Anton ADT 200 User manual

serial no. ________________________________
calibrated by ______________date ___________
This instrument has been checked or calibrated
against reference instrument(s) calibrated by a
UKAS Accredited Calibration Laboratory.
INSTRUMENT RECORD CARD
model
Differential Thermometer
ADT 200 Differential
Thermometer
Operating Instructions
545-170ANN/22.04.16
Anton Industrial Services Ltd
Watford Business Park · WD18 8JA
tel: 0870 428 0075 · [email protected]
www.anton-group.com
GUARANTEE - This instrument carries a two-year
guarantee against defects in either components or
workmanship. During this period, products that
prove to be defective will, at the discretion of Anton,
be either repaired or replaced without charge.
This guarantee does not apply to probes, where a
six-month period is offered. The product guarantee
does not cover damage caused by fair wear and
tear, abnormal storage conditions, incorrect use,
accidental misuse, abuse, neglect, misapplication
or modification.
0 °C 1000 °C
thermocouple
order code
ADT 200
INSTRUMENT OPERATION - Connect
probes via the socket(s) located at the top
of the instrument. (The Anton ADT 200
Differential thermometer use a miniature
type K thermocouple connector/s). Switch
the instrument on and apply the tip of the
probe to the substance or medium to be
measured. The instrument reading may take
a few seconds to stabilise, depending on the
nature of the measurement and sensitivity of
the probe.
HOLD - Press the HOLD button to stop
measurements, press again to continue
measuring.
AUTO-OFF - The unit will switch off
automatically after 10 minutes. To disable
auto-off press the HOLD button whilst
switching on the instrument (this is reset when
the instrument is switched off).
OPEN CIRCUIT/FAULTY PROBE - If the probe
has developed an 'Open Circuit' fault the
instrument will display 'Err'.
SENSORS - Anton ADT 200 Differential
thermometer should only be used with type
K (Nickel Chromium/Nickel Aluminium)
thermocouple probes (to BS EN 60584-2)
fitted with miniature type K thermocouple
plugs (to BS EN 50212). This instrument
is designed to be compatible with Anton
manufactured probes.
BATTERY REPLACEMENT - The instrument
will display a low battery symbol to warn that
the batteries will need changing soon. The
instrument continues to measure accurately
but after further usage the instrument will
display 'flat bat' and shutdown. Replace the
three AAA batteries located under the rear
case half that is held in place by six screws.
Check the seal for damage and carefully
replace the rear case half and re-fit and
tighten the screws.
MAX/MIN - Press the MAX/MIN button to
display the values. The instrument retains the
max/min values when switched off. To reset,
press the MAX/MIN button for three seconds,
'rst' will be displayed.
BACKLIGHT - Press the HOLD button for two
seconds. Please Note: the backlight will
not operate if the low battery symbol is being
displayed. (Backlight timeout = 20 seconds).
MODE - Press the MODE button to scroll
through T1, T2 or T1 - T2.
NULL - Press the MODE button for three
seconds to null the differential reading to
0.0 °C/°F.
°C/°F - Press and hold ON/OFF button for
five seconds at start-up.
WARNING: IPA and other solvents may
cause damage to the case and screen of
this instrument.

Popular Thermometer manuals by other brands

Philips SBCSC550 Instructions for use

Philips

Philips SBCSC550 Instructions for use

Perel EVM440 user manual

Perel

Perel EVM440 user manual

Exergen TemporalScanner TAT-5000S-RS232 Series Operation manual

Exergen

Exergen TemporalScanner TAT-5000S-RS232 Series Operation manual

Martel 308 instruction manual

Martel

Martel 308 instruction manual

Oregon Scientific RMR183 user manual

Oregon Scientific

Oregon Scientific RMR183 user manual

Braun ThermoScan IRT 6030 manual

Braun

Braun ThermoScan IRT 6030 manual

Safety Vision SV-IR-TEMP user guide

Safety Vision

Safety Vision SV-IR-TEMP user guide

Medisana 76120 FTN instruction manual

Medisana

Medisana 76120 FTN instruction manual

Vega Technologies IR-08MT instruction manual

Vega Technologies

Vega Technologies IR-08MT instruction manual

Timex TX6130 brochure

Timex

Timex TX6130 brochure

Lumiscope 2220 instruction manual

Lumiscope

Lumiscope 2220 instruction manual

Omega DP251 Operator's manual

Omega

Omega DP251 Operator's manual

ZAKARIAN K65894 manual

ZAKARIAN

ZAKARIAN K65894 manual

RADWAG GT105K-12/Z user manual

RADWAG

RADWAG GT105K-12/Z user manual

Beta 1760/IR500 Instructions for use

Beta

Beta 1760/IR500 Instructions for use

Auber Instruments AT210 Notes on Use

Auber Instruments

Auber Instruments AT210 Notes on Use

Vernier GW-TEMP quick start guide

Vernier

Vernier GW-TEMP quick start guide

OWIM 285321 Operation and safety notes

OWIM

OWIM 285321 Operation and safety notes

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.