manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aprilaire
  6. •
  7. Air Cleaner
  8. •
  9. Aprilaire 1210 User manual

Aprilaire 1210 User manual

Other manuals for 1210

1

This manual suits for next models

8

Other Aprilaire Air Cleaner manuals

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire 1310 User manual

Aprilaire

Aprilaire 1310 User manual

Aprilaire 1510 User manual

Aprilaire

Aprilaire 1510 User manual

Aprilaire 3210 User manual

Aprilaire

Aprilaire 3210 User manual

Aprilaire 1625FG User manual

Aprilaire

Aprilaire 1625FG User manual

Aprilaire 2275 User manual

Aprilaire

Aprilaire 2275 User manual

Aprilaire ALLERGY 9550 User manual

Aprilaire

Aprilaire ALLERGY 9550 User manual

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire 1510 User manual

Aprilaire

Aprilaire 1510 User manual

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire 1610 User manual

Aprilaire

Aprilaire 1610 User manual

Aprilaire 2250 & 2400 User manual

Aprilaire

Aprilaire 2250 & 2400 User manual

Aprilaire 1610 User manual

Aprilaire

Aprilaire 1610 User manual

Aprilaire 1952 Setup guide

Aprilaire

Aprilaire 1952 Setup guide

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire ALLERGY + PET9550 User manual

Aprilaire

Aprilaire ALLERGY + PET9550 User manual

Aprilaire 2140 MEDIA User manual

Aprilaire

Aprilaire 2140 MEDIA User manual

Aprilaire 5000 Setup guide

Aprilaire

Aprilaire 5000 Setup guide

Aprilaire 2250 User manual

Aprilaire

Aprilaire 2250 User manual

Aprilaire 4200 User manual

Aprilaire

Aprilaire 4200 User manual

Aprilaire 5000 User manual

Aprilaire

Aprilaire 5000 User manual

Aprilaire 2200 Setup guide

Aprilaire

Aprilaire 2200 Setup guide

Aprilaire 4200 User manual

Aprilaire

Aprilaire 4200 User manual

Popular Air Cleaner manuals by other brands

Steel City 65120 user manual

Steel City

Steel City 65120 user manual

CFM CX1000 user guide

CFM

CFM CX1000 user guide

Amana Media MAC1 Series installation instructions

Amana

Amana Media MAC1 Series installation instructions

Glaziar PUR50 Instructions for use

Glaziar

Glaziar PUR50 Instructions for use

Panasonic F-PXR40H operating instructions

Panasonic

Panasonic F-PXR40H operating instructions

Lightair IonFlow 50 manual

Lightair

Lightair IonFlow 50 manual

Lennox Healthy Climate PMAC-12C brochure

Lennox

Lennox Healthy Climate PMAC-12C brochure

IKEA UPPÅTVIND quick start guide

IKEA

IKEA UPPÅTVIND quick start guide

Nash AP-1 PureSmart instruction manual

Nash

Nash AP-1 PureSmart instruction manual

Aktobis WDH-220B manual

Aktobis

Aktobis WDH-220B manual

Honeywell HHT-013-HD user guide

Honeywell

Honeywell HHT-013-HD user guide

LG PH-U450 Series owner's manual

LG

LG PH-U450 Series owner's manual

Sharp FU-40SE Operation manual

Sharp

Sharp FU-40SE Operation manual

Philips AC2721 user manual

Philips

Philips AC2721 user manual

Filtrete FAP-T02 manual

Filtrete

Filtrete FAP-T02 manual

DeLonghi DDSX 220WFA manual

DeLonghi

DeLonghi DDSX 220WFA manual

TruSens Z-2000 manual

TruSens

TruSens Z-2000 manual

Motorola MBP87SN quick start guide

Motorola

Motorola MBP87SN quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Media Air Cleaners
Installation Instructions
1. High voltage may cause serious
injury from electrical shock.
Disconnect power to the
furnace/air handler before
starting installation.
2. Sharp edges may cause injury
from cuts. Use care when cutting
and handling sheet metal.
WARNING
1. To prevent component failure, do not install the air cleaner on the warm
air supply or in an area where the temperature may exceed 140°F. This
may include areas above heat exchangers in downflow furnaces or above
exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning
professional. Read instructions thoroughly before beginning installation.
3. Do not install air cleaner downstream of a UV light. UV lamps will cause
degradation of the filtering media.
CAUTION
SPECIFICATIONS
Airflow Capacity: up to 2000 CFM maximum
Replacement Media:
1210, 2210, 3210: Model 210 or 213 with SelfSeal™
1310, 2310, 3210: Model 310 or 313 with SelfSeal™
1410, 2410, 3410: Model 410 or 413 with SelfSeal™
Max. Equipment Weight:
Cabinet will support 400 lb. static load
Air Cleaner Operating Environment:
Temperature: 0°F – 140°F
Humidity: 0-90% non-condensing
DIMENSIONS
TABLE 1 – Dimensions (inches)
Model A B C D E F G H
1210, 2210, 3210 19-3/4 25-3/8 21-3/16 6-3/4 27-3/8 21-3/16 19-3/4 22-1/16
1310, 2310, 3310 18-1/16 20-1/16 15-7/8 6-3/4 22-1/16 15-7/8 18-1/16 20-3/8
1410, 2410, 3410 15-7/16 28-1/16 23-7/8 6-3/4 30-1/16 23-7/8 15-7/16 17-3/4
A
B
without door
C
D
E
with door
F
G H
90-1333
INSTALL THE AIR CLEANER CABINET
1. Leave sufficient space in front of the air cleaner for the removal of
the filtering media (see Figure 1).
2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. UV lamps
will cause degradation of the filtering media.
3. Figures 2-4 show typical applications.
LOCATING THE AIR CLEANER
29"
FIGURE 1 – Filtering Media Clearance
90-1374
Airflow AirflowAirflow
30°max
45° max
FIGURE 4 – Highboy Upflow Installation
90-1320
Airflow
FIGURE 2 – Horizontal Installation
90-1319
Airflow Airflow
FIGURE 3 – Highboy Installation
90-1318
2
2. Remove the air cleaner door from the outer housing and pull out the filtering media.
3. If replacing an existing filter, remove the filter and thoroughly clean the blower
compartment.
4. Use screws (field supplied) to mount the outer housing to the furnace/air handler.
There is no inlet or outlet side on the outer housing (the outer housing can be mounted
on the left or right side of the furnace/air handler).
NOTE FOR UPFLOW INSTALLATIONS: Provide support under the outer housing to ensure the quality of the seals (see Figure 5).
5. Mount the return ductwork to the outer housing.
6. Seal all connections using mastic, foil tape or silicone based caulk.
7. Install the filtering media (see Figure 6).
8. Install the door.
9. Reconnect power to the furnace or air handler at the electrical
service panel.
INSTALLATION
FIGURE 5
90-1374
120 Volts may cause serious injury from electrical shock. Disconnect
power to the furnace/air handler before starting installation. Leave power
disconnected until installation is completed.
WARNING
1. Disconnect power to the furnace or air handler at the electrical service panel.
FIGURE 6
Expand clean filter.
Align filter in top and bottom rails
and slide into place. Reinstall door.
Install filter with Air Flow pointing
toward Furnace or Air Handler.
3
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com
10009757 1.12
B2701229A
Printed in U.S.A.
© 2012 Aprilaire – A division of Research Products Corporation