APW Wyott DI-1014 User manual

Phone: +1
Fax: +1 (307) 637-8071
Toll Free: +1 (800) 752-0863
Website: www.apwwyott.com
(307) 634-5801
INSTALLATION
AND
OPERATING
INSTRUCTIONS
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 88595/88632 9/05
1
APW WYOTT
P.O. Box 1829
Cheyenne, WY 82003
This equipment has been engineered to provide you with year-round dependable service when used
according to the instructions in this manual and standard commercial kitchen practices.
R
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment. For
Warranty Service and/orParts, thisinformation is required.
ModelNumber Serial Number DatePurchased
DROP-IN RACK DISPENSERS
Models:
DI-1014
DI-1020
DI-1418
DI-1216
DI-1620
DI-1622
DI-2020

2
GENERAL INFORMATION
Removal of Cables
Installing NewCables
A. Turnunitupsidedown onflat surface.
B. With a box end or hex socket wrench, loosen the two hex head bolts to relax the strap clamps
holding the power shaft. The power shaft will turn about one revolution when free of the
clamps-keep one hand on the power shaft while loosening the clamps so it will not spin
suddenly and cause to "spill"off from the power drums.
C. With the aid of another person, unwind the cables from the power drums by pulling the
cables up evenly (allowing the power shaft to turn) until the cables are completely off the
drums. Do not allow the cables to "spill" off the power drums, as this puts an undesirable
twist in the cables.
D. With a Phillips head screwdriver, remove screwAand screw B from the power drum and put
in a safe place. Do on other side.
E. With a box end or hex socket wrench, loosen (do not take apart) the carrier pulleys and tape
lockwashers oneachside.
F. With needle nose pliers, pull out the ends of the cable, foundin the center of the power drum,
about 6" towards you. In back of the two cable ends, find the power drum key. With the
needle nose pliers, work the key up and out. Remove the cable through the hole the key
came out of. Remove the cable from the carrier pulleys and tape lock washers; discard
cable.Re peat onthe otherside.
A. Center 11 ft. cable between two bottom lock washers. Thread through lock washers and
through the guides just above. Bring cabletowards the center of the unit, threading between
carrier pulley and carrier cable retainer. Tighten hex lock nut on carrier pulley as the retainer
is up against the metal flange as far as it can go. Repeat on the otherside.
B. Position the power shaft with the hole straight up and with the arrow pointing in the direction
of the limit cable.Align the hole on the powerdrum with the hole on the power shaft, showing
heads of screws towardsyou.
C. Place ends of the cable in the hole and pull on the ends with a pair of needle nose pliers,
bringing the ends out about 6". Do not twist the cables; make sure the right cable is on the
right side and the left cable is on the left side.
D. Take the power drum key and place in the hole in back of the cables. With a 1/4" punch
(screwdriver will do) and a hammer, drive the key down into place making sure it has entered
throughboth holes.
E. Pull cables up as far as they will go, and replace screwAin betweenthe right and left cables.
Pull the cables in the direction of the arrowand replace screw B over the cables.
F. Repeat steps B through E on the other side.
G. Hold the cables up, to hold them taut. There will be two loops on each side-use your thumb
and index finger to supportthe loops on eachside.
H. Have another person wind up the power shaft in the direction of the arrow stamped on the
power shaft, until all of the cable is wound back into the power drums.
I. Once the cable is wound tight, continue to turn the power shaft an additional 3/4 to one turn
(for head load required to support the weight of the mechanism), and tighten the clamp bolt
to prevent the tube from turning.
J. Align the grooveon the tape lock washers with the cable.Tighten down the tape lock washer
to prevent slippage of the cable in future use.
K. Place the unit back in the counter and depress the platform fully several times to allow the
cables to attain their natural position on the power drums.
L. If the platform is level, the cable replacement is complete. If the platform is uneven, loosen
the four tape lock washers and allow the cables to shift into a balanced tension. To help
attain the condition, grip both power drums and apply torque in the direction of rotation that
will put additional tension on the cables.Tighten the four tape lockwashers and re-install the
unit in the counter.

3
CABLE REPLACEMENT KIT
Materials Furnished
Tools Needed
2 - (Two) Replacement Cables
2 - (Two) Power Drum Keys
Needle Nose Pliers
Hammer
1/4: Punch (Screwdriver will do)
Phillips Head No.3 Screwdriver
Box End or Hex Socket Wrenches
Tape Lockwasher
(Cable Clamp)
Flange
Weldment
Cable
Carrier
Weldment
Carrier
Pulley
Power
Drum
Screw “A”
Screw “B”
Shaft
Clamp
Limit
Cable
Carrier Pulley
Retainer
Power Shaft
Adjustingthe Unit
A. Turn unit upside down on a flat surface.
B. With a socket or box end wrench,loosen the two hex head bolts
to relax the strap clamps holding the power shaft. The power shaft will turn about one
revolution when free of the clamps keep one hand on the power shaft while loosening the
clamps so it will not spin suddenly and cause thecable to "spill" off from the power drums.
C. With the aid of another person, unwind the cables from the power drums by pulling the
cables up evenly (allowing the power shaft to turn) until the cables are completely off the
drums. Do not allow the cables to "spill" off the power drums, as this puts an undesirable
twist in the cables.
D. Remove the eight screws from each power drum. If the load rate is to be increased, re-install
the screws into a smaller circle of holes. If the load is to be decreased, re-install the screws
into the larger circle of holes. Be certain that the same circle of holes is used on both of the
power drums. Be certain that the cable emerges between the same relative screw locations
onbothpower drums.
E. Loosen the cable clamphex nuts at the fourcorners under the flange.
F. Hold the cables up to hold them taut. There will be two loops on each side-use your thumb
and index finger to supportthe loops on eachside.
G. Have another person wind up the torque tube in the direction of the arrow stamped on the
power shaft, until all of the cable is wound back into the power drums.
H. Once the cable is wound tight, continue to turn the power shaft an additional 3/4 to one turn
(for head load required to support the weightof the mechanism), and tighten the clamp bolts
to prevent the tube from turning.
I. Tighten-the cable clamp hex nuts at the four corners under the flange.
J. Place the unit back in the counter and depress the platform fully several times to allow the
cables to attain their natural position on the power drums.

4
1
2
4
5
6
7
8
9
3
ITEM DESCRIPTION DI-1014 DI-1020 DI-1418 DI-1620 DI-1622 DI-2020 DI-1216
1 Flange Weldment 202152 202151 202150 202149 202148 202147 21103600
2 Cable 30175 30175 30175 30175 30175 30175 30175
3 Carrier Weldment 202137 202136 202135 202133 202134 202132 21103200
4 Carrier Pulley 86020 86020 86020 86020 86020 86020 86020
5 Power Drum L.H. 202356 202356 202356 202356 202356 202356 20299700
R.H. 202355 202355 202355 202355 202355 202355 20299700
6 Tube Clamp 202145 202145 202145 202145 202145 202145 202145
7 Cable Retainer 202357 202357 202357 202357 202357 202357 202357
8 Power Shaft 202168 202164 202165 202164 202166 202164 21103900
9 Tape Lock Washer 206535 206535 206535 206535 206535 206535 206535
*10 Limit Cable 30177 30177 30177 30177 30177 30177 30177
*11 Cable Repl. Kit 206853 206853 206853 206853 206853 206853 206853
*12 Power Drum Key 202358 202358 202358 202358 202358 202358 20299500
*13 Pulley Bushing 89666 89666 89666 89666 89666 89666 89666
*14 Cable Guide 86028 86028 86028 86028 86028 86028 86028
*15 Limit Cable Bushing 86029 86029 86029 86029 86029 86029 86029
Power Drum
*NOT SHOWN
PARTS LIST & EXPLODED VIEW
57 SERIES IN-COUNTER DROP-IN LOWERATOR

NOTES:
5

NOTES:
6

7
APW WYOTT EQUIPMENT LIMITED WARRANTY
APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the
following conditions:
This warranty applies to the original owner only and is not assignable.
Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of
APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency. APW Wyott will only be
responsible for charges incurred or service performed by its Authorized Service Agencies. The use of other than APW Wyott
Authorized Service Agencies will void this warranty and APWWyott will not be responsible for such work or any charges associated
with same. The closestAPW WyottAuthorized ServiceAgent must be used.
This warranty covers products shipped into the 48 contiguous United States, Hawaii, metropolitan areas ofAlaska and Canada. There
will be no labor coverage for equipment located on any island not connected by roadway to the mainland.
One year for parts and one year for labor, effective from the date of purchase by the original owner. The Authorized Service Agency
may, at their option, require proof of purchase. Parts replaced under this warranty are warranted for the un-expired portion of the
original product warranty only.
Models GCB, GCRB, GF, GGM, GGT, CHP-H, EF, EG, EHP. Three (3) Year Warranty on all
component parts, except switches and thermostats. (2 additional years on parts only. No labor on second or third year.)
In all cases, parts covered by extended warranty will be shipped FOB the factory after the first year.
Equipment weighing over 70 pounds or permanently installed will be serviced on-site as per the terms of this warranty. Equipment
weighing 70 pounds or under, and which is not permanently installed, i.e. with cord and plug, is considered portable and is subject to
the following warranty handling limitations. If portable equipment fails to operate in its intended manner on the first day of
connection, or use, atAPWWyott's option or itsAuthorized Service Agency, it will be serviced on site or replaced.
From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott
Authorized ServiceAgency for in-warranty repairs. No mileage or travel charges are allowed on portable units after the first day of use.
If the customer wants on-site service, they may receive same by paying the travel and mileage charges. Exceptions to this rule: (1)
countertop warmers and cookers, which are covered under the Enhanced Warranty Program, and (2) toasters or rollergrills which have
in store service.
The following conditions are not covered by warranty:
*Equipment failure relating to improper installation, improper utility connection or supply and problems due to
ventilation.
*Equipment that has not been properly maintained, calibration of controls, adjustments, damage from improper cleaning
and water damage to controls.
*Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication, neglect,
abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, riot or act of god.
*Equipment that has themodel number orserial number removed oraltered.
If the equipment has been changed, altered, modified or repaired by other than an Authorized Service Agency during or after the
warranty period, then the manufacturer shall not be liable for any damages to any person or to any property, which may result from the
use of the equipment thereafter.
This warranty does not cover services performed at overtime or premium labor rates. Should service be required at times which
normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and such
premium rates.APWWyottdoes not assume anyliability for extended delays inreplacing orrepairing any itemsbeyond itscontrol.
In all cases, the use of other thanAPW WyottAuthorized OEM Replacement Parts will void this warranty.
This equipment is intended for commercial use only.Warranty is void if equipment is installed in other than commercial application.
Water supply intended for a unit that has in excess of 3.0 grains of hardness per gallon (GPG) must be treated or softened before
being used. Water containing over 3.0 GPG will decrease the efficiency and reduce the operation life of the unit.
9/05
Warranty coverage on products used outside the 48 contiguous United States, Hawaii, and metropolitan areas of Alaska and Canada
may vary. Contact theinternational APWWyott distributor, dealer, or service agency fordetails.
Models FD, FDL, FDD, FDDL. Two (2)Year Warranty on element only. No labor second year.
Time Period
Exceptions*Gas/Electric Cookline:
*Glass Windows, Doors, Seals, Rubber Seals, Light Bulbs:
Portable Carry In Products
Exclusions
Water Quality Requirements
Note: Product failure caused by liming or sediment buildup is not covered under warranty.
THE FOREGOING WARRANTY IS IN LIEU OFANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSES
AND CONSTITUTES THE ENTIRE LIABILITY OFAPW WYOTT. IN NO EVENT DOES THE LIMITED WARRANTY
EXTEND BEYOND THE TERMS STATED HEREIN.
*BroilerBriquettes,
*Heat Strips: Rock Grates, Cooking Grates, BurnerShields,Fireboxes:
90DayMaterialOnly.NoLabor.
90 Day Material Only. No Labor.

Phone: +1
Fax: +1 (307) 637-8071
Toll Free: +1 (800) 752-0863
Website: www.apwwyott.com
(307) 634-5801
APW WYOTT
P.O. Box 1829
Cheyenne, WY 82003
R
8
This manual suits for next models
6
Table of contents
Other APW Wyott Dispenser manuals

APW Wyott
APW Wyott Lowerator HMCTRS-2020-5 User manual

APW Wyott
APW Wyott DAO User manual

APW Wyott
APW Wyott HML2-10 User manual

APW Wyott
APW Wyott CCW MK VII, RCCW MK VII, LCCW MK VII, RLCCW MK... User manual

APW Wyott
APW Wyott HL-12A User manual

APW Wyott
APW Wyott Lowerator L-10 User manual

APW Wyott
APW Wyott Lowerator HMCTR-1020 User manual

APW Wyott
APW Wyott HTL2-10 User manual

APW Wyott
APW Wyott CSC-3 User manual