caster is securely fitted before placing
the machine in its upright position onto the casters.
123
Insert Vertically
Align with the bottom
Does someone in your family have allergies
and/or asthma? People with allergies and
asthma sometimes have a hard time sleeping,
as many of their symptoms worsen during the
night. Moving the air cleaning system into the
bedroom at night will help them. Be sure to
have at least one foot of space between the
system and any walls, cabinets or large
furniture to allow for better air circulation.
Placing your air cleaning system in a
central location in your largest room will
help purify throughout the entire room,
and may be mutually beneficial to other
rooms that have doorways to the main
room. Be sure to have at least one foot
of space between the system and any
walls, cabinets or large furniture to allow
for better air circulation.
®

10
Introduction to Airgle®
For optimal performance, keep these 3 things in mind:
Home office or den:
Keeping your system in your home
office or den will certainly clean the
air in that room – but probably only
that room.
Be sure to have at least one foot of
space between the system and any
walls, cabinets or large furniture to
allow for better air circulation.
Many people will turn on their air cleaner periodically throughout the day, but we recommend you
leave it on for constant air cleaning while you are using the room. After all, air pollution never takes
a break, so why should your air cleaner?
We have found that many people start with one air cleaning system and move it from room to room
throughout the day. You should focus your air cleaning efforts in the areas where you and your
family spend the most time. Some of them continue the practice of moving the air cleaner from
room to room while others purchase additional units. No matter how you end up using your system
or systems, please be sure to remember the below suggestions.
1. Position the air cleaning system at least one foot away from the wall. The more centrally the
air cleaner is positioned, the better and faster your system will purify the air.
2. Keep the power cord away from walkways.
3. Make sure you can easily access the control panel.
®

11
Introduction to Airgle®
CONNECTING TO POWER
ter
r
Make sure the cleaner is plugged into a live 110-120V AC outlet if the rated voltage specified
on the dataplate is 110-120V, or a 220-240V AC outlet if the rated voltage specified on the
dataplate is 220-240V.
Plug types may vary
After selecting the best location for your air cleaning system and clearing the space around
where it will stay, connect the power cord to the unit and the other end into the socket.
®

12
The art of purification
AIRGLE®AIR CLEANER COMPONENTS
AG500/AG800 Filter Components Showing 5 and 6 here
AG600/AG900 Filter Components showing 4, 5 and 6 here
Sensor: Monitors the amount of particles in the room to determine airflow activity (if unit is on auto).
Housing: The outside “box” for the unit. You will want to make sure this is kept clean and that no
areas, such as the sensor or air intake/outflow, become covered or blocked.
Casters: Install the casters provided with your cleaning system to make it easier to move as needed
when cleaning, as well as to keep the unit off the floor for better airflow.
Titanium Pro®: This module is easily removed when replacement is required as indicated on the
control panel. The light bulb indicator on the control panel will start blinking when the module has
reached its life of 6000 hours and requires replacement (AG600 and AG900 only).
HEPAfast Filter (cHEPA for AG600 and AG900): The filter may need to be replaced when the light
grid on the LCD control panel starts blinking. Please remove it for replacement to ensure optimal
efficiency.
Gas & Odor Filter: This filter is removable for cleaning (by vacuum) or replacement. We recommend
checking for possible cleaning every month. The filter may need to be replaced together with the
HEPAfast filter (cHEPA for AG600 and AG900).
Rear Door: Make sure the rear door is latched on correctly so as not to overload the air cleaning
system with additional air intake that is not entering the unit in the proper manner.
Auto Shut Off: This safety feature will automatically turn off the unit if the Titanium Pro® UV, HEPA
filter (cHEPA filter), or Gas & Odor filter is not installed in the unit, or if the rear door is removed while
the unit is running.
1.
2.
3.
4.
5.
6.
7.
8.
®

13
The art of purification
HOW THE AIRGLE®
SYSTEM WORKS
43
5 2
1
Purified air Air Intake
Fan
Room air is drawn into the system via the rear grill.
The process begins when air moves through the Gas & Odor filter, which captures the large
particles and VOCs that are adding to air pollution.
Next, the air moves through the HEPAfast filter, which captures tobacco smoke, dust mites,
pollen, dander, smog, mold and other airborne pollutants of a particle size greater than 0.3
microns. (For model AG600/AG900, the filter is an ultra-high performance cHEPA filter,
which quickly and effectively filters respirable particulate matter with an efficiency reaching
99.998%.)
If your unit includes the Titanium Pro® module, the air then moves through this final filter,
where additional particles are removed, and bacterial and viral organisms are destroyed.
Purified air is then returned to the room via the front grill.
1.
2.
3.
4.
5.
43
2
1
Fan
®

14
The art of purification
USING THE CONTROL PANEL
IR
USING THE CONTROL PANEL
IR
The Airgle® system is equipped with a state-of-the-art control panel. This advanced control
panel allows you to assess the unit’s status with one quick glance.
1
4
7
5
6
2
3
Mode
®

15
The art of purification
2.
Unhealthy
Change
66% Remaining
33% Remaining
Full Life
ModerateGood
Control Setting: This advanced setting is for users who encounter challenging air pollution
environments and/or needs. The default setting is Moderate, which should be ideal for most
users. For more information, please see the Control Setting section in this manual.
Light Bulb: This indicator displays if you have installed Titanium Pro®. If blinking, it indicates
that the filter needs to be replaced. For more information, please see the Titanium Pro®
section in this manual. (This function is only for models AG600 and AG900.)
Speed: This indicates the speed selected by using the knob on the right-hand side of the
panel.
Auto: This indicates you have elected to use the Auto-Mode (it is on the right side of the
panel).
Timer: This indicates how much time is left until the system shuts down (activated by the
Timer button on the right-hand side of the panel).
3.
4.
5.
6.
7.
Filter Life: This monitor calculates the remaining life of the system’s filters. The calculation
takes into account both the already elapsed operation time and fan speed. This allows for a
more accurate report on filter life. The six status bars indicate if the filter should be changed
(one bar) to when it is at its full life (six bars). When the filter needs attention, the first bar
will be blinking.
Air Quality: The Airgle® system is equipped with an advanced air quality monitoring sensor.
The Air Quality Gauge displays the quality of the air in the room – the air you breathe. The
six status bars indicate the quality from Unhealthy (one bar) to Good (six bars).
1.
®

The art of purification
1. Timer: Press this button to set the timer for up to 12 hours of continuous operation. The time shows
on the bottom right of the LCD display on the left-hand side of the panel. Timer button operation is as
follows: The machine will run for one hour if the Timer button is pressed once and the LCD displays
01:00; the machine runs for two hours if the Timer button is pressed twice and the LCD displays 02:00,
and so on up to 12 hours. The machine allows you to access the control settings if the Timer button is
pressed and held for five or more seconds. Please refer to the Control Settings on page 17 for details.
2. Mode: When you press the Mode button for AG500/AG600 (or “Auto” button for AG800/AG900), the
unit will automatically change to the optimum speed needed for air purification of the room and change
the Air Quality light bar according to air quality. The sensor (located on the side of the unit) will tell the
unit when to raise or lower the fan speed depending on the amount of particles in the room.
Sleep Mode: When you use the AG500/AG600 units, press the Mode button twice successively and
the machine will start sleep MODE. The machine will turn off all lights (including LCD & UV lamp) and
change the fan speed to “1”. Press the Mode button and hold down for five or more seconds to set the
UV lamp On/Off setting (refer to page 17 for details). Press the Mode button again to turn the light and
LCD back on. When you use the AG800/AG900 units, press the Auto button for three or more seconds
to set the panel on Sleep mode. Press the Auto button again and hold down for three or more
seconds to turn the LCD back on.
3. Reset: Press this button after you have replaced any of the filters or Titanium Pro®. This will reset
any blinking lights and set the filter life to full.
Note: This function is only activated when any of the filters require changing. If the filter life is full, the
button is disabled to prevent accidental pressing of the button.
4. Power/Speed: When the air cleaner is turned off, the “Power Off” indicator will display as red, and
the fan speed indicator will be off. To turn the system on, rotate the Power/Speed knob
counterclockwise or clockwise to select a speed from 1 to 5. The default speed for AG500/600 starts
from “1” and for AG800/
IR
1
2
3
4
5
CONTROL PANEL DETAILS: RIGHT-HAND SIDE
Mode
1617
IR
1
2
3
4
5
Auto
AG500/AG600 Control Panel AG800/AG900 Control Panel
®

17
The art of purification
The default setting for the unit is “Moderate” and will be displayed as four bars on the control panel.
This setting should meet air purification needs in most environments.
Titanium Pro®
Advanced Function Setting
900 starts from “3”. The light indicator for the selected speed will display as white and the speed
you selected will display on the left-hand side of the panel, while the “Power Off” LED indicator
light is off. To turn the system off, rotate the knob to the “Power Off” position. The “Power Off”
LED indicator will display as red, and the light indicator for the fan speed will turn off.
5. IR: This infrared receiver is used by your remote control to change unit settings.
Models AG600/AG900 include the Titanium Pro®module.
If your unit has been installed with the Titanium Pro®module, the light bulb icon will display on
your control panel. The light bulb indicates whether your unit has the module installed, and also
indicates when it is time to replace the module by blinking.
The Titanium Pro®module is designed to last 6000 hours. When that time is up, the light bulb icon
will start blinking. After you replace the filter and press the Reset button (on the right-hand side of
the panel), it will stop blinking.
If desired, the Titanium Pro®module can be turned off.
1. With the power turned on, press the Mode button (for AG600), hold down for more than five
seconds and the light bulb indicator on the LCD display will start blinking. When you use AG900,
make sure that the unit is on standby mode, press the Timer button (for AG900), hold down for
more than five seconds and the light bulb indicator on the LCD display will start blinking.
2. When the light bulb is on, press the Mode button (for AG600) or the Timer button (for AG900 )
again to turn on the Titanium Pro®module.
3. When the light bulb is off, press the Mode button (for AG600) or the Timer button (for AG900)
to turn off the Titanium Pro®module.
For advanced users only:
Control Setting
1.
2.
1. When you use Models AG500/AG600, make sure the units are powered on (plug in the units and
confirm the knob is at the “Speed 1 to 5” position). When you use models AG800/AG900, make sure
the units are on standby mode (plug in the units, and confirm the knob is at the “power off” position).
2. Press and hold the Timer button (for AG500/AG600) or the “Auto” button (for AG800/AG900) for
more than five seconds and you will hear a “ding” sound. The Control Setting bars will cycle through
High, Moderate, Low, Moderate......and then start blinking.
®

1817
The art of purification
When the unit is set on Low, the sensor (on the side of the unit) is less sensitive to the environment.
The system does not auto-activate until it senses a medium to high amount of particles in the air.
This setting extends the filter life.
What happens in High Mode?
What happens in Low Mode?
Answer the following questions to assess whether you need to change your control setting:.
Are you noticing severe indoor air pollution problems?
Are you or a member of your family having severe asthma and/or allergy issues?
Do you want to be able to always set your system to Auto mode?
Yes No
Do you have a relatively clean environment and purchased the unit for general
air purification reasons?
Yes No
If you answered “Yes” to this question, you may want to consider changing your setting to “Low”.
When the unit is set on High, the sensor (on the side of the unit) is more sensitive to the environment.
The system will auto-activate when it detects small amounts of particles in the air. Since it is more
responsive to these small amounts of particles, it will activate frequently, and this will shorten the life of
the filter. However, the air will be more pure in your room.
Auto Mode: Your system will start on high to purify the air until it senses an extremely low
concentration of particles, and then will automatically change itself to the low setting.
If you answered “Yes” to any of the questions above, you may want to consider changing your
setting to “High”. If you answered “No” consider the following question:
3. If you release the Timer button (for AG500/AG600) or the “Auto” button (for AG800/AG900)
when “High” is blinking, the system is set to High Mode.
®

19
The art of purification
USING THE REMOTE CONTROL
Use the Remote Control to:
1
2
3
4
Power: Switch the system on/off.
Mode: Change the mode to Auto or
Sleep. Press the Mode button (for
AG500/AG600) or the “Auto” button (for
AG800/AG900). You can turn on/off the
UV lamp for AG500/600 if held down for
five seconds .
Speed: Regulate fan speed from 1 to 5.
Timer: Set Timer from 1 to 12 hours.
1.
2.
3.
4.
Replacing the Remote Control Battery
1. Open the battery compartment by pressing the small lever to the side and slide the battery
compartment out.
2. Remove the used battery.
3. Insert the new battery (3V battery CR2032). Be sure that the (+) and (-) are in the correct position.
Remote Control Maintenance
1. Replace the battery if it cannot get a signal.
2. Be sure the same model battery is replaced.
3. Always put the used battery in a bag before
disposal.
4. Keep the battery away from children.
1
2
3
4
Auto
AG500/600
Remote Control
AG800/900
Remote Control
The infrared receiver of the Airgle® system is located in the right- hand bottom corner of the control
panel. In order to get the best signal transmission, the remote control should be pointed at the control
panel when pressing any button on the remote.
Note: If there are barriers between the remote and the machine, the receiver may not be able to receive
the signal. The remote control is pre-loaded with a battery. Please remove the insulation film on the
battery before use.
®

20
The art of purification
USER SERVICING INSTRUCTIONS
OF YOUR AIRGLE®
AIR CLEANING SYSTEM
Filter Removal
Open Rear Door
1pull up、
2pull out、
Your Airgle® system is equipped with a filter life monitor which will assist you in determining
when a filter needs to be replaced. If indicated, replace your filters.
Always turn off the air cleaner and unplug the power cord when performing any cleaning or
maintenance tasks.
Remove Filters and UV (AG600/900 Models)Remove Filters (AG500/800 Models)
Your Airgle® system provides access to all installed filters from the rear grill. Pull up the handle to
remove the grill and grip the pull ribbon to remove the Gas & Odor filter, HEPAfast filter, or Titanium
Pro® UV (if your model is AG600 or AG900).
®
Other manuals for AG500
1
This manual suits for next models
3
Table of contents
Other Airgle Air Cleaner manuals

Airgle
Airgle AG800 User manual

Airgle
Airgle Purepal AG950 Maintenance manual

Airgle
Airgle AG600S User manual

Airgle
Airgle PurePal AG900 User manual

Airgle
Airgle 750 User manual

Airgle
Airgle AG600 User manual

Airgle
Airgle AG500 User manual

Airgle
Airgle 750 User manual

Airgle
Airgle AG550 User manual

Airgle
Airgle PurePal AG900 User manual