Alpha WSER UNIVERSAL MOTOR User manual

WSER UNIVERSAL MOTOR GUIDE p1
Protection Index: IP44
Up to 15 remotes (or channels) may be assigned to each motor
Thermal protection will engage after 4 minutes of continuous running
Power: 240V/50Hz
M.ETHOD A
MB.ETHOD
Only works for the first remote
assigned to the motor
You can now use the remote
to control the motor.
You can now use the remote
to control the motor.
Press the UP and DOWN buttons
simultaneously, then release.
Press the UP and DOWN buttons
simultaneously, then release.
Turn power on, the motor
will vibrate.
Press the STOP button once,
the motor will vibrate.
Press the STOP button once,
the motor will vibrate.
1
1
11
1
11
1
Press the red button on the
motor for 1 second.
METHOD C. (Use Method C, if Method A or B do not work) C 3an only be used if you cut and restore power to the motor 3 times. You must allow
seconds before restoring power each time and you must allow the motor to vibrate properly each time. After the third cycle, you may assign the remote.
Can be used at any time.
AC Power
antenna
neutral wire ( )blue
ground wire ( )green
live wire (b )rown
AC Power
240V
up
stop
down
1
111
6
11
1
1
(motor moves a few millimeters at a time unless button held down for 3 secs)
Pr ss the STOP button once.ePress the P button once,U
the tor will vibrate.mo The tor is now in “step bymo
step” ode.m
Pr ss the UP and DOWN buttonse
simultaneously, then release.
Pr sstheSTOPbutton6e
times.
Press the UP and DOWN buttons
simultaneously, then release. Press the DOWN button
once, the motor will vibrate. The UP and DOWN directions of
the motor have been reversed.
Hold the red button on the motor down for 3 seconds, The motor will vibrate. The UP and Down directions of the
motor have been reversed.
Method A
Method B
1. TECHNICAL SPECIFICATIONS
2. WIRE CONNECTIONS
3. ASSIGNING A REMOTE TO A MOTOR (you have 10 seconds to complete the task)
4. CHANGING THE MOTOR’S DIRECTION
5. TURN ON “STEP BY STEP” MODE
ALPHA SUPPORT PHONE (02) 4355 4775

WSER UNIVERSAL MOTOR GUIDE p2
111
1
11
1
2
111
2
7. (firstly, move the blind to the desired position)SETTING THE TOP LIMIT
8. (firstly, move the blind to the desired position)SETTING THE BOTTOM LIMIT
6. TURN OFF “STEP BY STEP” MODE (motor will run up and down as normal)
Press the UP and DOWN buttons
simultaneously, then release. Pr ss the STOP button twice.ePress th UP button once, thee
motor ill vibrate.wTop mit is now set.li
Press he UP and DOWN buttonst
simultaneou ly, th release.sen Press the S O bu on twiceTP tt Press the DOWN button once,
the moto will vibrate.r
Bott limit is now set.om
Pr ss the UP and DOWN buttonse
simultaneously, then release. P ess the STOP button once.r Press the DOWN button once,
the motor will vibrate. The tor will now runmo
normally.
11. ASSIGNING AN EXTRA REMOTE (OR CHANNEL) TO A MOTOR VIA THE ORIGINAL REMOTE
Press the UP and DOWN
buttons simultaneously,
then release.
Press the UP and DOWN
buttons simultaneously,
then release.
You can now use the new
remote to control the motor.
Press the STOP button
8 times, the motor will
vibrate.
Press the STOP button
once, the motor will
vibrate.
1
18
1
11
Original Original NEW NEW
11
1
4
111
4
9. OPDELETING THE T LIMIT
10. OTTOMDELETING THE B LIMIT
Pr ss the UP and DOWN buttonse
Pr ss the UP and DOWN buttonse
simultaneously, then release.
simultaneously, then release.
Botto limit is deleted.m
Top limit is deleted.
Pr ss the DOWN button once, thee
Pr ss theUP button once, thee
motor will vibrate.
motor will vibrate.
Press the STOP button 4 times.
Press the STOP button 4 times.
ALPHA SUPPORT PHONE (02) 4355 4775

WSER UNIVERSAL MOTOR GUIDE p3
14. (firstly, move the blind to the desired position)CHANGING THE THIRD LIMIT
NOTE: The third limit will be deleted automatically if either the top or bottom limits are deleted.
13. SETTING THE THIRD LIMIT (midway position, somewhere between top and bottom limits)
1
4
Press the STOP button 4 times.
Hold down or 2 secondsf
The motor will vibrate. Holding down the stop button for 2 seconds
will send the motor to the third limit position.
1
4
Press the STOP button 4 times.
Hold down or 2 secondsf
The motor will vibrate. Holding down the stop button for 2 seconds
will send the motor to the third limit position.
12. DELETING A REMOTE (OR CHANNEL) FROM A MOTOR
Press the UP and DOWN buttons
simultaneously, then release.
Press the STOP button
7 times.
Press the UP button once,
the motor will vibrate.
This remote (or channel) has now
been deleted from the motor.
Method A. This will delete the individual remote (or channel) you are using.
11
1
7
11
1
6
Press the UP and DOWN buttons
simultaneously, then release.
All remotes have been
deleted .from the motor
Press the UP button once,
the .motor will vibrate
Pr ss the stop buttone
6times.
Method B. W NING: ALLAR This will delete remotes assigned to the motor
(firstly, move the blind to the desired position)
ALPHA SUPPORT PHONE (02) 4355 4775
Handy Tips
1. sensor or RS005 motion sensor, there is constant radio communicationIf this motor is used on an awning and works with the Alpha RS001 wind-light
between the motor and sensor. If the motor doesn't receive radio communication from the sensor for 35 minutes after opening, the motor will
automatically close the awning as a protective measure. This indicates that there is either a problem that gation, or in the case of theneeds investi
motion sensor that the batteries might need changing.
3. possible. It should sound like one button click when both are pressed.When pressing up and down simultaneously during setup, be as precise as
4. seconds for the motor to time out, then try again.If you catch yourself making an error during a setup process, stop and allow 10
5. Do not hold any buttons down during setup process unless specifically told to do so. A half second press should be plenty and allow 1 second
between presses.
6. ct channel before you assign it to a motor. This is a common mistake.If you are using a multi-channel remote, make certain that it is on the corre
!Announcement
2. may result in a change of limit position due to a change in blindAlways roll the blind down and up before setting the top limit. Failure to do so
tension. Simply setting the bottom limit first will prevent this happening.
1. grams. compatible with these motors.The RE101 remote has been used as an example here in dia All Alpha remotes are
2. Strong local RF levels from other equipment may affect some setup functions. If a step fails, simply repeat the process.
3. Be careful not to speed through the setup process until you are 100% sure of what you are doing.
4. ay with them.These motors and accessories are not toys, do not allow children to pl
5. Ambient operating temperature is: -10 C to +55 C
6. All Alpha products may be subject to change without notice.
Other Alpha Engine manuals
Popular Engine manuals by other brands

KCFA
KCFA SV-X3 Series Installation and Wiring

CHERUBINI
CHERUBINI BLUE WAVE RX instructions

Briggs & Stratton
Briggs & Stratton POWER BUILT 120000 Operator's manual

Man
Man D 2866 LUE 605 Repair manual

Advanced Micro Controls Inc.
Advanced Micro Controls Inc. SMD23E2 user manual

brel-motors
brel-motors BLE 25 installation manual