manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Antunes
  6. •
  7. Water Filtration System
  8. •
  9. Antunes 9700901 User manual

Antunes 9700901 User manual

SCALE INHIBITOR SYSTEM (P/N 9700901)
+1-877-392-7854 Page 1 of 2 P/N 1010449 Rev. B 07/17
TOOLS:
• Mounting Hardware (Not Provided)
• Drill with bits
• Tape Measure
• Pipe Wrenches
• Adjustable Wrenches
• Level
• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord
• Screwdriver (Flat Blade and Phillips)
• Two Gallon Bucket
• Fresh 6% unscented liquid chlorine bleach
PARTS INCLUDED:
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)
1 - Housing, Bowl, and Head (2180243)
1 - Wrench, Filter (2180244)
1 - Tee 3/4” NPT (2190130)
1 - Nipple, Hex 3/4” NPT x 1-1/2” LG (2190144)
1 - Scale Inhibitor Element Kit (7000540)
1 - Scale Inhibitor System Instruction Sheet (P/N 1010449)
CAUTION
Do not use this system with water that is microbiologi-
cally unsafe or of unknown quality without adequate dis-
infection installed before or after the system.
General
If you experience any problems with these instructions, or if
any parts are damaged or missing, contact Antunes Technical
Service at +1-877-392-7854 (toll-free).
The Scale Inhibitor System provides mineral scale prevention
by feeding scale control compounds into the water. It should be
installed upstream of any ice making, beverage, or steam equip-
ment.
Equipment Setup
When installing the system, pay attention to the following guide-
lines:
• Do not install above electrical equipment.
• Allow space below the Scale Inhibitor Housing for Element
change out.
PLUMBING
NOTE: This system is designed to be used on tap water not
to exceed 100°F (38°C) or 100 psig (690 kPa). The kit must
be connected to the COLD water line. Do not connect the
kit to the hot water line.
The Scale Inhibitor System has the following connections:
• Inlet 3/4” NPT
• Outlet 3/4” NPT
When making a plumbing connection to the System, use a
back-up wrench on the supporting plumbing. Always use a
quality, approved pipe sealant or thread seal tape on the pipe
threads. Be careful not to get the pipe sealant inside the pipe
when making connections.
DO NOT over tighten the connections. The use of plastic fittings
when connecting to the plastic head will reduce the possibility of
cracking the head due to over tightening.
If soldered plumbing is used, do not apply heat to, or near, the
Head. The use of union (o-ring seal) connections is highly rec-
ommended for ease of installation and future servicing.
CAUTION
This equipment must be installed to comply with the
basic plumbing code of the Building Officials and Code
Administrators, Inc. (BOCA) and the Food Service
Sanitation Manual of the Food and Drug Administration
(FDA).
CAUTION
Water pressure must not exceed 100 psig. To reduce
water pressure, install a water pressure regulator and set
the water pressure to below 100 psig.
Head Bracket
and Screws (8)
Housing
Clear
Head
O-Ring
(incl. with Head)
Scale
Inhibiter
Element
Filter Wrench
Figure 1. Scale Inhibitor System
ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
SCALE INHIBITOR SYSTEM (P/N 9700901)
+1-877-392-7854 Page 2 of 2 P/N 1010449 Rev. B 07/17
INLET WATER PLUMBING
The plumbing leading to the Scale Inhibitor System must be
flushed clear of all debris before connecting to the inlet connec-
tion of a water system. Hold a bucket at the inlet water line and
slowly open the inlet water valve. Allow the pipe to flush until all
debris is removed.
MOUNTING THE SYSTEM
Before mounting the Scale Inhibitor System, please consider the
items listed below:
• The Housing must be mounted with sufficient access for
element replacement. The Housing is 14 inches tall. An
additional 2 inches should be allowed below the clear bowl
to allow proper access when changing elements.
• The kit must be mounted with hardware capable of support-
ing 10 lbs or more of weight.
• The mounting bracket supplied with the system must be
mounted in the UP position (See Figure 2). The bracket
comes with short screws for attaching to the head and long
screws for attaching the bracket to the wall.
NOTE: Only the short screws should be used for mounting
the Head to the Bracket.
• The Head can be mounted with the inlet on the left or on
the right. When the inlet is on the left, the red pressure
relief button is on the left. Refer to Figure 2 for help in locat-
ing the Inlet and Outlet ports.
• The Scale Stick Inhibitor System kit must be installed
upstream of all consumable water access points.
• The inlet water should only be connected to the “INLET”
port on the Head. The filtered water should only be con-
nected to the “OUTLET” port on the Head. See Figure 2.
Attach the mounting bracket to the Head BEFORE attaching to
the wall.
ATTACHING TO THE INLET
Both the Inlet and Outlet connections have a 3/4” NPT female
thread. Be careful not to overtighten a fitting into the Head.
Plastic fittings are recommended for connecting to the Head.
Use a pipe thread sealant approved for use in drinking water
applications with plastic fittings.
Sanitizing the System and Lines
INLET
OUTLET
Red Pressure
Relief button
Attach Bracket to
Wall in this position
Figure 2. Mounting Bracket (Up Position ONLY)
CAUTION
DO NOT connect the Inlet water to the Outlet port
on the head.
The plumbing must be sanitized to eliminate possible contami-
nation that may have occurred during the installation process.
Liquid chlorine bleach (regular bleach, unscented 6% sodium
hypochlorite) can be used to sanitize the plumbing. The amount
of bleach to use depends on the system installed and the
amount of plumbing downstream of the Scale Inhibitor System.
Generally 10 drops (one-half ml) of bleach is sufficient to sani-
tize the bowl and associated plumbing.
CAUTION
Make sure the follow any handling or safety instructions
supplied with the bleach.
NOTE: When sanitizing the Scale Inhibitor System, make
sure the Scale Inhibitor element is not installed or is
removed from the housing before sanitizing.
1. Direct the water line from the outlet of the Head to a
drain.
2. Unscrew the Housing counter clockwise to remove the
Housing from the Head.
3. Pour the liquid chlorine bleach into the bowl.
4. Screw the Housing (containing the bleach) into the Head.
Tighten the bowl until it stops. The Housing will come to a
hard stop at the end of the thread. Use the filter wrench if
necessary.
5. Slowly turn on the water supply and pressurize the sys-
tem. Allow water to flow out of the Housing until the odor
of bleach is present.
6. Turn off the water supply and let the system stand without
water flow for at least 15 minutes to allow the bleach to
sanitize the pipes.
7. After 15 minutes without water flow, turn on the water
supply and flush until the presence of bleach is gone.
8. Shut off the water supply and depressurize the system.
NOTE: Refer to document 1010448, provided with this sys-
tem, for instructions on replacing and rinsing the Scale
Inhibitor Kit.
ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

Other Antunes Water Filtration System manuals

Antunes VZN-500 Series User manual

Antunes

Antunes VZN-500 Series User manual

Antunes VZN-520H User manual

Antunes

Antunes VZN-520H User manual

Antunes UF-216CC User manual

Antunes

Antunes UF-216CC User manual

Antunes VZN-441VE User manual

Antunes

Antunes VZN-441VE User manual

Antunes UFL-510 User manual

Antunes

Antunes UFL-510 User manual

Antunes VZN User manual

Antunes

Antunes VZN User manual

Antunes VZN-441 User manual

Antunes

Antunes VZN-441 User manual

Antunes VZN-411V User manual

Antunes

Antunes VZN-411V User manual

Antunes DMS-100 User manual

Antunes

Antunes DMS-100 User manual

Antunes VZN T5 Series User manual

Antunes

Antunes VZN T5 Series User manual

Antunes TAC-02 User manual

Antunes

Antunes TAC-02 User manual

Antunes VZN-420H User manual

Antunes

Antunes VZN-420H User manual

Antunes VZN-421H User manual

Antunes

Antunes VZN-421H User manual

Antunes WATER WRO-50-R User manual

Antunes

Antunes WATER WRO-50-R User manual

Antunes TAC-01 User manual

Antunes

Antunes TAC-01 User manual

Antunes UFL-420 Series User manual

Antunes

Antunes UFL-420 Series User manual

Antunes VZN-441VA User manual

Antunes

Antunes VZN-441VA User manual

Antunes VZN Series User manual

Antunes

Antunes VZN Series User manual

Antunes UFL-410 Series User manual

Antunes

Antunes UFL-410 Series User manual

Antunes VZN-500 Series User manual

Antunes

Antunes VZN-500 Series User manual

Antunes AQ-RO-400-NT User manual

Antunes

Antunes AQ-RO-400-NT User manual

Antunes VZN-441VC User manual

Antunes

Antunes VZN-441VC User manual

Antunes 9700913 User manual

Antunes

Antunes 9700913 User manual

Popular Water Filtration System manuals by other brands

CircuPool Universal UL-25 Installation and operation guide

CircuPool

CircuPool Universal UL-25 Installation and operation guide

ControlOMatic MegaChlor operating instructions

ControlOMatic

ControlOMatic MegaChlor operating instructions

Fahl LARYVOX STYLE Instructions for use

Fahl

Fahl LARYVOX STYLE Instructions for use

Waterdrop WD-WHF21-PG user manual

Waterdrop

Waterdrop WD-WHF21-PG user manual

EcoWater ERO-385 manual

EcoWater

EcoWater ERO-385 manual

FLI CFW-1-5 user guide

FLI

FLI CFW-1-5 user guide

Philips Micro Pure WP3811 user manual

Philips

Philips Micro Pure WP3811 user manual

ROSEDALE M-8 Installation, operation & maintenance manual

ROSEDALE

ROSEDALE M-8 Installation, operation & maintenance manual

Tersano iClean mini instructions

Tersano

Tersano iClean mini instructions

Glasco UV GUV C Classic series Operation & maintenance manual

Glasco UV

Glasco UV GUV C Classic series Operation & maintenance manual

Zenith GlobalPlus 800955NZ installation instructions

Zenith

Zenith GlobalPlus 800955NZ installation instructions

JRC NSVS1176 manual

JRC

JRC NSVS1176 manual

Kinetico MACH Series owner's manual

Kinetico

Kinetico MACH Series owner's manual

Burcam 700313 installation instructions

Burcam

Burcam 700313 installation instructions

GE GN1S15CBL (REV. 2) Owners and installation manual

GE

GE GN1S15CBL (REV. 2) Owners and installation manual

Interpet CF1 Instruction manual and set up guide

Interpet

Interpet CF1 Instruction manual and set up guide

Aqua Free Germlyser ENT Instructions for use

Aqua Free

Aqua Free Germlyser ENT Instructions for use

Premier Filter-Pure UF3 Installation, operation and maintenance manual

Premier

Premier Filter-Pure UF3 Installation, operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.