ENG
Contents
1 About these instructions 8
1.1 Validity, storage and forwarding of the instructions 8
1.2 Symbols 8
2 Safety 9
2.1 Intended use 9
2.2 Safety notes 9
3 Function 10
4 Device overview 11
4.1 Technical data 12
5 Commissioning 13
5.1 Teaching the device 13
5.1.1 Teach-in without Alpha IP Access Point (stand-alone operation) 13
5.1.2 Teaching-in to Alpha IP Access Point 14
5.2 Installation 15
5.2.1 On-surface installation 15
5.2.2 Installation in flush-type box 16
5.2.3 Installation with adhesive strips 16
6 Operating modes and configuration 17
6.1 Configuration menu 17
6.1.1 Automatic mode 18
6.1.2 Manual operation 18
6.1.3 Holiday mode 19
6.1.4 Operating lock 19
6.1.5 Programming of heating profiles 19
6.1.6 Setting date and time 21

ENGNORSWE DANFINPOLRUS
7
ENG
6.1.7 Offset temperature 21
6.1.8 Selection of temperature display/humidity 22
6.1.9 Configuration of Alpha IP Base station 22
6.1.10 Connection test 23
7 Operation 23
8 Displays 24
8.1 Status indications 24
8.2 Error indications 25
9 Changing the batteries 26
10 Cleaning 27
11 Restoring the factory settings 27
12 Decommissioning 28
13 Disposal 28

POL RUSFINDAN SWENORENG
8
About these instructions
ENG
1 About these instructions
1.1 Validity, storage and forwarding of the instructions
1.2 Symbols
The following symbols are used in this manual:
Note: Identifies important or useful information
ÖPreconditions
ÖResult from an action
• List without fixed order
1., 2. List with fixed order
These instructions apply to the room control unit Display RTD 61001-N1. These
instructions include information necessary for commissioning and operation. These
instructions must the read completely and thoroughly before commencing any work
with the device. These instructions must be kept and to be handed over to future
users.
The latest version of these instructions/of Additional Alpha IP System infor-
mation can be found under www.alphaip.de.
System information, functions and operating steps from the instructions for
Alpha IP Access Point (HAP 21001) must be observed.

ENGNORSWE DANFINPOLRUS
9
Safety
ENG
2 Safety
2.1 Intended use
2.2 Safety notes
All safety notes in these instructions must be observed in order to avoid accidents
with personal damage or property damage. No liability is assumed for personal and
material damage caused by improper handling or non-observance of the hazard
notes. Such cases render all warranty claims invalid. No liability is assumed for con-
sequential damage!
• Only use the device if it is in flawless state.
• Observe the performance limits of the device and its environmental conditions.
• Only operate this device in a dry and dust-free environment.
The room control unit Display RTD 61001-N1 is a component of the Alpha IP System
and serves for
• the installation in residence-related environments,
• the registration of the actual temperature (room temperature) and the humidity,
• the setting of the target temperature (comfort temperature),
• the control of the actual temperature by an activation of the Alpha IP Base sta-
tion for the control of floor heating systems (FAL-x10x1-xxN1) or connected Al-
pha IP radiator thermostats,
• a wireless communication in the Alpha IP network.
Every other use, modification and conversion is expressively forbidden. Improper use
leads to dangers the manufacturer cannot be held liable for, and to an exclusion of
warranty and liability.

POL RUSFINDAN SWENORENG
10
Function
ENG
• Do not expose the device to humidity, vibration, continuous sunlight or other
types of heat radiation, coldness, or mechanical loads.Ensure that children do
not play with this device or the packaging. Children must be monitored if nec-
essary.
3 Function
The Alpha IP room control unit Display RTD 61001-N1 allows to set the room tem-
perature in a time-controlled way in order to adapt the heating phases to your indi-
vidual requirements. The room control unit measures the temperature and transmits
these data cyclically to the Alpha IP Base station FAL-x10x1-xxN1 or to connected
Alpha IP radiator thermostats. The registered values allow an exact regulation of
the room temperature. The target temperature can be set manually with the setting
wheel.
Communication with other components will be performed over the Homematic
(HmIP) radio protocol. The radio transmission is done on a non-exclusive transmis-
sion path; thus, disturbance cannot be completely excluded. Disturbance impacts
can be caused by switching processes, electric motors or electric appliances.
The range within buildings can differ strongly from the range outside (in
open air).

ENGNORSWE DANFINPOLRUS
11
Device overview
ENG
4 Device overview
Device overview (see page 4 fig. 1)
(A) Installation bottom
(B) Room control unit Display
(C) Display
(D) System button (teaching button
and LED)
(E) Removable setting wheel
Target/actual temperature
humidity
Condensation warning
Window-open symbol
Battery symbol
Radio transmission
Boost mode
Manual operation
Automatic operation
Holiday mode
Heating
Cooling
Operating lock
Target temperature
Date/time
Offset
Display overview

POL RUSFINDAN SWENORENG
12
Device overview
ENG
Short designation of
device
RTD 61001-N1
Supply voltage 2x 1.5 V LR03/micro/AAA
Power consumption max. 50 mA
Battery service life 2 years (normally)
Protection type IP20
Contamination degree 2
Ambient temperature 0 to 50 °C
Dimensions (W x H x D) 86 x 86 x 24.6 mm / 32 mm
Weight 110 g (including batteries)
Radio frequency 868.3 MHz/869.525 MHz
Receiver category SRD category 2
Typical radio range 250 m (in open air)
Duty Cycle < 1 % per h/< 10 % per h
Mode of action Type 1
Guidelines 2014/53/EU Radio installations
4.1 Technical data

ENGNORSWE DANFINPOLRUS
13
Commissioning
ENG
5 Commissioning
5.1 Teaching the device
In order be integrated into the Alpha IP System and to communicate with other
devices, the room control unit Display must be taught-in first. The room control unit
Display is taught-in directly to the Alpha IP base station, or in conjunction with the
radiator thermostats, to the Alpha IP Access Point. In case of direct teaching-in, the
configuration is done on the device itself; in case of teaching-in via the Access Point,
it is done via the Alpha IP app.
5.1.1 Teach-in without Alpha IP Access Point (stand-alone operation)
For teach-in, keep a minimum distance of 50 cm between the devices.
The teach-in process can be interrupted by shortly pressing the teach-in key
again. This is confirmed by a short flash in red colour of the device LED.
If no teaching-in is performed, the teach-in mode is finished automatically
after 30 seconds.
If the room control unit shall be taught-in to the Alpha IP Base station, the two
devices to be linked must be set to teach-in mode.

POL RUSFINDAN SWENORENG
14
Commissioning
ENG
1. Select the desired channel at the Alpha IP base station (see Alpha IP Base station
instructions).
2. Press the System key (A) of the Alpha IP base station for 4 seconds, until the LED
of the System key flashes rapidly in orange.
9The device LED starts to flash in orange.
3. Take off the room control unit Display from the installation bottom (see page
5 fig. 3).
4. Pull out the insulating strip from the battery compartment, or insert batteries
(see page 5 fig. 4) If Batteries are inserted, shortly press the system key (D) in
order to activate the teach-in mode.
9The teach-in mode is activated automatically for 3 minutes.
9The device LED flashes in orange.
The LED will light up in green after a successful teach-in process. If the LED
lights up red, repeat the process.
5.1.2 Teaching-in to Alpha IP Access Point
For a control via the Alpha IP app, the teaching-in must of the RTD 61001-N1 must
be performed via the Access Point (HAP 21001). Teach-in the device as follows:
ÖThe Alpha IP Access Point has been set up via the Alpha IP App (see instructions
HAP 21001).
1. Open the Alpha IP app on the smart phone.
2. Select the menu item Teach-in device.
3. Release the room control unit Display from the installation bottom (see page 5
fig. 3).
4. Pull out the insulating strip from the battery compartment, or insert batteries
(see page 5 fig. 4). If Batteries are inserted, shortly press the system key (D) in

ENGNORSWE DANFINPOLRUS
15
Commissioning
ENG
order to activate the teach-in mode.
5. The device is displayed automatically in the Alpha IP app.
6. Enter the last four ciphers of the device number (SGTIN) or scan the supplied QR
code for confirmation. The device number can be found below the QR code or
in the battery compartment.
The LED will light up in green after a successful teach-in process. If the LED
lights up red, repeat the process.
7. Follow the instructions in the app.
5.2 Installation
The place of installation can be selected flexibly due to the battery operation. In-
stallation can be performed with screws, with the supplied adhesive strips, or in a
flush-type box.
5.2.1 On-surface installation
ÖSelect an appropriate installation position.
1. Ensure that the installation position is free from hidden lines.
2. If necessary, release the device from the installation bottom with a suitable
screwdriver (see page 5 fig. 3).
3. Hold the installation bottom to the installation position. Take care to align the
installation bottom correctly (see page 4 fig. 2a/b).
4. Align the installation bottom horizontally.
5. Mark two diagonally opposite bore holes using the installation bottom (see page
5 fig. 2a).

POL RUSFINDAN SWENORENG
16
Commissioning
ENG
If wood walls are present, the screws can be screwed directly into the wood.
Pre-drilling with a 1.5 mm wood drill can facilitate the installation of the
screws.
6. For stone walls, drill the holes at the marked positions with a 5 mm masonry drill.
7. Insert dowels into the bores.
8. Install the installation bottom using the supplied screws (see page 4 fig. 5).
9. Position the device onto the installation bottom and latch it in (see page 5 fig. 3).
5.2.2 Installation in flush-type box
The fixing holes on the installation bottom can be used for installation on a flush-
type box (see page 4 fig. 2b).
1. If necessary, release the device from the installation bottom with a suitable
screwdriver (see page 5 fig. 3).
2. Align the installation bottom horizontally on the flush-type box.
3. Install the installation bottom with suitable screws (see page 4 fig. 2b).
4. Position the room control unit Display onto the installation bottom and latch it
into the clips (see page 5 fig. 3).
5.2.3 Installation with adhesive strips
Depending on the ground, installation can be performed using the supplied dou-
ble-sided adhesive tapes. Installation is possible on different grounds, as e. g. ma-
sonry, furniture, tiles or glass.

ENGNORSWE DANFINPOLRUS
17
Operating modes and configuration
ENG
If the installation is done with adhesive strips, the installation surface must
be smooth, level, undamaged, clean, and free from grease and solvents.
1. Select an appropriate installation position.
2. Remove the protective foil from one side of the adhesive strip.
3. Fix the adhesive strip on the back side of the installation bottom in the recesses
provided for this (see page 4 fig. 2c).
4. Remove the protective foil from the other side of the adhesive strip.
5. Align the device horizontally to the desired position and press it on.
6 Operating modes and configuration
The setting wheel E (see page 4 fig. 1) provides the operating functions of the de-
vice. Depending on the configuration, the settings are transmitted to the Alpha IP
Base station or to the Alpha IP app.
6.1 Configuration menu
The configuration menu is opened by pressing and holding the setting wheel (E).
The following symbols/menus are available by rotating the setting wheel; shortly
pressing the wheel will select them.
Section Display Meaning
6.1.1 Automatic operation
6.1.2 Manual operation
6.1.3 Holiday mode*
6.1.4 Operating lock*

POL RUSFINDAN SWENORENG
18
Operating modes and configuration
ENG
Section Display Meaning
6.1.5 Programming of heating profiles*
6.1.6 Date and time*
6.1.7 Offset temperature*
6.1.8 Selewction of temperature display/humidity*
6.1.9 Configuration of the base station*
6.1.10 Connection test
*only selectable in standalone operation
6.1.1 Automatic mode
Do the following to activate automatic operation:
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “ “ and confirm the selection by shortly pressing the
setting wheel.
6.1.2 Manual operation
Proceed as follows to activate manual operation:
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “ “ and confirm the selection by shortly pressing the
setting wheel.
3. Turn the setting wheel in order to set the desired temperature.

ENGNORSWE DANFINPOLRUS
19
Operating modes and configuration
ENG
6.1.3 Holiday mode
The holiday mode can be used if a fixed temperature shall be kept during a certain
span of time (e. g. for a vacation or during a party).
Proceed as follows to activate the holiday mode:
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “ “ and confirm the selection by shortly pressing the setting
wheel.
3. Set the “Start-/End” time and date by rotating the setting wheel. Confirm each
selection by shortly pressing the setting wheel. “S” shows the starting time, “E”
shows the end time.
4. Set the temperature to be kept during the defined time by turning he setting
wheel and confirm your selection by shortly pressing the wheel.
6.1.4 Operating lock
The operation at the device can be locked in order to prevent the unintentional
change of settings e. g. by accidental touch. Proceed as follows in order to activate
or deactivate the operation lock:
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “ “ and confirm the selection by shortly pressing the setting
wheel.
3. Select “ON” by turning the wheel in order to activate the operation lock, or
“OFF” in order to deactivate the operation lock. Confirm the selection by press-
ing the wheel shortly.
6.1.5 Programming of heating profiles
This menu item allows to make settings for heating or cooling profiles and the cre-
ation of week profiles according to own requirements.

POL RUSFINDAN SWENORENG
20
Operating modes and configuration
ENG
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “ “ and confirm the selection by shortly pressing the setting
wheel.The following subordinate menu items are available in the menu, to be
accessed by turning the wheel:
“type” for switching over the base station between the modes Heating and Cool-
ing. (deactivated when multi-IO box is connected)
1. Turn the setting wheel (E) to “HEAT” for heating or “COOL” for cooling and
confirm by shortly pressing the wheel.
“Pr.nr” for the selection of the week profile number (“no. 1, no. 2 ... no. 6”).
1. Select the number of the desired profile and confirm the selection by shortly
pressing the setting wheel.
“Pr.Ad” for the individual setting of the week profiles („no. 1, no. 2 ... no. 6“). Up
to 6 heating phases (13 switch-over points) can be set in the week profile for every
week day for the selected heating profile. Programming is made for the selected
days for the time from 00:00 to 23:59 o’clock.
1. In the menu item “Pr.Ad”, select the number of the desired profile by turning
the setting wheel (E) and confirm the selection by shortly pressing the wheel.
2. Select the desired week day/working day/weekend/all days by turning the set-
ting wheel (E) and confirm the selection by shortly pressing the wheel.
3. Confirm the start time of 00:00 o’clock by shortly pressing the setting wheel (E).
4. Select the desired temperature for the starting time by turning/pressing and
confirm.
5. Select and confirm the time indicated in the display by turning/pressing the set-
ting wheel.
6. Select the desired temperature for the set period by turning/pressing and con-
firm.
7. Repeat the process for the complete period from 00:00 to 23:59 o’clock.