AXCENT3 INTEGRATED AXCESS
CONTROLLER
AXCENT3 PRO INTEGRATED AXCESS
CONTROLFRAME
Provides versatile, multiport control:
• 6 data ports for RS-232/422/485 control,
with XON/XOFF and CTS/RTS,
user-definable baud rates (300, 600,
1200, 2400, 4800, 9600, 19200, 38400).
• 6 IR/Serial ports for control of up to 1.14
MHz and 1-way data, user-definable
baud rates (300, 600, 1200, 2400, 4800,
9600, 19200, 38400).
•6-channel I/O port for closure, 0-5 VDC
voltage sensing, or interactive power
sensing for IR ports
•8-channel Relay port
OTHER FEATURES
•Converts from Master (default) to Server
operation, allowing the use of multiple
units in the same system
•Supports graphical setup, status, and
testing through the use of AMX
OpenAxcess software
•Allows PC-based local or modem setup,
status, and testing with optional
Windows or Terminal Emulator software
•Includes status LEDs for AXlink bus
operation, RS-232, Relay, IR/Serial, and
I/O control activity
•The Axcent3 PRO accepts up to four
slide-in Axcess Control Cards
POWER CONSUMPTION
•Axcent3: 500 mA @ 12 VDC
•Axcent3 PRO: 550 mA @ 12 VDC
DIMENSIONS (HWD)
•Axcent3: 3.47" x 17.00" x 3.00"
(8.81 cm x 43.18 cm x 7.62 cm)
•Axcent3 PRO: 3.47" x 17.00" x 13.65
(8.81 cm x 43.18 cm x 34.68 cm)
WEIGHT
•Axcent3: 2.5 lbs. (1.1 kg)
•Axcent3 PRO: 5.6 lbs. (2.6 kg) without
Axcess Control Cards
FRONT PANEL
PROGRAM port:
•DB-9 (male) connector for system
programming
Status indicators:
•32 (red) LEDs showing port activity
•RS-232/422/485 - 6 receive LEDS and 6
transmit LEDs
•Relay - 8 LEDs
•IR/Serial/Data - 6 LEDs
•I/O - 6 LEDs
Axlink indicator:
•Green LED shows AXlink data activity.
Slots 1-4:
•4Axcess Controls Cards (only available
on the Axcent3 PRO)
RS-232 RANGE
•50’ (15.24 m) max
ENCLOSURE
•Metal with black matte finish
REAR PANEL
RS-232/RS-422/RS-485 ports:
•Six 9-pin (male) D-Sub, RS-232/422/485
XON/XOFF, CTS/RTS, 300, 200 baud
Status indicators
•32 (red) LEDs show activity on the RS-
232/422/485, Relay, IR/Serial/Data, and
I/O ports
•The LEDs light when data activity occurs
on the respective ports
AXlink/PWR connector:
•Four-pin connector for AXlink data and
power and a two-pin connector for
external 12 VDC power supply
Relay connectors 1-8:
•Two 8-pin connectors, 750 mA, 28
VAC/24 VDC (normally open)
IR/Serial/Data connectors 1-6:
•12-pin connector (six 2-pin jacks), IR, IR
Serial or one-way data communication
(0-5 VDC levels only)
Input/Output connectors:
•8-pin connector, I/O 1-6, Common, +12
VDC power tap 200 mA, contact closure
or TTL logic inputs
PROGRAM port:
•DB-9 (male) connector for system
programming and diagnostics
Slots 1-4::((oonnllyyaavvaaiillaabblleeoonnAAxxcceenntt33PPRROO))
• Four 16-pin connectors for Axcess
Controls Cards
INCLUDES
• 4 CC-IRC emitters
• Metal tab strip for commoning relays
• Rack-mount brackets
OPTIONAL ACCESSORIES
• 12 VDC power supply (uses PS2.8 but
can use PSN6.5)
• CSB Cable Support Bracket
• AC-RK3 Rack Kit
• Axcess Control Cards
((AAxxcceenntt33PPRROOoonnllyy))
axcent3 and axcent3 pro integrated controllers
ARGENTINA • AUSTRALIA • BELGIUM • BRAZIL • CANADA • CHINA • ENGLAND • FRANCE • GERMANY • GREECE • HONG KONG • INDIA • INDONESIA • ITALY • JAPAN
LEBANON • MALAYSIA • MEXICO • NETHERLANDS • NEW ZEALAND • PHILIPPINES • PORTUGAL • RUSSIA • SINGAPORE • SPAIN • SWITZERLAND • THAILAND • TURKEY • USA
ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • 469.624.8000 • +1.469.624.7400 • 469.624.7153 fax • www.amx.com
©2006 AMX. All rights reserved. AMX and the AMX logo are all trademarks of AMX. AMX reserves the right to alter specifications without notice at any time.
17.0
(431.8MM)
17.0
(431.8MM)
3.47
(88.1MM)
3.47
(88.1MM)