Blast Chiller (Modular) - AP26BC-2T
Project Name: _________________________________
Item #: _______________________________________
Quantity: _____________________________________
Type: Modular Blast Chiller
Model: AP26BC-2T
Certications
Standard Features
Capacity
Product Yield
Warranty
5800 SE 78th St. Ocala, FL 34472-3412
T: 1.800.327.3015 • 352.245.7055
www.americanpanel.com
Up to two mobile racks (not included), maximum dimensions of
26”W x 36”D x 73.5”H.
520 lbs. - 160 - 38˚F in 90 minutes
600 lbs. - 160 - 38˚F in 120 minutes
The warranty covers all parts found to be defective and the labor required to
replace them for a period of one year from the date of shipment.
Warranty excludes food probes.
AP26BC-2T_Spec 2/21
Overview: American Panel’s modular series of blast chillers and shock
freezers make site restrictions a thing of the past. These units are assembled
in the eld, the same way a typical walk-in is erected. No more wondering
how you’re going to get that large piece of equipment through the door. The
modular series also features a consolidated evaporator fan assembly. This
places all of the components within the cabinet on one side, which greatly
reduces the overall footprint of the unit. American Panel quality and precision
in a exible format to t your needs. 7” glove safe capacitative touchscreen
control allows for simple 3 step control, or use the customizable quick-start
button for one touch operation.
PERFORMANCE:
• Blast chilling (soft or hard) lowers the food core temperature from 160°F to
38°F within 90 minutes.
• Chilling times will vary somewhat, depending on the food quantity, initial
temperature, density, moisture content, specic heat, and type of container.
• The airow has a high velocity, indirect pattern designed to cool all levels at
identical rates.
• Time/temperature chilling rates meet or exceed all FDA, NSF, and state
regulations.
TOUCHSCREEN CONTROLS:
• 7” glove-safe capacitive touchscreen
• Easily readable from across the kitchen
• User friendly interface and quick access to all functions
• Quick-start button for one touch operation
• Capable of automated defrost and sanitation cycles
• HACCP logger, data download via optional Wi card or USB port
• Available cycles - Soft Chill, Hard Chill, Quick Start
• Two core temperature probes are provided
ASSEMBLY:
• Unit manufactured using cam-lock insulated panels that are sized for easy
assembly and ingress
• Internal electrical connections done via quick connect male-female
connectors to minimize eld wiring
CABINET CONSTRUCTION:
• Constructed of polished type 304 stainless steel,
• 4” of CFC-free, high density polyurethane insulation.
• Fully rounded interior corners
• Removable magnetic door gasket.
• The cabinet oor is a 7 /8” thick insulated panel with NSF cove
• Integral 2” long ramp
• Clearance: 15” at the top cabinet for service. 30.5” at the front for door
opening.
REFRIGERATION SYSTEM:
• Refrigeration system is complete with all components including controls,
evaporator, TXV and solenoid valves, and blower system
• E-coated (electro-deposition coated) multiple circuits evaporator designed
specically for blast chilling operation
• Wash-down type motorized impeller fans with sealed ball bearing and
overload protection
• Hinged swing out vent panel for easy evaporator cleaning
Blast Chiller (Modular) - AP26BC-2T
Options and Accessories
Controller
Dimensions
Specications
5800 SE 78th St. Ocala, FL 34472-3412
T: 1.800.327.3015 • 352.245.7055
www.americanpanel.com AP26BC-2T_Spec 2/21
INSTALLATION: A detailed installation manual is provided. It must be carefully followed to ensure proper
operation and to protect your rights under the warranty.
Electrical Refrigeration Connections Required Condensing Unit
Model V Hz PH A MCA MOPD Liquid Line Suction Line Type Ref BTU/HR* Ship Weight
AP26BC-2T 208 60 1 15.5 20 20 2 x 1/2” 2 x 1 1/8”
Med.Temp.
40˚F - -10˚F R404A 68,000 2,328 lbs.
* - Rating at 14˚F SST and 105˚F cond. temp.
Soft Chilling: The air temperature is held in the range of 28°F to
35°F, ideal for delicate food items. The chilling cycle is completed
when the food core temperature reaches 38°F.
Hard Chilling: The air temperature is lowered to and held within
a range of 10°F to 20°F. When the food core temperature reaches
60°F, the air temperature rises to a range of 28°F to 35°F. The
chilling cycle is completed when the food core temperature
reaches 38°F.
Shock Freeze: Not available on APC26BC-2T
Quick Start: Programmable single touch button to start a cycle.
Used for the most popular settings for the customer. This allows
for starting any chilling or freezing cycle with one touch.
ADDITIONAL FEATURES:
Thawing (Optional): Not available on AP26BC-2T.
Holding: At the end of any cycle, the unit will automatically switch
to a holding mode which will keep the food at holding temperature
until the cycle is stopped.
Defrost: A heated defrost cycle is included within the unit’s
controller programming.
Product Names: Store up to 150 product names.
• Cabinet Sanitation: The ultraviolet system sanitizes all metal surfaces within
the cabinet in a preset time of 30 minutes.
• USB HACCP Interface: Use a standard USB thumb drive to easily download
HACCP data. The information recorded includes date, time, cycle identication,
recipe name, and product core temperature at prescribed intervals.
• Wi-Fi Connectivity: Supported functions include peer-to-peer connectivity,
remote monitoring over the local network, HACCP data download and alarm
notications via e-mail.
• 2” or 4” Insulated Floor Panels: Allow for height increase to detail shown
above.
• Remote Refrigeration: RCU12BC, available in air cooled and water cooled
conguration
• Prison Security Package
• Extra Food Probes: Two probes are standard, up to two additional probes can
be provided.
• Mobile Racks: Model APR13-26 will accommodate 26 full size steam table
pans (12”x20”x2 1/2”) or 13 full size sheet pans (18”x26”).
• Reversed Cabinet: The entire assembly is manufactured so that it is a mirror
image of the cabinet shown above.
• Second Door: For pass-thru operation (increases depth by 2”)
• Alternate refrigerant conguration available
• Right hand hinge available

Other American Panel Chiller manuals

American Panel MODULAR Series Instruction Manual

American Panel

American Panel MODULAR Series Instruction Manual

American Panel HurriChill AP3BCF30-1 Administrator Guide

American Panel

American Panel HurriChill AP3BCF30-1 Administrator Guide

American Panel HurriChill AP3BCF30-1 Instruction Manual

American Panel

American Panel HurriChill AP3BCF30-1 Instruction Manual

American Panel AP20BCF200-3-XL Administrator Guide

American Panel

American Panel AP20BCF200-3-XL Administrator Guide

American Panel AP20BC Series Administrator Guide

American Panel

American Panel AP20BC Series Administrator Guide

American Panel Blast Chiller AP40BC250-12 Manual

American Panel

American Panel Blast Chiller AP40BC250-12 Manual

American Panel AP26BC-3T User manual

American Panel

American Panel AP26BC-3T User manual

American Panel AP3BCF30-1-P Administrator Guide

American Panel

American Panel AP3BCF30-1-P Administrator Guide

American Panel AP46BC-2T User manual

American Panel

American Panel AP46BC-2T User manual

American Panel AP26BC-1T User manual

American Panel

American Panel AP26BC-1T User manual

American Panel AP20BC-1T User manual

American Panel

American Panel AP20BC-1T User manual

Popular Chiller manuals by other brands

AERMEC Variable Multi Flow ANL Series Installation and maintenance manual

AERMEC

AERMEC Variable Multi Flow ANL Series Installation and maintenance manual

Laird OW 4002 manual

Laird

Laird OW 4002 manual

Cornelius VANGUARD 245 instruction manual

Cornelius

Cornelius VANGUARD 245 instruction manual

Carrier 19FA Series installation instructions

Carrier

Carrier 19FA Series installation instructions

Norcool Cu-350 user manual

Norcool

Norcool Cu-350 user manual

Tefcold SDU1375 datasheet

Tefcold

Tefcold SDU1375 datasheet

Skope Pegasus PG100HC-2 user manual

Skope

Skope Pegasus PG100HC-2 user manual

KREYER Chilly Picture guide

KREYER

KREYER Chilly Picture guide

Daikin EWAA008D2V3P User reference guide

Daikin

Daikin EWAA008D2V3P User reference guide

Trane CGCL 200 Installation operation & maintenance

Trane

Trane CGCL 200 Installation operation & maintenance

York YCAV0569 Installation operation & maintenance

York

York YCAV0569 Installation operation & maintenance

Western Zeta Rev HE FC APPLICATION AND OPERATING PRINCIPLE

Western

Western Zeta Rev HE FC APPLICATION AND OPERATING PRINCIPLE

Ibx RC-1 user manual

Ibx

Ibx RC-1 user manual

Zanussi 110001 Specifications

Zanussi

Zanussi 110001 Specifications

Advantage Engineering Titan instruction manual

Advantage Engineering

Advantage Engineering Titan instruction manual

Elkay 2D Installation, care & use manual

Elkay

Elkay 2D Installation, care & use manual

Thermal Care Accuchiller KSE Operation, installation, and maintenance manual

Thermal Care

Thermal Care Accuchiller KSE Operation, installation, and maintenance manual

Zip 801621UK user guide

Zip

Zip 801621UK user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.