Argo LILIUM EVO 11 User manual

14
V 10/19
DEHUMIDIFIER
LILIUM EVO 11 – LILIUM EVO 13
OPERATING INSTRUCTIONS
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage.
Keep these instructions in a safe place for future reference.
EN

15
V 10/19
The Refrigerant R290
•To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The refrigerant is the fluoride R290 = 3 GWP (Global warming
potential). This refrigerant is flammable and inodorous. It can lead to explosions
under certain conditions, however the flammability of this refrigerant is very low and
it can be ignited only by fire.
•Compared to other common refrigerants, R290 is a non-polluting refrigerant with no
harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has
very good thermodynamic features which lead to a really high energy efficiency.
The units therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways
other than those recommended by the manufacturer. Should repair be necessary, contact
your nearest authorized Argoclima Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance has to be stored in a room that doesn’t have
any continuously operating ignition sources. (for example: open flames, an operating gas
appliance or an operating electric heater.) Do not pierce or burn.
Appliance has to be installed, operated and stored in a room with a floor area larger than 4
m2.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance filled with flammable gas R290.
Before using the appliance, read the owner’s manual.
Before installing the appliance, read the installation manual.
Before repairing the appliance, read the service manual.

16
V 10/19
GENERAL OPERATING AND SAFETY INSTRUCTIONS
•This appliance is a highly efficient dehumidifier, designed for
domestic use only!
•Use this dehumidifier only as outlined in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock or malfunctions.
•The unit contains refrigerant; keep it vertical at all times.
•Once you have opened the unit, keep it vertical to allow the
refrigerant to stabilise and wait two hours before operating it.
•Ensure that the required voltage and frequency (220-240V/50Hz)
match the available power source.
•This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved.
•Children shall not play with the appliance.
•Cleaning and user maintenance shall not be made by children
without supervision.
•This product is not a toy. Children of less than 3 years should be
kept away unless continuously supervised.
•Make sure the plug is inserted fully. Do not use multiple adapters.
Do not touch the plug with wet hands. Make sure the plug is clean.
•This product is not a toy. Children should be adequately
supervised to ensure that they do not play with the appliance.
•Disconnect the mains power when the appliance is not in use
or during cleaning operations. Keeping the appliance plugged
in may cause electric shocks or accidents.
•To disconnect the appliance, set the switch to OFF and remove
the plug from the socket. Only pull on the plug. Do not pull the
cord.

17
V 10/19
•Do not bend, drag or twist the cord, or apply force to remove it. Do
not operate the unit if its cable or plug are damaged; doing so
can cause fires or electric shock. If the power cord is damaged,
it must be replaced by a service centre.
•Do not place heavy objects on top of the appliance.
•To prevent water spills, empty the water tank before moving the
appliance.
•Do not tilt the dehumidifier onto one side or turn it upside down, as
the water which runs out could damage the appliance.
•Do not operate the unit on unstable or sloping surfaces:
water leaks can cause it to malfunction or cause excessive
vibration and running noise.
•The dehumidifier must be positioned at least 50 cm away from the
wall or other obstacles, so that the heat can dissipate correctly.
•Close all open windows to maximise dehumidification
efficiency.
•Do not insert objects or sharp instruments into the air outlet
grille.
•Do not cover the air intake and outlet grilles in any way.
WARNING!
In the event of an anomaly, switch the appliance off and unplug
it immediately. Do not dismantle, repair or modify this product
freely. In the event of a malfunction, contact the after-sales
service centre directly.
•Do not immerse the power cord, plug or any other part of the
appliance in water or other liquids.
•Do not expose the dehumidifier to direct sunlight.
•Keep the appliance well away from sources of heat which could
cause plastic parts to become warped.
•Do not spray insecticides, oils or paints near the appliance; doing
so may damage its plastic parts or start a fire.
•Keep flammable gases and oils away from the appliance!

18
V 10/19
•Do not move the appliance while it is operating; doing so can
cause leaks and malfunction.
DESCRIPTION OF PARTS
The following space must be maintained to ensure the operating efficiency of the dehumidifier.
FRONT VIEW
REAR VIEW
Air outlet

19
V 10/19
OPERATING INSTRUCTIONS
APPLIANCE START-UP
Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive
materials and 50 cm away from walls or other obstructions.
Make sure the water tank is in the correct position.
Connect the power cord to a suitable electric socket (220-240V/50Hz).
Turn the appliance on with ON/OFF on the control panel.
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens the dehumidifier goes into defrost mode and the defrost LED comes on. The compressor stops, but the
fan continues running.
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification
function may intermit: please don’t turn off the switch or pull out the power plug of the dehumidifier.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
OPERATING PRECAUTIONS
The appliance will only start operating if the humidity level in the room is above the set value.
The dehumidifier will continue to operate until the set humidity level has been reached, with the exception of
interruptions caused by a full tank. In this case, empty and reinstall the tank: the dehumidifier will now start running
again.
WARNING:
After each interruption of its operation, at least 3 minutes must pass before the dehumidifier starts up again:
this delay prevents the compressor being damaged.
If, on the other hand, the set humidity percentage is higher than the level currently found in the room, the
dehumidifier will not start.
If you follow the start up instructions but the dehumidifier does not start stops for no reason, make sure the plug and
power cord are in good working order. After doing so, wait for 10 minutes and then restart the appliance.
If the dehumidifier still does not start after 10 minutes, or if either the power cord or plug are damaged, switch off the
appliance and contact an after-sales service centre.
WARNING:
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the
room. The room temperature will therefore tend to increase. This is completely normal.
TURNING THE DEHUMIDIFIER OFF
To turn the dehumidifier off press the ON/OFF button. This shuts off power to the unit.
Unplug the appliance if you do not intend to use it for some time.
HOW TO ELIMINATE CONDENSATE
The water extracted from the air can be collected in the provided front tank.
When the tank is full, the unit turns off. The FULL TANK led turns on and the unit beeps for about 20 seconds. Empty
the tank. Use two hands to empty the tank.
To switch off the appliance, press the ON/OFF button and wait a few seconds.
1. Carefully remove the tank using both hands and following the direction of the arrow.
2. Empty the tank.
3. Reposition the tank following the direction of the arrow.
N.B.
Do not use the drain hose when you are collecting condensation in the tank, otherwise water can leak out of the hose.
(1)
(2)
(3)

20
V 10/19
CONTINUOUS CONDENSATE DRAINAGE
You can fit a 17 mm internal diameter PVC hose, a 19 mm outer diameter and a 30cm lengh hose to drain the tank
continuous (included).
Turn off the appliance and remove the plug before connecting the hose.
Remove the drain hole cap and connect a PVC hose (supplied) to the drain hole.
Connect the hose to water drain.
The height of the drainage hose must not exceed that of the hole: do not block the drainage hose exit.
Occasionally check that the adapter and drainage hose are tightly connected and not damaged or blocked.

21
V 10/19
CONTROL PANEL
BUTTONS
(1) ON/OFF BUTTON
Press this button to turn the dehumidifier on and off.
(2) MODE BUTTON
Press this button to enter the mode selection state: the corresponding led will light on. Press “+” or “-“ button to set
the mode; the current mode led will flash. You can select 4 different modes: Deumidify, Automatic, Continuous and
Fast dry clothes. Press the mode button again to confirm the mode selection.
(3) “+” & “-“ BUTTON
Press this button to set the humidity, timing and dehumidification mode.
The humidity can be set only in dehumidify mode from 30% to 80% by pressing these buttons.
The timer can be set from 1 to 24 hours by pressing these buttons.
The dehumidification mode can be set by pressing MODE button and then “+” and “-“ buttons; the corresponding led
indicator lights on.
(4) FAN BUTTON
Press this button to set the fan speed: high and low speed; the corresponding led lights on.
NOTE: This button is valid only when DEUMIDIFY and FAN mode are set.
(5) TIMER ON/OFF BUTTON
Press this button to set the timer from 1 to 24 hours.
If the timer is set to 0 and you press TIMER button or there is no operation in 5 seconds, the dehumidifier will
automatically enter the time off work state.
If the timer isn’t set to 0 and you press TIMER button, the dehumidifier will automatically enter the time off work
state and led lights off; if you don’t press the TIMER button and there is no operation in 5 seconds, the time will set
automatically and LED TIMER lights on. After 5 seconds, the humidity level will return on display.
LED DEFROST
LED TIMER
HIGH-LOW FAN
SPEED LED
(1) ON/OFF
BUTTON
(3)
(5) TIMER
BUTTON
(4) FAN
BUTTON
OPERATION LED
LED TANK FULL
LED CHILD LOCK
“+” AND “-“
BUTTON
(2) MODE BUTTON
DISPLAY
(3)

22
V 10/19
LED
DISPLAY
Shows the relative humidity setting.
TIMER LED
Shows the timer setting.
TANK FULL LED
When the tank is full, the TANK FULL LED lights on and the dehumidifier stops running. A 10 second beep sounds.
Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"), then restore it; the
dehumidifier will start running again.
When the tank is not correctly positioned, the unit will sound a beep lasting approximately 10": then the LED will turn on.
Reposition the tank correctly..
DEFROST LED
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens the dehumidifier goes into defrost mode and the defrost LED lights on. The compressor stops, but the
fan continues running.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
CHILD LOCK LED
To disable the buttons, press the “+” and “-“ buttons for 3 seconds: the LC symbol will appear on the display and the unit
will sound a beep. To reactivate the control panel, press the “+” and “-“ buttons again for 3 seconds.
FAN SPEED LED
Shows the fan speed: HIGH or LOW.
OPERATION LED
You can select one of the following dehumidification modes: the corresponding LED will turn on.
•DEHUMIDIFY mode: the compressor is workable and the fan speed is adjustable. The initial humidity is 55%, low
speed. Humidity range is 30%-80% adjustable.
•AUTOMATIC mode: the compressor is workable and the fan speed is un-adjustable. The initial humidity is 55% and
can’t be set. Fan speed is automatic. If the humidity is higher than 70%, the compressor is working and the fan
speed is high. If the humidity is between 55% and 70%, the compressor is working and the fan speed is low. If the
humidity is less than 55%, the compressor stops working and the fan speed is low.
•CONTINUOUS mode: the compressor runs continuously and the fan speed is low.
•FAST DRY CLOTHES mode: the compressor runs continuously and the fan speed is high.
•FAN modes: the compressor isn’t working and the fan speed is adjustable.
MODE
COMPRESSOR
FAN SPEED
DEFROST
TIMER
TANK FULL
ALARM
HUMIDITY
SETTING
Fan
NO
Adjustable
NO
YES
YES
NO
Dehumidify
YES
Adjustable
YES
YES
YES
YES
Automatic
YES
Adjustable
YES
YES
YES
NO
Continuous
YES
Low
YES
YES
YES
NO
Fast Dry
clothes
YES High YES YES YES NO
LED COLOR:
The front LED under the control panel changes colour in according to the humidity level in the room:
- When the room humidity is lower than 50% (<=), the led light is BLUE.
- When the room humidity is between 50% to 70%, the led light is GREEN.
- When the room humidity is higher than 70% (>=), the led light is RED.
AUTO RESTART: the dehumidifier starts up again after a power failure.

23
V 10/19
CLEANING AND MAINTENANCE
MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE
Warning
Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric
shock and malfunction.
Warning
Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.
Use a damp and soft cloth to clean the exterior surface of the dehumidifier.
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage
the surface or colour of the casing.
CLEANING THE WATER TANK
We advise removing the tank once every few weeks to prevent mould and bacteria forming on it. Fill the tank with clean
water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly.
CLEANING THE AIR FILTER
The filter is designed to remove dust or dirt from the air.
If the filter is clogged by dust, electricity consumption will be higher than
normal.
Cleaning instructions:
1. Remove the tank.
2. Remove the filter by pulling the flap and pulling down the
filter until complete extraction. Clean the filter with a vacuum
cleaner or wash it with clean water at no more than 40°C.
DO NOT USE ALCOHOL, BENZENE OR OTHER
AGGRESSIVE PRODUCTS TO CLEAN THE FILTER. Leave
the filter to dry naturally, then reposition it in the relevant
slot.
3. Reinsert the filter pushing it upwards until you hear a sound.
4. Reposition the tank.
Do not use the dehumidifier without the filter as dust may affect the
efficiency of the evaporator, resulting in higher energy consumption.

24
V 10/19
TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
The dehumidifier is not working.
It is not possible to adjust the settings.
The temperature is above 32 ° C or below 5
°C.
The internal tank is full.
The tank is not positioned correctly.
The set humidity level is higher than that in the
room.
Empty the tank
Position the tank correctly
The noise suddenly increases while
running
The compressor has just started.
There is a power connection problem.
The unit is placed on an uneven surface.
Condensation is not collected in the
tank
The room is too big for the unit's capacity.
The doors are open.
There are other devices producing moisture in
the room.
Reduced dehumidification effect The room temperature is too low.
The set humidity level is inadequate.
The filter is full of dust.
The doors and windows are open.
If the unit is running with a temperature
between 5 and 15 °C, the unit will pause for
automatic defrosting. The compressor will
pause for short periods. After the defrost, the
unit will resume normal operation.
Reduce the humidity level.
Clean the filter.
Close any doors and windows.
At first, the air might have a musty
smell
Due to the temperature difference of the heat
exchanger, the air might have a strange smell
at first.
There is water in the tank even when
using the hose for continuous
condensation drainage
Check the drainage connections.
The drainage hose is not connected properly.
Connect the hose correctly.
Remove the drainage hose and
replace it.
The ON/OFF LED does not turn on
when the power is connected
There is no power or the plug is not inserted
correctly.
Check the electrical power supply.
Make sure that the electric circuit
and plug are not damaged.
Make sure that the cable is not
damaged.
The dehumidifier stops working during
dehumidifying process.
Whether the room temperature is too high or
too low and out of the working scope of the
dehumidifier.
The dehumidifier may start
automatically when the room
temperature returns to the working
scope.
The clothing can’t be dry fast. Whether the room temperature is very low. The wet clothing may dry more
slowly in low temperature.
The dehumidifier stops intermittently
during the operation.
The defrosting.
The humidity of the room can’t reduce. The room area is too big, which is over its
application scope.
The door and windows of the room aren’t
closed.
The machine unit is operated with a kerosene
heater which releases steam.
Unpleasant smell. The smell may come from the wall, furniture
and other things.
The machine unit makes a sound
during operation.
The sound made by the flowing of the
refrigerant may eliminate or lower
automatically while the system operates
stably.
There is water in the tank.
Since each machine unit has taken operation

25
V 10/19
test before leaving the factory, some water
remains on the evaporator flows to the water
tank.
The FULL indicator led is on. When the water tank is full, the FULL indicator
led is on for reminding.
REGULATION (EU) N. 517/2014 - F-GAS
LILIUM EVO 11
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0.035 = 0.000105
Tons CO2equiv.
Do not release R290 into the atmosphere.
LILIUM EVO 13
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0.045 = 0.000135
Tons CO2equiv.
Do not release R290 into the atmosphere.
INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN
DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the
crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is
levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human
health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and
recycled, with significant savings in terms of energy and resources.
The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
www.argoclima.com
Other manuals for LILIUM EVO 11
1
Table of contents
Other Argo Dehumidifier manuals

Argo
Argo ALICE 13 User manual

Argo
Argo PLATINUM EVO 21 User manual

Argo
Argo DRY NATURE 11 User manual

Argo
Argo DRY PURY 25 User manual

Argo
Argo DRY COMPACT 21 User manual

Argo
Argo DRY BABY 11 User manual

Argo
Argo PLATINUM EVO 21 User manual

Argo
Argo LILIUM ART 11 User manual

Argo
Argo DRY BABY 11 User manual

Argo
Argo ALICE BABE User manual

Argo
Argo DEOLO BABY 11 User manual

Argo
Argo LILIUM EVO 11 User manual

Argo
Argo DRY PURY 11 User manual

Argo
Argo DRY DIGIT EVO 13 User manual

Argo
Argo NARCISO 12 User manual

Argo
Argo DRY PURY 25 User manual

Argo
Argo DRY PURY EVO 11 User manual

Argo
Argo NARCISO baby 10 User manual

Argo
Argo Dry 41 User manual

Argo
Argo LILIUM 11 User manual