ARAG orion 462A Series Quick start guide

ELECTROMAGNETIC FLOWMETER
02
INSTALLATION, USE AND MAINTENANCE
462XAXXXXXX

This manual is an integral part of the equipment to which it refers and must accompany the equipment in
case of sale or change of ownership. Keep it for future reference; ARAG reserves the right to modify the
specications and instructions regarding the product at any time and without prior notice.
•LEGEND SYMBOLS
=Generic danger
=Warning
CONTENTS
Legend symbols...............................................................................................................2
1 Product description .........................................................................................................3
1.1 Intended use............................................................................................................3
2 Installation........................................................................................................................3
2.1 Dimensions (mm)..................................................................................................4-5
2.2 Assembly .................................................................................................................6
2.3 Electric connections.................................................................................................7
2.4 Hydraulic connections..............................................................................................7
2.4.1 Hydraulic connections for control units .................................................................8
3 Preliminary setup for use................................................................................................9
4 Use ....................................................................................................................................9
5 Maintenance ................................................................................................................... 10
5.1 Troubleshooting ..................................................................................................... 10
6 Technical data ................................................................................................................ 10
7 Guarantee terms.............................................................................................................12
8 Disposal at the end of service ......................................................................................12

3
1 PRODUCT DESCRIPTION
The Orion electromagnetic owmeter is a device that enables measurement of the quantity of liquid
passing through it.
Using a principle of electromagnetic measurement (there are no moving mechanical parts inside
it), the owmeter outputs a signal to the computer proportional to the liquid ow that goes trough
it; Orion displays the owrate calculated according to the data received from the owmeter and the
value of the owmeter constant previously set.
1.1 Intended use
This device is designed to work on agricultural machinery for crop spraying applications.
The machine is designed and built in compliance with EN ISO 14982 standard (Electro-
magnetic compatibility - Forestry and farming machines), harmonized with 2004/108/EC
Directive.
The owmeter must not be used to measure the passage of hydrocarbons, ammable,
explosive or toxic liquids. The owmeter is not suitable for contact with liquids for human
consumption. Use for sales transactions is not allowed.
2 INSTALLATION
Install the owmeter at least 20 cm from the elements that could cause turbulence inside the tubes
(valves, bends, constrictions, etc.).
The owmeter can be installed in a horizontal or vertical position.
CAUTION:
For proper sealing of the owmeter, use ARAG assembly kit ONLY (Ref. ARAG General
catalogue - Accessories for series 463/473 modular valves).
ARAG is not liable for damage to the system, persons, animals or things caused by the use
of material other than specied.
CONTINUES
Fig. 1

4
2.1 Dimensions (mm)
L
A
H
DN
X
X
CODE DN A H L X ange
4621AAG0000 4 81 90 114 41
463
863
4621AA00000 5 81 90 114 41
4621AA10000 7 81 90 114 41
4621AA20000 10 81 90 114 41
4621AA30000 14 81 90 114 41
4621AA40000 18,5 81 90 114 41
4622AA40000 18,5 81 90 114 45
473
873
4622AA50000 28 81 90 114 45
4622AA60000 28 81 90 114 45
Fig. 2
Tab. 1

5
Dimensions (mm)
A
DN
L
F
H
CODE DN A F H L
4621AAG1313 4 81 G 3/4 90 185
4621AAG3333 4 81 G 3/4 90 184
4621AA01313 5 81 G 3/4 90 185
4621AA03333 5 81 G 3/4 90 184
4621AA11313 7 81 G 3/4 90 185
4621AA13333 7 81 G 3/4 90 184
4621AA21313 10 81 G 3/4 90 185
4621AA23333 10 81 G 3/4 90 184
4621AA31414 14 81 G1 90 185
4621AA33434 14 81 G1 90 184
4621AA41414 18,5 81 G1 90 185
4621AA43434 18,5 81 G1 90 184
4621AA41515 18,5 81 G1 1/4 90 189
4622AA51515 28 81 G1 1/4 90 191
4622AA51616 28 81 G1 1/2 90 199
4622AA61616 28 81 G1 1/2 90 199
4622AA61717 28 81 G2 90 234
Tab. 2
Fig. 3

6
2.2 Assembly
To ensure trouble-free operation, comply with the indicated installation layout (Fig. 4a and Fig. 4b);
NEVER lay cable upward.
HORIZONTAL ASSEMBLY
OK
OK
VERTICAL ASSEMBLY
- Comply with the correct uid inlet-outlet direction, as indicated by the arrow printed on the
owmeter body (Fig. 5).
IN
OUT IN OUT
Use inlet and outlet pipes of the same diameter as the internal passages of the owmeter;
for any reference, see tables 7a-7b (Chap. 6 - Technical data).
Fig. 4a
Fig. 4b
Fig. 3

7
2.3 Electric connections
The Orion owmeter has been designed to be connected to ARAG devices (computers, screens,
displays) but can also be connected to equipment made by other manufacturers as long as they
are designed for owmeters of this typology.
ARAG is not liable for damage to the system, persons, animals or things caused by
incorrect or inadequate installation of the owmeter.
In the event of damage to the owmeter, caused by incorrect or unsuitable assembly,
any form of guarantee is automatically rendered null and void.
The connections of the Orion owmeter on devices not provided by ARAG are indicated in tables
3a and 3b.
There are two different types of owmeter connectors:
STANDARD CONNECTOR (ORION Code 462xAAxxxxx)
Colour Position Connection
Black 1GND
Red 2+12 VDC
Green 3Signal
(square wave)
DEUTSCH®CONNECTOR (ORION Code 4622AB61717)
Colour Position Connection
Green 1Signal
(square wave)
Black 2GND
Red 3+12 VDC
2.4 Hydraulic connections
For connection to the system, use appropriate ttings (Ref. ARAG General catalogue).
Avoid bends and constrictions before connections and on tubes.
Regarding connections, use tubes and ttings properly sized for the operating pressure of
the system.
The tightening of hose tails should be made with special metal clamps ensuring perfect
sealing even at high pressures.
The connection by means of threaded ttings should be done taking operating pressure
into account.
CAUTION: For the implementation on already operating systems it is necessary to
follow all safety rules described herein. System assembly and start-up must be carried out
by expert personnel according to the safety rules so as to ensure the same safety level of
the system the owmeter is going to be installed in.
Fig. 6a
Tab. 3a
Fig. 6b
Tab. 3b

8
2.4.1 Hydraulic connections for control units
Flowmeters with mounting ange 463/473 must be installed to specic control units
(Ref. to ARAG General catalogue).
If you need to install the owmeter to an existing control unit that had no owmeter,
consider that you shall order some new linkages to allow for assembly recomposi-
tion after installation of the owmeter (Ref. to ARAG General catalogue, Control units
section, Assembly Kit).
CAUTION: BEFORE ASSEMBLING THE FLOWMETER TO AN EXISTING UNIT, MAKE
SURE THAT THE OPERATING PRESSURE IS SUITABLE FOR THE CONTROL UNIT.
ARAG shall not be held liable for any and all damage to equipment, persons, animals
or things arising out of the failure to abide by the above instructions.
Remember to duly position any seals and O-Rings in their seats on anged cou-
plings.
Note: in the control units with standard conguration, the owmeter is usually as-
sembled between the control valve and the section valves unit. This does not mean
that the owmeter can not be installed at any other position; just consider that if
installed in different positions, the owmeter will read different values according to
the connected components.
It is recommended to lter the uid.
In order to obtain a correct reading, contact a dealer or installer that can give you
advice on how to correctly position the owmeter inside the control unit.
Fig. 7

9
3 PRELIMINARY SETUP FOR USE
Set owmeter constant (B, Fig. 8) on the computer connected to Orion owmeter: refer to the label
on the body (A, Fig. 8) and tables 7a-7b - Chap. 6 "Technical data".
For further information regarding how to set the constant, consult the use and maintenance
manual of the computer being used.
4 USE
When using the system, the owmeter sends impulses to the computer, which, according
to the constant value previously set, indicates the instant ow.
Orion owmeter can only detect conductive uids with a conductivity equal to 50 µS/cm or
higher (Ref.Tab. 5 - Chap. 6).
- Do not aim pressurised water onto the equipment.
- Respect the device’s rated power requirement (12 Vdc).
- If arc welding is required, ensure that owmeter power is off and disconnect the power
cables, if necessary.
- Use the owmeter only within the ow limits given in the “Technical data” table. Outside
these limits, the owmeter could give incorrect data and therefore lead the operator or the
automatic system to make errors.
ARAG cannot be held responsible for damage caused to persons, animals or things by
incorrect or unsuitable use of the owmeter or its parts.
Fig. 8

10
5 MAINTENANCE
- After every spraying operation, ush the pipe with clean water.
- In case of malfunction, and at any rate at the end of every season, clean the owmeter pipe with
a special detergent.
- Do not use metal or abrasive objects for cleaning the duct.
- Do not use solvents or petrol for cleaning the external parts of the device.
5.1 Troubleshooting
FAULT CAUSE REMEDY
The owmeter does not read any
value No power supply • Check the owmeter wiring.
The value read by the owmeter is
not linear or stable
Presence of turbulence or air in the
circuit • Check the circuit.
Tab. 4
6 TECHNICAL DATA
Description Orion
Power supply 11 ÷ 14,5 Vdc
Max. absorption 300 mA
Min. liquid conductivity 50 µS/cm
Working temperature 0 °C ÷ 60 °C
+32 °F ÷ +140 °F
Storage temperature -20 °C ÷ 60 °C
-4 °F ÷ +140 °F
Dimensions (mm) 100x200x126 / 105x114x126 (depending on the type)
Weight 886 ÷ 1650 g (depending on the type)
Tab. 5
CONTINUES

11
Model* Max. pressure
(BAR) Material
4621AAx0000 40
Nylon / Brass / Polypropylene /
Stainless Steel Inox
4621AAx3x3x 40
4621AAx4x4x 40
Others 20
Tab. 6
*= "x" means all possible variations for that position.
Internal
passages
(Ø mm)
Pulses
For valves
CODE l/min. US GPM P max
(BAR)
P max
(PSI) pls/l pls/
US GAL
4621AAG0000 0,3 ÷ 6 0,08 ÷ 1,6 40 580 4 6000 22710
463 series
4621AA00000 0,5 ÷ 10 0,13 ÷ 2,6 40 580 5 6000 22710
4621AA10000 1 ÷ 20 0,3 ÷ 5 40 580 7 3000 11355
4621AA20000 2,5 ÷ 50 0,6 ÷ 13 40 580 10 1200 4542
4621AA30000 5 ÷ 100 1,3 ÷ 26 40 580 14 600 2271
4621AA40000 10 ÷ 200 2,6 ÷ 53 40 580 18,5 300 113 5
4622AA40000 10 ÷ 200 2,6 ÷ 53 20 290 18,5 300 113 5
473 series4622AA50000 20 ÷ 400 5 ÷ 106 20 290 28 150 568
4622AA60000 30 ÷ 600 8 ÷ 158 20 290 28 100 378
Tab. 7a
F
(BSP)
Internal
passages
(Ø mm)
Pulses
CODE l/min. US GPM P max
(BAR)
P max
(PSI) pls/l pls/
US GAL
4621AAG1313 0,3 ÷ 6 0,08 ÷ 1,6 20 290 G 3/4 4 6000 22710
4621AAG3333 0,3 ÷ 6 0,08 ÷ 1,6 40 580 G 3/4 4 6000 22710
4621AA01313 0,5 ÷ 10 0,13 ÷ 2,6 20 290 G 3/4 5 6000 22710
4621AA03333 0,5 ÷ 10 0,13 ÷ 2,6 40 580 G 3/4 5 6000 22710
4621AA11313 1 ÷ 20 0,3 ÷ 5 20 290 G 3/4 7 3000 11355
4621AA13333 1 ÷ 20 0,3 ÷ 5 40 580 G 3/4 7 3000 11355
4621AA21313 2,5 ÷ 50 0,6 ÷ 13 20 290 G 3/4 10 1200 4542
4621AA23333 2,5 ÷ 50 0,6 ÷ 13 40 580 G 3/4 10 1200 4542
4621AA31414 5 ÷ 100 1,3 ÷ 26 20 290 G 1 14 600 2271
4621AA33434 5 ÷ 100 1,3 ÷ 26 40 580 G 1 14 600 2271
4621AA41414 10 ÷ 200 2,6 ÷ 53 20 290 G 1 18,5 300 113 5
4621AA43434 10 ÷ 200 2,6 ÷ 53 40 580 G 1 18,5 300 113 5
4621AA41515 10 ÷ 200 2,6 ÷ 53 20 290 G 1 1/4 18,5 300 1135
4622AA51515 20 ÷ 400 5 ÷ 106 20 290 G 1 1/4 28 150 568
4622AA51616 20 ÷ 400 5 ÷ 106 20 290 G 1 1/2 28 150 568
4622AA61616 30 ÷ 600 8 ÷ 158 20 290 G 1 1/2 28 100 378
4622Ax61717 30 ÷ 600 8 ÷ 158 20 290 G 2 28 100 378
Tab. 7b

12
7 GUARANTEE TERMS
1. ARAG s.r.l. guarantees this apparatus for a period of 360 day (1 year) from the date of sale
to the client user (date of the goods delivery note). The components of the apparatus, that
in the unappealable opinion of ARAG are faulty due to an original defect in the material or
production process, will be repaired or replaced free of charge at the nearest Assistance
Centre operating at the moment the request for intervention is made.
The following costs are excluded:
- disassembly and reassembly of the apparatus from the original system;
- transport of the apparatus to the Assistance Centre.
2. The following are not covered by the guarantee:
- damage caused by transport (scratches, dints and similar);
- damage due to incorrect installation or to faults originating from insufficient or inadequate
characteristics of the electrical system, or to alterations resulting from environmental, cli-
matic or other conditions;
- damage due to the use of unsuitable chemical products, for spraying, watering, weedkill-
ing or any other crop treatment, that may damage the apparatus;
- malfunctioning caused by negligence, mishandling, lack of know how, repairs or modica-
tions carried out by unauthorised personnel;
- incorrect installation and regulation;
- damage or malfunction caused by the lack of ordinary maintenance, such as cleaning of
lters, nozzles, etc.;
- anything that can be considered to be normal wear and tear.
3. Repairing the apparatus will be carried out within time limits compatible with the organisa-
tional needs of the Assistance Centre.
No guarantee conditions will be recognised for those units or components that have not
been previously washed and cleaned to remove residue of the products used.
4. Repairs carried out under guarantee are guaranteed for one year (360 days) from the
replacement or repair date.
5. ARAG will not recognise any further expressed or intended guarantees, apart from those
listed here.
No representative or retailer is authorised to take on any other responsibility relative to
ARAG products.
The period of the guarantees recognised by law, including the commercial guarantees and
allowances for special purposes are limited, in length of time, to the validities given here. In
no case will ARAG recognise loss of prots, either direct, indirect, special or subsequent to
any damage.
6. The parts replaced under guarantee remain the property of ARAG.
7. All safety information present in the sales documents regarding limits in use, performance
and product characteristics must be transferred to the end user as a responsibility of the
purchaser.
8. Any controversy must be presented to the Reggio Emilia Law Court.
8 DISPOSAL AT THE END OF SERVICE
Dispose of the system in compliance with the established legislation in the country of use.

ARAG s.r.l.
Via Palladio, 5/A
42048 Rubiera (RE) - Italy
P.IVA 01801480359
Dichiara
che il prodotto
descrizione: Flussometro elettromagnetico
modello: Orion
codice: 4621AAXXXXX, 4621BAXXXXX, 4621CXXXX, 4622AAXXXXX,
4622ABXXXXX e 4622BAXXXXX
risponde ai requisiti di conformità contemplati nelle seguente Direttiva Europea:
2004/108/CE e successive modificazioni
(Compatibilità elettromagnetica)
Riferimenti alle Norme Applicate:
EN ISO 14982
(Compatibilità elettromagnetica - Macchine agricole e forestali)
CEI EN 61326-1:2007
(Apparecchi elettrici di misura, controllo e laboratorio - Prescrizioni di compati-
bilità elettromagnetica - Parte 1: Prescrizioni generali)
Rubiera, 10 Febbraio 2014
Giovanni Montorsi
(Presidente)
Conformity Declaration

D20051_GB-m08 12/2015
42048 RUBIERA (Reggio Emilia) - ITALY
Via Palladio, 5/A
Tel. +39 0522 622011
Fax +39 0522 628944
www.aragnet.com
info@aragnet.com
Only use original ARAG accessories and spare parts, to maintain safety conditions foreseen by the constructor.
Always refer to the ARAG spare parts catalogue.
This manual suits for next models
25
Table of contents
Other ARAG Measuring Instrument manuals

ARAG
ARAG alfa 310S User manual

ARAG
ARAG Orion Quick start guide

ARAG
ARAG orionX Quick start guide

ARAG
ARAG Visio User manual

ARAG
ARAG 853 Series Service manual

ARAG
ARAG Orion 2 VisualFlow 46212A Series Quick start guide

ARAG
ARAG Orion 2 46211A Series Quick start guide

ARAG
ARAG DigiWOLF 4627 Series Quick start guide

ARAG
ARAG DigiWOLF 4628405 User manual