
iv | Model 900 ADA / Model 930 Sulfur Pit Analyzers
Maximum Sample Gas Pressure ................................................................................... 2-4
Electrical Requirements.................................................................................................. 2-4
Maximum Start-Up Power ..................................................................................... 2-4
Supply Voltage .......................................................................................................... 2-4
Status Relays .................................................................................................................... 2-5
Sample Gas Flow Rate.................................................................................................... 2-5
Ambient Limits ................................................................................................................ 2-5
Temperature............................................................................................................... 2-5
Humidity.................................................................................................................... 2-5
Maximum Altitude ................................................................................................... 2-5
Sample Transport ............................................................................................................ 2-5
Instrument Air Requirements ....................................................................................... 2-5
Physical Dimensions (on Backpan).............................................................................. 2-5
Cable Entry Ports, Type 200 Disconnect Enclosure.................................................... 2-6
Approvals and Certifications......................................................................................... 2-6
ATEX and IECEx Certificates and Analyzer Markings....................................... 2-7
Purged Analyzers ATEX and IECEx Certificates and Markings ....................... 2-7
Systems with 30 psia Pressure Transducer (Maximum 63 kPag
Sample Gas Pressure) ..................................................................................2-15
Systems with 100 psia Pressure Transducer (Maximum 350 kPag
Sample Gas Pressure) ..................................................................................2-15
Heater Plate ATEX and IECEx Certificates and Marking................................ 2-16
Disconnect Enclosure Type 200 ATEX and IECEx Certificates and Marking . 2-23
CHAPTER 3 INSTALLATION AND START-UP................................................................... 3-1
Safety Considerations..................................................................................................... 3-2
Pre-Installation Requirements....................................................................................... 3-2
Storage Prior to Installation .................................................................................... 3-2
Uncrating and Inspecting the Analyzer................................................................ 3-3
Tools and Equipment Required.............................................................................. 3-4
Installing the Mechanical Components....................................................................... 3-5
Installing the Analyzer............................................................................................. 3-5
Location and Environment.................................................................................. 3-5
Installing the Optical Bench Assembly ................................................................. 3-8
Installing the Sample System................................................................................ 3-13
Installing the ASR900 Sample Probe................................................................ 3-13
Installing the Sample and Vent Lines................................................................ 3-13
Installing the Instrument Air Line ................................................................... 3-19
Installing the Span Gas Line............................................................................. 3-20
Connecting I/O Signals, Alarm Relay Contacts, and AC Power ............................ 3-21
Start-Up and Verification ............................................................................................. 3-27
Purged Analyzers ................................................................................................... 3-28
Powering Up the Analyzer.................................................................................... 3-30
Start-Up Diagnostic Checklist .......................................................................... 3-35
Sample System Leak Check .................................................................................. 3-38
Manually Zeroing the Analyzer........................................................................... 3-40