manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Andrew Alliance
  6. •
  7. Laboratory Equipment
  8. •
  9. Andrew Alliance Andrew+ User manual

Andrew Alliance Andrew+ User manual

Other Andrew Alliance Laboratory Equipment manuals

Andrew Alliance Waters Shaker+ User manual

Andrew Alliance

Andrew Alliance Waters Shaker+ User manual

Andrew Alliance Waters Vacuum+ User manual

Andrew Alliance

Andrew Alliance Waters Vacuum+ User manual

Andrew Alliance Waters Andrew+ User manual

Andrew Alliance

Andrew Alliance Waters Andrew+ User manual

Popular Laboratory Equipment manuals by other brands

Radleys Carousel 6 Plus instructions

Radleys

Radleys Carousel 6 Plus instructions

Hemotherm 400MR Operation & technical manual

Hemotherm

Hemotherm 400MR Operation & technical manual

mrclab DVO Series Operation manual

mrclab

mrclab DVO Series Operation manual

CoolLED pE-800 quick start guide

CoolLED

CoolLED pE-800 quick start guide

Luminex Guava easyCyte Maintenance Guide

Luminex

Luminex Guava easyCyte Maintenance Guide

IKA A10 basic operating instructions

IKA

IKA A10 basic operating instructions

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Belden

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Koehler K1223 Series Operation and instruction manual

Koehler

Koehler K1223 Series Operation and instruction manual

Globe Scientific GCM-12 quick start guide

Globe Scientific

Globe Scientific GCM-12 quick start guide

Getinge 86 SERIES Technical manual

Getinge

Getinge 86 SERIES Technical manual

CORNING Everon 6000 user manual

CORNING

CORNING Everon 6000 user manual

Biocomp GRADIENT MASTER 108 operating manual

Biocomp

Biocomp GRADIENT MASTER 108 operating manual

Cole Parmer Stuart SB3/1 instruction manual

Cole Parmer

Cole Parmer Stuart SB3/1 instruction manual

BEVS 2501/2A user manual

BEVS

BEVS 2501/2A user manual

Qiagen DML 3000 user manual

Qiagen

Qiagen DML 3000 user manual

Queensgate NANOSCAN OP400 Quick start instructions

Queensgate

Queensgate NANOSCAN OP400 Quick start instructions

Parr Instrument 4560 Operating instructions manual

Parr Instrument

Parr Instrument 4560 Operating instructions manual

Integra DOSE IT operating instructions

Integra

Integra DOSE IT operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

QUICK START GUIDE
Andrew+
Before you begin
If you do not have a OneLab account,
please create one by going to:
onelab.andrewalliance.com/signup
Unpacking Andrew+
Deploy the robotic arm Remove the interme-
diate foam block
Deploy the tool stand...
Remove the two
mid-adaptors
Place your Andrew+ on a steady table.
For moving the device, incline it gently
backward by pushing onto its nose in order
to grab the grip under the baseplate,
then lift Andrew+ and move.
until you hear a clicking
sound...
Plug the provided adap-
ter to a power source,
then plug it to Andrew+
(located in the back of
the baseplate)
and then an other one
Grab Andrew+ by the
back of head and by the
grip that you will nd
below the baseplate
Remove power supply,
manuals, waste domino,
and cables then remove
the top foam-based
protection
Put intermediate and
top foam back in the
cardboard. Close it.
Please store if for main-
tenance need.
Now please
connect Andrew+
to OneLab
please refer to the
next page
“Getting started”
Remove the plastic
sheeting of the hand
Connect the Waste
Domino by sliding it
inside the connec-
tor located in the
baseplate
Expand the silicone
waste and place
it into the waste
Domino
Place them in any available slot
of the tool stand
Equip each Andrew Alliance
electronic pipette with a pipette
adaptor
Now your Andrew+ is set up.
click
click
Keep your back straight
and use your legs to lift
Andrew+
Caution:
Andrew+ weights
16 kg / 35,3 lbs
!
DO NOT grab
Andrew+ from
its arms, doing so will
cause irreversible
damage to the unit
!
Open the
cardboard
gently
Getting started
Plug your Andrew+
to a power source.
Wait the LED sign to turn blue
and blink
After a couple of minutes, Andrew+
will inform you when it is in
installation mode.
Connect your computer, tablet or smartphone to Andrew+
Launch a web browser, type http://192.168.2.1
and follow the on-screen steps to continue installation.
A. Go to your Wi-Fi settings
and select the network named Andrew-718.xxxx.xxxxx
1 2
3
4
scan me
Please take note that
the installation page
might open automatically.
If you do not have access to
a Wi-Fi compatible device,
please refer to our online help:
help.andrewalliance.com
!
!
xxxx.xxxxx is the Andrew+ device serial number
(you can nd it on the door of the Optical Location Module, see “Product
overview” part)
B. The LED sign will stop blinking when it’s successfully connected.
If Andrew+ doesn’t enter auto-
matically in installation mode,
press 5 times the push button.
!
http://192.168.2.1
Feel free to contact
the Andrew Alliance support team
Call us
+41 22 518 0357
Send us an email to
[email protected]
Chat with our support team
directly in OneLab
Mon-Fri: 8:00 - 17:00 CETWe reply within 1 business day
Operations
Design your protocol
Execute experiment with
Andrew+
You can new return to science work
and monitor the experiment whenever you want
Select the Andrew+ as experiment setup
then prepare all the required materials.
Our drag-n-drop editor makes it easy to
design a precise and complete protocol
with all that you need to run your
experiment perfectly.
Andrew+ will follow the experi-
ment as you designed and notify
you when he needs something.
Each step of the experiment will be
reported and available in OneLab.
Product overview
Technical data
Andrew Alliance S.A.
Chemin Grenet 21
1214 Vernier (Geneve) Switzerland
Phone: +41 22 518 0357
[email protected]
Warranty 1 year
Power requirement Voltage range 90~264 VAC, AC current 1.85A/115VAC, 1.0A/230VAC, Frequency
47~63Hz, inrush current (max) 110A/230VAC
Electrical conguration Andrew+ should be connected exclusively with the power supply GSM160B24-R7B
and electrical cable supplied with the instrument
Interfaces • Wi- (2.4 GHz / 5 GHz)
• Ethernet connection (1 Gigabit)
Operating temperature 4°C to 37°C
Imaging system • Hand: High resolution camera equipped with white LED light
• OLM: High resolution camera equipped with low power white LED
and class II red laser (wavelength = 650 nm)
Operating humidity Maximum relative humidity 80% for temperatures up to 37° C.
Safe operating conditions
for the system
• Fluctuation of the supply voltage up to 10% of the rated voltage
• Transient overvoltage
Degree of protection IP20
Required personal computer
characteristics
Tablet or computer equipped with Internet browser and network capability.
Dimensions Dimension with both arms folded: 53.5 cm (H) x 43 cm (W) x 45.5 cm (L)
Weight 16 kg (only the robot)
Audio Integrated audio system (nominal power = 1.5 W)
Additional external power
interfaces
• Connection with docking station (1A @ 24 V)
• 4 tool slots embedded in the tool stand (500mA @ 7.5 V)
Working space Domino self-assembling conguration dynamically set-up on a conventional bench
space, allowing operations on an arbitrary set of Domino from 1 up to 11 elements
compatible with multi-channel pipette - according to available space
and experiment requirements.
Base plate
Hand
Push button
Body
Embedded PC
Domino
connectors
Tool stand
4 tool slots LED sign
Optical
Location
Module
Connector for
Waste Domino