WSS/WSM SERIES MOTOR GUIDE p1
TUBULAR MOTOR INSTRUCTION
for mechanical limit switch standard motor WSS series
and manual override motor WSM series
WARNING
Before assembling and using the tubular motor, please carefully read the specification, in order
to avoid the damage of the motor or injury of person.
Each of these products has a rigorous testing before leaving factory so you can assemble it as a
whole and use safely. Prohibiting opening it and changing the inner parts without authorization
(except adjusting limited replacement stroke), if not, we do not bear the sequent.
1. TUBULAR MOTOR GENERAL DESCRIPTION
Our tubular motor, adopting advanced technology, is developed by our own company. There are four
main parts of the motor: motor, break, gearbox, and limit switch. The motor can be widely used in
awning, roller blinds, garage door, projection screen, etc.
Features:
1. Small, light and low noise, hidden.
2. Stable and durable limit switch makes sure the motor has excellent performance for long.
3. Thermal Protector can make the tubular motor stop automatically when working temperature is
over 130 . When the temperature goes down (about 15 minutes), the motor can work again.℃
4. Perfect shape, simple operation, convenient to assemble.
5. The rate of insulation is F. 2.
2. NAME AND STRUCTURE OF MODEL NUMBER
W S S
Torque (Nm)
Outside diameter (mm)
S = Standard type
M = Manual type
C = Clutch type
A = Bracket
B = Limit Switch
C = Crown
D = Shell
E = Drive Adapter
NAME STRUCTURE
ALPHA SUPPORT PHONE (909) 307-2320
3. INSTALLATION
A. Motor and Aluminum Tube Instruction
1. Set the crown and drive adapter into the fixed place on the motor and ensure the slot in the
crown and the drive key on the imit ring fix compactly. The driver adapter is fixed by the clipl
spring.
2. Insert tubular motor into luminum ube. The crown should match with the luminum ubeat at
completely. If using round luminum ube, the crown and luminum ube mush be fixed by screwsat at
or rivets. The screws which fix the crown must not reach the limit ring (see Pic 3); the rivetsNote:
which fix the driver must be installed as Pic 4 and should be equally spaced around the luminuma
tatube on one circle; if the octagonal luminum ube is used, it depends whether need rivets or not.
3. Inset the end cap into the end of luminum ube and fix.at
B. Installation
1. Before installation, the horizontal and vertical measuring must be made.
2. Firstly fix the bracket into the end board, and then fix the end board and the orbit into the wall.
3. Install the luminum ube into the bracket. Make sure the luminum ube isa t a t horizontal and is
vertical with the door and window.
4. Use the unlock dowel to fix the luminum ube with bracket.at
C. Installation of window shutter and transmission shaft
1. Connect the wire according to Pic 8. Switch the power. After the motor stops running at one
direction (the close state), cut off the power.
2. Put the shutter into the orbit from above the luminum ube. After that the windowa t should be in
the close state.
3. Fixing the shutter and luminum ube: first fix the place where install the screws, which should beat
equally spaced in luminum ube line. Make sure the shutter doesn’t curl after being fixed. Ensureat
the screw not reach the face of the tubular motor.
4. Make sure the connection between shutter and luminum ube is Ok and the forcea t bearing is
balanced.
5. The installation of tubular motor, aluminum ube and shutter see Pic 6.t
WSS/WSM SERIES MOTOR GUIDE p2
horizontal
vertical
Pic 5
Pic 3
Pic 6
Pic 4
1 = Bracket
2 = End Cap
3 = Drive Adapter
4 = Tubular Motor
5 = Crown
6 = Bracket
7 = Aluminium Tube
8 = Shutter / Curtain
ALPHA SUPPORT PHONE (909) 307-2320
Limit ring
Crown
Aluminium tube
Aluminium tube
Middle
Shaft
Driver adapter
D. Wiring Pic 7
Notice: For safety, you must connect the wires (L and N) correctly.
E. Limit Switch Adjustment
1. Switch the power, and the shutter will rise. Adjust the limit switch according to the mark on the
limited switch. ( ) means the motor’s clockwise and anti-clock wise running; Use the
adjusting pole to adjust at ‘+‘ direction and the journey of the shutter will increase; Use the
adjusting pole to adjust at ‘–‘ direction the journey of the shutter will reduce. Repeat readjustment
till settings are satisfactory.
2. Adjust the limit switch according to the mark in the operation. The motor may be damaged if
wrongly adjusted.
4. MANUAL TYPE
For manual type motor, when the power is unavailable, the motor can work through operating the
hand crank. Connect one end of the link with the handle worm and the end with the hand crank, then
the door can go up and down by operating the hand crank.
M type motor also can realize out door operation under the help of wall-cross lock. Connect the
universal-join linking stick with the handle worm, then insert one end of the linking stick and wall
cross stick in to the speed-reduce institution (fixed on the wall) respectively. At last the wall cross stick
can be derived through turning around the hand crank to do the work of the motor.
5. SAFETY NOTE
1. Repair and maintenance for the motor should be implemented by the authorized person.
2. After opening the package, check the motor to make sure it’s not deformed or damaged and the
accessories are completely attached.
3. The electrical outlet must include the grounding wire connection terminal and it should be
connected with the ground fully.
4. The motor should be tested without load, to insure that it does not make abnormal noise.
6. TROUBLESHOOTING
WSS/WSM SERIES MOTOR GUIDE p3
S.N. Trouble Reason Solution
Tubular motor cannot run or starts too
slowly or with a loud noise.
Tubular motor stops running when
working.
The motor does not travel the required
distance.
1. Incorrect power connection.
2. Wrong installation or over weight.
3. The voltage is too low.
1. Reached the max limit switch.
2. Working time lasts too long.
The limits are not properly adjusted to the
customer’s requirements.
1. Check the power connections.
2. Correct the installation.
3. Check the load.
1. Adjust the limit switch according to diagrams.
2. Re-try after cooling the tubular motor for 30 mins.
Adjust the limit switch according to the diagram
1
2
3
Neutral wire (white)
L1 (red)
L2 (black)
Ground wire (green)
M
ALPHA SUPPORT PHONE (909) 307-2320
for standard and manual
override motors
120V/60Hz

This manual suits for next models

1

Other Alpha Engine manuals

Alpha WSME User manual

Alpha

Alpha WSME User manual

Alpha WSERD50 User manual

Alpha

Alpha WSERD50 User manual

Alpha WSER User manual

Alpha

Alpha WSER User manual

Alpha WSER UNIVERSAL MOTOR User manual

Alpha

Alpha WSER UNIVERSAL MOTOR User manual

Alpha WSERD30-B 1/30C User manual

Alpha

Alpha WSERD30-B 1/30C User manual

Popular Engine manuals by other brands

stijn helsen SH4U instructions

stijn helsen

stijn helsen SH4U instructions

Scania DI14 82 Operator's manual

Scania

Scania DI14 82 Operator's manual

Multiplex HIMAX C 4220-0510 instructions

Multiplex

Multiplex HIMAX C 4220-0510 instructions

MTU V 4000 M70 operating instructions

MTU

MTU V 4000 M70 operating instructions

Magnetic BR Series Operation and maintenance manual

Magnetic

Magnetic BR Series Operation and maintenance manual

MTD 547cc Operator's manual

MTD

MTD 547cc Operator's manual

Nanni T6.280 Operator's manual

Nanni

Nanni T6.280 Operator's manual

Siemens SINAMICS S 1PH7 Configuration manual

Siemens

Siemens SINAMICS S 1PH7 Configuration manual

SMARTWINGS WR01-15CH manual

SMARTWINGS

SMARTWINGS WR01-15CH manual

Lombardini LDW 502 Service manual

Lombardini

Lombardini LDW 502 Service manual

SOMFY J4 RTS Installer's guide

SOMFY

SOMFY J4 RTS Installer's guide

Volvo D4 Operator's manual

Volvo

Volvo D4 Operator's manual

Detroit Diesel MBE4000 Application and installation guide

Detroit Diesel

Detroit Diesel MBE4000 Application and installation guide

Paccar MX Series Programming guide

Paccar

Paccar MX Series Programming guide

Leroy-Somer HPM 250 Installation and Maintenance

Leroy-Somer

Leroy-Somer HPM 250 Installation and Maintenance

Rotax OM-912 Operator's manual

Rotax

Rotax OM-912 Operator's manual

Toyama TDE35S owner's manual

Toyama

Toyama TDE35S owner's manual

Kubota WG972-E2 Workshop manual

Kubota

Kubota WG972-E2 Workshop manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.