Arbiter Systems 1084A User manual

Arbiter Systems, Inc. · 1 324 Vendels Circle, Suite 1 21 · Paso Robles, CA 93446 · USA
Tel: +1 .805.237.3831 · Fax: +1.805.238.571 7 · E-mail: sales@arbiter.com · Internet: http://www.arbiter.com 1
TIMING AND FREQUENCY PRODUCTS
Model 1 084A/B/C
GPS Satellite-Controlled Clock
The Arbiter Systems®, Inc. Model 1 084A/B/C GPS
Satellite-Controlled Clock provides the most-needed
GPS system clock features in an economical package.
Three versions allow you to match your requirements.
The Model 1 084A has four LEDs to monitor operating
status. The Model 1 084B adds an LCD setup/status
display and keyboard. The Model 1 084C adds a large
(20 mm or 0.8 in) LED time display.
In all versions, one BNC output provides modulated
IRIG-B while another BNC output is jumper configurable
for IRIG-B unmodulated or Programmable Pulse. Both
outputs have substantial drive capability and can easily
drive multiple loads wired in parallel. A third output is
jumper configurable for either one pulse-per-second,
IRIG-B unmodulated, or IRIG-B modified Manchester
(IEEE Standard 1 344 high-precision time code). This
third output may also be wired (by a simple modification)
to any of the other digital signals generated inside the
Model 1 084A/B/C. These signals include rates of 1 PPH,
1 PPM, 1 0 PPS, 1 00 PPS, 1 kPPS, 1 0 kPPS, 1 00 kPPS,
1 MPPS, 5 MPPS, and 1 0 MPPS; IRIG-E, IRIG-H, and
IRIG-D; Programmable Pulse, or Locked to satellite.
Programmable Pulse generates an output pulse every
1 second to 60000 seconds, daily at a specified time,
or at a specified time of year; pulse duration is 0.01
seconds to 600 seconds. An optional fiber-optic output
generates 1 PPS or IRIG-B in either unmodulated or
modified Manchester format. Also, an event timer input
measures time of occurrence of an applied pulse to
1 00 ns resolution. Up to 500 events may be stored.
The Model 1 084A/B/C includes two Form C (SPDT)
fail-safe relays, compatible with 1 29 Vdc digital fault
recorder inputs. The first provides a LOCKED indication,
and the second can be selected to the FAULT, 1 PPH,
or Programmable Pulse functions.
Twelve receiver channels are standard for best
performance, especially in difficult locations. The internal
backup oscillator is a digitally-compensated crystal
oscillator (DCXO) accurate to 1 x 1 0
-7
over temperature.
Power options include 85 Vac to 264 Vac or 1 1 0 Vdc
to 370 Vdc with an IEC-320 detachable cordset, 85 Vac
to 250 Vac or 1 1 0 Vdc to 350 Vdc terminal strip inlet with
surge withstand, or 1 0 Vdc to 60 Vdc terminal strip inlet
with surge withstand. The terminal-strip versions have
a surge-withstand network designed to meet ANSI/IEEE
C37.90-1 and IEC801 -4 specifications. All power
configurations may be retrofitted in the field.
PD0047200C

Arbiter Systems, Inc. · 1 324 Vendels Circle, Suite 1 21 · Paso Robles, CA 93446 · USA
Tel: +1 .805.237.3831 · Fax: +1.805.238.571 7 · E-mail: sales@arbiter.com · Internet: http://www.arbiter.com
2
TIMING AND FREQUENCY PRODUCTS
Model 1 084A/B/C Specifications
Receiver Ch
a
racteristics
Ti ing Accuracy
Specifications apply at the 1 PPS output, in the presence
of Selective Availability (SA), as of date of publication.
UTC/USNO ± 1 00 ns rms, 1 PPS output
Typical < 40 ns rms, in Position-Hold Mode
Internal Oscillator
Standard DCXO, 1 x 1 0-7, unlocked
Allan variance (locked and in Position-Hold Mode)
1 second 5 x 1 0-1 0 (2 x 1 0-1 0, typical)
1 day 5 x 1 0-1 3
Synchronization
CMOS output signals are synchronized to the 1 PPS
output, ± 50 ns maximum.
IRIG-B modulated, ± 1 µs maximum
The leading edge of the start bit of a received RS-232
data message may be selected to trigger the Event A
input, providing synchronization with 1 00 ns resolution.
Position Accuracy
1 0 meters, rms, 90 % confidence
Satellite Tracking
Twelve (1 2) channel, GPS-L1 , C/A code (1 575.42 MHz).
Receiver simultaneously tracks up to twelve satellites.
Results from all tracked satellites are averaged in Position-
Hold Mode or, with Position-Hold Mode off, using least-
squares estimation.
Acquisition
1 50 seconds typical, cold start
1 5 minutes, 90 % confidence, cold start
40 seconds, typical, with almanac < 1 month old
1 5 seconds, typical, with ephemeris < 4 hours old
The GPS Data Backup Battery is included in all Model
1 084s. This feature improves acquisition time by supplying
constant power to the real-time clock and RAM in the
GPS receiver module.
I/O Configuration
Connectors
Three standard; one IRIG-B modulated connector and
two user-configurable connectors:
1 . IRIG-B modulated, bus driver, 4 Vpp, 20 ohms source
impedance, drives a 50-ohm load at 3 Vpp
2. IRIG-B unmodulated or Programmable Pulse; jumper-
selectable
3. 1 PPS, IRIG-B unmodulated or IRIG-B modified
Manchester; jumper-selectable
umper-selectable outputs are 5 V CMOS bus drivers
with 1 0 ohms source impedance and ± 75 mA drive capability.
Relay Contacts
Two (2) sets, Form C (SPDT) fail-safe, 0.3 A at 1 30 Vdc;
one is Locked function; the second one is jumper-
selectable and may be Fault, 1 PPH, or Programmable Pulse
Progra able Pulse Output
Four modes:
• Every 1 s to 60,000 s, starts top of the minute
• Hourly at a specified offset
• Daily at a specified time of day
• One shot at a specified time of year
Pulse duration is programmable from 0.01 seconds to
600 seconds, except in one-shot mode, where the output
is Low prior to the specified time and High thereafter.
Event A Input
One input is available as an alternate function, with a
simple hardware modification to the 1 PPS configurable
output. The input may be configured to accept an external
1 PPS signal and measure the deviation from 1 PPS/GPS
with 1 00 ns resolution. Each input may also be configured
to record up to 500 sequential events with 1 00 ns
resolution, provided that the events are separated by
1 1 ms. Event data is stored in battery-backed RAM.

Arbiter Systems, Inc. · 1 324 Vendels Circle, Suite 1 21 · Paso Robles, CA 93446 · USA
Tel: +1 .805.237.3831 · Fax: +1.805.238.571 7 · E-mail: sales@arbiter.com · Internet: http://www.arbiter.com 3
TIMING AND FREQUENCY PRODUCTS
Interface
Operator
Display 2 x 20 character supertwist LCD
(Models 1 084B/C only)
20 mm (0.8 in) LED; 9 digits
(Model 1 084C only)
Functions Time: UTC or local
Position: latitude, longitude, altitude
Receiver and clock status
1 PPS (input) deviation
Event time
Status LEDs Operate (green)
On Line (green)
Unlocked (red)
Fault (red)
Keyboard Eight keys (Models 1 084B/C only)
Setup Local time offset
Output code select: Local/UTC
Recorder output A
Daylight Saving Time:
On/Off/Automatic
Backlight control: On/Off/Automatic
Event input: Event/1 PPS
Programmable Pulse setup
Antenna delay
Clock offset
Out-of-Lock time: 1 min. to 99 minutes,
Off, or Zero Delay
Auto-Survey: On/Off, Survey duration
Position Hold: On/Off, Position
Auto/Manual
Option Configuration and Setup
Serial port: RS-232
Syste
RS-232 1 200 baud to 1 9,200 baud; 7 or 8 data
bits; 1 or 2 stop bits; even/odd/no parity
Broadcast modes include ASCII,
Extended ASCII, ASCII with Time
Quality, and Vorne (output once
every second), Status (output on
change of Status) and Event (output
on an Event)
Male 9-pin D-sub; Second port
available (order number 1 084opt1 9)
RS-422/485 Transmit only
Power Require ents
Standard (Option 07)
Voltage 85 Vac to 264 Vac, 47 Hz to 440 Hz,
20 VA max. or 1 10 to 370 Vdc, 1 5 W max.
Inlet IEC-320 with fuse and mating
cordset. Specify cordset P01 - P1 0
General
Physical
Size 1 RU rack mount or tabletop; 260 mm
deep FMS. Rack mounts included
508 mm x 381 mm x 203 mm
(20 in x 1 5 in x 8 in), shipping
Weight 2 kg (4.5 lbs), net
5.5 kg (1 2 lbs), shipping
Antenna 0.75 in pipe (1 in - 1 4 marine) thread
Cable Connection: F-type
80 mm hex (across flats) x 84 mm
(3.2 in x 3.3 in)
1 70 grams (6.0 oz)
Antenna Cable RG-6 type, 1 5 m (50 ft) provided
Weight: 0.69 kg (1 .52 lbs) per 1 5 m
Environ ental
Temperature Operating: 0 °C to + 50 °C
(- 20 °C to + 70 °C typical)
Nonoperating: - 40 °C to + 75 °C
Humidity Noncondensing
EMC Radiated susceptibility: passes
walkie-talkie test
Conducted emissions: power supply
complies with FCC 20780, Class A
and VDE 0871 /6.78 Class A
Surge withstand capability (SWC),
power inlet: designed to meet
ANSI/IEEE C37.90-1 and IEC 801 -4
Certifications and Approvals
CE mark/label and certificate
Model 1 084A/B/C Specifications

Arbiter Systems, Inc. · 1 324 Vendels Circle, Suite 1 21 · Paso Robles, CA 93446 · USA
Tel: +1 .805.237.3831 · Fax: +1.805.238.571 7 · E-mail: sales@arbiter.com · Internet: http://www.arbiter.com
4
TIMING AND FREQUENCY PRODUCTS
Options
Except as noted otherwise, only one I/O Option may be
installed.
I/O
Description Order No.
Four Additional Configurable Outputs 1 084opt03
Parallel BCD Output 1 ms Resolution 1 084opt06
BCD Output with Second RS-232 Port 1 084opt1 7
Second RS-232 Port 1 084opt1 91
Fiber-Optic Output, Type ST 820 nm 1 084opt202
Four Configurable Fiber-Optic Outputs 1 084opt20A
COMTRADE Sample Rate Generator 1 084opt23
8-Channel High-Drive IRIG-B Output 1 084opt27
Power System Time, Frequency and
Phase Monitor 1 084opt28
Four Additional Outputs with Dry
Contact and + 25/50 Vdc 1 084opt29
Network Time Protocol (NTP) /
Precision Time Protocol (PTP) Server 1 084opt34
Power (select only one)
Description Order No.
IEC-320 Power Inlet,
85 Vac to 264 Vac, 1 1 0 Vdc to 370 Vdc 1 084opt07
Terminal Power Strip, Surge Withstand
1 0 Vdc to 60 Vdc 1 084opt08
Terminal Power Strip, Surge Withstand
85 Vac to 250 Vac, 1 1 0 Vdc to 350 Vdc 1 084opt1 0
General
Description Order No.
LCD Backlight 1 084Bopt01
1 084Copt01
On/Off Switch 1 084Aopt04
1 084Bopt04
Accessories
Included
Description Order No.
GPS Antenna, pipe mountable AS0087800
1 5 m (50 ft) RG-6 Antenna Cable CA0021 31 5
1 9 in Rack Mount Kit AS0028200
Quick Setup Guide PD0052500
Power Cord (with Option 07) P09
Available
Description Order No.
Power Cord P01 -P1 0
Operation Manual AS0031 000
1 5 m (50 ft) RG-6 Antenna Cable CA0021 31 5
30 m (1 00 ft) RG-6 Antenna Cable CA0021 330
45 m (1 50 ft) RG-6 Antenna Cable CA0021 345
60 m (200 ft) RG-6 Antenna Cable CA0021 360
75 m (250 ft) RG-6 Antenna Cable CA0021 375
GPS Antenna Mounting Bracket AS0044600
21 dB In-Line Preamplifier AS00447003
Antenna Grounding Block Kit AS0048900
GPS Surge Protector AS0094500
GPS Antenna Cable Splitter AP001 3400
BNC (Male) Breakout to 1 00 mm Wires AP0003400
BNC (Female) Breakout to 100 mm Wires AP0008900
300 m (1 000 ft) Roll RG-6 Cable WC0005000
RG-6 Stripping Tool TF001 3200
RG-6 Type F Crimp Tool TF0006400
RG-6 Type F Male Crimp-on Connector CN0027700
300 m (1 000 ft) Roll RG-1 1 Cable WC0004900
RG-1 1 Stripping Tool TF001 3300
RG-1 1 Type F Crimp Tool TF0006000
RG-1 1 Type F Male Crimp-on ConnectorCN0027800
1 9 in Rack Slide Kit AS00331 00
24 in Rack Mount Kit AS0056600
1
May be combined only with other I/O options that do not include an
additional RS-232 Port
2May be combined with other I/O options
3Used for cable length greater than 75 m (250 ft)
Model 1 084A/B/C Specifications

Arbiter Systems, Inc. · 1 324 Vendels Circle, Suite 1 21 · Paso Robles, CA 93446 · USA
Tel: +1 .805.237.3831 · Fax: +1.805.238.571 7 · E-mail: sales@arbiter.com · Internet: http://www.arbiter.com 5
TIMING AND FREQUENCY PRODUCTS
Cordset and Plug Styles
The following are the available IEC-320 mating cordset
plug style and specifications:
No. Country Specification Rating
P01 Continental Europe CEE 7/7 220V
P02 Australia/NZ/PRC AS 31 1 2-1 981 240V
P03 U.K. BS 1 363 240V
P04 Denmark Afsnit 1 07-2-01 240V
P05 India BS 546 220V
P06 Israel SI 32 220V
P07 Italy CEI 23-16/VII 1971 220V
P08 Switzerland SEV 1 01 1 .1 959 220V
P09 North America NEMA 5-1 5P
and ROC CSA C22.2 #42 1 20V
P1 0 apan IS8303 1 20V
Model 1 084A/B/C Specifications
Other manuals for 1084A
1
This manual suits for next models
2
Table of contents
Other Arbiter Systems Clock manuals

Arbiter Systems
Arbiter Systems 1205D User manual

Arbiter Systems
Arbiter Systems 1084A Installation manual

Arbiter Systems
Arbiter Systems 1201B Installation manual

Arbiter Systems
Arbiter Systems 1205B User manual

Arbiter Systems
Arbiter Systems 1200B User manual

Arbiter Systems
Arbiter Systems 1092A User manual

Arbiter Systems
Arbiter Systems 1205B User manual

Arbiter Systems
Arbiter Systems 1205B User manual

Arbiter Systems
Arbiter Systems 1095A User manual

Arbiter Systems
Arbiter Systems 1088A User manual