ANEMOI AIRMAX User manual

AIRMAX
Installation Manual
Fecha de edición: March 2020
ANIM01DI Rev. D

AIRMAX
2
UPDATES
DATE
UPDATE
DESCRIPTION
16 / 03 / 2020 D 2020 Products update
Technical documents are regularly updated. Anemoi reserves the right to modify the contents of this manual, in full or in part,
without warning.

AIRMAX
3
TABLE OF CONTENTS
SAFETY .................................................................................................................................................................. 4
1 INTRODUCTION ............................................................................................................................................ 5
2 TECHNICAL CHARACTERISTICS ............................................................................................................... 6
3 DIMENSIONS ................................................................................................................................................. 7
4 DELIVERY ..................................................................................................................................................... 8
4.1 Package Dimensions & Weights ............................................................................................................ 8
4.2 Packing List ........................................................................................................................................... 9
5 MECHANICAL INSTALLATION .................................................................................................................. 10
5.1 Clearances .......................................................................................................................................... 10
5.2 Installation Tools .................................................................................................................................. 11
5.3 Ceiling Mount and Extension rod fixation............................................................................................. 12
5.4 Motor Assembly ................................................................................................................................... 13
5.5 Safety Cable Installation ...................................................................................................................... 14
5.6 Guy Wires Fixation (optional) .............................................................................................................. 15
5.7 Blades Assembly ................................................................................................................................. 16
6 ELECTRICAL INSTALLATION ................................................................................................................... 17
6.1 Conexiones de potencia ...................................................................................................................... 18
6.2 Conexiones de control ......................................................................................................................... 19
6.2.1 Multi Fans Installation ...................................................................................................................... 20
6.2.2 Recommendations .......................................................................................................................... 21
7 MAINTENANCE ........................................................................................................................................... 22

AIRMAX
4
SAFETY
Thank you for purchasing our products!
Please read this manual carefully before use, use the product accordingly and keep the manual in safe place.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards.
Before the installation, read the following warning and caution instructions:
WARNING!
Do NOT install, repair or clean the fan while it is in operation or connected to the power supply. Failure
to do so may result in serious injury or death.
Do NOT install, handle, repair or clean the fan with wet hands. Failure to do so may result in serious injury
or death.
Do NOT use wires with worn or damaged insulation. Doing so may result in serious or fatal electrical shock,
fire or other accidents.
Ensure that the wires are held securely and protected from abrasion, chaffing, overload or other
damage. Risk of serious or fatal electrical shock, fire or other accidents.
Turn Off power to the fan if you detect any damage. Risk of serious or fatal electrical shock, fire or other
accidents.
Do NOT connect a damaged fan to the power supply. Risk of serious or fatal electrical shock, fire or other
accidents.
CAUTION!
Use proper lifting equipment to handle the motor and blade boxes. Otherwise, the fan could be damaged
and there is risk of accident.
Follow the instructions and recommendations contained in this manual carefully. Failure to do so may
result in incorrect installation.

AIRMAX
5
1 INTRODUCTION
The Anemoi AIRMAX is a ceiling fan designed to operate in the harshest ambient conditions due to the certified
IP65 protection. This fan is built in five blades and the drive is integrated in the EC brushless motor.
The main characteristics are:
Aluminium blades with black end caps.
Integrated drive with easy connections.
Modbus RS485 connection for controller.
Strong and robust design and manufacturing with IP65 certification.
In addition, in combination with the traditional air conditioning systems, the use of fans allows generating important
energy savings of up 45% in winter and 25% in summer.

AIRMAX
6
2 TECHNICAL CHARACTERISTICS
AIRMAX 300
AIRMAX 400
AIRMAX 500
AIRMAX 600
AIRMAX 660
GENERAL CHARACTERISTICS
Diameter
3 m
4 m
5 m
6 m
6.6 m
Blades number
5
aluminium
b
lades for aviation, 6061
-
T5
Standard colour
Black matte colour and aluminium blades
MOTOR CHARACTERISTICS
Motor power
1,
0
00W
1,
0
00W
1,
0
00W
1,
0
00W
1,000W
Supply voltage
20
0VAC ~
48
0VAC I
II
, 50/60 Hz
Maximum consumption
970W
1,040W
900W
900W
800W
Maximum consumption (A)
2.6 A
2.5 A
2.3 A
2.2 A
2.2 A
Maximum speed
135
rpm
100
rpm
68
rpm
55r
pm
46rpm
Protection degree
IP
65
IP65
IP65
IP65
IP65
Sound level
56
dBA
54
dBA
50
dBA
50
dBA
49dBA
Total weight
80
kg
91
kg
101
kg
118
kg
123kg
Operating temperature
Motor type
Brushless EC motor
FAN PERFORMANCE
Airflow*
134,130
m3/h
202,248
m3/h
228,800
m3/h
324,901
m3/h
362,337
m3/h
Recommended coverage**
447
m²
674
m²
763
m²
1,083
m²
1,208
m²
Maximum coverage***
626
m²
944
m²
1,068
m²
1,516
m²
1,691
m²
CONTROL
Control
lers
Magnocontrol
OPTIONS
Extensions
Optional rod extensions of 500, 800, 1000, 1500 & 2000 mm
Colour
Optional paint or hydroprinting
Controller
Magnocontrol 10
-
25
REGULATION
Directives
2014/35/
U
E
2014/30/UE
2009/125/CE
Design and construction
EN 60335
-
1
EN 60335-2-80
EN 62233
EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-3
* Following AMCA 230-99 * Air Speed > 0.5 m/s ** Air Speed > 0.2 m/s

AIRMAX
7
3 DIMENSIONS
The Anemoi AIRMAX has five different diameters. The height of the fan can also be varied by changing the length
of the extension rod. The fan comes with a standard 800mm extension.
The next figure shows the fan dimensions with an extension drop of 800 mm:
Model
Airmax 300
Airmax 400
Airmax 500
Airmax 600
Airmax 660
øA (
Fan diameter
) [mm]
3050
4050
5050
6050
6650
D (
fan height with standard downrod)
[mm]
1250
1270
1270
1290
1304
E
(standard downrod lenght)
[mm]
800
800
800
800
800

AIRMAX
8
4 DELIVERY
The Anemoi Airpro [L] fan is delivered in two wood boxes, one including the motor parts and the other the blades.
Handle the fan boxes carefully and with proper lifting equipment to avoid any damage.
CAUTION!
Use proper lifting equipment to handle the motor and blade boxes. Otherwise, the fan could be damaged
and there is risk of accident.
4.1 Package Dimensions & Weights
The dimensions and weights of these boxes are listed in the following table:
Model
Box
WIDTH (mm)
DEPTH (mm)
HEIGHT (mm)
WEIGHT (kg)
AIRMAX 400 Motor 900 900 650 90
Blades 380 1950 240 27
AIRMAX 550 Motor 750 700 600 90
Blades 380 1950 240 27
AIRMAX 660 Motor 900 900 650 110
Blades 370 3400 240 50

AIRMAX
9
4.2 Packing List
The following tables include the different pieces sent inside the boxes. Please check the status and quantity of the
fan equipment and the supporting parts immediately after you have opened the box to make sure that the goods
received are in accordance with your order. If parts are missing or damaged, please inform our company's
responsible person immediately for revision.
Motor box:
NO. Component name QTY
1 Motor 1 pc
2 Standard 800mm length downrod 1 pc
3 Ceiling fixing brackets 2 pcs
SMALL EQUIPMENT & SCREWS
Component name
Nº
Components
QTY
Fixing extension rod to ceiling
brackets
4 M12 Screws 2
5 M12 Locknuts 4
6 M12 Flat washer 2
7 M12 Spring washer 2
Fixing extension rod to motor 4 M12 Screws 2
5 M12 Locknuts 4
6 M12 Flat washer 2
7 M12 Spring washer 2
Fixing Blades to motor 8 M8 Screws 10
9 M8 Locknuts 10
10 M10 Spring washer 10
Bottom cover 11 Bottom cover 1
12 M4 Screws 5
End Caps 13 End caps 5
14 Screws 10
Electric wires 15 Electric cables with plugs 1
Safety cables 16 Ø5mm security wire with one ring 1
17 Ø5mm wire with two rings 2
18 U-clamp 2
19 7mm snap-hooks 2
20 Shackle 1
Guy wires fixation 21 Ø3mm stabilizing wires with
turnbuckle
4
22 5mm snap-hooks 5
23 U-clamp 8
Blades box:
NO. Component name QTY
24 Blade 5 pcs

AIRMAX
10
5 MECHANICAL INSTALLATION
CAUTION!
Follow the instructions and recommendations contained in this section carefully. Failure to do so may
result in incorrect installation.
The Anemoi AIRMAX fan is designed for ceiling installation. Ensure that the ceiling area chosen can hold the weight
of the fan and that there are no obstacles in its operating range. The maximum weight of the fan is about 123 kg.
The building structure should be capable to bear a torque of at least 350Nm.
Before installing the fan, it is necessary to sign and protect the working area to prevent anyone from going under
the fan. It is recommended to fence at least four meters around the lifting equipment.
Follow any national or local regulation regarding installations in height.
SAFETY!
Ensure that the ceiling area chosen can hold the weight and torque of the fan, and that there are no
obstacles in its operating range. Failure to do so may result in equipment damage or accident.
Ensure sign and protect the working area. Failure to do so may result in serious injury or death.
Ensure following any national or local regulation. Failure to do so may result in serious injury or death.
Do NOT install the fan while it is in operation or connected to the power supply. Doing so may result in
serious or fatal electrical shock.
5.1 Clearances
In order to ensure the maximum coverage of the Anemoi AIRMAX, all obstacles that may be encountered within
the radius of the fan and between the horizontal height of the fan's static position and the ceiling should be
considered before installation, ensuring that the fan has an appropriate clearance in all directions when running. In
order for a better fan performance, it is recommended that there be no walls at a distance equal to the diameter of
the fan.
If there are lamps above the fan blades, change their position if necessary, to avoid the strobe effect. Ensure that
the fan is installed at a height greater than 2,7 meters.
In any installation where fire sprinklers are placed, fan should not interfere with their operation.
Fan should not be placed near to supply air outlet or exhausting inlets of other HVAC equipment which could
decrease the fan capacity and compromise the indoor air quality as well as the occupants’ comfort.
The next figures show all clearances:

AIRMAX
11
Model
Airmax 300
Airmax 400
Airmax 500
Airmax 600
Airmax 660
ØA (fan diameter) [mm]
3050
4050
5050
6050
6650
B (max ceiling slope) [°]
15
15
15
15
15
C (min safety distance from side obstruction) [mm]
350
450
550
600
650
D (fan height with standard downrod) [mm]
1250
1270
1270
1270
1304
E (standard downrod lenght) [mm]
800
800
800
800
800
H (min fan installation height) [mm]
2700
2700
2700
2700
2700
If the fan is installed in an inclined roof, ensure that these minimum distances are achieved and add a higher
extension rod if necessary, to allow the fan take enough air and provide the maximum performance. It is
recommended to protect the fan if there is the possibility to receive impacts.
CAUTION!
Ensure that the minimum distances are achieved. Otherwise, the fan could be damaged.
Protect the fan if there is the possibility to receive impacts. Otherwise, the fan could be damaged.
5.2 Installation Tools
To install the fan, ensure having the following required tools:
NO. Name Quantity
1 Standard wrench set 1
2 Standard socket set with ratchet 1
3 Standard Allen wrench set 1
4 Phillips screwdriver 1
5 Hydraulic cutter 1
6 Torque wrench (5-45 Nm) 1
7 Flat head screwdriver 1
8 Multimeter 1
9 Strippers 1

AIRMAX
12
5.3 Ceiling Mount and Extension rod fixation
The Anemoi AIRMAX comes with mounting brackets to anchor the fan to the ceiling. As standard, all tooling is
provided so that the fan can be mounted concrete beams or directly to the ceiling. The fan is prepared to be installed
in inclined roofs. An 800 mm standard extension rod is provided, it must be fixed with M12 bolts.
1. Assemble the security set using the
Ø5mm security wire (16), the shackle
(20), the Ø5mm wires with rings (17)
and the 7mm snap-hooks (19).
2-1. Feed the safety cable (16) and
the electric wire (15) through the
extension rod (2).
2-2. Fix the extension rod (2) to the
ceiling bracket (3) by using Bolts Kit
(4*M12).
3. Fix the assembly to the ceiling /
beam through the 8 holes on the
brackets (3).
CAUTION!
Ensure that the M12 Mounting bracket / extension rod bolts are correctly fastened. Failure to do so may
result in equipment damage.
Ensure that the extension rod is in vertical position. Failure to do so may result in equipment damage.
Make sure that the cables pass correctly inside the extension. Failure to do so may result in equipment
damage.

AIRMAX
13
5.4 Motor Assembly
The motor is assembled to the extension rod by the M12 bolts provided, it must be tightened to prevent swinging
of the extension. It is very important that the extension rod stays vertical to avoid abnormal operation. By using a
level we ensure that the extension bar is completely vertical.
4. Fix the motor to the extension rod
by using the M12 bolts provided..
5. Connect the electric wire (15) to the
motor.
CAUTION!
Ensure that the M12 motor/extension bolts are correctly fastened. Failure to do so may result in equipment
damage.
Ensure that the extension rod is in vertical position once the motor is assembled. Failure to do so may
result in equipment damage.
Do not lift the motor weight alone. Failure to do so may result in serious injury or equipment damage.

AIRMAX
14
5.5 Safety Cable Installation
The motor contains a safety cable that must be installed to prevent the engine from failing after assembly. Make
sure that you have inserted the cable correctly through the extension rod and that you have correctly mounted the
safety set as indicated in section 5.3.
6. Remove the four transport feet from
the main body by unscrewing the
bolts.
7. Fix the safety cables to the motor
by using the snap-hooks (19). See
section 5.3 Safety cable set.
Hook the snap-hooks into two holes,
leaving one free between the two
hooked.
8. Fix the security wire to the ceiling /
beam using the clamps (18).
Drill the ceiling to install a pin that can
support the weight of the fan at a
distance of 20-30 cm from the fan’s
mounting frame.
Wall fixing screws/plugs are not
supplied.
SAFETY!
Ensure that the safety cable is correctly installed to prevent the fan from falling. Failure to do so may
result in serious personal injury or death and equipment damage.
Make sure the Wire Rope Clamp are properly tightened. Failure to do so may result in equipment damage.
Transport
foot
Hole

AIRMAX
15
5.6 Guy Wires Fixation (optional)
If oscillations are detected, winds must be installed as part of the assembly process. The use of winds is
recommended for extensions greater than the standard extension. To do so, there is an auxiliary hardware with
Turn Buckle, Wire Rope Clamp and Beam Clamp set. Please introduce the guy wires in the Guy wire bracket fixed
in the motor in a 45º angle as shown below:
9-1. Connect the ø3mm stabilizing
wires with turnbuckle (21) to the motor
with the 5mm snap-hook (22) and
stabilize the fan.
9-2. With the aid of a spirit level
placed against the downrod, tighten
the turnbuckles by hand in a
crisscross pattern while periodically
checking to ensure that the fan is
level.
10-1. Looking up from the bottom of
ceiling fan, the angle between each
cables and I-beams is recommended
to be 45-degrees.
10-2 The angle of the cables should
be and 45 degrees angle from
horizontal surface.
11. Securely fix the other end of the
stabilizing wires to the ceiling using
the clamps (23). Wall plugs/screws
are not supplied.
CAUTION!
Fasten the guy wires clamps correctly to ensure that they cannot be unscrewed. Failure to do so may
result in equipment damage.
Make sure the turnbuckles, snap-hooks, and U-clamps are properly tightened. Failure to do so could result
in equipment damage.

AIRMAX
16
5.7 Blades Assembly
To assemble the Blades, it is necessary to screw the plastic End Caps, and introduce and fix them to the motor
guides. Use the bolts provided to fix the end caps before lifting the blade to the motor. The fan blades must be
installed in a specific sense, with the concave side in the bottom.
12. Insert the end-cap into the blade
and tighten with the 7 bolt kits
provided.
Insert the blade into the motor bracket
and tighten it with the M8 bolts
provided.
13. Finally, fix the bottom cover (11)
using the 5*M4 bolt provided (12).
CAUTION!
Make sure the blades are installed in the correct sense. Failure to do so may result in incorrect installation.
Make sure the blades bolts are properly tightened. Failure to do so may result in incorrect installation.
Check that there are no objects that can avoid the blades rotation. Failure to do so may result in equipment
damage.

AIRMAX
17
6 ELECTRICAL INSTALLATION
WARNING!
Follow the instructions and recommendations contained in this section. Failure to do so may result in
serious injury or death.
The Anemoi AIRMAX fan motor is controlled by an integrated motor drive. To ensure fan operation, the user must
connect cable power and control cables.
Before installing the fan, it is necessary to remove power supply to prevent any accident. Check that power supply
is disconnected before starting the installation.
All cabling must comply with national and local regulations on cable cross-sections and ambient temperature.
Copper (60°C/75°C) conductors are recommended.
Follow any national or local regulation regarding electrical installations.
CAUTION!
Follow national and local electrical regulations. Failure to do so may result in serious injury or death.
Check that power supply is disconnected before starting the installation. Failure to do so may result in
serious injury or death.
Do NOT install the fan with wet hands. Failure to do so may result in serious injury or death.

AIRMAX
18
6.1 Conexiones de potencia
The Anemoi AIRMAX engine must be connected to the power supply with an electrical voltage of 380-400 VAC
(III, 50/60Hz). Please see the voltage and consumption for this HVLS fan on the technical characteristics to
guarantee a properly installation.
You may use shielded or unshielded cables. Please root the cables along the ceiling beams using the shortest
possible path.
WARNING!
Do NOT use wires with worn or damaged insulation. Doing so may result in serious or fatal electrical shock,
fire or other accidents.
Ensure that the wires are held securely and protected from abrasion, chaffing, overload or other
damage. Risk of serious or fatal electrical shock, fire or other accidents.
Do NOT connect the motor to the input line directly. Failure to do so may result in equipment damage.
A circuit breaker must be installed for each fan. Failure to do so may result in equipment damage.

AIRMAX
19
6.2 Conexiones de control
The Anemoi AIRMAX fan needs an external control to work. The external control is connected directly to the fan
control board using shielded cable type modbus cable RS485 2x2x0.50 mm² POSCY.
The following figure shows the detail of the control connectors:
PORT DEFINED
Modbus Control Line
B White Negative (-) for data communication
A Grey Positive (+) for data communication
CAUTION!
Never mix electrical and control wiring. Doing so may lead to interference.

AIRMAX
20
6.2.1 Multi Fans Installation
In installations with multiple fans, it is possible to control the fans using a single controller. In this case, the
controller is connected to the different by using control connections. The connection must be made in series.
The next figure shows the correct connections:
WARNING!
Never mix electrical and control wiring. Doing so may lead to interference.
The earth meshes of each cable section must remain together. Failure to do so may lead to communication
errors.
Connect only one end of the earthing to the ground. Failure to do so may lead to communication errors.
This manual suits for next models
4
Table of contents
Other ANEMOI Fan manuals
Popular Fan manuals by other brands

Movincool
Movincool CM 25 Operation manual

Berbel
Berbel BMK-F 125 installation instructions

Fanimation
Fanimation EMBRACE FPS7955B manual

Progress Lighting
Progress Lighting AirPro P250034 installation manual

VENCO
VENCO VAX-J series Installation, operation and maintenance manual

Colasit
Colasit CMHV 450 Operation manual

COMPANION
COMPANION COMP389 instruction manual

nedis
nedis FNCL10 20 Series quick start guide

Hunter
Hunter 45057-01 Owner's guide and installation manual

Nuaire Group
Nuaire Group DRIMASTER Installation and Maintenance

Monsoon
Monsoon MON-CONT Installation and wiring instructions

Minka-Aire
Minka-Aire Mystique F611 instruction manual