AND UA-851THW Manual

Wireless Automatic
Blood Pressure Monitor
Multilingual Instruction Guide - Model UA-851THW
English • Français • Español

Please read this important information before using your monitor.
☞
Please remember that only a medical practitioner is qualified to interpret your
blood pressure measurements. Use of this device should not replace regular medical
examinations.
☞
Consult your physician if you have any doubt about your readings. Should a mechanical
problem occur, contact LifeSource
®
at 1-888-726-9966.
☞
Do not attempt to service, calibrate, or repair this monitor.
☞
Because your UA-851THW monitor contains delicate, high-precision parts, avoid
exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust.
LifeSource
®
guarantees the accuracy of this monitor only when it is stored and used
within the temperature and humidity ranges noted on page E-18.
☞
Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with water and
a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean
monitor or cuff.
☞
Remove and replace batteries if monitor is not used for more than six months. Alkaline
batteries recommended.
☞
Place the UA-851THW where it is not exposed to external noises and strong
electromagnetic waves.
☞
Place the UA-851THW where the radio signal between the blood pressure monitor and
ActiLink™ won’t be significantly impeded by metal or walls.
PRECAUTIONS
The UA-851THW is designed to be used at home, by those who are twelve (12) years and
older, to monitor blood pressure (systolic and diastolic) and pulse rate.
IMPORTANT INFORMATION✓
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS
DANGER - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
CAREFULLY FOLLOW THESE INSTRUCTIONS.
☞
For connection to a power supply not in the U.S.A., use an attachment plug adapter of
the proper configuration for the power outlet.
☞
The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor
mount position.

LifeSource - Wellness Connected.™
Congratulations on purchasing a state-of-the-art LifeSource
UA-851THW Blood Pressure Monitor—one of the most
technologically advanced blood pressure monitors available today. As
part of the Wellness Connected family of products, the UA-851THW
works seamlessly with LifeSource’s other wireless and wired Wellness
Connected products. Designed for ease of use and accuracy, the
UA-851THW will effortlessly integrate activity into your daily
wellness regimen.
Physicians agree that daily self-monitoring is an important step
individuals can take to maintain overall health. The Wellness
Connected family provides a complete system for conveniently
tracking vital health information. Use a Wireless Precision Scale
with your new UA-851THW Blood Pressure Monitor, or pair it
with a Wireless Activity Monitor, or both!
A&D Medical has been manufacturing high quality healthcare and
wellness products for over 20 years. We are committed to providing
you and your family with monitoring devices that provide the
utmost in accuracy and convenience.
LifeSource - Designed for Life.

E-1
LifeSource Health Line (Toll-Free): 1-888-726-9966
TABLE OF CONTENTS
?WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . . . . . . . . .E2
MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E3
GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E4
INSTALLING THE BATTERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E4
SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . . . . . . . . . . . . .E5
ATTACHING THE CUFF TO THE MONITOR. . . . . . . . . . . . . . . . . . . . . . .E6
TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . .E6
HOW THE UA851THW WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E8
ABOUT CUFF INFLATION METER . . . . . . . . . . . . . . . . . . . . . . . . . . . .E8
WHAT IS AN IRREGULAR HEARTBEAT?. . . . . . . . . . . . . . . . . . . . . . . . .E9
ABOUT PRESSURE RATING INDICATOR™ . . . . . . . . . . . . . . . . . . . . . . .E9
USING THE OPTIONAL AC ADAPTER. . . . . . . . . . . . . . . . . . . . . . . . . E11
ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E12
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E17
SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E18
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E19
INSTRUCCIONES EN ESPAÑOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S1
INSTRUCCIONES EN FRANÇAIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F1

E-2 LifeSource Health Line (Toll-Free): 1-888-726-9966
WHAT DISPLAY SYMBOLS MEAN
?
?
Display/
Symbol
Measurement is in progress,
remain as still as possible.
Take measurement again and
consult with your physician.
Replace all batteries with new
ones when the symbol blinks.
Alkaline batteries recommended.
Try the measurement again.
Remain very still during the
measurement.
Fasten the cuff correctly, and try
the measurement again.
Check for air leaks along the
tube and around the air socket.
Refasten the cuff and retake
measurement.
Make sure tube is properly
connected to cuff and monitor.
Try the measurement again.
Remain very still during the
measurement.
Measurement is in progress,
remain as still as possible.
Refer to the section “About
Pressure Rating Indicator” for
further explanation.
The symbol shown while measure-
ment is in progress. It blinks while
detecting the pulse.
An irregular heartbeat or body
movement may have occurred.
Refer to page E-8 for more infor-
mation on irregular heartbeats.
The battery power indicator is
displayed during measurement.
The batteries are low when it
blinks.
Unstable blood pressure due to
excessive body movement.
The systolic and diastolic values are
within 10 mmHg of each other.
The pressure value did not increase
during inflation.
The cuff is not fastened correctly.
There is an air leak in the cuff or
monitor.
The pulse is not detected correctly.
Cuff Inflation Meter
Pressure Rating Indicator™
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
Battery Full
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
Battery Low
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
PULSE DISPLAY ERROR
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
Condition/Cause Recommended
Action

E-3
LifeSource Health Line (Toll-Free): 1-888-726-9966
UA -851THW DIGITAL BLOOD PRESSURE MONITOR
MONITOR COMPONENTS
Display
ActiLink USB Transceiver
(not to scale)
START Button
Air Socket
Air Connector Plug
Air Hose
Arm Cuff
Battery Compartment Battery Cover
FRONT
AC Adapter Jack Optional AC
Adapter
BACK
Serial No. Label
S/N ABCD-00123-12345
ActiLink Serial No. Label
S/N ABCD-00123-12345

E-4 LifeSource Health Line (Toll-Free): 1-888-726-9966
You must install 4 type AA (1.5 volt) batteries (included), or use the optional AC
Adapter (see page E-11 for instruction on using the monitor with the optional AC
adapter) and attach the cuff to the monitor before using it. To install batteries (or
replace them if the “Low Battery” symbol appears on display), proceed as follows:
1. Remove battery compartment cover by gently pushing down on arrow and sliding
cover forward.
2. Put in bottom row of batteries first. Place the batteries in
compartment with positive (+) and negative (–) terminals
matching those indicated in the compartment. Be sure
batteries make contact with compartment terminals.
3. Replace cover by sliding it into the compartment and
gently pressing into place.
NOTE: Rechargeable batteries will not work with this monitor.
Follow these instructions to get started using your new wireless UA-851THW Blood
Pressure Monitor. (Note: if you already use another Wellness Connected family device,
please skip this section and simply add your new UA-851THW device in the Devices
tab of your Wellness Connected software in the account section or your ActiHealth
account.)
Setting up Wellness Connected on your personal computer:
(a) Go to the following Internet web address:
http://www.LifeSourceOnline.com/getstarted
(b) Download the Wellness Connected Tracking Software and follow the
instructions to install the software.
(c) Run the software and complete the walkthrough set-up and registration process.
GETTING STARTED
?
INSTALLING THE BATTERIES
?!
Step 1
Step 2
Step 3

E-5
LifeSource Health Line (Toll-Free): 1-888-726-9966
Using the correct cuff size is important for an accurate reading. A cuff that is too large will
produce a reading that is lower than the correct blood pressure; a cuff that is too small will
produce a reading that is higher than the correct blood pressure. With your arm hanging
at the side of your body, measure the circumference of your upper arm at the midpoint
between the shoulder and elbow.
!
SELECTING THE CORRECT CUFF SIZE
ARM SIZE RECOMMENDED CUFF
SIZE REPLACEMENT CUFF MODEL #
9.4" - 14.2" (24 - 36cm) Medium Cuff UA-280
14.2" - 17.7" (36-45cm) Large Cuff UA-281
NOTE: The LifeSource small cuff is not compatible with the UA-851THW
monitor.
USE SMALL CUFF USE LARGE CUFFPROPER FIT RANGE
INDEX
Cuff Size Indicator On The Cuff
Our cuff has an indicator which tells you whether you are using the correct cuff size or
not. Place the cuff on your arm (see Page E-6 to learn how to put the cuff on correctly)
and if the Index Mark points within the Proper Fit Range, you are using the
correct cuff size. If the Index points outside of the Proper Fit Range, contact A&D
Medical at 1-888-726-9966 (in Canada, call Auto Control Medical at 1-800-461-
0991) for more information on where to obtain a cuff replacement.
NOTE: If the cuff size indicator falls on a borderline between two size categories,
pick either one and make sure to use the same cuff size for each measurement.

E-6 LifeSource Health Line (Toll-Free): 1-888-726-9966
Tips for Blood Pressure Monitoring:
☞
Relax for about 5 minutes before measurement.
☞
Do not smoke or ingest caffeine at least 30 minutes prior to measurement.
☞
Remove constricting clothing and place cuff on bare arm.
☞
Unless your physician recommends otherwise, use left arm
to measure pressure.
☞
Do not talk during measurement.
☞
Do not cross legs and keep your feet flat on floor during measurement.
Now you are ready. Follow these simple steps:
1. Sit comfortably with your left arm resting on a flat
surface so that the center of your upper arm is at the
same height as your heart.
After installing the batteries, you
must attach the blood pressure cuff to
the monitor. To do so, insert the Air
Connector Plug of the blood pressure
cuff into the Air Socket of the monitor
firmly.
NOTE: Be sure to differentiate the
Air Socket from the AC Adapter Jack.
The Air Connector Plug will only
securely fit into the correct jack.
ATTACHING THE CUFF TO THE MONITOR
TAKING YOUR BLOOD PRESSURE

E-7
LifeSource Health Line (Toll-Free): 1-888-726-9966
3. Secure cuff around arm. The cuff should be snug but
not too tight. You should be able to insert two fingers
between the cuff and your arm.
2. Lay left arm on the table, palm up and thread cuff end
through metal loop, smooth side against arm. Then
position the tube off-center toward the inner side of arm
in line with your little finger.
TAKING YOUR BLOOD PRESSURE
4. Confirm that the Index Mark points within the
proper fit range.
5. Press the START button. As the cuff pressurizes,
measurement will begin and the Cuff Inflation Meter will show on the display
screen. It is normal for the cuff to feel very tight.
Note: If an appropriate pressure is not obtained, the device automatically starts
to inflate again.
Note: If you wish to stop inflation at any time, press the START button again.
6. When the measurement is complete, the systolic and diastolic pressure readings
and pulse rate are displayed. The cuff deflates and the monitor automatically shuts
off after 60 seconds, or you can turn it off by pressing the START button. Your
measurement is automatically stored in memory (the monitor can store up to 51
readings in memory).
7. The monitor automatically transmits your readings wirelessly if it is within range
of an active ActiLink USB Transceiver. If the monitor is not in range, the data will
be stored in memory until the blood pressure monitor is activated in range of an
active ActiLink.
IMPORTANT: Measure blood pressure at the same time each day.
IMPORTANT: The ActiLink USB Transceiver will not work when plugged into a
computer in sleep, suspend, or hibernation mode.
IMPORTANT: The range of the UA-851THW may be affected by walls, materials
around or between the UA-851THW and ActiLink, and other environmental factors.

E-8 LifeSource Health Line (Toll-Free): 1-888-726-9966
WHAT IS AN IRREGULAR HEARTBEAT?
ABOUT CUFF INFLATION METER
The Cuff Inflation Meter is located on the left side of the display screen to tell you
when the blood pressure monitor is inflating and deflating the cuff. The Cuff Inflation
Meter moves up during inflation and moves down during deflation.
Inflation in Progress Inflation Complete Deflation/Measurement in
Progress
LifeSource
®
blood pressure monitors are easy to use, accurate and digitally display full
measurement readouts. Our technology is based on the “oscillometric method” – a
noninvasive blood pressure determination. The term “oscillation” refers to any measure
of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure
generated by the arterial wall as it expands and contracts against the cuff with each
heartbeat.
The cuff is inflated until the artery is fully blocked. The inflation speed is maximized
and the pressure level is optimized by the device. The monitor takes measurements
while the cuff is both inflating and deflating. This results in a faster measurement
providing greater comfort to the user.
IMPORTANT NOTE: The ActiLink USB Transceiver will not work when plugged into a
computer in sleep, suspend, or hibernation mode
IMPORTANT NOTE: The range of the UA-851THW may be affected by walls, materials
around or between the UA-851THW and ActiLink, and other environmental factors.
HOW THE UA851THW WORKS

E-9
LifeSource Health Line (Toll-Free): 1-888-726-9966
WHAT IS AN IRREGULAR HEARTBEAT?
The UA-851THW Blood Pressure Monitor provides a blood pressure and pulse rate
measurement even when an irregular heartbeat occurs. The Irregular Heartbeat symbol
will appear in the display window in the event an Irregular Heartbeat has
occurred during measurement. An irregular heartbeat is defined as a heartbeat that
varies by 25% from the average of all heartbeat intervals during the blood pressure
measurement. It is important that you relax, remain still and refrain from talking
during measurements.
NOTE: We recommend contacting your physician if you see this
symbol frequently.
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
The Pressure Rating Indicator™ is a feature which provides
a snapshot of your blood pressure classification based on
your measurements. This will let you quickly know what
your blood pressure readings mean. Each segment of the bar
indicator corresponds to the Seventh Report of the Joint
National Committee (JNC7) on Prevention, Evaluation and
Treatment of High Blood Pressure from the National Heart,
Lung and Blood Institute - May 2003. For a more detailed
look at this blood pressure classification, please refer to
“Assessing High Blood Pressure for Adults” on page E-13.
:The indicator displays a segment, based on the current measurement,
corresponding to the JNC7 Classification.
NOTE: Due to other risk factors (e.g. diabetes, obesity, smoking, etc.) in
addition to your blood pressure measurement, the Pressure Rating Indicator
is approximate. Please consult with your physician for interpretation and
diagnosis of your blood pressure measurements.
Hypertension Stage 2
Hypertension Stage 2
Hypertension Stage 1
Prehypertension
Prehypertension
Normal
Stage 2 Hypertension
Stage 1 Hypertension
Prehypertension
Normal
Example
Hypertension
Stage 2
Example
Stage 2
Hypertension
Hypertension Stage 2
Hypertension Stage 2
Hypertension Stage 1
Prehypertension
Prehypertension
Normal
Stage 2 Hypertension
Stage 1 Hypertension
Prehypertension
Normal
Example
Hypertension
Stage 2
Example
Stage 2
Hypertension
ABOUT PRESSURE RATING INDICATOR™

E-10 LifeSource Health Line (Toll-Free): 1-888-726-9966
Free Trial Offer ActiHealth online service
ActiHealth is an online service that can automatically
upload and record data collected by your Wellness
Connected devices. Access your wellness information
anytime, anywhere on your personalized wellness
dashboard on ActiHealth! Stay motivated and on
track by joining communities, setting challenges,
sharing data online with friends, family, support
groups and more. Try it free for 30 days!
The Wellness Connected Software must
be downloaded and installed on your
home computer to take full advantage of
the UA-851THW’s wireless capabilities
and advanced features. If you have not
done so already, go to http://www.
LifeSourceOnline.com/getstarted to begin
the installation process.
Software Features
• Each measurement you take is
automatically sent to your computer and charted for your review.
• Review averages and compare morning and evening measurements. See clear
indications as to where your results fall versus JNC7 classifications.
WELLNESS CONNECTED SOFTWARE FEATURES
ACTIHEALTH™ ONLINE SERVICE
To learn more and begin your 30-day free trial offer,
please see the card included in your UA-851THW
Blood Pressure Monitor box or go to http://actihealth.
com/lifesource. This is a limited-time offer, so act now!

E-11
LifeSource Health Line (Toll-Free): 1-888-726-9966
USING THE OPTIONAL AC ADAPTER
The UA-851THW has an AC adapter jack to allow you to supply power from an
outlet in your home. We recommend you use only the optional LifeSource AC adapter
to avoid potential damage to the monitor. To purchase the optional AC Adapter,
please contact our LifeSource Health Line at 1-888-726-9966.
Connecting the AC adapter to the monitor:
1. Gently insert the AC adapter plug into a 120V AC outlet.
2. Connect the AC adapter plug into the jack on the back of the monitor.
Disconnecting the AC adapter from the monitor:
1. Turn the unit off by pressing the START button.
2. Disconnect the plug from the jack.
3. Gently remove the AC adapter from the outlet.
AC Adapter
Plug
Jack

E-12 LifeSource Health Line (Toll-Free): 1-888-726-9966
What Is Blood Pressure?
Blood pressure is the force exerted by blood against the walls of the arteries. Systolic
pressure occurs when the heart contracts; diastolic pressure occurs when the heart
expands. Blood pressure is measured in millimeters of mercury (mmHg).
What Affects Blood Pressure?
Blood pressure is affected by many factors: age, weight, time of day, activity level,
climate, altitude and season. Certain activities can significantly alter one’s blood
pressure. Walking can raise systolic pressure by 12 mmHg and diastolic pressure by 5.5
mmHg. Sleeping can decrease systolic blood pressure by as much as 10 mmHg.
In addition to these factors, beverages containing caffeine or alcohol, certain
medications, emotional stress and even tight-fitting clothes can make a difference in
the readings.
What Causes Variations In Blood Pressure?
An individual’s blood pressure varies greatly from day to day and season to season.
For hypersensitive individuals, these variations are even more pronounced. Normally,
blood pressure rises during work or play and falls to its lowest levels during sleep.
ABOUT BLOOD PRESSURE

E-13
LifeSource Health Line (Toll-Free): 1-888-726-9966
Assessing High Blood Pressure for Adults
The following standards for assessing high blood pressure (without regard to age or
gender) have been established as a guideline. Please note that other risk factors (e.g.
diabetes, obesity, smoking, etc.) need to be taken into consideration and may affect these
figures. Consult with your physician for an accurate assessment.
JNC7 Classification Table – for adults within the U.S.
ABOUT BLOOD PRESSURE
BP Classification Systolic (mmHg) Diastolic (mmHg)
Normal < 120 and < 80
Prehypertension 120-139 or 80-89
Stage 1 Hypertension 140-159 or 90-99
Stage 2 Hypertension
≥ 160
or
≥ 100
SOURCE: The Seventh Report of the Joint National Committee on
Prevention, Evaluation and Treatment of High Blood Pressure for Adults.
National Heart, Lung and Blood Institute - May 2003.
WHO Classification Table - for adults outside of the U.S. (e.g. Canada, Mexico)
BP Classification Systolic (mmHg) Diastolic (mmHg)
Optimal < 120 and < 80
Normal < 130 or < 85
High-Normal 130-139 or 85-89
Stage 1 Hypertension 140-159 or 90-99
Stage 2 Hypertension 160-179 or 100-109
Stage 3 Hypertension
≥ 180
or
≥ 110
SOURCE: Standards to assess high blood pressure, without regard to age or
gender, have been established by the World Health Organization (WHO).

E-14 LifeSource Health Line (Toll-Free): 1-888-726-9966
What Is Hypertension?
Hypertension (high blood pressure) is the diagnosis given when readings consistently
rise above normal. It is well known that hypertension can lead to stroke, heart attack
or other illness if left untreated. Referred to as a “silent killer” because it does not
always produce symptoms that alert you to the problem, hypertension is treatable
when diagnosed early.
Can Hypertension Be Controlled?
In many individuals, hypertension can be controlled by altering lifestyle and
minimizing stress, and by appropriate medication prescribed and monitored by
your doctor. The American Heart Association recommends the following lifestyle
suggestions to prevent or control hypertension:
Don’t smoke Have regular physical checkups
Reduce salt and fat intake Maintain proper weight
Monitor your blood Exercise routinely
pressure at periodic intervals
Why Measure Blood Pressure at Home?
It is now well known that, for many individuals, blood pressure readings taken in a
doctor’s office or hospital setting might be elevated as a result of apprehension and
anxiety. This response is commonly called “white coat hypertension.” In any case,
self-measurement at home supplements your doctor’s readings and provides a more
accurate, complete blood pressure history. In addition, clinical studies have shown that
the detection and treatment of hypertension is improved when patients both consult
their physicians and monitor their own blood pressure at home.
ABOUT BLOOD PRESSURE

E-15
LifeSource Health Line (Toll-Free): 1-888-726-9966
ABOUT BLOOD PRESSURE
Answers to Why Your Readings Are Different Between Home and
at the Doctor’s Office
Why are my readings different between home and at a doctor’s office?
Your blood pressure readings taken in a doctor’s office or hospital setting may be
elevated as a result of apprehension and anxiety. This response is known as white coat
hypertension.
When I bring my monitor to a doctor’s office, why do I get a different
measurement from my monitor to that taken by a doctor or nurse?
The healthcare professional may be using a different sized cuff. The size of the bladder
inside the cuff is critical for the accuracy of the measurement. This may give you a different
reading. A cuff too large will produce a reading that is lower than the correct blood pressure;
a cuff that is too small will produce a reading that is higher than the correct blood pressure.
There may also be other factors that can cause the difference in measurements.
Keys to Successful Monitoring:
Blood pressure fluctuates throughout the day. We recommend that you are consistent
in your daily measurement routine:
• Measure at the same time every day.
• Sit in the same chair/position.
• Do not cross legs and keep your feet flat on the floor.
• Relax for 5 minutes before measurement.
• Use the correct cuff size to get an accurate reading.
• Sit still during measurement – no talking, eating or sudden
movements.

E-16 LifeSource Health Line (Toll-Free): 1-888-726-9966
Establishing Baseline Measurements
The most important method to get an accurate blood pressure measurement is
consistency. To get the most benefit out of your monitor, it is important to establish a
“baseline measurement.” This helps build a foundation of measurements that you can
use to compare against future readings. To build this baseline measurement, devote
two weeks for consistent blood pressure monitoring. This involves doing everything
the same way when you measure (e.g. measuring during the same time of day, in the
same location, sitting in the same chair, using the same cuff, etc.). Once you establish
your baseline measurement, you can start evaluating if your measurement has been
affected by factors such as lifestyle changes or medication treatment.
How Do I Record My Blood Pressure?
Blood pressure readings are typically recorded with the systolic pressure written first,
followed by a slash mark and the diastolic pressure. For example, 120 mmHg systolic
and 80 mmHg diastolic measurements are written as 120/80. Pulse is simply written
with the letter “P” followed by the pulse rate—P 72, for example.
Each measurement you take is automatically sent to your computer and charted
instantly. The Wellness Connected software will direct all of the measurements from
a device to the account the device is registered to. If the device is not registered,
measurements will not be off loaded. If you choose, you may sign up for an
ActiHealth internet account and send your measurement data there. Data sent to
ActiHealth will not be available on your Wellness Connected account.
ABOUT BLOOD PRESSURE

E-17
LifeSource Health Line (Toll-Free): 1-888-726-9966
TROUBLESHOOTING
NOTE: If the actions described above do not solve the problem, call 1-888-726-
9966. Do not attempt to repair the device yourself.
Nothing appears in the
display, after I press the
START button.
The cuff does not
inflate.
The unit does not
measure. Readings are
too high or too low.
The value is different
from that measured
at a clinic or doctor’s
office.
Batteries are drained.
Battery terminals are not in the
correct position.
Battery voltage is too low. Low
battery symbol blinks. [If the
batteries are drained completely,
the mark does not appear.]
The cuff is not fastened prop-
erly.
You moved your arm or body
during the measurement.
The cuff position is not correct.
You are using the wrong size
cuff.
The healthcare professional may
be using a different sized cuff.
Your measurements may be
elevated by white coat hyper-
tension
Replace all batteries with new
ones. Alkaline batteries recom-
mended.
Reinstall the batteries with nega-
tive and positive terminals match-
ing those indicated in the battery
compartment.
Replace all batteries with new
ones. Alkaline batteries recom-
mended.
Fasten the cuff correctly.
Make sure you remain very still
and quiet during the measurement.
Sit comfortably and still. Make
sure the cuff is at the same level as
your heart.
See Pg. E-5 "Selecting the Correct
Cuff."
See Pg. E-15 "Answers to Why
Your Readings Are Different
Between Home and at the
Doctor’s Office."
See Pg. E-14 "Why Measure
Blood Pressure at Home?"
Problem Probable Cause Corrective Action
ActiLink/computer
software is not receiving
new measurements
• Is your computer on and your ActiLink plugged in?
• Move the blood pressure monitor closer to the ActiLink with a
clear line-of-sight and take a measurement.
• Replace all batteries with new ones
Table of contents
Other AND Blood Pressure Monitor manuals