IMPORTANT: Read the Code Requirements
and the Installation Requirements and Iinstruc-
tions carefully, before starting the installation.
Contact the factory (800/ 837-2638) if any
problems or questions arise.
Thefryerinstallationmustconformwith local
codes,or in theabsence of local codes,with the
NationalFuel Gas Code, ANSI Z223.1 (latest
edition);theNatural GasInstallation Code,CAN/
CGA-B149.1(latest edition); or the PropaneGas
InstallationCode, CAN/CGA-B149.2(latest
edition),asapplicable,including:
a. Disconnectthefryeranditsindividualshutoff
valvefromthegassupplypipingsystemduring
anypressuretesting ofthegas supplysystemat
testpressures in excess of ½ psig (3.45kPa).
b. Isolatethefryerfromthegas supply piping
systemduringanypressuretesting ofthegas
supplysystem attest pressures equalto or less
than ½ psig (3.45 kPa).
c. For fryersutilizingfloorcasters,thefryerinstal-
lationshallbe madewith a connectorthat
complieswiththe Standardfor Connectors for
MovableGas Appliances, ANSIZ21.69
(latestedition) orCAN/CGA 6.16 (latest
edition),anda quick-disconnectdevicethat
complieswiththe StandardforQuick-Discon-
nectDevices forUse withGas Fuel, ANSI
Z21.41or CAN/CGA 1-6.9 (latest edition).
d. Restrict themovement of a caster-equipped
fryerbyusingalimitingdevice(forexample,a
cableattached both tothe fryerand to a fix-
tureattached tothe site structure) to avoid
dependingon theconnector andthe quick-
disconnectdeviceor itsassociated piping to
limitfryermovement.
e. Install thisfryeronanon-combustiblefloor
withits back andsides at least6”awayfrom
anycombustiblewall,asshown in Figure2.
WARNING
Install this fryer under a ventilation
hood that conducts combustion pro-
ducts outside the building. Venting
must comply with ANSI/NFPA 96
(latest edition).
f. Install thisfryerinalocation whereadequate
combustionandventilationairisavailable.
Keepthe areadirectly infront ofthe fryeropen
foradequate air flow to theburners. DO
NOTobstruct theflow ofcombustion and
ventilationair.
g. Keepthefryer area free and clear from
combustiblesanddebris.
h. Attacharestraining devicetoeach fryer,to
preventtheunitfromtipping,whichcould
causesplashingofhotliquid.
CODE REQUIREMENTSCODE REQUIREMENTS
CODE REQUIREMENTSCODE REQUIREMENTS
CODE REQUIREMENTS
Figure 2. Fryer Site Installation Requirements
From the top of the flue on
the fryer, allow a minimum
of at least 10 inches verti-
cal clearance beneath a
ventilating hood.