- 1 -
IES5028G Series
Industrial Ethernet Switch
User Manual
Shenzhen 3onedata Technology Co., Ltd.
Tel: +86-755-26702668 Fax: +86-755-26703485
www.3onedata.com
【
Introduction
】
The series are high-performance, cost-effective smart
rack-mounted full Gigabit industrial Ethernet switches. The
increase in bandwidth elevates the data transmission capability,
and it's very suitable for the application of large-scale industrial
network. The switch various advanced administration functions
such as IGMP, GMRP, DHCP Server/Client, STP/RSTP/MSTP,
QOS, port mirroring, LLDP, etc. The switches also support
SNMPv1/v2/v3 (Simple Network Management Protocol), CLI,
Web Management, TELNET management for more convenient
device management. Combined with enhanced ACL control and
anti-attack function, the management will be more secure.
The switches are in compliance with the FCC and CE
standards, and supports 2-way redundant AC inputs and 2-way
relay fault alarm output. Users can select flexibly according to
actual environment. It adopts industrial no fan design, and is fit
for severe industrial environment at a working temperature of
-40 ℃~75 ℃, which can meet various industrial application
requirements and provide reliable and economic solutions for
Ethernet access.
【
Packing list
】
The industrial Ethernet switch is shipped with the following items.
If any of these items are missing or damaged, please contact your
customer service representative for assistance.
Industrial Ethernet switch ⅹ1
Documentation and software CD ⅹ1
User manual ⅹ1
Rackmount ears ⅹ2
Power cords ⅹ2
【
Features
】
Support IGMP Snooping and GMRP filter multicast packet
Support QOS of IEEE 802.1p/1Q TOS/DiffServ to promote
network stability
Support SNMP v1/v2/v3
Support IEEE802.1X, HTTPS, and SSH to enhance network
security
Support link static / dynamic aggregation to optimize
bandwidth
Support ACL function to enhance flexibility and security of
network management
Support bandwidth management, ensuring network stability
Support RMON, effectively improve network monitoring and
predictive ability
Support port mirroring for online debugging
Support STP/RSTP/MSTP to enhance network stability
Support IEEE802.1Q VLAN for easy network planning
Working temperature: -40℃-75℃
Support two 100VAC~240VAC power inputs
Support two power supplies for redundancy and high
reliability
Support two relay alarms to enhance reliability
No fan design, industrial and rack-mounted installation
【
Panel layout
】
IES5228G-4GS-8GC-16GT
Front panel
Rear panel
1. Restore factory settings
2. Console port
3. Systems running LED
4. The power LEDs (P1, P2)
5. Relay alarm LED
6. 10/100/1000BaseT(X) (RJ45) ports
- 2 -
7. Ethernet port Link/ACT LEDs(1~28)
8. 1000Base-FX SFP port
9. Rackmount ears
10. Relay 1 output terminal block
11. Power 1 input power socket
12. Grounding screw
13. Relay 2 output terminal block
14. Power 2 input power socket
15. 10/100/1000BaseT(X) or 1000Base SFP slot combo ports
【
Power supply input
】
The switch support dual redundant power supplies: Power Supply
1 (P1) and Power Supply 2 (P2). The switch rear panel provides
power sockets for AC100~240V power entered. Socket diagram is
as follows:
The redundant power can be used independently. P1 and P2 can
supply power at the same time, once either of these two powers
fails, another power can acts as backup automatically to ensure
reliability of the network.
Important notice:
1. Power ON operation: Please connect to the device at first and
then connect to the power supply with power cable.
2. Power switch “—” means power ON, “O” means power OFF.
3. Power OFF operation: First, the powers switch to the "O" side
and then disconnect the power supply. Finally disconnect the
connection between the device and the power cord.
【
Dimension
】
Unit (mm)
【
Relay connection
】
Relay access terminals in the rear panel of the device, next to the
power input parts, R+ and R- are in the middle of the relay alarm
output section. It is used to detect both power failure and port
failure. The open circuit state in normal non alarm state, when
there is any alarm information to the closed state. This series of
switch device have 2 relay alarm output, external alarm lights or
alarm buzzer or external switch signal acquisition device in order
to timely notify operators when an alarm occurs.
【
Console port
】
This switch provided 1pcs procedure test port based in serial port.
It adopts RJ45 interface, located in top panel, can configure the
CLI command through RJ45 to DB9 female cable.
【
Communication connector
】
10/100/1000BaseT(X) Ethernet port
The pinout define of RJ45 port display as below, connect by UTP
or STP. The connect distance is no more than 100m. 100Mbps is
used 120Ωof UTP 5, 10Mbps is used 120Ωof UTP 3 ,4, 5.
RJ 45 port support automatic MDI/MDI-X operation. That can
connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7,
8 Corresponding connections in MDI. 1→3, 2→6, 3→1, 4→7,
5→8, 6→2, 7→4, 8→5, are used as cross wiring in the MDI-X
port of Converter and HUB. In MDI/MDI-X, 100/1000Base-TX
PIN defines is as follows:
PIN MDI MDI-X
1 BI_DA+/TX+ BI_DB+/RX+
2 BI_DA-/TX- BI_DB-/RX-
3 BI_DB+/RX+ BI_DA+/TX+
4 BI_DC+/—BI_DD+/—
5 BI_DC-/—BI_DD-/—
6 BI_DB-/RX- BI_DA-/TX-
7 BI_DD+/—BI_DC+/—
8 BI_DD-/—BI_DC-/—
Note:10Base-T/100Base-TX, “TX±”transmit data±, “RX±”receive data±,
1 8
- 3 -
“—”not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
Gigabit MDI (straight-through cable)
Gigabit MDI-X (Cross over cable)
MDI/MDI-X auto connection makes switch easy to use for
customers without considering the type of network cable.
1000Base SFP fiber port
1000BaseSFP optical fiber interface is used SFP optical module
communication through optical fiber transmission, can choice
different SFP module according to different transfer distance.
Fiber interface must use for pair, TX port is transmit side, must
connect to RX (receive side). The fiber interface support loss line
indicator.
Suppose: If you make your own cable, we suggest labeling the
two sides of the same line with the same letter (A-to-A and
B-to-B, shown as below, or A1-to-A2 and B1-to-B2).
【
LED Indicator
】
LED indictor light on the front panel of product, the function of
each LED is described in the table as below.
System Indication LED
LED State Description
PWR
(P1~P2)
ON Power is being supplied to
power input PWR input
OFF Power is not being supplied
to power input PWR input
RUN
ON/OFF System is not running well
Blinking System is running well
Alarm
ON
When the alarm is enabled,
power or the port’s link is
inactive.
OFF Power and the port’s link is
active, the alarm is disabled.
Link/ACT
(1~28)
ON Port connection is active
Blinking Data transmitted
OFF Port connection is not active
【
Installation
】
Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Power: 100-240VAC power input
5. Environment: working temperature: -40~75℃
Storage Temperature: -40~85℃
Relative humidity 5%~95%
Rack mount installation
In most of industrial application, it is convenience to use rack
mount installation, the step of installation is as follows:
1. Check if have rack mount installation tools and components
(The package provided parts of components)
2. Check installation place strong or not, have the place to install
the device or not.
3. Put the device into rack, aim at the screw hole of device and
rack, fixed it in strong screw. Easy and convenience to
operation.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
- 4 -
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.
【
Specification
】
Technology
Standard: IEEE802.3, IEEE802.3u, IEEE802.3z/ab, IEEE802.3x,
IEEE802.1d, IEEE802.1w, IEEE802.1s, IEEE802.1q,
IEEE802.1p, IEEE802.1x, IEEE802.3ad
Flow control: IEEE802.3x flow control, Back Pressure flow
control
Protocol
ARP、ICMP、TCP、UDP、DHCP、DNS、HTTP、Telnet、RSTP、
MSTP、LLDP、LACP、IGMP、GMRP、SNMP
Interface
RJ45 port: 10/100 /1000BaseT(X), flow control, full / half duplex,
adaptive work mode, MDI/MDI-X adaptive
Combo port: 1000Base-X SFP slot or 10/100/1000Base-T(X)
Gigabit SFP port: 1000Base-X SFP slot
Console port: CONSOLE Admin Port (RJ45)
Alarm port: 5-core 5.08mm wiring terminal (R+/R-),
2-way relay alarm output
Transmission distance
Twisted-pair: 100m (standard CAT5/CAT5e cable)
Multi-mode fiber: 1310nm, 2km
Single mode fiber: 1310nm, 20/40Km
1550nm, 60/80/100/120Km
LED indicator
Power indicator: P1/P2
Alarm indicator: ALM
Operation indicator: RUN
Port connection / operation status indicator: Link/ACT (1~28)
Switch attribute:
Transmission mode: store-and-forward
MAC address: 16K
Cache: 12Mb
Switched Bandwidth: 56G
1000M forwarding rate: 1488100pps
Power Supply
AC input voltage: 100VAC~240VAC
AC input terminal: three-phase socket with rocker switch
Support 2-way AC input
Consumption
No-load consumption: 20.3W@220VAC
Full-load consumption: 25W@220VAC
Mechanical characteristics
Shell: IP30 protection, metal shell
Installation: 19” rack-mounted
Weight: 3.9kg
Dimension (L*W*H): 440mm×285mm×43mm
Working environment
Working temperature: -40℃~75℃
Storage temperature: -40℃~85℃
Humidity: 5%~95% (no condensation)
Industry Standard:
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 4
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 4
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Certification:
CE, FCC, RoHS, UL508 (Pending)
Warranty: 5 years

Other 3One data Switch manuals

3One data IES3012G Series User manual

3One data

3One data IES3012G Series User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data IES6220 Series User manual

3One data

3One data IES6220 Series User manual

3One data TNS5500 Series User manual

3One data

3One data TNS5500 Series User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IPS3110 Series User manual

3One data

3One data IPS3110 Series User manual

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES5024-P User manual

3One data

3One data IES5024-P User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data PS5010G-2GS-8PoE User manual

3One data

3One data PS5010G-2GS-8PoE User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES2008-8T-P48 User manual

3One data

3One data IES2008-8T-P48 User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES2005 User manual

3One data

3One data IES2005 User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data TNS5000D Series User manual

3One data

3One data TNS5000D Series User manual

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data

3One data PS1005G-1GT-4POE Operating and maintenance instructions

Popular Switch manuals by other brands

NuTone 69W quick guide

NuTone

NuTone 69W quick guide

Westermo Viper TBN Series user guide

Westermo

Westermo Viper TBN Series user guide

elobau 207KS24N02 manual

elobau

elobau 207KS24N02 manual

Hycontrol DP600 instruction manual

Hycontrol

Hycontrol DP600 instruction manual

IOGear GCL1908 quick start guide

IOGear

IOGear GCL1908 quick start guide

D-Link DES-5600 user guide

D-Link

D-Link DES-5600 user guide

Altronix NetWay SP2P Series manual

Altronix

Altronix NetWay SP2P Series manual

Alcatel OS6850-P48 manual

Alcatel

Alcatel OS6850-P48 manual

Toa YW-1022 instruction manual

Toa

Toa YW-1022 instruction manual

PTN WUH4ARC-8K user manual

PTN

PTN WUH4ARC-8K user manual

Datacom Systems VS-1200-S Series user guide

Datacom Systems

Datacom Systems VS-1200-S Series user guide

Bryston SWB2 Hookups and settings

Bryston

Bryston SWB2 Hookups and settings

D-Link DUB-H4 - Hub - USB Quick installation guide

D-Link

D-Link DUB-H4 - Hub - USB Quick installation guide

schmersal AZM300B-I2-ST-1P2P instructions

schmersal

schmersal AZM300B-I2-ST-1P2P instructions

Daewoo DAEPC-7 user manual

Daewoo

Daewoo DAEPC-7 user manual

Enabling Devices 9008 manual

Enabling Devices

Enabling Devices 9008 manual

ADTRAN TRACER 1280050L1 quick start guide

ADTRAN

ADTRAN TRACER 1280050L1 quick start guide

Vigitron MaxiiNet Vi3005 installation manual

Vigitron

Vigitron MaxiiNet Vi3005 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.