P/N 1011180 Rev. C 11/16 3
IMPORTANT SAFETY
INFORMATION
In addition to the warnings and cautions in
this manual, use the following guidelines to
safely operate the system:
yRead all instructions before using
equipment.
yInstall or locate the equipment only
for its intended use as described in
this manual.
yDo NOT use corrosive chemicals in
this equipment.
yDo NOT operate this equipment if it
has a damaged cord or plug; if it is
not working properly, or if it has been
damaged or dropped.
yThis equipment should be serviced
by qualied personnel only. Contact
A.J. Antunes & Co. for repair.
yDo NOT immerse cord or plug in
water.
yKeep cord away from heated surfaces.
yThis equipment should be supplied
with only cold water.
yFor installations in Massachusetts, the
Commonwealth of Massachusetts
Plumbing Code 248 CMR shall be
adhered to. The use of saddle valves
are not permitted. Please consult your
local plumber.
The following warnings and cautions appear
throughout this manual and should be care-
fully observed.
yUnplug the power cord before
performing any service or
maintenance on the unit.
yAll electrical connections must be in
accordance with local electrical codes
and any other applicable codes.
yWarning electrical shock hazard.
Failure to follow these instructions
could result in serious injury or death.
yDo NOT modify the power supply
cord plug. If it does not t the outlet,
have a proper outlet installed by a
qualied electrician.
yDo NOT use an extension cord with
this unit.
yIf the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent, or a similarly qualied
person.
yThis equipment is to be installed to
comply with the local plumbing code
and any other applicable code.
yWater pressure must not exceed
100 psig (690 kPa). To reduce water
pressure, install a water pressure
regulator and set to suit the
application.
yThe trans membrane pressure (inlet
pressure minus the permeate water
pressure) must not exceed 45 psi (310
kPa).
yA ground fault circuit interrupter
(GFCI) must be installed on the circuit
to this system.
yWhen installed on metallic plumbing,
a properly sized electrical bonding
jumper must be installed across the
inlet and outlet pipes serving this
unit.
Protect from becoming dry
If the membrane dries out, irreversible dam-
age to the Ultra Filter membrane may result.
Protect the lter from becoming dry by
keeping it wet and sealed at all times.
Protect from freezing
If the Ultra Filter membrane freezes during
operation or storage, irreversible damage
to the membrane and brittle cracking of the
cartridge or housing may result.
Protect from direct sunlight or other UV
sources
Avoid long-term exposure to direct sunlight
or other UV sources. The Ultra Filter should
be stored in a dark location.
Protect from high temperatures or
abrupt variation in temperature
The maximum operating temperature is
104°F (40°C). Avoid abrupt variations in tem-
perature. Any temperature variation should
be made slowly.
Protect from rough handling or dropping
Mechanical damage, external breakage,
and/or internal breakage of the lter can
result if the system is dropped or bumped.
Handle with care at all times during trans-
portation and installation.
Protect from organic solvents and con-
centrated acids
Prevent any and all contact of the mem-
brane with strong solvents, solvents
containing chlorine, or concentrated acids.
Do NOT use strong solvents or concen-
trated acids on any plastic parts of the
lter system. Examples of some solvents to
avoid: acetone, methyl acetate (nail polish
remover); hexane (spot removers); turpen-
tine, toluene (paint thinners); dry cleaning
solutions, insecticides.
Protect from abrasive material
The membranes must be protected from
abrasive materials like shavings left in a
pipe. Abrasive materials in contact with the
membrane can cause irreversible damage
to the membrane. All pipes must be ushed
clean before installing the lter. All plastic
parts of the lter system must be protected
from sharp objects like knives, sand paper,
or other tools. Cutting or nicking a plastic
part can weaken it and cause a leak. Do NOT
use abrasive cleansers on any plastic parts.
Protect from water hammer
The system must be protected from shock,
pressure surges, or pulsation that may occur
inside water pipes. Water hammer occurs in
pipes when a valve or faucet shuts quickly.
Install a water hammer arrestor (pressure
vessel containing compressed air separated
from the water by a diaphragm) to reduce
pressure shock.