8. GENERAL OPERATION
EAR, EYE & RESPIRATION PPE IS REQUIRED BEFORE USING THIS BOOTH. MAKE SURE ALL BROKEN SKIN IS PROTECTED FROM
DUST AND AIRFLOW!
Only use this Booth when the pressure gauge reads in the green
area. If the Booth is working outside of the green zone, then there
may be a damaged item on the assembly. In this case stop using
the Booth immediately, isolate the supply & check all ducting &
collection parts thoroughly.
The Booth will automatically switch o if the gauge pressure
reads above 0.7kPa. In this case the main canister lter on the
extractor must be replaced before the Booth is operational again.
Contact your local JetBlack Safety representative, quoting the
part reference (found in the extractor manual) for a replacement.
Always isolate the electrical supply & wear correct PPE when
maintaining the Booth or extractor.
Switch on the power supply to the Booth control panel.
Turn on the main isolator at the rear of the Booth. Prior to
using the Cleaning Booth for removing dust from worker’s
clothing, the user must make sure they are wearing the correct Personal Protective Equipment (PPE) which normally includes:
• Dust mask or respirator
• Ear protection
• Eye protection - preferably goggles
Step-by-step Operation:
• Open the door, step into the Booth and close the door fully. The interior light and the extractor will turn on automatically.
The Cleaning Station can now be used.
• Press the touch pad to operate the Cleaning Booth. This is pre-set for a 30 second operation. If a longer clean down time is
required re-press the touch pad to re-start. If something should go wrong, during the course of a cleaning cycle, or you
simply want to stop the cleaning process, you have the option of stopping the Cleaning Station by pressing the touch
button at any time.
• During the cleaning cycle, the user should ensure all of their body is exposed to the airow from the Cleaning Station.
In most cases 20-30 seconds is a sucient cleaning cycle.
• Do not worry about getting to close to the airow of the Cleaning Station – it is perfectly safe and will not cause any
harm. In fact, the closer the airow to clothing and skin, the better the cleaning process.
• When you are suciently clean, turn o the Cleaning Booth and exit the Booth. The extractor will continue to run for a
time, and a lter agitator process will begin. This is standard operation and it ensures that any debris from the lter is
removed.
Please note
The Cleaning Station tted has a thermal shut-o device for safety purposes. Prolonged use may cause the unit to shut o. In
this case, switch the unit o and wait for a few minutes before re-using.
Spares lters for the Cleaning Station and the extractor can be purchased through Almeco. Replacement lters information is
as follows:
• JetBlack inlet lter – B3.003.054
• Extractor HEPA Filter – B3.004.285