-50
C3
A2
-50 A1
-50
-50
-20.0
0.1
0
0,1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0,1
0
0
0
0
0
0
0
0
99
99 99
99,9 99,9
-50
-150
99,9
150
-
-
150
-50 C2
0.0 20.0
2.0 20.0
255
2,0 20,0
1 1
1
3 99
0 1
0 255
0 120
2 3
10 120
-50 C3-SP
2 24
2 C2-SP
5 120
24 48
96
0 1
0120
0 99
30 99
0 120
0 120
0 1
1,0 20,0
0 1
5255
01
01
0 1
1 255
2 2
01
SP
C0
C1
d1
F1
F2
F3
F4
F5
d6
EP
EP
C2
C3
C5
C6
C7
C10
C11
C12
C8
C9
EP
d0
F0
A0
A1
A2
A3
A4
A5
A6
A7
A8
A10
A9
d3
d5
d7
d8
d9
d2
C4
Temperature Adjustment (Set Point)
(limits depending on probe type)
With NTC
With NTC
Calibrating probe 1 (Offset)
Probe 1 differential (Histeresis)
Probe 2 differential (If P4 ¹ 1)
Stop fans when stopping compressor 0=No, 1=Yes
Fan status during defrost: 0=Off; 1=On
Starting delay after defrost (if F3=0)
Will only operate if it is higher than d9
Defrost start delay on equipment start-up
Exit Level 1
Exit Level 1
Upper blocking of the set point
(cannot be set above this value)
Lower blocking of the set point (cannot be set below this value)
Protection delay time (value of the option selected in parameter C4)
Status of COOL relay with probe fault
0=OFF; 1=ON; 2=Average based on last 24 hours prior to probe fault;
3=ON-OFF as prog. C7 and C8
Time relay ON in case of faulty probe
(If C7=0 and C8¹0, the relay will always be OFF deenergised)
Change set point (SP) in ECO mode (SP+C12 C2) (0=off)£
Time relay OFF in case of fault of probe 1
(If C8=0 y C7¹0, the relay will always be ON energised)
Maximum duration of fast freezing mode. (0=off)
Exit Level 1
Defrost frequency (Time between two starts)
Fan shut-down temperature as per probe 2 (if P4 ¹ 1)
Configuration of temperature alarms: 0=Relative to SP; 1=Absolute
Maximum alarm probe 1 (must be greater than SP)
Minimum alarm probe 1 (must be less than SP)
Temperature alarm delay during start-up
Temperature alarm delay after completion of a defrost
Temperature alarm delay after reaching the value of A1 or A2
External alarm / Severe external alarm delay when receiving digital input signal
(P10 or P11=2 or 3)
Deactivation delay of the external alarm / Severe external alarm when the
signal of the digital input disappears (P10 or P11=2 or 3)
Show warning if defrost is terminated by time-out 0=No, 1=Yes
Temperature Alarm Differential (A1 and A2)
Alarm relay polarity 0=Relay ON in alarm (OFF no alarm)
1=Relay OFF on alarm (ON with no alarm)
Maximum duration of message (time added at the end of the defrost)
Defrost on equipment start-up
0=NO, First defrost as per d0, 1=YES, First defrost as per d6
Defrost type: 0=Resistors, 1=Inverted cycle
Calculated time between defrost periods:
0=Total actual time; 1 =Sum of times the compressor is on
Drip time at end of defrost (compressor and fans off) (if P4 ¹ 1)
Type of message during defrost: 0=Currentl temperature;
1=Temperature at start of defrost; 2=Display dEF message
Type of delay for protection of the compressor:
0=OFF/ON (since the last disconnection);
1=OFF-ON/ON-OFF (since the last shut-down /start-up)
(ºC/ºF)
(ºC/ºF)
(ºC/ºF)
(min.)
(min.)
(min.)
(ºC/ºF)
(ºC/ºF)
(min.)
(min.)
(ºC/ºF)
(h.)
(ºC/ºF)
(min.)
(h.)
(h.)
(ºC/ºF)
(ºC/ºF)
(min.)
(ºC/ºF)
(ºC/ºF)
(min.)
(min.)
(min.)
(min.)
(min.)
(min.)
With PTC
With PTC
Level 2
FAn FAN control (Evaporator)
Level 3 Description Values Min. Def. Max.
Level 1 Level 1
Menus and description Menus and description
Level 2
rE Control
Level 3 Description Values Min. Def. Max.
Level 2
dEF DEFROST Control
Level 3 Description Values Min. Def. Max.
Level 2
AL ALARMS control (visual)
Level 3 Description Values Min. Def. Max.
Temperature display mode 0=Whole in ºC 1=One decimal in ºC
2=Whole in ºF 3=One decimal in ºF
15
P6 Configuration of AUX relay 1=2nd Defrost 2=Alarm
3=Light 4=Pump down 5=Master Defrost
01
1
3
P7
0 1 3
P8 Probe to be displayed (as per parameter P4)
0=visualization of all the probes in sequence; 1=Probe 1; 2=Probe 2; 3=Probe 3
Configuring digital input 1
0= Off 1=Door contact 2=External alarm
3=Severe external alarm 4=Slave defrost 5=Act. ECO mode by pushbutton
6=Act. Fast Freezing 7= Low pressure switch 8=Remote defrost
9=Act. ECO mode by switch
Configuring digital input 2
0= Off 1=Door contact 2=External alarm
3=Severe external alarm 4=Slave defrost 5=Act. ECO mode by pushbutton
6=Act. Fast Freezing 7=Not used 8=Remote defrost
9=Act. ECO mode by switch
00 1
P9 Selection of probe type 0=NTC; 1=PTC
-
-
0
0
0
- 99
0
0
9
9
L5
PU
Pr
EP
EP
EP
P10
P11
Access code (Password)
Program version (Information)
Program revision (Information)
Exit Level 1
Exit Level 1
Exit Programming
0
0
0 1
0 1
P12
P13
Digital input polarity 1 0=Energised on closed contact, 1=Energised on open contact
Digital input polarity 2 0=Energised on closed contact, 1=Energised on open contact
Level 2
tid Control Acceso e Información
Level 3 Descripción Valores Min. Def. Max.
L5
E1
E2
E3
dEF
AH
AL
AE
AES
Adt
PAb
LP
Pd
MESSAGES
D
D: Displays the message on the display, A: Activates the alarm relay (if available).
S: Message expressed in the software AKONet
D
D
D
D
D
D
D
D
D
D
D
D
A
A
A
A
A
A
A
S
S
S
S
S
S
S
S
S
S
S
S
Access code (Password) request
Probe 1 faulty (open circuit, crossover or temperature outside the probe limits)
Probe 2 faulty (open circuit, crossover or temperature outside the probe limits)
Probe 3 faulty (open circuit, crossover or temperature outside the probe limits)
Indicates a defrost is underway. (Only if parameter d2=2)
Flashing: maximum temperature alarm on probe 1 (A1)
Flashing: minimum temperature alarm on probe 1 (A2)
External alarm activated (only if parameter P10 or P11=2)
Severe external alarm activated (only if parameter P10 or P11=3)
Defrost time-out alarm (only if parameter A8=1)
Door open alarm (Only if P10 or P11=1 and as per time at A12)
Pump down malfunction error (Start-up).
Pump down malfunction error (Stop).
d10
d11
d12
d13
d14
d15
1st defrost start time (RTC required)
2nd defrost start time (RTC required)
3rd defrost start time (RTC required)
4th defrost start time (RTC required)
5th defrost start time (RTC required)
6th defrost start time (RTC required)
(h.)
(h.)
(h.)
(h.)
(h.)
(h.)
00 Off
00 Off
00 Off
00 Off
00 Off
00 Off
23
23
23
23
23
23
P14
P15
Maximum start-up time after pump down
(Values between 1 and 9 seconds are not accepted)
Maximum pump down time (min.)
(Sec.) 0 0
00
120
15
0
0
0 255
2 120
EP
P1
A12
Exit Level 1
Delay of all functions on receiving electrical power
Door open alarm delay (if P10 or P11=1)
(min.)
(min.)
Level 2
CnF General status
Level 3 Description Values Min. Def. Max.
1 1 3
P4 Selection of type of inputs 1=1 probe + 2 digital inputs;
2=2 probes +1 digital input; 3=3 probes
P5 MODBUS address 1 1 255
r1
r2
EP
Clock configuration: HOUR
Clock configuration: MINUTES
Exit Level 1
(h.)
(min.)
Level 2
Level 2
rtC REAL TIME CLOCK Parameters (RTC required)
Access and information control
Level 3
Level 3
Description
Description
Values
Values
0 0
0 0
23
59
Min.
Min.
Def.
Def.
Max.
Max.
Change set point (SP) in fast freezing mode, when it reaches this point (SP + C10)
returns to normal. (SP+C10 ³ C3) (0=OFF)
Length of inactivity at digital input to activate ECO mode
(Only if P10 or P11=1 and P0=0) (0=OFF)
Maximum defrost duration (0=defrost deactivated)
Stop fans on opening the door 0=No, 1=Yes
(Requires a digital input configured as port P10 or P11=1)
7- Technical specifications
Power supply
Maximum Voltage SELV circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Comunication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus RTU Rs485
Inputs (According to P4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 entradas NTC/PTC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 inputs NTC/PTC + 1 digital input
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 input NTC/PTC + 2 digital inputs
Relay 16 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 12(9) A 250 V~)
Relay 6 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 5(4) A 250 V~)
Relay 8 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 8(4) A 250 V~)
Number of relay operations. . . . . . . . . . . . . . . . . . . . . . . . . . . EN60730-1: 100.000 operations
Types of probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTC AKO-149xx / PTC AKO-1558xx
Measurement range NTC . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +99,9 ºC (-58,0 ºF to 211 ºF)
PTC . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +150 ºC (-58,0 ºF to 302 ºF)
Resolution -50 to 100 ºC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 ºC
> 100 ºC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ºC
Working environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10 to 50 ºC, humidity <90 %
Ambient storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30 to 70 ºC, humidity <90 %
Class of protection - front panell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
Fixation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Panel-mounted with anchors
Panel cutout dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 x 29 mm
Front panel dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 x 38 mm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 mm
Connections. . . . . . . . . . . . . . . . . . . . Connections via screw terminals for cables up to 2.5 mm²
Rating of control device: built-in, automatic operation feature Type 1.B, for use in clean
environments, Class A software and continuous operation. Pollution classification 2 s / UNE-EN
60730-1.
Double insulation between supply, secondary circuit and relay output.
Rated pulse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
Temperature during ball-pressure test Accessible parts. . . . . . . . . . . . . . . . . . . . . . . . . 75 ºC
Parts which position active elements . . . . . . . . . 125 ºC
Voltage and current as per EMC test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 V, 17 mA
Current of radio jamming supression tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz 7 VA90-240 V ~
Ar D S
Clock battery discharged or clock deprogrammed
(ºC/ºF)
With NTC (ºC/ºF)
With PTC
0 0 2
P2 Access code (password) functions
0=Inactive; 1=Block access to parameters; 2=Keyboard lock
P19 Lights in ECO Mode (P6=3) 0=ON; 1=OFF 001
-50 8 99,9
d4 Defrost end temperature (probe 2) (If P4 ¹ 1) (ºC/ºF)
6 - Table of parameters and messages
Def. column shows factory-set default parameters. Those marked with * are variable parameters depending on the application chosen in the wizard or the P3 parameter (see table "Default parameters
by application"). Unless otherwise stated, temperatures are expressed in °C.