Datasheet | Remote Multiservice Terminal
Product Overview
The RMT30 (Remote Multiservice Terminal) is a
sealed, climate controlled cabinet that protects
Allied Telesis access equipment from water, dust
and all other outdoor elements. The RMT30 is
one of a choice of nine sizes of cabinets and lets
service providers select an exact match for their
needs, with the assurance that Allied Telesis
integrates the Multiservice Access Platform and
associated equipment before shipment.
Capacity
The RMT30 cabinet can accommodate up to
four MiniMAP 9100s, two iMAP 9400s, or one
iMAP 9700. Initial capacity needs can be met
and the design allows for future growth. Allied
Telesis will work with service providers to find
an ideal cabinet size with port counts ranging
from small to large sized applications for POTS,
DSL or FTTx deployments.The Allied Telesis
equipment will then be integrated into the
cabinet and shipped.
Turnkey System
The RMT30 cabinets include Allied Telesis
integrated Multiservice Access Platforms
(iMAPs), AC Load centers, and DC power
plants. POTS splitters, cable management and
other accessories are also installed in the
cabinet and tested before shipment.This
reduces on-site staging and the chance for
installation errors.
Connectivity
The RMT30 supports POTS, ADSL/ADSL2+,
VDSL2 and fiber, as well as mixed POTS,
ADSL/ADSL2+,VDSL2 and fiber deployments.
The RMT30 is unique in its use of high
performance CAT5 cabling for ADSL2+ and
VDSL2 applications.This reduces noise and
crosstalk to improveoverall performance, paving
the wayto higher reliability and more service
choices. Service providers can
expect to see improved rate vs. reach as a
result of the optimized cabling schemes.
Flexibility
The RMT30 uses an expandable power
supply system that supports entry-level needs
and easily grows to support additional demand.
Battery back-up, battery heaters, pad/pole
mounting kits, integrated cross connects and
copper protection is optional.
Reliability
The RMT30 meets
Telcordia GR-487
standards. Battery compartments are sized
to accommodate up to a 150 amp hour battery
strings providing for eight hour battery back-up.
The enclosures require little, if any, maintenance
for fans and filters.
Key Features
•Integrated environmentally controlled cabinet for
Outside Plant (OSP) deployments
•Integrated power supplies and Allied Telesis
integrated Multiservice Access Platforms
•Arange of OSP cabinet sizes and configurations
sized to meet deployment needs
•Supports POTS, ADSL2+,VDSL2, legacy
telephony and fiber FTTx deployments
•Sealed design with efficient, low maintenance
environmentally controlled cooling
•Meets Telcordia GR-487 requirements
•Optional batteries, battery heater, generator
connector, integrated cross connect and other
cabinet accessories
•Optional CAT5 wiring between all cabinet
components
RMT30
Remote Multiservice Terminal
Allied T
elesis www.alliedtelesis.com
Technical Specifications
Physical Characteristics
Dimensions 110.7 x 186.5 x 71.6cm (w/o SAI)
(W x H x D) 43.59 x 73.42 x 28.2in
140.8 x 186.5 x 71.6cm (with SAI)
55.45 x 73.42 x 28.2in
Weight 145kg (320lbs)
Enclosure Mounting
Pad or pole
Mounting Space
52in (29RU)
Hole Spacing on Racks
One inch
Rack Widths
23in EIA std
Center Mounting
Standard 12in deep
Heat Exchanger
One
Temperature
Fan turns on 37°C (100°F)
High temp. alarm 65°C (150°F)
Heat dissipation 1200W
AC System
Eight position AC load center
Convenience Outlets
One in equipment chamber
Battery Heater Pad
Optional
Compatible Batteries
4 x 48vDC
Battery Amp-hour Reserve
150 AMP hours
Padlockable
216-type tool
Intrusion Alarm
Local with remote location options
Bonding and Grounding
210-position dual-holed
L49 copper buss, 3/16in
Cable Entrance
3x2.5in cable cones
Protect Field
Up to 600-pair
Cross Connect Field
Up to 1200-pair
Ordering Information
AT-TN-R015-A Cable, alarm, 10ft
AT-TN-R016-A Fiber tray
AT-TN-R018-A RMT20/30 mounting template with
SAI pad
AT-TN-R020-A RMT20/30 battery heater pad
AT-TN-R022-A Hubbel con for external generator, 30A
AT-TN-R023-A RLS block, 50-pair, CAT3, 3M MS2 conns
AT-TN-R024-A Battery (1) 12vDC, 155AH, front post
AT-TN-R027-A Bullet breaker, 30A
AT-TN-R028-A Protection block, 200PR, CAT5,
3M MS2 conns
AT-TN-R030-A Valere power bundle
AT-TN-R031-A 25A rectifier
AT-TN-R032-A Rectifier controller, LAN capable
AT-TN-R034-A 200-pair copper protection - wired with
CAT3cabling and connectorized with
3M MS2 connectors
AT-TN-R035-A 50-pair RLS block wired with
CAT 5 cabling and connectorized with
3M MS2 connectors
AT-TN-R037-A Pad mount template for RMT20/RMT30
without SAI
AT-TN-R038-A Pole mount kit for RMT20/RMT30,
with SAI
AT-TN-R039-A Pole mount kit for RMT20/RMT30,
without SAI
AT-TN-R041-A RMT-30 without SAI enclosure
AT-TN-R042-A RMT-30 with SAI enclosure
AT-TN-R051-A 20A rectifier
AT-TN-R053-A 10A rectifier
RMT30 |Remote Multiservice Terminal
USA Headquarters |19800 North Creek Parkway |Suite 100 |Bothell |WA 98011 |USA |T: +1 800 424 4284 |F: +1 425 481 3895
European Headquarters |Via Motta 24 |6830 Chiasso |Switzerland |T: +41 91 69769.00 |F: +41 91 69769.11
Asia-Pacific Headquarters |11 T
ai Seng Link |Singapore |534182 |T: +65 6383 3832 |F: +65 6383 3830
www.alliedtelesis.com
©2008 Allied T
elesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners. 617-000278 Rev.A

Other Allied Telesis Touch Terminal manuals

Allied Telesis RMT20 User manual

Allied Telesis

Allied Telesis RMT20 User manual

Allied Telesis RMT60 User manual

Allied Telesis

Allied Telesis RMT60 User manual

Popular Touch Terminal manuals by other brands

Star AsuraCPRNT Configuration manual

Star

Star AsuraCPRNT Configuration manual

ECKELMANN AL 300 W Operating	 instruction

ECKELMANN

ECKELMANN AL 300 W Operating instruction

DIEBOLD NIXDORF DN Series installation guide

DIEBOLD NIXDORF

DIEBOLD NIXDORF DN Series installation guide

Beijer Electronics X2 base 15 v2 HP Hardware and installation manual

Beijer Electronics

Beijer Electronics X2 base 15 v2 HP Hardware and installation manual

Unitech HT730 quick start guide

Unitech

Unitech HT730 quick start guide

Rockwell Automation Allen-Bradley PanelView Plus Series user manual

Rockwell Automation

Rockwell Automation Allen-Bradley PanelView Plus Series user manual

Speco N8NRT quick start guide

Speco

Speco N8NRT quick start guide

M-system DL8 Series user manual

M-system

M-system DL8 Series user manual

Festo MPA1-MP Series manual

Festo

Festo MPA1-MP Series manual

Nokia Cardphone 2.0 user guide

Nokia

Nokia Cardphone 2.0 user guide

Intermec Trakker Antares 2480 install guide

Intermec

Intermec Trakker Antares 2480 install guide

Mitsubishi Electric GOT 1000 Series Connection manual

Mitsubishi Electric

Mitsubishi Electric GOT 1000 Series Connection manual

suprema X-station user guide

suprema

suprema X-station user guide

First Data FD100 Quick setup guide

First Data

First Data FD100 Quick setup guide

Datalogic Joya quick start guide

Datalogic

Datalogic Joya quick start guide

Beckhoff KL6581 Documentation

Beckhoff

Beckhoff KL6581 Documentation

Beam RST100 User and installation manual

Beam

Beam RST100 User and installation manual

Hypercom M4230 manual

Hypercom

Hypercom M4230 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.