Save these instructions
WARNING
Important safety instructions
Read all instructions before using this air cleaner.
When using an electrical appliance, basic precautions should always be followed, including the following:
• Make sure the local voltage used for the cleaner meets the rated voltage specified on the data plate at the
bottom of the machine. Make sure the cleaner is plugged into a live 110-120V AC outlet if the rated voltage
specified on the dataplate is 110-120V, or a 220-240V AC outlet if the rated voltage specified on the
dataplate is 220-240V.
•Always turn off and unplug the air cleaner when not in use.
• Disconnect the power supply from your air cleaner by unplugging the power cable before replacing filters,
cleaning, movement, or maintenance.
• Do not use attachments or filters not recommended by Airgle®.
• Do not use the air cleaner outdoors.
• Do not attempt to remove any part of the unit except the filters.
• Do not attempt to repair the air cleaner.
• Do not attempt to plug in the machine when your hands are wet.
• When unplugging the power cord, please be sure to grasp the front end of the power cord rather than pulling
on the power cable itself.
• Do not soak the cleaner in water or splash water on it.
• Do not operate the air cleaner near an open flame.
• Please make sure no water or other liquids, or any foreign materials enter the inlet or outlet.
• Do not obstruct the air inlet or air outlet of the air cleaner.
• To reduce the risk of electric shock, do not expose to water or rain.
• This product employs an overload protection (fuse). A blown fuse indicates an overload or short-circuit
situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing
instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse
blows, a short circuit may be present and the product should be discarded or returned to an authorized
service facility for examination and/or repair. (For UL Only).
• Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings.
Do not route the cord under furniture or appliances. Arrange the cord away from traffic areas and where it
will not be tripped over.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, if they have been given supervision or
instruction concerning use of the appliance and understand the hazards involved.
• In order to avoid unnecessary personal injury, children should be supervised to ensure that they do not play
with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
• To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
• Save these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
AG500/600 Control Panel
®

3
The gold standard for air cleaner
CONTENTS
Warning: IMPORTANT SAFETY INSTRUCTIONS 2
The Airgle® Air Cleaning System 4
Unpacking 8
Choosing a Suitable Location 9
Connecting to Power 11
Airgle®Components 12
How the Airgle® System Works 13
Using the Control Panel 14
Using the Remote Control 19
Care and Maintenance of your Airgle®Air Cleaning System 20
Component List 3
Component List
Carbon Filter
(Inside Machine)
Titanium Pro®
UV Module Casters Remote Control
(Battery Inside)
Owner’s Manual
(Warranty Cert. Inside)
Model cHEPA
Filter
AG900 1 No 1 1 4 1 1
AG800 1 1 No No 4 1 1
AG600 1
No 1 1 4 1 1
AG500 1 1
No
No 4 1 1
(Inside Machine) (Inside Machine) (Inside Machine)
HEPAfast Filter
®

4
Introduction to Airgle®
The Airgle® Air Cleaning System
Although many people do not experience extreme adverse reactions to airborne particles,
some are particularly sensitive to indoor air pollution. Most individuals have minor reactions
to pungent chemical odors in the air that often cause sneezing, watery eyes and so on.
These reactions will cease if one is removed from the presence of a chemical odor, or if the
chemical smell in the air slowly dissipates. However, for a small number of people, even tiny
amounts of air pollution can cause headaches, fainting, nausea and even endanger their
lives, depending on the cirumstances. This kind of reaction is called a chemical substance
allergy, or MCS.
We use chemical compositions in many products, both at work and at home, meaning
chemical compounds can be found everywhere. Chemical substances are derived from the
use of products made of chemical compositions, such as laundry detergent, shampoo,
perfume and furniture, outdoor air pollutants, and other chemical gases from furniture,
fireworks, clothing, carpets, and decoration materials that contain chloroform, benzene,
formaldehyde, ethanol and volatile organic compounds (VOCs).
AG500 can effectively filter these toxic airborne pollutants, along with dust, pollen, pet
dander, smoke and haze.
AG800 is most effective for those experiencing multiple or severe chemical allergies. With
more activated carbon in the Gas & Odor filter, it not only effectively removes gaseous
pollutants, such as smoke, smells, and other volatile organic compounds, but also provides a
An efficient air cleaning system plays an important role when it comes to improving indoor air
quality. However, an air cleaning system alone is not enough – it needs assistance. That's
where you come in. Controlling the sources of air pollution and making sure proper
ventilation is utilized are critical components in improving the air quality in your home or
office.
To tackle indoor air quality problems, keep these tips in mind:
• Eliminate or reduce the source of air pollution as much as you can. Locating and controlling
the source of pollution in your home directly at the source is very effective.
• Proper ventilation is extremely important. Controlling your air circulation cannot reverse the
fact that the air in your home or office is converted to carbon dioxide (CO2) every time
someone exhales. Proper ventilation will ensure that clean, fresh air is continually introduced
into the room from outside.
• The most ideal method is to use an air cleaner, such as the latest & second generation air
purification technology from Airgle Corporation. It is the best and most effective air
purification machine that can be tailored to fit your needs.
®

Titanium Pro®Module
5
Introduction to Airgle
The AG600 and AG900 come with a Titanium Pro® UV module. These modules are
considered the next generation of photocatalytic oxidation technology, and are the first
Titanium Pro® UV modules in the world, successfully developed by the Airgle team after
many years of research. The modules are configured with all of the components for air
purification through the oxidation effect of photocatalysts and UV light.
The catalytic area in the module can effectively kill bacteria and viruses, as well as safely
break down harmful chemical gases and odors.
The working principle of the Titanium Pro® UV module is that its surface is coated with a
photocatalyst. It degrades air pollutants by exposing both the pollutants and the catalyst to
the photons of UV light. The pollutants are rapidly converted into harmless substances when
the UV light energy activates the catalyst.
potent degradation of indoor decoration pollution, such as formaldehyde, benzene, etc.
Activated carbon is considered the most effective way to eliminate the harmful substances in
gaseous pollutants and air.
We have chosen to utilize the high adsorption properties of coconut shell activated carbon. Its
rich pore structure and great specific surface area remove more formaldehyde, benzene,
TVOC and other harmful gases, as well as odors, quicker and more effectively than other
available products. This brings fresher and cleaner air to individuals with multiple and severe
chemical allergies.
AG600 and AG900 remove various pollutants, including dust particles, smoke, bacteria and
viruses, VOCs, formaldehyde, etc., and are mainly used in hospitals, clinics, healthcare
facilities, laboratories, and research institutes. In the past, only medical institutions could
configure these portable ultra-high efficiency air cleaners, but now Airgle® offers these
industrial-grade machines for home use to families afflicted by air pollution and allergic
diseases. Those suffering from asthma, heavy pollen sensitivity and respiratory difficulties will
greatly benefit from this revolutionary purification technology.
Airgle's second generation medical-grade purification machine uses a cHEPA ultra-high
efficiency filter with a purification ability six to ten times greater than traditional HEPA
technology. It can filter particulate matter of less than 0.3 microns, and the filtration efficiency
can reach 99.998%. The airflow it provides is six times greater than other conventional air
cleaners on the market, and it is faster and more effective at filtering airborne dust, mold
spores, pollen, smoke, haze, animal dander and other stimulations of allergies. Its large filter
is also economically beneficial, extending the service life of the machine, and the Airgle®
AG600 and AG900 Air Cleaners use a Titanium Pro® UV component, which is one of the core
technologies of the Airgle Corporation.
®
Other manuals for AG500
1
This manual suits for next models
3
Table of contents
Other Airgle Air Cleaner manuals

Airgle
Airgle Purepal AG950 Maintenance manual

Airgle
Airgle 750 User manual

Airgle
Airgle AG600S User manual

Airgle
Airgle 750 User manual

Airgle
Airgle PurePal AG900 User manual

Airgle
Airgle AG800 User manual

Airgle
Airgle PurePal AG900 User manual

Airgle
Airgle Purepal AG950 User manual

Airgle
Airgle AG500 User manual

Airgle
Airgle AG600 User manual