Dear Customer,
we are glad because of your interest in our products.
Thank you for the confidence you have shown us.
Please attend technical safety instructions on this page, before startup
of your new cleaning machine for circuit boards Öko 2000.
Now we wish you success at cleaning of your products.
If you have questions, you can get in contact with us anytime.
IMO GmbH
IMO GmbH Gässlesweg 6 D-75334 Strauben ardt Tel.: 070 82 491 80 Fax: 604 36 www.imo-ag.com info@imo-ag.com
4
GmbH
1. Safety Instructions
The washing machine ÖKO 2000 must only be connected to a supply protected
by a fuse rated not more than 16A! Please see for the power supply voltage
at the type label on the machine.
The installation of the machine should be arranged from employees, who are familiar
with installation of such or similar machines. Our technicians will like to help you.
Please only use cleanser, which you have bought at our company.
Our cleansers are coordinated especially at the cleaning requirements of that
cleaning machine for circuit boards. If you anyway should want to use an other cleanser,
please obtain an O.K. from our technicians. If you use external cleanser and you didn’t
get O.K. from us, you will loose guarantee for your machine, because such cleanser
can destroy the machine.
Please make sure, if your laundry is suitable for such cleaning processes. We assume no
liability for damages because of process, material and temperature compability on cleaned
circuit boards and components.
You can’t clean glas-tube fuses! Those components please fit after cleaning process.
Please regulary check the boarder of the bottom metal filter for traces of rust. These may
be caused by pieces of iron and may lead to contact corrosion on the stainless steel.
If you do not dry after cleaning process, you have got to start every day after work a separat
drying process. So your can avoid damages of corrosion (rust) at the drying turbine.
The opened door to charge only with max. 25 kg (with extended grate and laundry)
Don’t use as work disk or seating. Don’t stand on it, there is danger of tilting!
To avoid water damage, the cleaning machine can be put into operation only in connection
with the external solenoid valve.