AT-CV5M01 |Converteon™ Series Management Card
Technical Specifications
Status Indicators
LED State Description
PWR Green The CPM card is receiving power
OFF The CPM card is not receiving power
RDY Green The CPM card has passed diagnostics
and is ready
OFF The CPM card has failed diagnostics
and is not ready
FLT Red The CPM card has experienced fault
condition
OFF The CPM card has reported no fault
condition
LK Green Link established on the card Ethernet
port
OFF No link established on the card
Ethernet port
AT Flashing TX/RX activity established on the
card Ethernet port
OFF No activity established on the card
Ethernet port
FD Green The CPM card is operating in
full-duplex mode
OFF The CPM card is operating in
half-duplex mode
Connectors
RS232 Female DB-9
Baud Speed 1200 ~ 115200bps
Ethernet 10/100TX, Auto MDI/MD-IX
Management Features
Management Interfaces
RS232 (Local Login): Username and Password
protected (Enable/Disable Local
Login)
Telnet (Remote Login): Username and Password
protected (Enable/Disable Remote
Login)
SNMP Managers: Named SNMP Manager
(Enable/Disable SNMP)
(Up to 4 SNMP manager)
DHCP
DHCP Client (Enable/Disable)
System Warnings
Over Temperature warning
PSU failure warning
Fan failure warnings
Blade failure
Insert/Remove Power Supply
Insert/Remove Fan module
Insert/Remove blade
Operational Warnings
Link Up/Down
Event Logging
Time and Date stamp for all log entries
Internal Log
Syslog
Administration
Diagnostics
Firmware Upgrade (Mangement card)
Firmware Upgrade (Blade firmware)
Configure MissingLinkTM
Configure Smart MissingLinkTM
Configure Link Monitor
Configure IEEE 802.3ah OAM
Physical Specifications
Dimensions 2.2cm x 7.3cm x 13cm
(H x W x L) (.855” x 2.89” x 5.10”)
Weight: 0.60 lbs
0.27 kg
Package Contents
One AT-CV5M01 CPM Card
One DB-9 RS-232 Serial Cable
Installation Guide
Warranty Card
Power Characteristics
Input Supply Voltage 5vDC, 3.3vDC
Maximum Input Current 1.15 A(5vDC), 0.86 A (3.3vDC)
Power Consumption 9.6 watts maximum
Environmental Specifications
Operating Temperature 0°C to 40°C
(32°F to 104°F)
Storage Temperature -25°C to 70°C
(-13°Fto 158°F)
Operating Relative Humidity5% to 90% RH
(non-condensing)
Storage Relative Humidity 5% to 95% RH
(non-condensing)
Operating Altitude Range Up to 3,048m (10,000ft)
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
Quality and Reliability:
MTBF> 100,000 hrs
Electrical Interfaces:
UL60950 (UL/cULus)
EN60950 (TUV)
CSA22.2 No. 950
Ordering Information
AT-CV5M01
SNMP Management Module
Associated Products
AT-CV1000-xx
Single slot Converteon™ chassis
AT-CV1203-xx
Two slot Converteon™ chassis
AT-CV5000-xx
18 slot, Converteon™ chassis