  7. Security System
  8. •
  9. Alula RE116-U User manual

Alula RE116-U User manual

USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 1of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
#2
#1 #2
#1 Battery
RE150 Special Transmitter
SIREN+
SIREN- 4.7K
RE116-U Wireless Siren
Features
•Remote Wireless Siren
•Works with any panel with siren terminals
•Special transmitter at panel sends siren signals
•Siren cadence synchronized to panel
•Automatically follows panel beep volume
•Wall-powered, with backup power on CR123A battery
•Can use multiple Sirens on one panel
•Cover tamper
•Unparalleled wireless range
•Low Battery indication
•3x4x1.25 inches
How it works:
Key Instructions
TYPICAL HARDWIRE CONNECTIONS
Refer to Siren Hardware Connections for specific panel connections and settings.
Connect Special Transmitter to Control Panel Siren:
•Remove Special Transmitter battery during install.
•MOUNT SPECIAL TRANSMITTER OUTSIDE
ANY METAL CANS!
1. Panel siren output
terminals signal alarm or
status beeps
2. Transmitter tells
wireless siren to make
noise, following siren
terminals pattern
3. Wireless siren
makes same noise
pattern as panel
4. Wireless siren sends
supervisories, low battery and
tamper statuses
(GE systems only)
Special
Transmitter
More than one
siren can be
used
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 2of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
ENROLLMENT
Open the Siren battery door, giving access to the programming switches.
Power the Special Transmitter with its battery.
Power the Siren with its battery.
Enrolling Special Transmitter into Siren –to send panel siren signals to Siren
 Put Siren Function in ENROLL Mode.
 Press and release the Special Transmitter tamper switch.
The Siren will beep 4 times, indicating enrollment.
 IMPORTANT: Put cover on Special Transmitter.
 Put Siren Function Switches in RUN Mode.
Select low volume or HIGH VOLUME status beeps
DO THESE STEPS ONLY IF PANEL IS A GE SYSTEM.
Enrolling Siren in Panel –to monitor both Special Transmitter and Siren
(Siren only talks GE wireless):
•If you want to have Siren monitor the Special Transmitter
In Step 2 above, instead of using the Special Transmitter’s tamper switch to
enroll, pull and replace Special Transmitter battery. Siren will beep 8 times.
❖IMPORTANT: You must NOT enroll Special Transmitter in panel.
Panel will go CRAZY with alarms.
After step 4 above, enroll Siren into GE panel:
With Panel in enroll mode…Cycle tamper switch on Siren. Enroll in Group 10.
Put cover on Siren.
Plug Siren in wall.
System is ready to operate.
MULTIPLE SIRENS:
You can enroll multiple sirens in one system. Just enroll the same single original
Special Transmitter in the 2nd Siren. Simply repeat Steps 1-4 with the 2nd Siren.
TO CHECK SPECIAL TRANSMITTER SIREN LINK:
Tamper, or install the battery in the Special Transmitter Siren will beep twice.
HIGH VOLUME STATUS BEEPS
low volume status beeps
ENROLL
RUN
ENROLL
RUN
1
2
1 2
1
2
1 2
HIGH VOLUME STATUS BEEPS
low volume status beeps
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 3of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
Operation
•Alarm
Siren follows panel alarm pattern.
Some panels (Lynx, 2GIG) cannot drive siren without AC power.
•GE panels only:
•Supervision
Siren sends supervisory signals to panel IF:
Siren has AC power.
AND, if Special Transmitter is enrolled in Siren…
Siren has heard signal from Special Transmitter in previous 60
minutes.
•Tamper
When cover is opened on Siren, or on Special Transmitter if enrolled.
Tamper Switch
Function
Switches
Blue LED
•Enroll Mode:
Short ON flashes when
waiting to enroll… Short
OFF after Special
Transmitter is enrolled
Green LED
•ON if AC Present.
•Flickers when
hearing wireless signals
from its enrolled
Transmitter.
Battery “+”
Special Transmitter
Battery “+”
- Terminal #1
+ Terminal #2
Wireless Siren
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 4of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
Siren Specifications
Device Behavior: Siren Supervision in GE panels acts like a
Door/Window Battery & Tamper
Supervisory Time 64-68 minutes
Alarm Patterns: Follows panel Siren ON/OFF Directly
Shortest ON pulse: 250 ms
Shortest OFF Pulse: 250 ms
Alarm Sound Intensity 85dB, minimum, at 1m
Receiver: Dual antenna diversity
Transmitter> Dual antenna Dirersity
Electrical Connection: US 2-prong Electrical outlet blades
Mounting hardware: Secure with outlet plate mounting screw
Terminal wire capacity: 16 Gauge
Backup Battery Life: 48 hours cumulative, non-rechargeable
Back-up Battery: CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3x4x1.25 inches
Specifications subject to change without notice.
Notices
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric Company,
Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies Inc., and NAPCO
Security Systems, Inc., respectively.
Alula products will function with one of either GE, DSC, Napco, 2GIG or Honeywell systems. However,
no Alula product is produced by, endorsed by, nor is officially associated with GE, Honeywell, Napco,
2GIG or DSC. Alula recommends verifying proper enrollment and operation, per control panel
installation instructions, at installation.
Warranty
Alula will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by Alula could void the user's authority to operate this equipment.
FCC ID: U5X-RE116 (Siren)
FCC ID: U5X-RE150 (Special Transmitter)
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE116 (Siren)
IC: 8310A-RE150 (Special Transmitter)

Other Alula Security System manuals

Alula RE617 User manual

Alula

Alula RE617 User manual

Alula Connect+ User manual

Alula

Alula Connect+ User manual

Alula RE103P Instruction Manual

Alula

Alula RE103P Instruction Manual

Alula RE626 User manual

Alula

Alula RE626 User manual

Alula BAT WIFI User manual

Alula

Alula BAT WIFI User manual

Alula RE603P Instruction Manual

Alula

Alula RE603P Instruction Manual

Alula Connect+ RE6100P-XX-X DKIT User manual

Alula

Alula Connect+ RE6100P-XX-X DKIT User manual

Alula RE251 Hidden Panic User manual

Alula

Alula RE251 Hidden Panic User manual

Alula Connect+ User manual

Alula

Alula Connect+ User manual

Popular Security System manuals by other brands

Frontpoint Security System quick start guide

Frontpoint

Frontpoint Security System quick start guide

Tunze 7607/2 Instructions for use

Tunze

Tunze 7607/2 Instructions for use

AlphaVision ML user manual

AlphaVision

AlphaVision ML user manual

GE Interlogix CONCORD Express user manual

GE Interlogix

GE Interlogix CONCORD Express user manual

CSL DualCom Pro quick guide

CSL

CSL DualCom Pro quick guide

Lasermet AA-05-PIR instruction manual

Lasermet

Lasermet AA-05-PIR instruction manual

Bosch VSS7915/00T installation instructions

Bosch

Bosch VSS7915/00T installation instructions

Texecom Ricochet Impaq Contact-W user manual

Texecom

Texecom Ricochet Impaq Contact-W user manual

Security Brands RIDGE 2.0 quick start guide

Security Brands

Security Brands RIDGE 2.0 quick start guide

Hiltron security PROTEC6GSM user manual

Hiltron security

Hiltron security PROTEC6GSM user manual

Carefree 1050A owner's manual

Carefree

Carefree 1050A owner's manual

Valcom VIP-998 quick start guide

Valcom

Valcom VIP-998 quick start guide

Bosch DIVAR DIP-6080-00N Quick installation guide

Bosch

Bosch DIVAR DIP-6080-00N Quick installation guide

New Cosmos USA DeNova Detect 806NIT user manual

New Cosmos USA

New Cosmos USA DeNova Detect 806NIT user manual

Titan TRS05RX manual

Titan

Titan TRS05RX manual

First Alert 3035DF Operations & installation guide

First Alert

First Alert 3035DF Operations & installation guide

Soundoff Signal Armada A200 manual

Soundoff Signal

Soundoff Signal Armada A200 manual

System Sensor SpectrAlert S1224MCW Installation and maintenance instructions

System Sensor

System Sensor SpectrAlert S1224MCW Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.