AMX Massio MCP-108 User manual

QUICK START GUIDE
MCP-108 Massio™ 8-Button ControlPad with Knob
Overview
This guide pertains to the MCP-108 Massio 8-Button ControlPad with Knob
(FG2102-08). The purpose of this document is to illustrate how the device is to be
installed and set up in its simplest configuration by a trained technician.
Additional Documentation
Additional documentation for this device is available at www.amx.com. Refer to the
Massio ControlPads Instruction Manual for additional details on installing, upgrading,
and wiring the MCP-108.
You can also access this Quick Start Guide online by using your mobile device to scan
the QR code located on the rear panel of the ControlPad.
What’s in the Box?
The following items are included with the MCP-108:
• (1) metal mounting bracket
• (2) 3-pin female connectors
•(3)4-pinfemaleconnectors
• (1) sheet of 70 pre-printed button labels
• (4) M3.5 x 30MM screws
• (4) #6-32 x 1.25 screws
Power
You can apply power to the MCP-108 via any Power-over-Ethernet (PoE) injector or
switch which conforms to the 802.3af standard. Before installing and mounting the
ControlPad, test to see that it can receive power.
Applying Power
Applying power to the MCP-108 requires category cable and a PoE injector, such as the
PS-POE-AF-TC available from AMX. The network must be connected through the PoE
injector to send power to the ControlPad. The category cable should only run through a
common building. (A common building is defined as: Where the walls of the structure(s)
are physically connected and the structure(s) share a single ground reference.)
1. Connect the PoE injector to an AC outlet (100-240VAC) using a standard power
cord.
2. Connect the switch category cable to the Data In port on the PoE injector.
3. Using a separate category cable, connect the Data & Power Out port on the PoE
injector to LAN Port on the ControlPad.
Installation
The MCP-108 mounts onto standard 2 gang US, UK, or EU back boxes. Each type of
back box must adhere to its own specific safety approvals.
Dimensions
4 11/16" x 6" x 1" (119mm x 152.5mm x 26mm)
Button Labeling
Massio ControlPads come with a set of clear plastic Button Caps, which are designed to
fit tightly over the pushbuttons, and allow you to place a label on each button according
to the requirements of your particular installation.
Massio ControlPads also come with a pre-printed acetate sheet with a range of 70
(pre-cut) button label inserts. The button labels provided will accommodate most
installations, but it is also possible to print your own button labels on acetate for
custom button labeling.
NOTE: It is best to install the button labels before mounting the ControlPad. Doing so
keeps you from disassembling the ControlPad after mounting it.
Installing Acetate Button Labels
Follow these steps to install acetate button labels:
1. Remove the faceplate from the frame and invert the faceplate to expose its
backside.
2. Remove the cone and diffuser from the button. The cone and diffuser are adhered
together and should not be separated.
3. Peel off the desired Button Label from the included acetate sheet. If you have
printed your own custom button labels on acetate, cut each button label to fit
inside the Button Caps.
• Custom button labels must be cut to a 14mm (0.55") square to fit securely
inside the Button Caps.
• The thickness of the acetate used must not exceed .004” (0.10 mm).
4. Place the Button Cap face-down, and insert the Button Label into the bottom of
the Button Cap (FIG. 1).
FIG. 1 PLACING A BUTTON LABEL INSIDE A BUTTON CAP
Orient the Button Label inside the Button Cap so that the two clips are located on the
left and right sides of the readable text on the Button Label, as indicated in FIG. 1. Be
sure to place the Button Label face-down inside the Button Cap, otherwise the label will
be seen in reverse once the Button Cap is installed.
5. Place the cone and diffuser back over the button and snap the cone into place on
the faceplate. Repeat steps 2-5 for any additional buttons. When finished, mount
the ControlPad.
Mounting the ControlPad
Follow these steps to the ControlPad:
1. Install the 2-gang back box into the surface of the desired location for the
ControlPad.
2. Once the back box is installed and secured, secure the metal mounting bracket to
the back box using the provided screws (FIG. 2).
FIG. 2 SECURE THE METAL BRACKET TO BACK BOX
3. Peel the plastic covering off of the insulator on the rear panel of the ControlPad.
You can discard the plastic covering after removing it.
4. Make all necessary connections to the ports on the rear panel of the ControlPad.
Be sure to connect category cable to the LAN port to supply power to the
ControlPad. See the Applying Power section for more information.
5. Attach the ControlPad frame to the mounting bracket by hooking the top of the
frame onto the extended lips at the top of the bracket (FIG. 3).
FIG. 3 ATTACHING THE FRAME TO THE METAL BRACKET
6. Press the sides of the frame to snap them into place.
7. Press the bottom corners of the ControlPad frame to snap them into place. The
two metal clips on the mounting bracket should align with the open spaces
located at the bottom of the frame. The clips should fit inside these spaces and
lock the frame into position on the mounting bracket (FIG. 4).
FIG. 4 METAL CLIPS FROM MOUNTING BRACKET LOCKING FRAME ONTO BRACKET
8. Connect the faceplate to the frame by snapping the top corners of the faceplate
into place on the frame. If connected properly, the faceplate should hold itself in
place against the frame.
9. Press the bottom corners of the faceplate until each corner snaps into place with
the frame.
Cone and Diffuser
Acetate Button Label
Use screws to
secure mounting
bracket to the
back box
Hook top of frame onto the lips
of the mounting bracket
Metal clips from mounting bracket

© 2015 Harman. All rights reserved. NetLinx, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered trademarks of
HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-2102-08 REV: D
Last Revised: 7/10/2015
Getting Connected
FIG. 5 displays the rear panel of the MCP-108 featuring all available connectors for the
ControlPad.
FIG. 5 MCP-108 REAR PANEL
The following sections provide information about each connector on the ControlPad.
RS-232 Port
The MCP-108 features two 3-pin RS-232 300-115,200 baud connector ports so you
can connect a serial device to the ControlPad.
NOTE: Massio ControlPads do not support RS-422 or RS-485 communications to other
devices.
IR/Serial Port
The MCP-108 features two IR connectors for connecting two IR-controllable devices to
the ControlPad.
RELAY Ports
You can connect up to two independent external relay devices to the Relay connectors
on the ControlPad.
I/O Port
The ControlPad features an I/O connector so you can connect one input/output device
to the ControlPad. The PWR pin provides +12 VDC @ 200 mA and is designed as a
power output for the PCS Power Current Sensors, VSS2 Video Sync Sensors (or
equivalent). The GND connector is a common ground and is shared by all I/O ports. A
common ground is shared with I/O ports 1 - 2.
CAUTION: Improper wiring could damage your ControlPad. The CP-3008 ControlPad has
the ground and power signals in swapped positions on the I/O port. If you are replacing a
CP-3008 ControlPad with the MCP-108, you may need to make a wiring change in your I/
O connector to avoid damaging the MCP-108.
Conf iguration
You can configure the ControlPad by using Rapid Project Maker (RPM). To configure the
ControlPad, you must have it powered by PoE and you must know its IP address.
Locating the IP Address of the ControlPad
You can locate the IP address of the ControlPad by using RPMLoader, and performing
the following steps to listen for the device:
1. Open RPMLoader and click Communications Settings to open the
Communications Settings dialog.
2. Under Connection to Master, select Network Connection.
3. Click Search For Masters to search the network for online Masters in the Search
for Masters dialog.
4. Click Start Searching to begin listening for "blink" (UDP) messages from NetLinx
Masters on the subnet.
5. When you see the IP Address for the MCP-108 in the List of Active NetLinx Master
Controllers, click Stop Listening. The IP address of the ControlPad is listed in the
dialog.
Connecting to the ControlPad via USB
If you do not have a DHCP server or if the ControlPad has an unknown static IP address,
you can obtain the IP address of the ControlPad by connecting it to a PC via USB.
NOTE: Ensure the PC you are using to connect to the controller has the latest version of
NetLinx Studio 4.0 installed on it.
1. Using a standard Micro-USB cable, connect the Program Port on the rear panel of
the ControlPad (see FIG. 5) to your PC.
2. In NetLinx Studio, select Settings > Workspace Communications Settings to
open the Workspace Communication Settings dialog.
3. Click System Settings to open the Communication Settings dialog.
4. Select the USB tab. The USB tab features a list of devices connected to your PC
via USB. The IP address of the ControlPad appears in the IPv4 Address column.
5. Highlight your ControlPad and click Select to connect to it.
Toggling Between IP Addressing Modes: DHCP and Static IP
The MCP-108 supports both DHCP and static IP addresses. You can use a static IP
address which you can set via a Telnet command (SET IP), or you can use the factory
default static IP address (192.168.1.3).
The MCP-108 features a pinhole reset pushbutton located on the bottom of the
ControlPad. With the MCP-108 powered and booted up, you can toggle between the
DHCP and Static IP modes by pressing and holding the ID Pushbutton for 10 seconds.
NOTE: You must wait until the ControlPad is finished booting before toggling the IP
address. Pressing the pushbutton while booting will cause the ControlPad to restore its
factory default settings.
When you release the Pushbutton, the ControlPad toggles either from static to dynamic
(DHCP) IP addressing or vice versa. The ControlPad automatically reboots to complete
the process.
In place of using the ID pushbutton, you can press buttons 1 and 2 simultaneously on
the ControlPad to simulate the functions of the ID pushbutton. You must keep both
buttons pressed for 10 seconds as you would with the ID pushbutton to toggle between
IP address modes.
FIG. 6 PRESS BUTTONS MARKED WITH X TO SIMULATE ID PUSHBUTTON FUNCTIONS
SERIAL PORT WIRING
ControlPad Port Connect to Serial Device
GND GND
RX TX
TX RX
I/O PORT WIRING
SPECIFICATIONS
Signal Function
GND: Signal GND
1: Output
2: Output
+12 V: PWR
IR/Serial
port
I/O port
Relay
port
Program
port
LAN
RS-232
ports
X
X
Other AMX Control System manuals
Popular Control System manuals by other brands

DEEP SEA ELECTRONICS
DEEP SEA ELECTRONICS DSE8610 MKII Operator's manual

Tekmar
Tekmar 150 Data brochure

D.Electron
D.Electron CNC Z32 Florenz Series Programming guide

Techsys
Techsys eMiniFlush Setup instructions

Mitsubishi Electric
Mitsubishi Electric MCCH1 installation manual

Crestron
Crestron 4 Series quick start guide