Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
Ordering Information
AT-CV1KSS
Gigabit Ethernet Converteon media converter line card
1000X SFP to 1000X SFP
Associated Products
AT-SPSX
1000SX (SC), 220m multi-mode Fiber Gigabit module
AT-SPLX10
1000SX (SC), 10m single-mode Fiber Gigabit module
AT-SPTX
1000T, 100m copper Gigabit module
AT-CV1000-xx
Single slot Converteon chassis
AT
-CV1203-xx
Two slot Converteon chassis
AT-CV5000-xx
18 slot, Converteon chassis
AT-CV1KSS |Converteon Series Line Card
USA Headquarters |19800 North Creek Parkway |Suite 200 |Bothell |WA 98011 |USA |T: +1 800 424 4284 |F: +1 425 481 3895
European Headquarters |Via Motta 24 |6830 Chiasso |Switzerland |T: +41 91 69769.00 |F: +41 91 69769.11
Asia-Pacific Headquarters |11 T
ai Seng Link |Singapore |534182 |T: +65 6383 3832 |F: +65 6383 3830
www.alliedtelesis.com
©2007 Allied T
elesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners. 617-000142 RevE
Link Test, MissingLink and Smart
MissingLink Functions
Link Test
The link test is a fast and easy way for you to test the
connections between the media converter ports and the
end-nodes that are connected to the ports. If a network
problem occurs, you can perform a link test to
determine which port is experiencing a problem, and so
be able to focus your troubleshooting efforts on the
cable or end-node where the problem resides.
MissingLink
The MissingLink feature enables the two ports on the
media converter to pass the ‘Link’ status of their
connections to each other. When the media converter
detects a loss of connection to an end-node, the media
converter shuts down the connection to the other port,
thus notifying the end-node that the connection has
been lost.
Smart MissingLink
The Smart MissingLink feature performs exactly the same
function as MissingLink with one additional feature.
When a link is lost on a port, the LINK LED of the
port which still has a valid connection to its end-node
starts to blink. This allows you to quickly determine
which portstill has a valid connection
(LINK LED blinking) and which porthas lost its
connection (LINK LED off).
Technical Specifications
Status Indicators
Status LEDs
System LEDs
LED Color Description
RDY Green The line card has passed
diagnostics
Off The line card has not
passed diagnostics
ML Green MissingLink mode is
enabled
Off MissingLink mode is
disabled
SML Green Smart MissingLink mode
is enabled
Off Smart MissingLink mode
is disabled
SFP Port LEDs (per port)
LED Color Description
LK Green Link established on the port
Flashing When SmartMissingLink
is enabled, if a link has
failed, this shows the port
that still is correctly
connected
Off No link established on the
port
AT Green TX/RX activity detected on
the port
Off No activity detected on
the port
DIP Switches
The AT-CV1KSS line card features only the Diagnostic
Mode DIP switches.
The table below lists the positions of the DIP switches.
‘x’ means the DIP switch position could be either ON or OFF.
Physical Specifications
Dimensions: 2.2cm x 7.3cm x 13cm
(W x D x H) (.855" x 2.89" x 5.1")
Weight: 0.27 kg (0.60 lbs)
Optical Characteristics
Dependent on the SFPs used. See datasheets for specific
SFPs.
Packet Size
Maximum packet size = Infininate - no frame buffer
Power Characteristics
Power consumption 4.75W
Environmental Specifications
Maximum operating temperature: 0°Cto 40°C
(32°F to 104°F)
Maximum storage temperature: -25°C to 70°C
(-13°F to 158°F)
Operating and storage altitude: Up to 3,048 meters
(10,000 feet)
Relative humidity operating 5% to 95%
and storage: (non-condensing)
Predicted MTBF (Telcordia SR332): 1,370,000 hrs
Operating Mode DIP 1 DIP 2 DIP 3
Smart MissingLink (SML) OFF ON X
MissingLink (ML) ON OFF X
Link Test (default) OFF OFF X
Manufacturing Default Settings OFF OFF OFF