Antunes TAC-02 User manual

TAC-02 SYSTEM (P/N 9700906)
+1-877-392-7854 Page 1 of 2 P/N 1011030 Rev. B 05/17
TOOLS:
• Mounting Hardware (Not Provided)
• Drill with bits
• Tape Measure
• Pipe Wrenches
• Adjustable Wrenches
• Level
• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord
• Screwdriver (Flat Blade and Phillips)
• Two Gallon Bucket
• Fresh 6% unscented liquid chlorine bleach
PARTS INCLUDED:
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)
1 - Housing, Bowl, and Head (2180285)
1 - Wrench, Filter (2180244)
1 - Tee 3/4” NPT (2190184)
1 - Nipple 3/4” NPT x 1-1/2” Lg. (2070117)
1 - TAC-02 Cartridge Kit (7000716)
1 - Instruction Sheet (P/N 1011030)
CAUTION
Do NOT use this system with water that is microbiologi-
cally unsafe or of unknown quality without adequate dis-
infection installed before or after the system.
General
If you experience any problems with these instructions, or if
any parts are damaged or missing, contact Antunes Technical
Service at +1-877-392-7854 toll free.
The TAC System improves the quality of water by addressing
scale issues on hot water applications. It should be installed
upstream of equipment using hot water.
Equipment Setup
When installing the system, pay attention to the following guide-
lines:
• Do not install above electrical equipment.
• Allow space below the TAC Housing for TAC Cartridge
replacement.
PLUMBING
NOTE: This system is designed to be used on tap water not
to exceed 100°F (38°C) or 100 psig (690 kPa). The kit must
be connected to the COLD water line. Do NOT connect the
kit to the hot water line.
The TAC System has the following connections:
• Inlet 3/4” NPT
• Outlet 3/4” NPT
When making a plumbing connection to the System, use a
back-up wrench on the supporting plumbing. Always use a
quality, approved pipe sealant or thread seal tape on the pipe
threads. Be careful not to get the pipe sealant inside the pipe
when making connections.
Do NOT over tighten the connections. The use of plastic fittings
when connecting to the plastic head will reduce the possibility of
cracking the head due to over tightening.
If soldered plumbing is used, do NOT apply heat to, or near, the
Head. The use of union (O-ring seal) connections is highly
recommended for ease of installation and future servicing.
CAUTION
This equipment must be installed to comply with the
basic plumbing code of the Building Officials and Code
Administrators, Inc. (BOCA) and the Food Service
Sanitation Manual of the Food and Drug Administration
(FDA).
CAUTION
Water pressure must not exceed 100 psig. To reduce
water pressure, install a water pressure regulator and set
the water pressure to below 100 psig.
Head
Bracket
and
Screws (8)
Housing
Head
O-Ring
(incl. with Head)
TAC
Cartridge
Filter Wrench
Figure 1. TAC-02 System
ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
TAC-02 SYSTEM (P/N 9700906)
+1-877-392-7854 Page 2 of 2 P/N 1011030 Rev. B 05/17
INLET WATER PLUMBING
The plumbing leading to the TAC System must be flushed clear
of all debris before connecting to the inlet connection of a water
system. Hold a bucket at the inlet water line and slowly open
the inlet water valve. Allow the pipe to flush until all debris is
removed.
MOUNTING THE SYSTEM
Before mounting the TAC System, please consider the items
listed below:
• The Housing must be mounted with sufficient access for
element replacement. The Housing is 24 inches tall. An
additional 2 inches should be allowed below the bowl to
allow proper access when changing elements.
• The kit must be mounted with hardware capable of support-
ing 10 lbs or more of weight.
• The mounting bracket supplied with the system must be
mounted in the UP position (See Figure 2). The bracket
comes with short screws for attaching to the head and long
screws for attaching the bracket to the wall.
NOTE: Only the short screws should be used for mounting
the Head to the Bracket.
• The Head can be mounted with the inlet on the left or on
the right. When the inlet is on the left, the red pressure
relief button is on the left. Refer to Figure 2 for help in locat-
ing the Inlet and Outlet ports.
• The TAC System must be installed upstream of all equip-
ment using hot water.
• The inlet water should only be connected to the “INLET”
port on the Head. The filtered water should only be con-
nected to the “OUTLET” port on the Head. See Figure 2.
Attach the mounting bracket to the Head BEFORE attaching to
the wall.
ATTACHING TO THE INLET
Both the Inlet and Outlet connections have a 3/4” NPT female
thread. Be careful not to overtighten a fitting into the Head.
Plastic fittings are recommended for connecting to the Head.
Use a pipe thread sealant approved for use in drinking water
applications with plastic fittings.
Sanitizing the System and Lines
INLET
OUTLET
Red Pressure
Relief button
Attach Bracket to
Wall in this position
Figure 2. Mounting Bracket (Up Position ONLY)
CAUTION
Do NOT connect the Inlet water to the Outlet port on the
head.
The plumbing must be sanitized to eliminate possible contami-
nation that may have occurred during the installation process.
Liquid chlorine bleach (regular bleach, unscented 6% sodium
hypochlorite) can be used to sanitize the plumbing. The amount
of bleach to use depends on the system installed and the
amount of plumbing downstream of the TAC System. Generally
10 drops (one-half ml) of bleach is sufficient to sanitize the bowl
and associated plumbing.
NOTE: When sanitizing the TAC System, make sure the TAC
cartridge is not installed or is removed from the housing
before sanitizing.
CAUTION
Make sure the follow any handling or safety instructions
supplied with the bleach.
1. Direct the water line from the outlet of the Head to a
drain.
2. Unscrew the Housing counter clockwise to remove the
Housing from the Head.
3. Pour the liquid chlorine bleach into the bowl.
4. Screw the Housing (containing the bleach) into the Head.
Tighten the bowl until it stops. The Housing will come to a
hard stop at the end of the thread. Use the filter wrench if
necessary. Do not overtighten the housing.
5. Slowly turn on the water supply and pressurize the sys-
tem. Allow water to flow out of the Housing until the odor
of bleach is present.
6. Turn off the water supply and let the system stand without
water flow for at least 15 minutes to allow the bleach to
sanitize the pipes.
7. After 15 minutes without water flow, turn on the water
supply and flush until the presence of bleach is gone.
8. Shut off the water supply and depressurize the system.
NOTE: Refer to document 1011029, provided with this
system, for instructions on replacing and rinsing the TAC
Cartridge.
ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

This manual suits for next models

1

Other Antunes Water Filtration System manuals

Antunes VZN-420H User manual

Antunes

Antunes VZN-420H User manual

Antunes TAC-01 User manual

Antunes

Antunes TAC-01 User manual

Antunes VZN Series User manual

Antunes

Antunes VZN Series User manual

Antunes UFL-420 Series User manual

Antunes

Antunes UFL-420 Series User manual

Antunes VZN User manual

Antunes

Antunes VZN User manual

Antunes VZN-520H User manual

Antunes

Antunes VZN-520H User manual

Antunes AQ-RO-400-NT User manual

Antunes

Antunes AQ-RO-400-NT User manual

Antunes 9700901 User manual

Antunes

Antunes 9700901 User manual

Antunes UFL-510 User manual

Antunes

Antunes UFL-510 User manual

Antunes VZN-441VE User manual

Antunes

Antunes VZN-441VE User manual

Antunes WATER WRO-50-R User manual

Antunes

Antunes WATER WRO-50-R User manual

Antunes VZN-500 Series User manual

Antunes

Antunes VZN-500 Series User manual

Antunes VZN-421H User manual

Antunes

Antunes VZN-421H User manual

Antunes VZN-441VC User manual

Antunes

Antunes VZN-441VC User manual

Antunes 9700913 User manual

Antunes

Antunes 9700913 User manual

Antunes VZN-441VA User manual

Antunes

Antunes VZN-441VA User manual

Antunes DMS-100 User manual

Antunes

Antunes DMS-100 User manual

Antunes UF-216CC User manual

Antunes

Antunes UF-216CC User manual

Antunes VZN T5 Series User manual

Antunes

Antunes VZN T5 Series User manual

Antunes VZN-441 User manual

Antunes

Antunes VZN-441 User manual

Antunes UFL-410 Series User manual

Antunes

Antunes UFL-410 Series User manual

Antunes VZN-500 Series User manual

Antunes

Antunes VZN-500 Series User manual

Antunes VZN-411V User manual

Antunes

Antunes VZN-411V User manual

Popular Water Filtration System manuals by other brands

Austin Springs AS-WH-AST installation instructions

Austin Springs

Austin Springs AS-WH-AST installation instructions

Oase Filtral 2500 UVC operating instructions

Oase

Oase Filtral 2500 UVC operating instructions

Foma ML-C D1521Pi T instruction manual

Foma

Foma ML-C D1521Pi T instruction manual

EHEIM 2010 manual

EHEIM

EHEIM 2010 manual

Sera Pond fil bioactive user manual

Sera

Sera Pond fil bioactive user manual

WaterStep M-100 instruction manual

WaterStep

WaterStep M-100 instruction manual

US Water Systems Fusion Service manual

US Water Systems

US Water Systems Fusion Service manual

Watts Hydro-Safe Steam Max-S1 Installation, operation and maintenance manual

Watts

Watts Hydro-Safe Steam Max-S1 Installation, operation and maintenance manual

Sunshine Pool Products SPE installation instructions

Sunshine Pool Products

Sunshine Pool Products SPE installation instructions

Philips Pure Taste WP3861 manual

Philips

Philips Pure Taste WP3861 manual

Diamond Coral WATERBAR-S user manual

Diamond

Diamond Coral WATERBAR-S user manual

Festo 8079862 operating instructions

Festo

Festo 8079862 operating instructions

BWT Infinity A+AP Installation and operating manual

BWT

BWT Infinity A+AP Installation and operating manual

Watts Hydro-Safe Cold Bev Max-S2 Installation, operation and maintenance manual

Watts

Watts Hydro-Safe Cold Bev Max-S2 Installation, operation and maintenance manual

Ispring UVF55FS Installation and maintenance manual

Ispring

Ispring UVF55FS Installation and maintenance manual

Zodiac Nature 2 Express Instruction manual & warranty card

Zodiac

Zodiac Nature 2 Express Instruction manual & warranty card

Thinkwater PROfine SILVER DRINK KIT Installation and use

Thinkwater

Thinkwater PROfine SILVER DRINK KIT Installation and use

Sterilight S1Q-DWS Installation instructions & owner's manual

Sterilight

Sterilight S1Q-DWS Installation instructions & owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.