manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ANTAIRA
  6. •
  7. Switch
  8. •
  9. ANTAIRA LNX-1204G-10G-SFP User manual

ANTAIRA LNX-1204G-10G-SFP User manual

Antaira Technologies
LNX-1204G-10G-SFP
12-Port Industrial Gigabit Unmanaged Ethernet Switch,
w/8*10/100/1000Tx, 2*1000 SFP slots, and 2*10G SFP+ Slots
Quick Installation Guide
Version 1.0
(July 2020)
Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com
19020000000103
Package Check List
The package contains the following items:
⚫1 –Quick installation guide
⚫1 –LNX-1204G-10G-SFP
⚫1 –Wall mounting bracket set with screws
⚫1 –DC cable –18 AWG & DC jack 5.5 x 2.1mm
⚫1 –RJ45 dust cover set
Front Panel Layout
Top Panel View
LNX-1204G-10G-SFP top panel is equipped with one 6-pin
removal terminal block connector for dual DC power inputs
(12~48VDC).
Product Overview
System Interface/Performance
All RJ45 ports support the auto MDI/MDI-X function
Embedded 8*10/100/1000Tx RJ45 ports, 2*1000 SFP slots,
and 2*10G SFP+ slots
Store-and-Forward switching architecture
16K MAC address table
Supports 10Kbytes jumbo frame
8Mbits memory buffer
Power Input & Connection
DC 12 to 48V redundant power, with a 6-pin removal
terminal block
Max. current: 0.83A
Relay contact: 24VDC, 1A resistive
It is recommended to use a UL listed industrial power supply
Operating Temperature
Standard operating temperature model: -40°C to 65°C
Case/Installation
IP30 protection
DIN-Rail and wall mount design
LED Indicators
LED
Color
Description
Power 1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
Power 2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 is active
LAN Port 1~8
(Upper LED)
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
LAN Port 1~8
(Lower LED)
Green
On
Connected to network, 10/100Mbps
Flashing
Networking is active
Off
Not connected to network
SFP Port 9~10
LINK/ACT
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
SFP Port
11~12
LINK/ACT
Green
On
Connected to network, 10Gbps
Flashing
Networking is active
Off
Not connected to network
Grounding Screw
6-Pin Removal Terminal Block (Power Input)
LAN# 1~8 –10/100/1000Tx RJ45
LAN# 1~8 LED for Link/Activity Status
10/100Mbps
LED for Power 1, Power 2, and Fault
Grounding Screw
6-Pin Removal Terminal Block (Power Input)
LAN# 1~8 LED for Link/Activity Status
1000Mbps
SFP# 11~12 LED for Link/Activity Status
10G
SFP# 11~12 –10G
SFP# 9~10 LED for Link/Activity Status
1000 Mbps
SFP# 9~10 –1000Mbps
Quick Installation
Ethernet Ports
RJ45 Ports (Auto MDI/MDIX)
All RJ45 ports are auto-sensing for 10Base-T, 100Base-TX or
1000Base-T device connections. Please follow the wiring pin
assignment table below for Ethernet port installation.
RJ45 Ethernet Port Pin Outs
Pins
T568A Color
T568B Color
10Base-T,
100Base-TX
1000
Base-T(X)
Pin 1
white/green stripe
white/orange stripe
Rx+
TP0+
Pin 2
green solid
orange solid
Rx-
TP0-
Pin 3
white/orange stripe
white/green stripe
Tx+
TP1+
Pin 4
blue solid
blue solid
unused
TP2+
Pin 5
white/blue stripe
white/blue stripe
unused
TP2-
Pin 6
orange solid
green solid
Tx-
TP1-
Pin 7
white/brown stripe
white/brown stripe
unused
TP3+
Pin 8
brown solid
brown solid
unused
TP3-
Power Input Wiring
Please follow the steps below to insert the power wire:
1. Insert the positive and negative wires into the PWR1
(V1+, V1-) and PWR2 (V2+, V2-) contacts on the
terminal block connector as shown below in Figure 1.
2. Tighten the wire-clamp screws to prevent the wires from
loosening, as shown below in Figure 2.
Figure 1 Figure 2
Industrial Switch Mounting
DIN-Rail Mounting
The DIN-Rail bracket is pre-installed on
the industrial Ethernet switch from the
factory. Please refer to Figure 3 for a
DIN-Rail bracket installation reference.
Follow the steps below for installing the
industrial switch on the DIN-Rail track:
1. Insert the top of the DIN-Rail on to the
track as shown below in Figure 4.
2. Lightly pull down the bracket on to the
rail as shown below in Figure 5.
3. Check if the bracket is mounted tightly
on the rail.
4. To remove the industrial
Ethernet
switch
from the rail, do the opposite from the steps above.
Figure 4
Wall Mounting
Follow the steps below to mount the industrial Ethernet switch
using the wall mounting bracket as shown below in Figure 6.
1. Remove the DIN-Rail bracket from the industrial Ethernet
switch by loosening the screws.
2. Place the wall mounting brackets on the
top and bottom of the industrial Ethernet
switch.
3. Use the screws to screw the wall
mounting bracket on the industrial
Ethernet switch.
4. Use the hook holes at the corners of the
wall mounting bracket to hang the
industrial Ethernet switch on the wall.
5. To remove the wall mount bracket, do the
opposite from the steps above.
Field Maintenance and Service
⚫If the device requires servicing of any kind, the user is
required to disconnect and remove it from its mounting. The
initial installation should be done in a way that makes this as
convenient as possible.
⚫Voltage/power lines should be properly insulated as well as
other cables. Be careful when handling them so as to not trip
over.
⚫Do not under any circumstance insert foreign objects of any
kind into the heat dissipation holes located in the different
faces of the device. This may not only harm the internal
layout, but might cause harm to user as well.
⚫Do not under any circumstance open the device for any
reason. Please contact your dealer for any repair needed or
follow the instructions within the manual.
Warranty Policy
Warranty Conditions
Products supplied by Antaira Technologies are covered in this
warranty for sub-standard performance or defective
workmanship. The warranty is not, however, extended to goods
damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock,
earthquake
(c) Use of unqualified power supply, connectors, or
unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number
from Antaira before shipping the goods for repair or
replacement.
•Within the warranty period (based on the invoice date), all
parts and labor are free of charge to the customers.
•Customers are responsible for the cost of parts and labor, if
the products are out of warranty.
•For RMA service, customers are responsible for the shipping
expense for shipping the RMA unit(s) to Antaira. Antaira is
responsible for the shipping expense via a ground service
for the return repair/replace unit(s) back to customers.
Limited Liability
Antaira would not be held responsible for any consequential
losses from using Antaira’s product.
Warranty Period
5-Year Warranty
Antaira’s Customer Service and Support
•Antaira’s Technical Service & Support Centers:
+ 844-268-2472 (Antaira US Headquarter)
+ 48-22-862-88-81 (Antaira Europe Office)
+ 886-2-2218-9733 (Antaira Asia Office)
•Antaira’s Web Sites & Repair/Support Emails:
www.antaira.com / [email protected]
www.antaira.eu / [email protected]
www.antaira.com.tw / [email protected]
*Any changes will be announced on the Antaira website.
Figure 3
Figure 6
Figure 5

Other manuals for LNX-1204G-10G-SFP

1

Other ANTAIRA Switch manuals

ANTAIRA LNX-800-M12-T User manual

ANTAIRA

ANTAIRA LNX-800-M12-T User manual

ANTAIRA LMX-C602G-SFP-V2 Series User manual

ANTAIRA

ANTAIRA LMX-C602G-SFP-V2 Series User manual

ANTAIRA LNX-1604G-SFP Series User manual

ANTAIRA

ANTAIRA LNX-1604G-SFP Series User manual

ANTAIRA LNX-500A-T User manual

ANTAIRA

ANTAIRA LNX-500A-T User manual

ANTAIRA LMP-0501 V2 User manual

ANTAIRA

ANTAIRA LMP-0501 V2 User manual

ANTAIRA LNP-0800G-24 Series User manual

ANTAIRA

ANTAIRA LNP-0800G-24 Series User manual

ANTAIRA LMP-0602-24-V2 Series User manual

ANTAIRA

ANTAIRA LMP-0602-24-V2 Series User manual

ANTAIRA LNP-1002G-SFP Series User manual

ANTAIRA

ANTAIRA LNP-1002G-SFP Series User manual

ANTAIRA LNP-1204G-SFP Series User manual

ANTAIRA

ANTAIRA LNP-1204G-SFP Series User manual

ANTAIRA LNP-C800G Series User manual

ANTAIRA

ANTAIRA LNP-C800G Series User manual

ANTAIRA LNP-0500G Series User manual

ANTAIRA

ANTAIRA LNP-0500G Series User manual

ANTAIRA LNP-0501 Series User manual

ANTAIRA

ANTAIRA LNP-0501 Series User manual

ANTAIRA LMP-1600G Series User manual

ANTAIRA

ANTAIRA LMP-1600G Series User manual

ANTAIRA LMX-0802-M User manual

ANTAIRA

ANTAIRA LMX-0802-M User manual

ANTAIRA LNX-2004G-SFP Series User manual

ANTAIRA

ANTAIRA LNX-2004G-SFP Series User manual

ANTAIRA LMX-1204G-SFP Series User manual

ANTAIRA

ANTAIRA LMX-1204G-SFP Series User manual

ANTAIRA LMP-0804G-SFP Series User manual

ANTAIRA

ANTAIRA LMP-0804G-SFP Series User manual

ANTAIRA LNP-0500G-bt-24 Series User manual

ANTAIRA

ANTAIRA LNP-0500G-bt-24 Series User manual

ANTAIRA LNP-1002G-10G-SFP-24 User manual

ANTAIRA

ANTAIRA LNP-1002G-10G-SFP-24 User manual

ANTAIRA LNX-1002C-SFP Series User manual

ANTAIRA

ANTAIRA LNX-1002C-SFP Series User manual

ANTAIRA LMP-2012G-SFP Series User manual

ANTAIRA

ANTAIRA LMP-2012G-SFP Series User manual

ANTAIRA LNP-800AGH Series User manual

ANTAIRA

ANTAIRA LNP-800AGH Series User manual

ANTAIRA LNX-0602 series User manual

ANTAIRA

ANTAIRA LNX-0602 series User manual

ANTAIRA LNP-0602 Series User manual

ANTAIRA

ANTAIRA LNP-0602 Series User manual

Popular Switch manuals by other brands

CyberData 11171 Installation quick reference

CyberData

CyberData 11171 Installation quick reference

Humminbird 531871-1_A Installation

Humminbird

Humminbird 531871-1_A Installation

Siemens SITRANS LPS200 operating instructions

Siemens

Siemens SITRANS LPS200 operating instructions

NETGEAR ProSAFE M4300 series installation guide

NETGEAR

NETGEAR ProSAFE M4300 series installation guide

Enable-IT 8805 quick start guide

Enable-IT

Enable-IT 8805 quick start guide

D-Link DGS-1250-28X Quick installation guide

D-Link

D-Link DGS-1250-28X Quick installation guide

CompanyBlue JKFSWT INSTALLATION & SAFETY INSTRUCTIONS

CompanyBlue

CompanyBlue JKFSWT INSTALLATION & SAFETY INSTRUCTIONS

Linkskey LDV-DM712AUSK Quick installation guide

Linkskey

Linkskey LDV-DM712AUSK Quick installation guide

Siemens 3NJ631 Series operating instructions

Siemens

Siemens 3NJ631 Series operating instructions

Ross Carbonite Series Setup manual

Ross

Ross Carbonite Series Setup manual

Biamp EASYCONNECT MPX 100 overview

Biamp

Biamp EASYCONNECT MPX 100 overview

Siemens SIMATIC NET RUGGEDCOM RS920L installation manual

Siemens

Siemens SIMATIC NET RUGGEDCOM RS920L installation manual

Intel Express 410T Quick start and user guide

Intel

Intel Express 410T Quick start and user guide

TLS Electronics 875450 user manual

TLS Electronics

TLS Electronics 875450 user manual

SMC Networks ZSE3 instruction manual

SMC Networks

SMC Networks ZSE3 instruction manual

Siemens Sirius 3RT1926-2E Original operating instructions

Siemens

Siemens Sirius 3RT1926-2E Original operating instructions

ifs NS3562-8P-2S-V2 user manual

ifs

ifs NS3562-8P-2S-V2 user manual

Hitron HM-90 Series instruction manual

Hitron

Hitron HM-90 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.