ALBIN PUMP Marine Defroster 9 kW User manual

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 1 (16)
Instruction for use
Marine Defroster 9 kW 6 Outlets

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 2 (16)
This instruction for use is structured according to the European Commission
COUNCIL RESOLUTION (98/C 411/01) of 17 December 1998 on operating instructions for
technical consumer goods.
Albin Pump Marine defrosters are designed and manufactured to the highest standards of
reliability and safety.
The contentof thismanualis inaccordance with the design and construction of theequipment
at the time of publishing. Albin Pump Marine reserves the right to introduce design
modifications without prior notice.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 3 (16)
Table of Contents
1. Introduction..................................................................................................................4
1.1. Intended use of product............................................................................................4
1.2. General description of product .................................................................................4
1.3. Main function of product...........................................................................................4
2. Safety information........................................................................................................5
2.1. Warnings..................................................................................................................5
3. Technical data.............................................................................................................6
4. Handling ......................................................................................................................7
5. Preparing for use and installation.................................................................................7
5.1. Defroster..................................................................................................................7
5.2. Control panel............................................................................................................8
5.3. Electrical connection ................................................................................................8
5.3.1. Pinning..............................................................................................................9
5.4. Water connection...................................................................................................10
5.5. Air connection ........................................................................................................11
6. Operation...................................................................................................................12
6.1. Control panel..........................................................................................................12
7. Maintenance..............................................................................................................12
8. Troubleshooting.........................................................................................................13
9. Consumables and spare parts...................................................................................13
9.1. Consumables.........................................................................................................13
9.2. Spare parts ............................................................................................................14
10. Packaging and product recycling ...............................................................................14

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 4 (16)
1.Introduction
1.1. Intended use of product
This equipment is intended for use in marine environment, incorporated in marine vessels.
The equipment is not designed for use and operation in explosive environments.
This product has been designed and manufactured for the purpose to provide heated air
during normal working conditions.
1.2. General description of product
This product comprises mainly of metal casing, heat exchanger and blower. Detailed
information about ingoing components can be found in drawings and schematics. Purpose of
the product is to heat up air passing through the unit and distribute it through air ducts to
desired locations.
1.3. Main function of product
Main function of the product is to heat and circulate the air by means of heat exchanger
connecter to water-based system and electrical blower. Air is sucked through inlets located
either on bottom or sides of the product and ejected through outlets located on top.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 5 (16)
2.Safety information
This productmust only be operated, maintained and repaired by personnelwho
have been informed of the residual risks involved in operating it, and who have
been warned of the risks involved if not following the instructions in this manual.
No modifications to the product are allowed without consulting the
manufacturer.
Read and understand the manual before using this equipment!
Hazardous voltage may shock and burn. The power supply must be securely
turned off before any maintenance is performed inside the electrical powered
equipment on the product.
Familiarize yourself with the proper operation of any service equipment you will be using.
Always read the manual enclosed with the equipment, and always follow the manufacturer
instructions. Failure to do so could cause personal injury or damage to your equipment. Never
perform any maintenance or service on your equipment before consulting authorized service
personnel. Always unplug unit before any maintenance.
Always use appropriate protective equipment, wear goggles and gloves.
Always work in pairs. Never work on the equipment alone.
2.1. Warnings
Do not perform any work on the system unless power is turned off!
Do not put body parts or clothes etc. into blower fans, unless power supply is
disconnected!
Immediately turn of the system in case of any suspicion of malfunction!

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 6 (16)
3.Technical data
Parameter
Value
Part number
09-02-017 kit
09-02-015 unit
09-02-018 kit
09-02-016 unit
Description
Premium defroster 9 kW
12V 6 Outlets
Premium defroster 9 kW
24V 6 Outlets
Rated heating performance (max)
9 kW (31000 BTU/h)
Rated air flow (max)
350 m3/h (206 cfm)
Rated voltage
12 V DC
24 V DC
Rated power consumption
Hi
9,0 A
4,5 A
Med
6,0 A
3,5 A
Low
5,0 A
3,0 A
Electrical connection (unit)
AMP Faston 6.3 4-pole female, AMP 180901
Electrical connection (extension
cable)
AMP Faston 6.3 2-pole female, AMP 180908
Fuse (not included)
15 A
10 A
Water connection
16 mm (5/8”) copper pipes with DIN 71550 bead
Water pressure (max)
2,5 bar (36 psi)
Air connection
Inlet
2 plastic hose adapters for Φ90 mm (3.5”) air hoses
(can be moved to the sides of unit)
Outlet
6 plastic hose adapters for Φ60 mm (2.4”) air hoses
6 plastic hose adapters for Φ63,5 mm (2.5”) air
hoses
Noise level (max)
70 db(A)
Dimensions (WxHxD)
Width
440x136x365 mm (17.3”x5.4”x14.4”)
Weight
5,5 kg (12,1 lb)

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 7 (16)
4.Handling
Product is packed in carton box and can be handled by any available means, due to its low
weight and size.
Wear protective gloves to prevent any cuts from possible sharp edges.
Do not carry the product holding it either by the cable harness or by water
connection tubes.
5.Preparing for use and installation
Unpack the equipment and start mounting the unit as described below. Also check with
instructions from vessel manufacturer.
5.1. Defroster
Securely mount defroster in one of following positions (vertical or horizontal) by means of
adequate screws or bolts and 4 slots in defroster’s casing (not included).

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 8 (16)
Following mounting positions (vertical blower axis) are possible, but not recommended.
Product will operate in such position, however longevity of blower will be decreased.
5.2. Control panel
Mount control panel in designated place by means of suitable screws or bolts (not included).
Control panel has four Φ4,5 mm (0,18”) holes shown below.
5.3. Electrical connection
Connect the unit directly or by means of extension cable to the vessel’s power supply with
adequate voltage, using matching connectors (see section 3for details). Connect control panel
to extension cable.
Make sure that wires with cross section of at least 2,5 mm2(AWG 13) are used
to connect the unit to power supply.
Make sure that all connectors are properly connected and will not become
loose during normal operation.
Make sure defroster’s electrical circuit is fused with appropriately sized fuse
(see section 3).
Make sure that defroster is connected to adequate power supply with voltage
matching rated voltage of defroster. Incorrect connection can damage product.
We recommend applying technical vaseline to additionally protect electrical connectors
against moisture and dirt.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 9 (16)
5.3.1. Pinning
Positions in each connector given in this instruction are matching markings on connectors
and related manufacturer’s documentation.
Main connector pinning is as follow:
1. High speed
2. Medium speed
3. Low speed
4. Ground
Extension cable pinning is as follow:
1. Power
2. Ground
Control panel pinning is as follow:
H High speed
M Medium speed
L Low speed
B Power
C Clutch (common out), not used
Please also refer to wiring schematic for additional information.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 10 (16)
5.4. Water connection
Product is connected to water-based system by means of two 5/8” (outer diameter, ≈16 mm)
copper pipes with beads according to DIN 71550 standard.
Appropriate set of hoses and hose clamps should be used to connect the product to the
system.
Make sure that hose clamps are mounted according to recommendation from manufacturer
in order to avoid any leakages or malfunctions. Pay attention to proper tightening torque and
positioning of clamps.
It does not matter which pipe will be used as inlet and which as outlet.
To ensure best performance, mount the product below water level in storage tank.
Water connection

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 11 (16)
5.5. Air connection
Securely connect air hoses to plastic hose adapters on both inlet and outlet sides.
Make sure that air hoses are affixed tightly to adapters by means of adequate clamps to
prevent any air leakages and loss of performance.
If needed, inlet adapters can be moved to sides of the unit, by removing two blinds covers
mounted on both sides of the unit and replacing them with inlet adapters from bottom side of
the unit. Blind covers must be fixed again to inlets on bottom of theunit. Otherwise performance
of the unit will be greatly lowered. Figure below shows unit with side-mounted inlet adapters.
6x connection for Φ63,5 mm (2,5”) or Φ60 mm (2,4”) air hoses,
air outlet side
2x connection for Φ90 mm (3,5”) air hoses, air inlet side

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 12 (16)
6.Operation
6.1. Control panel
Heater can be run in different blower speeds or turned off completely. Use knob in control
panel to set desired blower speed.
Possible speeds to select from:
•0 –blower turned off
•1 –blower runs in low speed
•2 –blower runs in medium speed
•3 –blower runs in high speed
Refer to water valve manual or vessel manual to get instructions how to regulate fluid flow.
7.Maintenance
It is recommended to perform following check-up before and after each season:
▪Control that blower works normally, does not make any unusual noise and does not
vibrate more than normal
▪Control electrical connectors and make sure that they did not become loose,damaged
or rusted
▪Control hose clamps and make sure they are securely holding hoses; if needed, re-
tighten them, following clamp’s manufacturer’s recommendations
If any malfunction is noticed, please refer to Spare parts section for list of available spare
parts or replace faulty product, if spare parts are not available for faulty component.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 13 (16)
8.Troubleshooting
#
Malfunction
Possible cause
Action
1
Unusual noise from the
blower motor
The blower motor might
not operate correctly
Replace blower.
Contact technical service!
2
Insufficient airflow
Obstruction: dust, dirt
Remove obstructions from
inlets, air ducts or filter.
Air leakage
Check duct connections
and their condition
(cracks).
Contact technical service!
3
No airflow
Jammed blower fan
Remove obstruction.
No power supply to blower
Check electrical
connections.
Contact technical service!
Broken blower or blower
motor
Replace blower.
Contact technical service!
4
Insufficient heating
Electrical connections
Check wiring and
connections.
Contact technical service!
Broken electrical
components
Contact technical service!
9.Consumables and spare parts
Following list of spare parts is suggested by Albin Pump Marine.
Albin Pump Marine may not be considered liable of possible damages caused from faulty
spare parts, if the spare parts are:
▪Not supplied by Albin Pump Marine
▪Not correctly installed according to the drawings, instructions or in any way not
installed following the rules of “good technique”
▪Not been correctly used
▪Unsecured
For other spare parts than listed below the replacement shall be made under approval of Albin
Pump Marine. Otherwise any guaranties are not valid.
9.1. Consumables
No consumables were identified.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 14 (16)
9.2. Spare parts
Following parts are available as spare parts.
APM P/N
Description
Note
09-66-023
Air hose adapter Φ60 mm (2,4”), snap-in
09-66-034
Air hose adapter Φ63,5 mm (2,5”), snap-in
09-66-022
Air hose adapter Φ90 mm (3,5”)
09-66-025
Blind cover Φ90 mm (3,5”)
09-66-026
Blower, 12V, standard
Blower cable excluded
09-66-027
Blower, 24V, standard
Blower cable excluded
09-66-017
Control panel, 12-24V
09-66-028
Knob
09-66-029
Switch, 12-24V, 4-step
09-66-020
Extension cable, 5 m (16,4 ft), 12-24V
09-66-030
Blower cable, 12-24V
10. Packaging and product recycling
The packaging must be submitted to the nearest environmental recycling center.
The product cannot be treated as household waste. It shall instead be left at a collection site
for recycling of electrical- and electronic components.
For further Recycling information, contact your local authorities, waste collection service.

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 15 (16)

Instruction for use
Original version Marine Defroster 9 kW 6 Outlets
PRD0395D01en www.albinpumpmarine.com 16 (16)
Albin Pump Marine AB
55302 Jönköping, Sweden www.albinpumpmarine.com
Other manuals for Marine Defroster 9 kW
1
Table of contents
Other ALBIN PUMP Marine Equipment manuals