Installation/Operation
www.comlaundry.com
FWF12C
Roll Heated
Flatwork Finisher
13 inch (325 mm) Roll Models
Refer to Page 4 for Model Identification
Part No. 1300003ENR8
July 2012
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
FWF12C


© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT1300003 (EN) 1
IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the
finisher operator smells gas. The gas utility instructions plus the SAFETY and WARNINGS note directly
above must be posted in a prominent location near the finisher.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Clear the room, building or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
W052
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage, personal injury or death.
W033
WARNING
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
W053

© Copyright 2012, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
21300003 (EN)
Table of
Contents
Introduction......................................................................................... 4
Serial Plate Location............................................................................. 4
Replacement Parts ................................................................................ 4
Customer Service.................................................................................. 4
Model Identification ............................................................................. 4
Safety Information.............................................................................. 5
Explanation of Safety Messages........................................................... 5
Safety Notice ........................................................................................ 8
Important Safety Instructions ............................................................... 8
Installation........................................................................................... 10
Pre-Installation Inspection .................................................................... 10
Overall Dimensions and Connecting Data ........................................... 11
Required Materials................................................................................ 12
Location Requirements......................................................................... 12
Lifting the Finisher ............................................................................... 12
Moving the Finisher with Rollers ......................................................... 13
Electrical Requirements........................................................................ 15
Grounding Instructions .................................................................... 15
Electrical Connection....................................................................... 16
Gas Connection..................................................................................... 17
Gas Technical Specifications for CE Models .................................. 18
Inlet Pressure.................................................................................... 18
Manifold Pressure ............................................................................ 18
Gas Conversion..................................................................................... 19
Adjustments and Flow Rates for Non-CE Models .......................... 20
Adjustments and Flow Rates for CE Models................................... 20
Exhaust Requirements .......................................................................... 21
Individual Venting ........................................................................... 22
First Start-Up ........................................................................................ 23
Operation............................................................................................. 25
Operating Instructions for
Microprocessor Models Starting October 2003 ................................. 25
Operating Controls........................................................................... 25
Pre-Operating Procedures ................................................................ 26
Operating Instructions ..................................................................... 26
Operating Instructions for
Electromechanical Models Through September 2003 ....................... 28
Operating Controls........................................................................... 28
Pre-Operating Procedures ................................................................ 29
Operating Instructions...................................................................... 29
Regulating the Cylinder Heat........................................................... 30
Breakdown Procedures ......................................................................... 31
Alarms .................................................................................................. 31
Insufficient Air Flow (Gas Models Only)........................................ 31
Emergency Safety Bar ..................................................................... 31
Thermal Warning Fan ...................................................................... 32
Speed Regulator Alarm.................................................................... 32

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT1300003 (EN) 3
No Flame (CE Gas Models Only).................................................... 32
Overheating or Sensor Not Connected ............................................ 32
Extended Periods of Non-Use .............................................................. 32
Maintenance ........................................................................................ 33
Check Operation of Air Vacuum Switches .......................................... 33
Feeding Ribbon Tension Adjustment ................................................... 33
Return Ribbon Tension Adjustment ..................................................... 34
Press-Roller Pressure Adjustment ........................................................ 35
Press-Roller Drive Chain Tension Adjustment .................................... 35
Thermostat Inspection .......................................................................... 36
Cleaning the Scrapers ........................................................................... 36
Waxing the Ironing Cylinder................................................................ 36
Removing Rust From Ironing Cylinder................................................ 37
Periodic Maintenance ........................................................................... 37
Daily................................................................................................. 37
Weekly ............................................................................................. 37
Every 200 Hours .............................................................................. 37
Every 2000 Hours ............................................................................ 37
Replacement of Feeding Ribbons......................................................... 38
Replacement of Return Ribbons........................................................... 40
Replacement of Supporting Rollers...................................................... 41
Replacement of Side Rollers ................................................................ 41
Troubleshooting Undesirable Finishes ................................................. 42
Troubleshooting Hot Surface Ignition Module
(120 Volt Gas Models Only).............................................................. 43
Status LED Used to Troubleshoot ................................................... 43
Ignition System Checks ................................................................... 44

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1300003 (EN)
4
Introduction
Serial Plate Location
The serial plate is located on the left side panel of the
finisher. Refer to Figure 1. Always provide the
machine’s serial number and model number when
ordering parts or when seeking technical assistance.
Replacement Parts
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
Customer Service
For technical assistance, contact your distributor or
call the following number:
(920) 748-3121
Ripon, Wisconsin
Model Identification
Information in this manual is applicable to the models
listed below.
FWF12C
1Serial Plate
Figure 1
FWF12C
1
UD13F063
UD13F078
UD13F079
UD13F126

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 5
1300003 (EN)
Safety Information
Explanation of Safety Messages
Throughout this manual and on machine decals, you
will find precautionary statements (“DANGER,”
“WARNING,” and “CAUTION”) followed by specific
instructions. These precautions are intended for the
personal safety of the operator, user, servicer, and
those maintaining the machine.
Additional precautionary statements (“IMPORTANT”
and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
Safety signs and labels are also placed on the unit.
Those signs and labels are limited messages. Where
needed, further explanations are provided below.
These signs are to be inspected for readability and
replaced when missing, damaged, or unreadable. Refer
to the Maintenance section of this manual for the
periodic maintenance schedule. Refer to the parts
manual for ordering information.
Indicates an imminently hazardous
situation that, if not avoided, will cause
severe personal injury or death.
DANGER
Indicates a hazardous situation that, if not
avoided, could cause severe personal
injury or death.
WARNING
Indicates a hazardous situation that, if not
avoided, may cause minor or moderate
personal injury or property damage.
CAUTION
To prevent serious injury
or death, read machine
manuals before installing,
operating, servicing or
clean machine.
ATTENTION
WARNING
Dans le but d'éviter tous
risques d’accidents, lire
le manuel avant installation,
utilisation, maintenance ou
entretien de la machine.
ATENCION
Para evitar todo riesgo de
de accidente, leer el
manual antes instalacion,
utilizacion, limpieza
de la maquina.
W811
W811
W807
WARNING
CUIDADO
ATTENTION
Hot rollers can catch hand or clothing and
cause severe injury.
Immediately shut off heat and power before attempting to free
jammed flatwork. Do not contact moving rolls or heated parts.
Los rodillos calientes pueden atraparle la mano o las
prendas y causar lesiones graves.
Deconecte immediatamente la calefaccion or y la electricidad
antes de intentar extraer la ropa atascada. No toque los
rodillos en movimiento ni las piezas calientes.
Les rouleauz chauds peuvent attraper les mains et les
vêtements et causer de sévères blessures.
Stopper immédiatement le chauffage et l’énergie avant
d’essayer de libérer le linge. Ne jamais être en contact
avec les rouleaux en rotation ou les éléments chauds.
W807

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Safety Information
1300003 (EN)
6
W808
WARNING
CUIDADO
ATTENTION
DISCONNECT POWER AND OTHER
UTILITIES BEFORE SERVICING REMOVING
JAMS ADJUSTING OR OTHERWISE
WORKING ON THIS EQUIPMENT.
DO NOT OPERATE WITHOUT GUARDS.
DESCONECTE LA ENERGIA Y UTILIDADES
ANTES DE EFECTUAR SERVICIOS.
EXTRAER PRENDAS ATASCADAS.
NO OPERE SIN SEGURIDADES.
DECONNECTER L’ELECTRICITE ET AUTRE
ENERGIE AVANTTOUTE INTERVENTION
DE MAINTENANCE SUR CET APPAREIL.
NE JAMAIS TRAVAILLER SANS LES
SECURITES PREVUES SUR
CETTE MACHINE.
W809
WARNING
AVERTISSEMENTAVERTISSEMENT
This dryer-ironerThis dryer-ironer
must be exhaustedmust be exhausted
to the outdoors.to the outdoors.
L’évacuation de laL’évacuation de la
séc heuse doitséc heuse doit
s’eectuer verss’eectuer vers
l’extérieur.l’extérieur.
Aprés installation,Aprés installation,
le conduitle conduit
d’évacuation doitd’évacuation doit
être vérié etêtre vérié et
nettoyé tous lesnettoyé tous les
trois mois selontrois mois selon
besoin.besoin.
Ne pas fausserNe pas fausser
le dispositifle dispositif
d’assemblaged’assemblage
pendant l’installationpendant l’installation
du conduitdu conduit
d’évacuation.d’évacuation.
S’assurer que leS’assurer que le
moteur demoteur de
ventilation tourneventilation tourne
dans le bon sensdans le bon sens
(éche du moteur).(éche du moteur).
Exhaust ductworkExhaust ductwork
should be examinedshould be examined
and cleaned, ifand cleaned, if
necessary, everynecessary, every
three months aerthree months aer
installation.installation.
Do not distortDo not distort
thimble whenthimble when
installing ductwork.installing ductwork.
Make sure thimbleMake sure thimble
vanes open andvanes open and
close freely aerclose freely aer
ductwork hasductwork has
been installed.been installed.
W812
HIGH VOLTAGE INSIDE
DISCONNECT MAIN POWER BEFORE
REMOVING COVER. ONLY SPECIALLY
TRAINED PERSONNEL SHOULD TURN
POWER ON WHEN COVER IS REMOVED.
WARNING!
HAUTE TENSION A L’INTERIEURHAUTE TENSION A L’INTERIEUR
COUPER L’ALIMENTATION ELECTRIQUE
AVANT DE RETIRER CE PANNEAU.
SEULEMENT UN TECHNICIEN QUALIFIE
PEUT REMMETTRE SOUS TENSION
APRES AVOIR REMONTE CE PANNEAU.
ATTENTION!

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Safety Information
7
1300003 (EN)
FWF136N
FWF136N
FWF137N
PUSH TO STOP IRONER
PRESIONE PARA PARAR
POUSSER POUR ARRÊTER LA MACHINE
FWF137N
W813
ATTENTION
Se reporter á la notice d’entretien.
– Utiliser impérativement toute la longueur du cylindre. Pour petites piéces, engager alternativement de
gauche à droite.
– Ne jamais arrèter la machine à plus de 80 degrés. Laisser refroidir en marche avant arrét complet.
– Cette machine nécessite un entretien minimum et régulier. Avant chaque mise en route, vérifier le bon
contact du support sonde avec le cylindre. Au maximum, toutes les 200 heures, il est impératif:
– de nettoyer les ventilateurs,
– de vérifier la propretê des conduits d’extraction,
– de graisser les chaines, poulies et paliers,
– de vérifier la tension des sangles d’engagements et de repassage.
– Please use the entire length of the cylinder. For small pieces, feed alternating
from the left to right.
– Never stop the machine when temperature is over 80 Celsius (176 Fahrenheit). Cool down the machine
before switching it off.
– This machine needs minimum and regular maintenance. Before each start up check the contact
between the thermostat probe bearer and the cylinder. Every 200 hours of work, it is imperative to:
– Check and clean venting.
– Lubricate the chains, the pulleys and the bearings.
– Check the tension of the feeding on ironing belts.
IMPORTANT
Please read the maintenance book for complete information.
– Utilizar toda la longitud del cilindro. Introducir las piezas pequeñas de ropa alternado de izquierda
a derecha.
– No parar la maquina cor una temperatura superior a 80C. Enfriar la maquina antes de deteneria.
– Esta maquina necesita un mantenimiento minimo y regular. Antes de cada empleo comprobar is
limpieza entre el soporte des termostato y el cilindro. Cada 200 horas de trabajo es necesario:
– Limpiar la ventilacion.
– Comprobar la limpieza de los tubos de extraccion.
– Engrasar las cadenas, poleas y rodamientos.
– Comprobar la tension de las bandas de entrada y de planchado.
IMPORTANTE
Leer el libro de mantenimiento.
ACHTUNG
Bitte die technische Beschreibung lesen.
– Bitte nutzen Sie die ganze Zylinderlänge. Für kleinen Stück, alternativ links zu recht einsetzen.
– Die Maschine nie über 80C außer Betrieb setzen. Bitte die Maschien abkühlen lassen bevor stoppen.
– Diese Maschine braucht regelmäßige und Minsdestwrtung. Ver jeden Starten, Kontakt des
Temperaturfühler mit dem Zylinder prüfen. Jede 200 arbeitstunden ist es wichtig:
– die Entlüftungen zu reinigen,
– die Dünste Abzug zu prüfen und reinigen
– die Ketten, Rollen und lager zu ölen,
– den Druck von Einsatz-und Bügelbändern zu prüfen.
FWF138N
ARRET D’URGENCE – STOP – EMERGENCY

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Safety Information
1300003 (EN)
8
Safety Notice
CAUTION: Note for installation.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA 70, or Canadian
Electrical Code, CSA C22.1.
The installation must comply with local codes or, in
the absence of local codes, with the current National
Fuel Gas Code, ANSI Z22.1, or the current CAN/CSA
B149, Installation Codes.
The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply
piping system by closing the equipment shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
The installation must include a 1/8 NPT pressure tap
accessible for test gage connection immediately
upstream of the gas supply connection to the finisher.
There must be provisions for adequate combustion and
ventilation air, clearance around air openings intake
combustion chamber and accessibility clearances for
servicing and operation.
Important Safety Instructions
Save These Instructions
1. Read all instructions before using the finisher.
2. Refer to the Grounding Instructions for the
proper grounding of the finisher.
3. Do not iron articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry cleaning solvents, or other
flammable or explosive substances as they give
off vapors that could ignite or explode.
4. Do not allow children to play on or around the
finisher. Close supervision of children is
necessary when the finisher is used near children.
This is a safety rule for all appliances.
5. Check the operation of the safety finger guard at
the beginning of every shift. Operating the safety
guard should stop the finisher immediately. If this
safety feature is not working properly, employees
must shut off the finisher and notify the
supervisor. Do not operate the finisher until the
safety finger guard is repaired and working
properly. Be sure that all other safety features,
including guards and panels, are in place before
operating the finisher.
• Failure to install, maintain, and/or operate this machine according to the manufacturer’s
instructions may result in conditions which can produce serious injury, death, and/or
property damage.
• Do not repair or replace any part of the machine or attempt any servicing unless specifically
recommended or published in this Installation/Operation Manual and that you are qualified
to carry out.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded and to reduce the risk of fire,
electric shock, serious injury, or death.
W566
•
WARNING
WARNING
To reduce the risk of fire, electric shock,
serious injury or death to persons when
using your flatwork finisher, read and
follow these basic precautions:
W541

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Safety Information
9
1300003 (EN)
6. Never service the finisher while it is running.
Never reach over, under, or behind the safety
finger guard or into any area near hot surfaces or
moving parts without first shutting off the
finisher at the switch and power source. Follow
this rule whenever working on the finisher to
avoid serious injury from the finisher’s heat and/
or pressure.
7. Never try to remove, adjust, or straighten
jammed or misfed linen while the finisher is
running. Attempting to clear the jammed linen
item can result in the user being caught in the
linen and pulled into the finisher. If something is
jammed in the finisher, turn off the power before
attempting to correct the problem. Avoid contact
with heated parts.
8. Protect yourself and fellow workers by making
sure that everyone follows all the rules. Read and
follow all safety labels and warnings. Learn all
aspects of the equipment such as what is hot,
which parts move, all safety shut-offs, and all
emergency procedures. Do not come close to
moving or heated parts. Do not wear loose
clothing, sweaters, jewelry, or neck ties when
near the finisher.
9. Frequent scheduled safety meetings are a must to
review and update rules. If anyone is observed
breaking the rules, the supervisor or manager
should be notified immediately. Reporting people
for rule breaking could save their lives or limbs.
10. Emergency shut-offs such as finger bars and
emergency stop switches, should be painted red
and clearly labeled.
11. Maintenance personnel should work in a buddy
system for mutual protection when working on a
finisher.
12. If in doubt, don’t. Do not do anything until the
supervisor or service-maintenance department
has been contacted. Only qualified personnel
should service the finisher.
13. Do not install or store the finisher where it will be
exposed to water and/or weather.
14. Do not tamper with the controls.
15. Do not repair or replace any part of the finisher or
attempt any servicing unless specifically
recommended in this installation/operation
manual.
16. To reduce the risk of fire, DO NOT IRON
plastics or articles containing foam rubber or
similarly textured rubber-like materials.
17. Keep area around the exhaust opening and
adjacent surrounding area free from the
accumulation of lint, dust, and dirt.
18. The interior of the finisher and the exhaust duct
should be cleaned periodically by qualified
service personnel.
19. If not installed, operated, and maintained in
accordance with the manufacturer’s instructions
or if there is damage to or mishandling of this
product’s components, use of this product could
expose you to substances in the fuel or from fuel
combustion which can cause death or serious
illness and which are known to the State of
California to cause cancer, birth defects, or other
reproductive harm.
20. Do not put articles soiled with vegetable or
cooking oil in the finisher, as these oils may not
be removed during washing. Due to the
remaining oil, the fabric may catch on fire by
itself.
21. To reduce the risk of fire, DO NOT put articles
which have traces of any flammable substances
such as machine oil, flammable chemicals,
thinner, etc. or anything containing wax or
chemicals such as in mops and cleaning cloths, or
anything dry-cleaned at home with dry-cleaning
solvent in the finisher.
22. ALWAYS disconnect the electrical power to the
finisher before servicing. Disconnect power by
shutting off appropriate breaker or fuse.
23. Install this finisher according to the Installation
instructions in this manual. All connections for
electrical power, grounding, and gas supply must
comply with local codes and be made by licensed
personnel when required.
To prevent serious injury or death, read
finisher manuals before installing,
operating, maintaining, or cleaning the
finisher.
W542
WARNING

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1300003 (EN)
10
Installation
Pre-Installation Inspection
Upon delivery, visually inspect the packaging and
portions of the finisher that are visible through the
packaging for shipping damage.
If the package or finisher is damaged or if signs of
possible damage are evident, have the carrier note the
condition on the shipping papers before the shipping
receipt is signed, or advise the carrier of the condition
as soon as it is discovered.
IMPORTANT: Lift the box cover off the finisher
and check the items listed on the packing list.
Advise the carrier of any damaged or missing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles are damaged or
missing.
IMPORTANT: Warranty is void unless the finisher
is installed according to instructions in this manual.
Installation should comply with minimum
specifications and requirements detailed in this
manual and applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
arranged accordingly.
It is strongly recommended that the purchaser be
present during installation and the first tests.
The finisher must be installed in accordance with local
and national regulations and in a well ventilated room.
Refer to following sections for proper installation
procedures.
To prevent fire, explosion, or personal
injury, this finisher may only be installed,
adjusted, and started up by a team of
qualified technicians.
W543
WARNING

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
11
1300003 (EN)
Overall Dimensions and Connecting Data
FWF135N
Figure 2
FWF135N
SPEED
SET +
_
Model
UD13F063
86 in.
(2192 mm)
Gas Inlet and
Electric Inlet
2.76 in.
(70 mm)
5.12 in.
(130 mm)
43.8 in.
(1112 mm)
32 in.
(813 mm)
32 in.
(813 mm)
3.94 in.
(100 mm)
2.36 in.
(60 mm)
2.28 in.
(58 mm) 21.34 in.
(542 mm)
Models UD13F063,
UD13F078, and
UD13F079
26 in. (660 mm)
Models
UD13F078
and UD13F079
100.1 in.
(2542 mm)
REAR VIEW
TOP VIEW
FRONT VIEW Exhaust Duct
4in.
(102 mm)
Model
UD13F126
154 in.
(3910 mm)
Model UD13F126
34 in. (860 mm)
Exhaust Duct
4in.
(102 mm)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
1300003 (EN)
12
Required Materials
IMPORTANT: Keep finisher area clear and free
from combustible materials, gasoline, and other
flammable vapors and liquids.
Location Requirements
IMPORTANT: Transport finisher on skid until
near area of desired installation. Reasonable care
should be taken during installation.
Finisher is shipped with manual crank located on tray.
Be certain to keep manual crank near machine for easy
access.
NOTE: With its trays removed, the finisher will fit
through a 32 inch (813 mm) wide door.
.
To assure compliance, consult and adhere to building
code requirements and comply with the following:
•The finisher must be installed in a very well
ventilated room (especially when using gas
heating) with correct lighting and an ambient
temperature in the range from 32°F (0oC) to
+104°F(40
oC).
•Leveling should be carried out correctly on a
hard and stable floor surface, capable of
supporting the weight of the finisher. The floor
must at least be able to support 150 lbs./ft2
(732 kg/m2) for the installation of the finisher.
•The finisher MUST NOT be installed or stored in
an area where it will be exposed to water and/or
weather.
IMPORTANT: DO NOT block the airflow at the
rear of the finisher with laundry or other articles.
Doing so would prevent adequate air supply to the
combustion chamber of the finisher.
Sufficient space must be left around the finisher to
allow for its correct functioning.
•Allow at least 4 inches (102 mm) in the back to
allow for ventilation.
•Allow 32 inches (813 mm) on each side for
upkeep and maintenance.
•Allow sufficient space in front so that the
operator can work efficiently and safely.
Lifting the Finisher
The finisher should be moved with a forklift as close
as possible to the area where it will be installed. Use a
forklift of sufficient capacity to lift the packaged unit
according to the following procedures.
IMPORTANT: DO NOT lift finisher with slings.
1. Position the forklift arms beneath the center of
the unit (NOT toward either end) to lift the
finisher at its center of gravity.
IMPORTANT: Lifting the finisher from either side
could cause misalignment and/or damage to the
finisher.
2. Adjust the forklift arms to their maximum length
and width and insert them all the way under the
center of the skid. Refer to Figure 3.
Model Weight
UD13F063 1320 lbs. (599 kg)
UD13F078 and UD13F079 1474 lbs. (669 kg)
UD13F126 2094 lbs. (950 kg)
All Models
One fused disconnect switch or branch
circuit breaker (obtain locally)
Pry bar
Three 3.5 inch (89 mm) to
4 inch (102 mm) rollers or pipes
Gas Models One gas shut-off valve for gas service line
to each finisher (obtain locally)
To prevent fire, explosion, or personal
injury, this finisher may only be installed,
adjusted, and started up by a team of
qualified technicians.
W543
WARNING
This machine must be installed in compliance with all local regulations and used
only in a room with adequate ventilation air. Important, read manuals before
installing, operating, servicing or cleaning machine.
Min clearance from both combustible and noncombustible
Construction; 4" from back, 20" from side.
Cet appareil doit être installé conformemént aux réglementations en vigueur et
utilisé seulement dans un endroit bien aéré.
Lire les notices avant d'installer, utiliser, entretenir ou nettoyer la machine.
Espace mini entre machine et matière combustible ou non- combustible:
arrière: 4", côté :20"
FWF141N
FWF141N

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
13
1300003 (EN)
IMPORTANT: The forklift arms must be inserted
all the way under the center of the skid to avoid
toppling the machine.
3. Use the forklift to carefully lift the packaged
finisher. Refer to Figure 4.
IMPORTANT: DO NOT lift the unit more than
8 inches (203 mm) off the ground.
4. Move the packaged unit as close as possible to
the area where the finisher will be installed.
Follow the procedures in Moving the Finisher
with Rollers section.
IMPORTANT: To prevent damage to finisher DO
NOT turn the finisher over or let it drop when
handling.
Moving the Finisher with Rollers
At least three people and three 3.5 inch (89 mm) to
4 inch (102 mm) rollers or pipes are required to move
the finisher from the skid to its final location according
to the following procedures.
IMPORTANT: At least three people are required to
move the finisher. Proper lifting and handling
procedures must be followed to avoid damage to
the finisher.
1. Follow the procedures in Pre-Installation
Inspection section.
2. Remove the protective packing material.
3. Use a pry bar to remove the wood stops from the
skid. Refer to Figure 5.
4. Remove the four shipping bolts from the bottom
of the finisher on the inside of the side panels
where they attach to the skid.
5. Place two rollers on the ground next to the
finisher. Refer to Figure 6.
6. Place the third roller on the ground ahead of the
first two rollers and past the end of the finisher.
FWF10N
Figure 3
FWF14N
Figure 4
FWF14N
8"
8 in.
(203 mm)
FWF13N
Figure 5

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
1300003 (EN)
14
7. Slowly lower the finisher off the skid and onto
the first two rollers, exercising care to keep the
unit level. Refer to Figure 6.
IMPORTANT: DO NOT let go of the finisher at
any point in the moving process.
NOTE: If the distance between the skid and the
rollers is too far to move the finisher safely onto the
rollers, make another “step” by placing blocks of
wood between the skid and the rollers. The wood
should be level and shorter than the skid but taller
than the rollers. Gradually step the finisher down
onto the blocks of wood and then again onto the
rollers.
8. Slowly roll the finisher forward so that it comes
off the first roller, stays on the second roller, and
moves onto the third roller. Refer to Figure 7.
9. Level the finisher from right to left and front to
back. Verify right to left level by checking the
level of the heated roll, not the cabinet.
FWF12N
Figure 6
FWF12N
FWF7N
Figure 7
FWF7N

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
15
1300003 (EN)
Electrical Requirements
IMPORTANT: Electrical connections must be
made by a qualified electrician using data on serial
plate, installation manuals and wiring diagram
provided with machine and according to local
electrical codes. Install a branch circuit breaker as
close to the flatwork finisher as possible. If more
than one flatwork finisher is being installed, a
branch circuit breaker must be provided for each.
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
Grounding Instructions
NOTE: To ensure protection against shock, this
flatwork finisher MUST be electrically grounded in
accordance with the local electrical codes, or in the
absence of local electrical codes, with the latest
edition of the National Electrical Code ANSI/NFPA
No. 70. In Canada the electrical connections are to
be made in accordance with CSA C22.1 latest
edition Canadian Electrical Code, or local
electrical codes. Electrical work should be done by
a qualified electrician.
This flatwork finisher must be grounded. In the event
of malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of least
resistance for electric current. This flatwork finisher
must be connected to a grounded metal, permanent
wiring system; or an equipment grounding conductor
must be run with the circuit conductors and connected
to the appropriate ground location.
WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the
flatwork finisher before servicing.
• Close gas shut-off valve to gas flatwork
finisher before servicing.
• Close steam valve to steam flatwork
finisher before servicing.
• Never start the flatwork finisher with
any guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
flatwork finisher is properly grounded.
W814
To reduce the risk of fire and electric
shock, check with a qualified serviceman
for proper grounding procedures.
Improper connection of the equipment
grounding conductor may result in a risk
of electric shock.
W068
WARNING
In case of servicing (or putting the
flatwork finisher out of order), disconnect
the flatwork finisher from the main supply
by switching off the branch circuit
breaker.
W816R1
WARNING
To reduce the risk of electrical shock,
de-energize the electrical circuit being
connected to the flatwork finisher before
making any electrical connections. All
electrical connections should be made by
a qualified electrician. Never attempt to
connect a live circuit.
W817
CAUTION
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.
W071

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
1300003 (EN)
16
Electrical Connection
For U.S. and Canada only – NOTE: Branch circuit
protection must be provided for the flatwork
finishers and be installed in accordance with the
National Electrical Code NFPA 70 (in Canada, in
accordance with CSA C22.1). Please refer to the
tables below for rating and supply requirements
(wire size).
For CE only – NOTE: Adequate circuit protection
must be provided for the flatwork finishers and be
installed in accordance with regional electrical
codes.
IMPORTANT: Electrical specifications in Ta bl es 1
and 2are subject to change without notice. Always
refer to product serial plate for most current
specifications of product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit
breaker.
Electric Models
Serial Plate Rating Model Wire Size Branch Circuit
Breaker Full Load Amps
208/240/60/3
UD13F063 3 x 6 AWG
(3 x 16 mm2)
60 47
UD13F078 and
UD13F079
3 x 4 AWG
(3 x 25 mm2)
80 58
UD13F126 3 x 1/0 AWG
(3 x 70 mm2)
150 100
230/50/3
UD13F063 4 x 6 AWG
(4 x 16 mm2)
60 42
UD13F078 and
UD13F079
4 x 4 AWG
(4 x 25 mm2)
70 53
UD13F126 1 AWG (42.4 mm2) 125 93
400/50/3
UD13F063 5 x 8 AWG
(5 x 10 mm2)
35 26
UD13F078 and
UD13F079
5 x 8 AWG
(5 x 10 mm2)
45 33
UD13F126 4 AWG (21 mm2)70 53
Table 1
Gas Models
Serial Plate Rating Wire Size Branch Circuit Breaker Full Load Amps
120/60/1 3 x 14 AWG (3 x 2.5 mm2)15 7.5
230/50/3 3 x 14 AWG (3 x 2.5 mm2)15 4.8
400/50/3 5 x 14 AWG (5 x 2.5 mm2)15 4.7
Table 2

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
17
1300003 (EN)
Gas Connection
IMPORTANT: The installation must comply with
local codes or, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1 in
the U.S.A., or the current CAN/CSA B149,
Installation Codes in Canada.
Install a shut-off valve to isolate gas connections from
rest of installation. Gas models must be connected to
the existing gas pipes. The gas supply pipe size must
have sufficient dimensions to minimize pressure loss.
Obtain specific gas supply pipe size from the gas
supplier. Refer to Tab le 3 for general pipe size.
When connecting to a gas line, an equipment shut-off
valve must be installed within 6 feet (1.8 m) of the
finisher. A 1/8 inch NPT pipe plug must be installed as
shown. Refer to Figure 8.
IMPORTANT: Be certain finisher is configured for
type of gas being used. Refer to Gas Conversion
section for additional information.
Gas Pipe Size Required for 1000 Btu Natural Gas — 0.64 Specific Gravity
at 7 ± 1.5 inches (17.4 ± 4 mbar, 1.74 ± 0.37 kPa) Water Column Pressure
Equivalent Length
Gas
Appliances
Total Btu/hr.
25 feet
(7.63 m)
50 feet
(15.25 m)
75 feet
(22.88 m)
100 feet
(30.50 m)
125 feet
(38.13 m)
150 feet
(45.75 m)
Based on 0.3 in. Water Column Pressure Drop for Length Given
Sizes shown in inches (mm)
100,000
120,000
140,000
160,000
180,000
200,000
300,000
400,000
500,000
600,000
700,000
800,000
900,000
1,000,000
0.75 (19.05)
0.75 (19.05)
0.75 (19.05)
0.75 (19.05)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
0.75 (19.05)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
Table 3

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
1300003 (EN)
18
Gas Technical Specifications for CE
Models
Inlet Pressure
Use a manometer to verify that the inlet pressure meets
the following requirements:
Natural Gas service must be supplied at
7.0 ± 1.5 inch water column pressure
(1.74 ± 0.37 kPa).
L.P. (Liquefied Petroleum) Gas service must be
supplied at 11 ± 0.3 inch water column pressure
(2.74 ± 0.07 kPa).
Manifold Pressure
To check manifold pressure, use a manometer to verify
that the settings of the gas valve correspond with the
type of gas being used.
1. Connect the manometer to the pressure
connection located on top of the gas valve while
the burner is ignited.
2. Read the manometer to determine the pressure of
the gas. The measured gas pressure must be equal
to the pressure indicated on the finisher’s serial
plate.
3. Install a pressure regulator valve (obtain locally),
suited for the nature and flow rate of the gas
used, in the tube system near the finisher.
Country Gas
Category
Gas
Designation
Pressure
(mbar)
DE
I2ELL G20 20
G25 20
I3P G31 50
AT/DK/FI/IT/
SE
I2H G20 20
IE/PT/GB/GR II2H3P G20 20
G31 37
CH/ES II2H3P G20 20
G31 37 and 50
BE
I2E+ G20 20
G25 25
I3P G31 37
FR
II2Esi3P G20 20
G25 25
G31 37 and 50
LU II2E3P G20 20
G31 50
NL II2L3P G25 25
G31 50
Table 4
D233i
1New Stainless Steel Flexible Connector –
Use only if allowed by local codes (Use
Design A.G.A. Certified Connector)
21/8 in. NPT Pipe Plug
(For checking inlet gas pressure)
3Equipment Shut-Off Valve – Installed within
6 ft. (1.8 m) of finisher
4Black Iron Pipe
51 inch Gas Connection
Figure 8
3
1
4
2
5
This manual suits for next models
3
Table of contents
Other Alliance Laundry Systems Finisher manuals