Model Numbers
RHODULP-01 . . . . . . . . . . . . . .Pressure Housing with Integrated I/O Board
and Clear Bubble (ƒ0)
RHODULP-02 . . . . . . . . . . . . . .Housing with Integrated I/O Board and
Smoked Bubble (ƒ1.0)
Electrical
Voltage . . . . . . . . . . . . . . . . . . . .24-28 VAC
Power . . . . . . . . . . . . . . . . . . . . . .52 watts
Power-On In-Rush Current . .2.5 A
Surge Protection
Video . . . . . . . . . . . . . . . . . . . . .Series resistor of 3.9 Ω; low-capacitance Zener
suppressor of 6.5 V, 1500 watts, 500 watts,
8/20 µsec impulse, 500 watts, 10 kA impulse
rated gas tube
Manchester/SensorNet . . . . .Isolation transformer coupled, 2000 Vrms;
PTC resettable fuse protects transformer;
TVS rated at 5.6 V, 40 A, 0.1 joules, 8/20 µsec
impulse, 500 watts, 10 kA impulse rated
gas tube
RS-422 . . . . . . . . . . . . . . . . . . . .Series resistors of 33 Ω; TVS rated at 5.6 V,
40 A, 0.1 joules, 8/20 µsec impulse, 500 watts,
10 kA impulse rated gas tube
Power Line . . . . . . . . . . . . . . .TVS rated at 60 V, 250 A, 1.5 joules, 8/20 µsec
impulse, 500 watts, 10 kA impulse rated
gas tube
Mechanical
Construction
Enclosure . . . . . . . . . . . . . . . . .Aluminum
Color . . . . . . . . . . . . . . . . . . . . . .White
Height . . . . . . . . . . . . . . . . . . . . .325 mm (12.8 in)
Diameter . . . . . . . . . . . . . . . . . . .409 mm (16.1 in)
Weight . . . . . . . . . . . . . . . . . . . . .3.63 kg (8.0 lbs)
Bubble . . . . . . . . . . . . . . . . . . . . .Acrylic
Maximum Distances From Power Source
Dome and housing to be connected to a Class 2 LPS, 24 VAC, 80 VA power
source (do not exceed maximum outdoor Class 2 ratings of 30 VAC, 100 VA).
Connectors (on integrated I/O board)
Manchester/SensorNet. . . . . .Two-position 3.5 mm Euro-style terminal
block
RS-422 . . . . . . . . . . . . . . . . . . . . .Four-position 3.5 mm Euro-style terminal
block
Video Output . . . . . . . . . . . . . .Female BNC
I/O Connector . . . . . . . . . . . . . .Spring contact gold fingers for mate with
SpeedDome Ultra housing/eyeball assemblies
Alarm . . . . . . . . . . . . . . . . . . . . . .Low pressure alarm pre-wired (alarm inputs
2-4 are not used)
Environmental
Weatherproof Standard . . . . .NEMA 4X/IP67
Temperature
Operating . . . . . . . . . . . . . . . . .-40° to 50° C (-40° to 122° F)
Humidity . . . . . . . . . . . . . . . . .0 to 95% RH (non-condensing)
Storage . . . . . . . . . . . . . . . . . . .-10° to 50° C (14° to 122° F)
Regulatory
Emissions . . . . . . . . . . . . . . . . . .FCC: 47 CFR Part 15, Subpart B Class A
CE: EN55022 Class B
CE: EN6100-6-1
ICES-003
Immunity . . . . . . . . . . . . . . . . . .CE: EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . .UL: UL2044
CE: EN60950
Accessories
WM20G . . . . . . . . . . . . . . . . . . .Aluminum gooseneck wall mount bracket
for RHODULP pressurized housings
ACA2 . . . . . . . . . . . . . . . . . . . . . .Aluminum corner mount bracket for
RHODULP pressurized housings, to be used
in conjunction with WM20G
APM3 . . . . . . . . . . . . . . . . . . . . . .Aluminum pole mount bracket for
RHODULP pressurized housings, to be used
in conjunction with WM20G
RHONKIT* . . . . . . . . . . . . . . . .Nitrogen recharge kit with hose, regulator
and tank. Tank holds sufficient gas for three
housings
RHONTANK* . . . . . . . . . . . . . .Nitrogen tank for use with RHONKIT or
equivalent. Tank holds sufficient gas for
three housings
RHONREG . . . . . . . . . . . . . . . .Hose and regulator kit for RHONTANK or
equivalent. For use when gas is to be sourced
locally
* Please check with your salesperson for recharge kit availability in your
geographic region.
Note: For proper performance, the dome housing must be pressurized
using 99.998% dry nitrogen.
AMERICAN DYNAMICS SPEEDDOME®ULTRA PRESSURIZED OUTDOOR DOME HOUSING
Product specifications and availability subject to
change without notice.
Certain product names mentioned herein may be trade
names and/or registered trademarks of other companies. VS412-02 08/05 L
©2005 Sensormatic Electronics Corporation