manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Alula
  6. •
  7. Security System
  8. •
  9. Alula RE116-U User manual

Alula RE116-U User manual

Other Alula Security System manuals

Alula RE103P Instruction Manual

Alula

Alula RE103P Instruction Manual

Alula RE617 User manual

Alula

Alula RE617 User manual

Alula RE251 Hidden Panic User manual

Alula

Alula RE251 Hidden Panic User manual

Alula Connect+ User manual

Alula

Alula Connect+ User manual

Alula RE603P Instruction Manual

Alula

Alula RE603P Instruction Manual

Alula RE626 User manual

Alula

Alula RE626 User manual

Alula BAT WIFI User manual

Alula

Alula BAT WIFI User manual

Alula Connect+ RE6100P-XX-X DKIT User manual

Alula

Alula Connect+ RE6100P-XX-X DKIT User manual

Alula Connect+ User manual

Alula

Alula Connect+ User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 1of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
#2
#1 #2
#1 Battery
RE150 Special Transmitter
SIREN+
SIREN- 4.7K
RE116-U Wireless Siren
Features
•Remote Wireless Siren
•Works with any panel with siren terminals
•Special transmitter at panel sends siren signals
•Siren cadence synchronized to panel
•Automatically follows panel beep volume
•Wall-powered, with backup power on CR123A battery
•Can use multiple Sirens on one panel
•Cover tamper
•Unparalleled wireless range
•Low Battery indication
•3x4x1.25 inches
How it works:
Key Instructions
TYPICAL HARDWIRE CONNECTIONS
Refer to Siren Hardware Connections for specific panel connections and settings.
Connect Special Transmitter to Control Panel Siren:
•Remove Special Transmitter battery during install.
•MOUNT SPECIAL TRANSMITTER OUTSIDE
ANY METAL CANS!
1. Panel siren output
terminals signal alarm or
status beeps
2. Transmitter tells
wireless siren to make
noise, following siren
terminals pattern
3. Wireless siren
makes same noise
pattern as panel
4. Wireless siren sends
supervisories, low battery and
tamper statuses
(GE systems only)
Special
Transmitter
More than one
siren can be
used
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 2of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
ENROLLMENT
Open the Siren battery door, giving access to the programming switches.
Power the Special Transmitter with its battery.
Power the Siren with its battery.
Enrolling Special Transmitter into Siren –to send panel siren signals to Siren
 Put Siren Function in ENROLL Mode.
 Press and release the Special Transmitter tamper switch.
The Siren will beep 4 times, indicating enrollment.
 IMPORTANT: Put cover on Special Transmitter.
 Put Siren Function Switches in RUN Mode.
Select low volume or HIGH VOLUME status beeps
DO THESE STEPS ONLY IF PANEL IS A GE SYSTEM.
Enrolling Siren in Panel –to monitor both Special Transmitter and Siren
(Siren only talks GE wireless):
•If you want to have Siren monitor the Special Transmitter
In Step 2 above, instead of using the Special Transmitter’s tamper switch to
enroll, pull and replace Special Transmitter battery. Siren will beep 8 times.
❖IMPORTANT: You must NOT enroll Special Transmitter in panel.
Panel will go CRAZY with alarms.
After step 4 above, enroll Siren into GE panel:
With Panel in enroll mode…Cycle tamper switch on Siren. Enroll in Group 10.
Put cover on Siren.
Plug Siren in wall.
System is ready to operate.
MULTIPLE SIRENS:
You can enroll multiple sirens in one system. Just enroll the same single original
Special Transmitter in the 2nd Siren. Simply repeat Steps 1-4 with the 2nd Siren.
TO CHECK SPECIAL TRANSMITTER SIREN LINK:
Tamper, or install the battery in the Special Transmitter Siren will beep twice.
HIGH VOLUME STATUS BEEPS
low volume status beeps
ENROLL
RUN
ENROLL
RUN
1
2
1 2
1
2
1 2
HIGH VOLUME STATUS BEEPS
low volume status beeps
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 3of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
Operation
•Alarm
Siren follows panel alarm pattern.
Some panels (Lynx, 2GIG) cannot drive siren without AC power.
•GE panels only:
•Supervision
Siren sends supervisory signals to panel IF:
Siren has AC power.
AND, if Special Transmitter is enrolled in Siren…
Siren has heard signal from Special Transmitter in previous 60
minutes.
•Tamper
When cover is opened on Siren, or on Special Transmitter if enrolled.
Tamper Switch
Function
Switches
Blue LED
•Enroll Mode:
Short ON flashes when
waiting to enroll… Short
OFF after Special
Transmitter is enrolled
Green LED
•ON if AC Present.
•Flickers when
hearing wireless signals
from its enrolled
Transmitter.
Battery “+”
Special Transmitter
Battery “+”
- Terminal #1
+ Terminal #2
Wireless Siren
USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
SIGNAL TO SIREN
RE116-U_47-0051-02_RevA Page 4of 430-Apr-18
Tech Support Line: (888)88-ALULA (888) 882-5852
alula.net
Siren Specifications
Device Behavior: Siren Supervision in GE panels acts like a
Door/Window Battery & Tamper
Supervisory Time 64-68 minutes
Alarm Patterns: Follows panel Siren ON/OFF Directly
Shortest ON pulse: 250 ms
Shortest OFF Pulse: 250 ms
Alarm Sound Intensity 85dB, minimum, at 1m
Receiver: Dual antenna diversity
Transmitter> Dual antenna Dirersity
Electrical Connection: US 2-prong Electrical outlet blades
Mounting hardware: Secure with outlet plate mounting screw
Terminal wire capacity: 16 Gauge
Backup Battery Life: 48 hours cumulative, non-rechargeable
Back-up Battery: CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3x4x1.25 inches
Specifications subject to change without notice.
Notices
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric Company,
Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies Inc., and NAPCO
Security Systems, Inc., respectively.
Alula products will function with one of either GE, DSC, Napco, 2GIG or Honeywell systems. However,
no Alula product is produced by, endorsed by, nor is officially associated with GE, Honeywell, Napco,
2GIG or DSC. Alula recommends verifying proper enrollment and operation, per control panel
installation instructions, at installation.
Warranty
Alula will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by Alula could void the user's authority to operate this equipment.
FCC ID: U5X-RE116 (Siren)
FCC ID: U5X-RE150 (Special Transmitter)
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE116 (Siren)
IC: 8310A-RE150 (Special Transmitter)