Arico tc5f User manual

長新科技股份有限公司
ARICO Technology Co., Ltd.
Registeredto
ISO9001
TC5F 熱澆道溫度控制器
TC5F Hot-Runner Temperature Controller
操作手冊
USER'S MANUAL
VNA0000015
Ver.:TC5F-1.0.4
長新科技股份有限公司 ARICO Technology Co., Ltd.
保有權利於任何時間未經通知而修改或變更本手冊內容及型式,未經本公司同意,不得作任何形式的使用。
reserves the right to make any kind of design or functional modification at any moment without prior notice.

To avoid wrong operation, which may result in human injured or machine
damage, please read this instruction carefully before use the instrument.
CONTENT
Chapter 1 TC5F TEMPERATURE CONTROL MODULE
1-1 Features 1
1-2 Specification 1
1-3 Faceplate 2
1-4 Operation description 4
Chapter 2 CABINET&ACCESSORIES
2-1 Dimension 10
2-2 Specification 11
2-3 Connection description 11
2-4 Type of power wiring 12
2-5 Connector wiring 14
Chapter 3 ORDER CODERING
3-1 Cabinet 17
3-2 Cable 17
3-3 Housing 18
3-4 Hood 18
3-5 Blank Plate 18
3-6 Connector 18
3-7 Trouble shooting 19

ARICO Technology Co., Ltd. -1-
Chapter 1 TC5F TEMPERATURE
CONTROL MODULE
1-1 Feature
■Dual SV temperature control.
■Tri lines LED display.
■Auto /Manual function.
■PID auto temperature control.
■Selectable two thermocouple types.(J or K)
■Selectable two temperature scales.(°C or °F)
■Selectable six alarm modes.
■Selectable two trigger output modes.(Zero cross or phase angle)
■Fuse break indicator.
■Electric current, output percentage, frequency for power display function.
■Heater breaks, shorts out, wears out to detect and examine the function.
■Thermocouple break and inverse detect.
■T h e r m o c o u p l e r a n g e K T Y P E : 0 ~ 60 0 °C (3 2 ~9 9 9 °F)/J T Y P E : 0~60 0 °C (3 2 ~99 9 °F).
■RS485 communication: ASCII and RTU molding.
1-2 Specification
■Power input: 230VAC±15%
■Power frequency: 50/60Hz
■Power consumption: 7W
■Input impedance: 10M Ω
■Output wattage: 3600W(Max)、15A/240VAC (
Every module)
■Storage temperature: -20~70℃
■Working temperature: 0~50℃
■Work Humidity: 10~80%RH (Non-condensing)
■Control accuracy: ±0.25%
■Measurement accuracy: ±0.25%

-2-
1-3 Faceplate
1-3-1 Faceplate description
(1) PV:
1.Normal mode: Present value
2.Parameter mode: Parameter name
(2) SV:
1.Normal mode: Setting value
2.Parameter mode: Parameter name
3.M a n u a l o u t p u t o r p a r a m e t e r : M a n u a l o u t p u t %
(3) A u x . d i s p l a y : o u t p u t p e r c e n t a g e , e l e c t r i c c u r r e n t ,
f r e q u e n c y d i s p l a y .
(4) P A G E k e y : P a r a m e t e r l e v e l a n d p a r a m e t e r s e l e c t
k e y .
(5) Set key: Set enable and digital shift key.
(6) Increment key: Setting number increase.
(7) Decrement key: Setting number decrease.
(8) Aux. display PAGE key: Parameter select key
(9)
PID tuning indicator: In PID tuning, progress
indicator flashes.
(10)Manual output: Light up when Manual output
(11)A l a r m i n d i c a t o r : L i g h t u p w h e n a l a r m h a p p e n .
(12)
o u t p u t i n d i c a t o r : L i g h t u p w h e n i n s t r u m e n t o u t p u t
(13) C o o l i n d i c a t o r : W h i l e c o o l i n g t h e i n d i c a t o r l a m p i s o n
(14) Fuse 1 indicator: Light up when fuse 1 break
(15) Fuse 2 indicator: Light up when fuse 2 break
(16) Power switch
(1)
(2)
(3)
(4)
(6)
(7)
(16)
(14)
(13)
(12)
( 1 1 )
(10)
(9)
(8)
(5)
(15)

ARICO Technology Co., L t d . -3-
1-3-2 Faceplate appearance and dimension
Deviation: ±5mm

-4-
1-4 Operating description
1-4-1 Parameter flow chart

ARICO Technology Co., Ltd. -5-

-6-
1-4-2 Soft start (Heater dehumidify) function
To avoid the humidity burning the heater out, the soft start function could
output a lower current to dehumidify the heater when the power turned on.
Soft start condition:
The soft start percentage (SSP) and time (SST). After power turned on,if
SV>PV;PV<120°C, manual and PID tuning function are disabled, the soft
start will be executed. Set SST to zero tostop soft start function.
Soft start action state:
Before SST time countdown completes, soft start outputs in 1%/sec
accumulative mode until it gets SSP setting value. The accumulative mode
will stop and wait SST time to complete countdown.
Soft start stop on halfway:
Press F for 2 sec to close soft start.
1-4-3 Control mode
Auto mode: The instrument performs PID auto temperature control
Manual mode: Manually adjust output percentage (UNIT displays “P”) via NOP
to hold the temperature.
Manual/Auto mode switch: Press display interchange for 2 sec.
1-4-4 Communication
Communication mode: Modbus ASCII / RTU
Baud rate: 9600/19200/(value of production38400)
ID: 1-250(value of production: 1)
According to the procedure of HMI

ARICO Technology Co., Ltd. -7-
1-4-5 Process control:
Start conditions: STG is ON
Action mode:Before TGT time completes countdown. SV1 is the main display.
1-4-6 Over current protect
Control:
Regular: Actual current < 15A
Malfunction: When actual current is >15A, the output will stop and O1ST
display onthefirstsetof monitor. After 1 minute, output resumes
and detects the current. If it’s 15A and it occurs more than 3
times, the output stops and the alarm starts with O1ST display.
(PS: If the heater shorts out, the 20A fuse breaks)
TRIAC Malfunction: When start action delays within 30 sec, the module will
force output ratio to 0%.
Regular: Actual current= 0 A
Malfunction: When actual current is> 0 A, control will stop and alarm start,
O1ST message will appear on first set of LED until the model
starts power again.

-8-
1-4-7 Cooling control
Start term: COOL= ON
Action mode:The cycle time is CYT1. The output is P control way.
1-4-8 Alarm code ERRC
1 : Thermocouple break
2 : Thermocouple inverse
4 : Heat output short
8 : Heat output break
1-4-9 Error message
(1) :Thermocouple break
(2) :Heater break
(3) :PV lower than SV
(4) :Heat output short

ARICO Technology Co., Ltd. -9-
1-4-9 PID auto tuning function
To get the optimal PID value in some system, it is possible to execute "PID
auto tuning" function at first use or heater system change
After finishing auto tuning, the optimal PID will be saved into the instrument
and memory and will use the latest PID value for optimal temperature control.
PID auto tuning function:
(1)PV must belower than 120°C or 180°F。
(2)SV must be higher than PV for 80°C or 100°F
(3)Set parameter TUN into YES
PS: During PID auto tuning execution, the decimal point of PV will flash. After
the instrument gets the optimal PID, the decimal point turns off and the
instrument returns to auto temperature control.

-10-
Chapter 2 CABINET
2-1 Dimension
Unit:mm
Cabinet
A
B
C
D
1 Zone
188
96
248
30
2 Zones
215
223
299
45
4 Zones
323
6 Zones
424
8 Zones
524
12 Zones
726

ARICO Technology Co., Ltd. -1 1 -
2-2 Specification
Type
T5A01
T5A02
T5A04
T5A06
T5A08
T5A12
Zone
Item
1
2
4
6
8
12
Power Switch
(A)
--
32
50
50
63
63
Output
connector
4pin+E
(ground)
16pins
x1
16pins
x1
24pins
x1
16pins
x2
24pins
x2
Power Cable
2.0mm
2
x3C
x3M
5.5mm
2
x5C
x3M
5.5mm
2
x5C
x3M
5.5mm
2
x5C
x3M
8.0mm
2
x5C
x3M
8.0mm
2
x5C
x3M
Weight (kg)
(non-module)
1.75
7.25
9
11.25
12.5
16
2-3 Connection Description
Connector type
a: single hook
b: single button
c: dual hook
d: dual button
connector
A
B
C
D
Name
Housing
Hood
Hood
Housing
T5E
T5F
T5F
T5E
Type
Socket
Plug
Socket
Plug
combination
1*
a
b
b
A
2
c
d
d
C
3
d
c
c
d
*Standard type **T5A01only for type1

-12-
2-4 Type of power wiring

ARICO Technology Co., Ltd. -13-
The following power wiring only for T5A01.
Caution
1. Before operating, check connection (“y” or “△”) and its voltage.
2. All instruments must be used in accordance with the specification to prevent
fire or damage to instrument and equipment.
3. Make sure the ac power input is switched off before maintenance.
Note: power type A and B differ with regard to “ ” connections.
The FGND must be connected with earth ground.
2-4-4 Communication port
Socket
Plug

-14-
2-5 Connector wiring
Single cabinet connector wiring
ZONE
CONN
CONNECTOR ASSIGNMENT
1
4*1
A4-1
Multi-cabinet connector wiring are divided into A, B, C and D type as below:
A type wiring
ZONE
CONN
CONNECTOR ASSIGNMENT
2
16*1
A16-2
4
16*1
A16-4
6
24*1
A24-6
8
16*2
A16-8
12
24*2
A24-12

ARICO Technology Co., Ltd. -15-
B type wiring
ZONE
CONN
CONNECTOR ASSIGNMENT
2
16*1
B16-2
4
16*1
B16-4
6
24*1
B24-6
8
16*2
B16-8
12
24*2
B24-12

-16-
C type wiring
ZONE
CONN
CONNECTOR ASSIGNMENT
8
16*2
C16-8
12
24*2
C24-12
D type wiring
ZONE
CONN
CONNECTOR ASSIGNMENT
2
16*1
D16-2
4
16*1
D16-4
6
24*1
D24-6
8
16*2
D16-8
12
24*2
D24-12

ARICO Technology Co., Ltd. -17-
Chapter 3 ORDER CODE
3-1 CabinetT5A
T5A
a: Zone
01: 1 zone
02: 2 zones
04: 4 zones
06: 6 zones
08: 8 zones
12: 12 zones
b: Housing and Hood
SHB: Housing is single hook, hood is single button*
DHB: Housingis dual hook, hood is dual button
DBH: Housingis dual button, hood is dual hook
c: Power Wiring
A0: A type 3-phase 4-wire 200~242VAC
B0: B type 3-phase 5-wire 380~415VAC
A1: A type 3-phase 4-wire 200~242VAC*
B1: B type 3-phase 5-wire 380~415VAC* *: for 1 zone T5A01
3-2 Cable: T5C
Order code: T5C
a: Wiring
b: PIN
c: Length(M)
◎Standard Length 3M
d: Power Cable Length
03: 3m (standard)
e: O/P Connector Wiring
A: A type
B: B type
C: C type
f: Cable Wiring
00: without connection cable
03: 3m (standard)

-18-
3-3 Housing: T5E
Single Single button
Dual hook Dual button
Order code: T5E
a: PIN--4、16、24
b: Type
1. Single hook
2. Dual hook
3. Single button
4. Dual button
3-4 Hood:T5F
Single hook Single button
Dual hook Dual button
Order code:T5F
a: PIN--4、16、24
b: Type
1. Single hook
2. Dual hook
3. Single button
4. Dual button
3-5 Blank plate
Order code: T5G
3-6 Connector
Order code: T5D
a: PIN--4、16、24
b: Type
1. Plug
2. Socket
This manual suits for next models
1
Table of contents
Other Arico Temperature Controllers manuals