1、Introduction
Compact, rugged and easy to use. Just aim and push the button, read
current surface temperatures in less than a second. Safely measure
surface temperatures of hot, hazardous or hard-to-reach objects without
contact.
How it works
Infrared thermometer measures the surface temperature of an object. The
unit’s optics sense emitted, reflected, and transmitted energy which is
collect and focused onto a detector. The unit’s electronics transmitted
energy which is display on the unit. For increased ease and accuracy the
laser pointer makes aiming even more precise.
Cautions
Infrared thermometer should be protected for the following:
--EMF(electro-magnetic fields) from arc welders, induction heaters.
--Thermal shock(cause by large or abrupt ambient temperature changes
allow 1 hours for unit to stabilize before use).
--Do not leave the unit on or near objects of high temperature.
Warning
Do not point laser at eye or indirectly off reflective surfaces.
1. When take measurement, point thermometer toward the object to be
measured and hold the yellow trigger. The object under test should
be large than the spot size calculated by the field of view diagram.
2. Distance &spot size: As the distance from the object increase, the
spot size of measuring area becomes large.
3. Field of view: Make sure the target is larger than the unit’s spot size.
The smaller the target the close measure distance. When accuracy is
critical, make sure the target is at least twice as large as the spot
size.
4. Emissivity: Most organic materials and painted or oxidized surfaces
have an emissivity of 0.95. Inaccurate readings will result from
measuring shiny or polished metal surfaces. To compensate, cover
the surface to be measured with masking tape or flat black paint.
Measure the tape or painted surface when the tape or painted reach
the same temperature as the material underneath.
5. When changing from low temperature environment to high
temperature environment or from high temperature
environment to low temperature environment, please wait for
30 minutes, and then measure after the temperature of the
machine is balanced with the ambient temperature.
2、Quick start instruction
1. Remove the battery cover screw with a screwdriver, and then slide
out the battery door, install battery correctly. And Put back to the
battery door screws .Pull the trigger, LCD display reading &
battery icon. Release the trigger and the reading will hold for 10
seconds.
LCD display:
Display area:36.4×34.6(mm),character 13.3mm high.
A Data Hold
B Main dislplay value
C Memory storage
D Maximum
E Continuous measurement
F K type temperature symbol (this unit Without this feature)
GHigh temperature alarm temperature
H Alarm of high temperature prompt
I Alarm of Low temperature prompt
J Low temperature alarm temperature
K Battery voltage Low
L Backlight symbol
M Additional features
NMinimum
OAverage
P The maximum and the minimum difference
Q Temperature of the unit
R Laser pointer turn on prompt
S Emissivity symbol
T Measuring the symbol
2. Locating a hot spot aim the thermometer outside the area of interest,
then scan across with up and down motions until you locate the hot
spot.(please turn on the laser to for accurate measuring)

2
3. Diagram description
(1) Trigger :Press for turn on, and then display test result and hold
data automatically(display HOLD) after unclamping switch. Trun
off automatically after 10 seconds without operate.
(2) Laser pointer button :press it display “ ” for turn on laser pointer,
press again for turn off.
(3) Back light/UP button :When product working, press it for turn on
back light, press again for turn off. the second functian please see
(4)
(4) MODE button:Press MODE button for cycle options MAX –
MIN-DIF- AVG - HAL– LAL mode.
A、MAX:Measure maximum data current;
B、MIN:Measure minimum data current;;
C、AVG:Calculate the average of all measure data;
D、DIF:The maximum and the minimum difference;
E、HAL/LAL:HAL is Alarm of high temperature. LAL is Alarm of
low temperature. Option Alarm of temperature mode, press“Back
light/UP”button for up alarm temperature. press“T/DN”button for
down alarm temperature. When LCD display ” HI” means
measure result exceeded the alarm temperature ;When LCD
display ” LOW ” means measure result under the alarm
temperature
(5) T/DN button:When product working, press direct for ℃ / 0F select.
second functian please see (4).
(6) E/ button :When product working, press direct into set
Emissivity mode, press“Back light/UP”button for up Emissivity .
press“T/DN”button for down Emissivity. Long press the button, the
head lamp lighted.
(7) LCD
(8) Battery door: When replace battery ,take off the scrrew ,then slide
open the battery door.
The diagram below operation:
1. Use the screwdriver to unscrew the bottom screw;
2. Catch the hook and take the cover of battery out from the
bottom;
3、Maintenance
1) Lens cleaning: Blow off lose particles using clean compressed air.
Gently brush remaining debris away with a moist cotton cloth.
2) Case cleaning: Clean the case with a damp sponge/cloth and mild
soap.
3) Please take out the battery when not using for a long time.
Note:
1) Do not use solvent to clean lens.
2) Do not submerge the unit in water.
3) Emissivity will back to the initial value (0.95) after replacing
battery,. Should adjust again when use.
4、Specifications
Attached list :Applicable Emissivity for Different Material
( For reference only )
Material Emissivity Material Emissivity
Asphaltum 0.90 to 0.98 Textile(Black)0.98
Beton 0.94 Human Skin 0.98
Cement 0.96 Soap bubble 0.75 to 0.80
Sand 0.90 Charcoal(powder)0.96
Soil 0.92 to 0.96 Lacquer 0.80-0.95
Water 0.92 to 0.96 Lacquer (reluster)0.97
Ice 0.96 to 0.98 Rubber(Black)0.94
Snow 0.83 Plastic 0.85-0.95
Glass 0.90 to 0.95 Timber 0.90
Ceramic 0.90 to 0.94 Paper 0.70-0.94
Marble 0.94 Chromic oxide 0.81
Gypsum 0.80 to 0.90 Copper Oxide 0.78
Compo 0.89 to 0.91 Iron Oxide 0.78 to 0.82
Brick 0.93 to 0.96 Stainless steel 0.2-0.3
Above picture and content just for your reference. Please be subject
to the actual products if anything different or updated. Please
pardon for not informing in advance.
CONTACT US
For any problem or concern, welcome to email us for prompt
response.
P.S.
To make sure you can receive immediate solution and your
requests processed quickly, please email us with information
below:
1. Order Number
2. Platform of Your Purchase
3. Full Model Number
4. Description of the Problem
(Attaching videos or photos can help us troubleshoot the
problems even faster)
Temperature range
-50℃ to 1500℃(-58 to 27320F)
Accuracy
±4℃/7.20F, -50℃ to 0℃(-58 to 320F)
±(2% reading +2℃/3.60F), 0℃ above
distance spot ratio
30:1
Emissivity
0.1~1.0 adjustable
Resolution
0.1℃(0.10F)<1000, 1℃(10F)>1000
Repeatability
1% of reading or 1℃
Response time
<250msec, 95%response
Spectral response
8-14um
Operating temperature
0℃ to ~40℃(32 to 1040F)
Storage temperature
-20~60℃(-4~1400F) without battery
Relative humidity
Operating :10-95%RH; Storage: 10-95%RH
Ambient temp range of
guarantee for accuracy
23℃~28℃
Weight/dimensions
160g; 192×95×63mm
Power
9V battery, 6F22 or NEDA 1604
Battery life
Laser models:12hrs

AILink User Manual
Summary
AiLink is a comprehensive intelligent hardware management
platform. Through AiLink App, you can complete the convenient
between mobile phones and intelligent hardware,achieve the
interconnection and intercommunication between devices and
users. AILink supports multiple types of devices, such as smart
health.
APP download and installation
Scan the below QR code to download directly, or search for
"AILink" in the APP Store, Google Play download and install the
"AILink".
Account registration
1Set up an account: select the method of registration: mobile
phone or email, enter the content, this account is used for
login;
2Verify the account: Click the "Send" button to send a
verification code to the registered account to verify the
account. The verification code will send in 120s. Please click
send again if the verification code is over time;
3Set the password: In order to ensure the security of the
account, the password must be composed of 6-16 digits +
grapheme;
4All settings are completed, click “Register” to complete the
registration;
Login
1Account + password login: Set up an account and
password through registration, and log in with the
set account + password;
2Third-party application authorized login: currently
supports WeChat and facebook authorized login.
Forgot Password
When the user forgets the password, he can reset the password
through this setting
1Enter the account that needs to reset the password;
2Send verification code: Click the "Send" button to send the
verification code to the entered account, verify the account,
the sending time of the verification code is 120s, if you didn’t
received that in time, please click send again;
3Reset password: the setting method is the same as that
account registration;
4All settings are completed, click "Submit Reset" to complete,
you can use the new password to log in to the APP;
Supplement master account information
Due to the diversity of supported devices, it is necessary to set
an profile image, nickname, birthday, and gender when creating
a user. The supplementary information is used for data
calculation of some devices and analysis of measurement data
Bonding/connecting devices
There are two ways to connect devices: nearby devices,
manually add
1Nearby devices: Open the device page to automatically
search for nearby matching devices, and click the searched

device to automatically connect;
2Manually connect: select the device that needs to be added
and operate according to the operating instructions to add;
1) Click "start to use" to enter the function page.
2)Function introduction
1. Wake up function button: infrared thermometer app is
connected to the mobile phone. When infrared thermometer
app is automatically closed or the mobile phone program is
closed, you can wake up the infrared thermometer through
this button.(When the infrared thermometer and the mobile
phone are not in the same place, the infrared thermometer
can be turned on by remote control, and the distance in the
open place can reach 80m)
2. Measurement button: press the button,the infrared
thermometer can carry out for continuous measurement.
3. Stop button: press the button to stop the continuous
measurement. And stop recording data.
4. Reset button: press the button to reset the temperature
value of the main interface.
5, 6, 7, 8, 9, 10, 11, 12 and 13 are the keys corresponding to
the infrared thermometer. You can use the keys on the mobile
app to operate and control the infrared thermometer.
3)Click the "data" button to view the historical recording time and
historical recording data, and press the button in the upper right
corner to share or download the data.

4)Click the settings button to view the software version, set the
sampling rate or auto shutdown time.
※After using this product, if it is no longer used for a long
time, it is recommended to remove the battery, otherwise
the battery will be consumed all the time.
Feedback
With any comments or suggestions, you can tell us through this
function to help us improve the product and make the product
better. After receiving the feedback, we will handle it as soon as
possible. The problem should be described in detailed as much
as possible, and the corresponding picture can be added to the
APP problem. In order to supplement the description more
clearly, the programmer can reproduce the problem and solve
the problem faster.

CONTACT US
For any problem or concern, welcome to email us
for prompt response.
AFTERSALES1010@HOTMAIL.COM
P.S.
To make sure you can receive immediate solution
and your requests processed quickly, please email
us with these information:
1.Order Number
2.Platform of Your Purchase
3.Full Model Number
4.Description of the Problem(Attaching videos or
photos can help us troubleshoot the problems
even faster)

FCC Caution:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable
exposure condition without restriction.
FCC ID: 2A7T4-HP-1500-APP
Table of contents