manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Anton
  6. •
  7. Thermometer
  8. •
  9. Anton ADT 200 User manual

Anton ADT 200 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

serial no. ________________________________
calibrated by ______________date ___________
This instrument has been checked or calibrated
against reference instrument(s) calibrated by a
UKAS Accredited Calibration Laboratory.
INSTRUMENT RECORD CARD
model
Differential Thermometer
ADT 200 Differential
Thermometer
Operating Instructions
545-170ANN/22.04.16
Anton Industrial Services Ltd
Watford Business Park · WD18 8JA
tel: 0870 428 0075 · [email protected]
www.anton-group.com
GUARANTEE - This instrument carries a two-year
guarantee against defects in either components or
workmanship. During this period, products that
prove to be defective will, at the discretion of Anton,
be either repaired or replaced without charge.
This guarantee does not apply to probes, where a
six-month period is offered. The product guarantee
does not cover damage caused by fair wear and
tear, abnormal storage conditions, incorrect use,
accidental misuse, abuse, neglect, misapplication
or modification.
0 °C 1000 °C
thermocouple
order code
ADT 200
INSTRUMENT OPERATION - Connect
probes via the socket(s) located at the top
of the instrument. (The Anton ADT 200
Differential thermometer use a miniature
type K thermocouple connector/s). Switch
the instrument on and apply the tip of the
probe to the substance or medium to be
measured. The instrument reading may take
a few seconds to stabilise, depending on the
nature of the measurement and sensitivity of
the probe.
HOLD - Press the HOLD button to stop
measurements, press again to continue
measuring.
AUTO-OFF - The unit will switch off
automatically after 10 minutes. To disable
auto-off press the HOLD button whilst
switching on the instrument (this is reset when
the instrument is switched off).
OPEN CIRCUIT/FAULTY PROBE - If the probe
has developed an 'Open Circuit' fault the
instrument will display 'Err'.
SENSORS - Anton ADT 200 Differential
thermometer should only be used with type
K (Nickel Chromium/Nickel Aluminium)
thermocouple probes (to BS EN 60584-2)
fitted with miniature type K thermocouple
plugs (to BS EN 50212). This instrument
is designed to be compatible with Anton
manufactured probes.
BATTERY REPLACEMENT - The instrument
will display a low battery symbol to warn that
the batteries will need changing soon. The
instrument continues to measure accurately
but after further usage the instrument will
display 'flat bat' and shutdown. Replace the
three AAA batteries located under the rear
case half that is held in place by six screws.
Check the seal for damage and carefully
replace the rear case half and re-fit and
tighten the screws.
MAX/MIN - Press the MAX/MIN button to
display the values. The instrument retains the
max/min values when switched off. To reset,
press the MAX/MIN button for three seconds,
'rst' will be displayed.
BACKLIGHT - Press the HOLD button for two
seconds. Please Note: the backlight will
not operate if the low battery symbol is being
displayed. (Backlight timeout = 20 seconds).
MODE - Press the MODE button to scroll
through T1, T2 or T1 - T2.
NULL - Press the MODE button for three
seconds to null the differential reading to
0.0 °C/°F.
°C/°F - Press and hold ON/OFF button for
five seconds at start-up.
WARNING: IPA and other solvents may
cause damage to the case and screen of
this instrument.