manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Amprobe
  6. •
  7. Measuring Instrument
  8. •
  9. Amprobe VPC-10 User manual

Amprobe VPC-10 User manual

Other manuals for VPC-10

1

Other Amprobe Measuring Instrument manuals

Amprobe ACD-45PQ User manual

Amprobe

Amprobe ACD-45PQ User manual

Amprobe ACD-400 User manual

Amprobe

Amprobe ACD-400 User manual

Amprobe TMD Series User manual

Amprobe

Amprobe TMD Series User manual

Amprobe DM-5 User manual

Amprobe

Amprobe DM-5 User manual

Amprobe MO-100 User manual

Amprobe

Amprobe MO-100 User manual

Amprobe LM631A User manual

Amprobe

Amprobe LM631A User manual

Amprobe ACDC-3400 IND User manual

Amprobe

Amprobe ACDC-3400 IND User manual

Amprobe WT-60 User manual

Amprobe

Amprobe WT-60 User manual

Amprobe ECB50A User manual

Amprobe

Amprobe ECB50A User manual

Amprobe SOLAR-100 User manual

Amprobe

Amprobe SOLAR-100 User manual

Amprobe THWD-3 User manual

Amprobe

Amprobe THWD-3 User manual

Amprobe AMB-45 User manual

Amprobe

Amprobe AMB-45 User manual

Amprobe TMA40-A User manual

Amprobe

Amprobe TMA40-A User manual

Amprobe MEGATEST 5000 User manual

Amprobe

Amprobe MEGATEST 5000 User manual

Amprobe THWD-5 User manual

Amprobe

Amprobe THWD-5 User manual

Amprobe TMA10A User manual

Amprobe

Amprobe TMA10A User manual

Amprobe MAN02-A User manual

Amprobe

Amprobe MAN02-A User manual

Amprobe TMA5 User manual

Amprobe

Amprobe TMA5 User manual

Amprobe TIC 300 PRO User manual

Amprobe

Amprobe TIC 300 PRO User manual

Amprobe PQ55A User manual

Amprobe

Amprobe PQ55A User manual

Amprobe WT-40 User manual

Amprobe

Amprobe WT-40 User manual

Amprobe ALC-110 User manual

Amprobe

Amprobe ALC-110 User manual

Amprobe LM-100 User manual

Amprobe

Amprobe LM-100 User manual

Amprobe WT-50 User manual

Amprobe

Amprobe WT-50 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Voltage and Continuity Tester
Model VPC-10
Instruction Manual
m Safety Information
• Never use the tester if it or its test leads appear damaged
• Never apply more than 600V DC or 600V AC RMS between any terminal
and earth ground.
(If the LED turns on it indicates the presence of voltage at the probe tip.
• When using the probes, do not touch the metal probe tips.
• Disconnect the live test lead before disconnecting the common test lead.
• Before each use, verify the tester’s operation by measuring a known voltage.
Automatic Operation
The tester automatically turns on when you place the probes across a complete circuit.
The tester selects continuity or dc or ac voltage mode based on the resistance or volt-
age between the probes. The tester automatically turns off when you remove the
probes from the complete circuit.
Measuring Voltage
Connect test leads across the source or load under measurement, the LEDs turn on at
between 70% and 100% of their rated voltages.
Testing for Continuity
Turn off circuit power before testing
Beeper indicates shorts lasting 1ms or longer
OPEN SHORT or 0-85 KΩ
Specifications
Function Range Accuracy
AC voltage(V) 24,120,208,240,277,480,600 -30% to 0% of reading
DC voltage(V) 6,12,24,36,48,110,220 -30% to 0% of reading
Continuity test: Audible threshold 0-85kΩ, Continuity beeper 2KHz
Maximum Voltage Between any Terminal and Earth Ground:
600 V Overvoltage Category III
Input Impedance: 1MΩ
Temperature: Operating: 5˚C (41˚F) to 40˚C (104˚F)
Storage : -30°C to +60°C
Altitude: Operating: 2000m; Storage:10,000m
Relative Humidity:
80% for Temp up to 31˚C decreasing linearly to 50% RH at 40˚C
Battery Type and Life: AA(2); 350 hours with NEDA 15˚F or IEC R6
Safety: Complies with EN61010-1:1993 for use in overvoltage CAT III environments
Pollution Degree: 2
For indoor use only
EMC Regulations: EN50081-1, EN50082-1
DC Voltage
600V DC maximum
600
AC Voltage
600V RMS maximum
45Hz to 66Hz
Continuity Continuity
r Beeping
220V AC
Battery Test and Replacement
Replace the batteries when
touching the leads together no
longer turns on the
continuity LED.
WARRANTY
Congratulations! Your new instrument has been quality crafted according to quality
standards and contains quality components and workmanship. It has been inspected
for proper operation of all of its functions and tested by qualified factory technicians
according to the long-established standards of our company.
Your instrument has a limited warranty against defective materials and/or workmanship
for one-year from the date of purchase provided that, in the opinion of the factory, the
instrument has not been tampered with or taken apart.
Should your instrument fail due to defective materials, and/or workmanship during this
one-year period, a no charge repair or replacement will be made to the original pur-
chaser. Please have your dated bill of sale, which must identify the instrument model
number and serial number and call the number listed below:
Repair Department
ATP – Amprobe, TIF, Promax
Miramar, FL
Phone: 954-499-5400
800-327-5060
Fax : 954-499-5454
Website: www.amprobe.com
Please obtain an RMA number before returning product for repair. Outside the U.S.A.
the local representative will assist you. Above limited warranty covers repair and
replacement of instrument only and no other obligation is stated or implied.
P/N: ATP VPC-10Manual printed in China
2xAA
Disconnect probes from
Voltag. Do not over-tighten
screws
Miramara, Florida 33025
Tel: 954-499-5400 Toll Free: 800-327-5060 Fax: 954-499-5418