artisan 40-549 User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Visit our website - Click HERE

pickeringtest.com
Issue 2.3 November 2020
40-549 User Manual
PXI 5 Amp Power EMR Matrix Module

Page (II) 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Page (II) REED RELAY MODULE 40-110/115/120/125
pickering
© COPYRIGHT (2020) PICKERING INTERFACES. ALL RIGHTS RESERVED.
No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by
any means without the written permission of Pickering Interfaces.
Technical details contained within this publication are subject to change without notice.
ISO 9001
Reg No. FM38792

Page (III)
5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Page (III)
REED RELAY MODULE 40-110/115/120/125
pickering
TECHNICAL SUPPORT
For Technical Support please contact Pickering Interfaces either by phone, the website or via e-mail.
WARRANTY
All products manufactured by Pickering Interfaces are warranted against defective materials and workmanship for a period of
three years, excluding programmable power supplies, from the date of delivery to the original purchaser. Any product found to be
defective within this period will, at the discretion of Pickering Interfaces be repaired or replaced.
Products serviced and repaired outside of the warranty period are warranted for ninety days.
Extended warranty and service are available. Please contact Pickering Interfaces by phone, the website or via e-mail.
ENVIRONMENTAL POLICY
Pickering Interfaces operates under an environmental management system similar to ISO 14001.
Pickering Interfaces strives to full all relevant environmental laws and regulations and reduce wastes and releases to the
environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and
safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can
be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
Worldwide Technical Support and Product Information
pickeringtest.com
Germany
Tel: +49 89 125 953 160
E-mail: [email protected]
Sweden
Tel: +46 340-69 06 69
E-mail: [email protected]
USA
Tel: (West) +1 541 471 0700
Tel: (East) +1 781 897 1710
E-mail: [email protected]
Czech Republic
Tel: +420 558 987 613
E-mail: [email protected]
France
Tel +33 9 72 58 77 00
E-mail [email protected]
Pickering Interfaces Headquarters
Stephenson Road Clacton-on-Sea CO15 4NL United Kingdom
Tel: +44 (0)1255-687900
E-Mail: [email protected]
China
Tel: +86 4008 799 765
E-mail: [email protected]

Page (IV) 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Page (IV) REED RELAY MODULE 40-110/115/120/125
pickering
MEANING / DESCRIPTION SYMBOL
PROTECTIVE EARTH (GROUND)
To identify any terminal which is intended for connection to an external conductor for
protection against electric shock in case of a fault, or the terminal of a protective earth
(ground) electrode.
DANGEROUS VOLTAGE
To indicate hazards arising from dangerous voltages.
WARNING / CAUTION
An appropriate safety instruction should be followed or caution to a potential hazard
exists.
Refer to the relevant instructions detailed within the product manual.
HEAVY
If this product is heavy reference should be made to the safety instructions for
provisions of lifting and moving.
STATIC SENSITIVE
To indicate that static sensitive devices are present and handling precautions should
be followed.
!
kg
SAFETY SYMBOLS
PRODUCT SAFETY
The following safety symbols may be used on the product and throughout the product documentation.

Page (V)
5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Copyright Statement ...................................................................II
Technical Support and Warranty................................................III
Product Safety .............................................................................IV
Contents (this page)....................................................................V
Warnings and Cautions ..............................................................VII
Section 1
Technical Specication...............................................................1.1
Section 2
Technical Description .................................................................2.1
Functional Description..........................................................2.1
Section 3
Installation....................................................................................3.1
Pre Operation Checks...........................................................3.1
Hardware Installation ............................................................3.2
Software Installation .............................................................3.2
Testing Operation ..................................................................3.3
Section 4
Programming Guide....................................................................4.1
Programming Options for PXI Modules ..............................4.1
Programming The Matrix ......................................................4.2
Using IVI Driver, Direct Driver or VISA Driver .....................4.3
Section 5
Connector Information................................................................5.1
Section 6
Troubleshooting ..........................................................................6.1
Section 7
Maintenance Information............................................................7.1
Relay Look-Up Tables ...........................................................7.1
CONTENTS

Page (VI) 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
THIS PAGE INTENTIONALLY BLANK

Page (VII)
5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Page (VII)
2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579
pickering
WARNINGS AND CAUTIONS
WARNING - HAZARDOUS ENVIRONMENTS SYMBOL
This product is not specically designed for use in hazardous environments, for example in explosive
atmospheres. If the product is to be used in hazardous environments we recommend that the user
ensures suitable protective measures are taken.
!
WARNING - DANGER OF ELECTRIC SHOCK SYMBOL
This module may contain hazardous voltages. Before removing the module from the rack remove all
supplies and disconnect user I/O signals.
Unused slots in the host chassis are populated with blanking plates to prevent access to user I/O
signals that may be present. Blanking panels are available to order from Pickering in a variety of
slot widths. If the product is not used in this manner for example by using an extender card then
additional care must be taken to avoid contact with exposed signals.
Not to be used in safety critical circuits, refer to the Pickering Interfaces’ terms & conditions of sale.
This module must not be used for the switching of Mains Circuits. For the switching of voltages up
to the module’s full specication, Secondary Circuit power supplies and the Device Under Test must
be fully isolated from the Mains Circuit and the safety earth.
The host chassis must be correctly installed and be connected to mains or factory safety ground,
please refer to your chassis installation manual.
Diagram Showing Separation Between The Mains Circuit and Secondary Circuit / DUT
For the purposes of this document, a Mains Circuit is an installation classied as Overvoltage
Category II up to 300V. Separation between the Secondary Circuit and Mains Circuit is achieved
by a transformer in which the primary windings are separated from the secondary windings by
reinforced insulation, double insulation, or a screen connected to the protective conductor terminal.
CAUTION - HANDLING OF ELECTROSTATIC-SENSITIVE DEVICES SYMBOL
Certain semiconductor devices used in this equipment are liable to damage due to static voltage.
Observe the following precautions when handling these devices in their unterminated state, or
sub-assemblies containing these devices:
1. Persons removing sub-assemblies from equipment using these devices must be earthed by a
wrist strap and a resistor at the point provided on the equipment.
2. Soldering irons used during the repair operations must be low voltage types with earthed tips and
isolated from the mains voltage by a double insulated transformer.
3. Outer clothing worn must be unable to generate static charges.
4. Printed Circuit Boards (PCBs) tted with these devices must be stored and transported in
anti-static bags.
PXI Switching
Module
Device
Under Test
Power
Supply
Power
Supply
Host Chassis
Secondary Circuit
Mains
Circuit
Mains
Circuit
Mains/Factory
Safety Ground

Page (VIII) 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
Page (VIII) 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579
pickering
CAUTION - PRODUCT DOCUMENTATION SYMBOL
Suitably qualied & trained users should ensure that the accompanying documentation is fully read
and understood before attempting to install or operate the product.
!
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
All cleaning and servicing requires the equipment to be isolated and disconnected from the power source and user I/O
signals (refer to the Maintenance Section).
• Appropriate manual handling procedures should be followed as dictated by the weight of the individual module or
the combined weight of the modules & chassis.
• Should a fault occur with the module or chassis, immediately isolate and disconnect the incoming power to the
chassis and the user I/O signals.
• Ensure the equipment is installed, operated and maintained by trained and authorised personnel.
• For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on
the front of the unit.

Page 1.1
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 1 - TECHNICAL SPECIFICATION
SECTION 1 - TECHNICAL SPECIFICATION
pickeringtest.com
PXI 5A Power EMR Matrix 40-549
ISSUE 3.1 NOV 2020
• High Density, High Current Switching
• 1-Pole Power Matrix Available in Single 16x4,
Single 8x8, Dual 8x4 and Single 8x4 Formats
• 5A Current Rating With 150W/1250VA
Maximum Power
• Hot Switch to 110VDC/250VAC, Cold Switch to
400VDC/250VAC
• High Quality Electro-mechanical Relays
• VISA, IVI & Kernel Drivers Supplied for
Windows
• Supported by PXI or LXI Chassis
• 3 Year Warranty
The 40-549 is a single pole power matrix module, suitable for
switching inductive/capacitive loads up to 5A with 110VDC/250VAC
hot switching and 400VDC/250VAC cold switching. It is available in
the following congurations:
• 40-549-001 Single 16x4 1-Pole Matrix
• 40-549-002 Single 8x8 1-Pole Matrix
• 40-549-003 Dual 8x4 1-Pole Matrix
• 40-549-004 Single 8x4 1-Pole Matrix
Connections are made via a front panel 25-pin D-type plug which is
supported by our comprehensive range of cables and connectors.
40-549-003 Dual 8x4 Power Matrix
XA2
XA4
XA8
XA1
XA3
XA5
XA6
XA7
YA2
YA4
YA1
YA3
MATRIX
CROSSPOINT
XB2
XB4
XB8
XB1
XB3
XB5
XB6
XB7
YB2
YB4
YB1
YB3
X2
X4
X8
X1
X3
X5
X6
X7
X12
X9
X10
X11
X14
X16
X13
X15
Y2
Y4
Y1
Y3
MATRIX
CROSSPOINT
40-549-001 16x4 Power Matrix
40-549-004 8x4 Power Matrix
X2
X4
X8
X1
X3
X5
X6
X7
Y2
Y4
Y1
Y3
MATRIX
CROSSPOINT
X2
X4
X8
X1
X3
X5
X6
X7
Y2
Y4
Y8
Y1
Y3
Y5
Y6
Y7
MATRIX
CROSSPOINT
40-549-002 8x8 Power Matrix
Power Matrix Modules are intended for switching heavy AC or DC
loads or for slave switching large external relays, contactors or
solenoids.
The module is suitable for applications requiring switching of either
mains voltage or DC current.

Page 1.2 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
SECTION 1 - TECHNICAL SPECIFICATION
5A Power EMR Matrix – 40-549
pickeringtest.com
Specifications
Switching Specification
Contact Type: Gold clad silver alloy
Cold Switching Capacity
Maximum Current:
Maximum Voltage:
Typical Pulse Capability:
5A
400VDC/250VAC*
Cold Switch 10A for 100ms
under low duty cycle conditions
(please contact sales ofce for
further advice)
Hot Switching Capacity
Maximum Current:
Maximum Voltage:
Maximum Power:†
Minimum Switching Capacity:
5A
110VDC/250VAC*
150W/1250VA
10mA, 5VDC ‡
Initial On Path Resistance:
Off Path Resistance:
<150mΩ (60mΩ typical)
>109Ω
Bandwidth (3dB insertion loss
into 50Ω typically better than):
Crosstalk (channel to channel
typically better than):
Isolation (open channel
typically better than):
20MHz
-70dB @ 100kHz
-55dB @ 1MHz
-24dB @ 10MHz
75dB @ 100kHz
60dB @ 1MHz
20dB @ 10MHz
Operate Time: 10ms typical
Expected Life (operations) - resistive load
Mechanical Life:
At Max. Switch Capacity:
>2x107
>5x104 (5A 250VAC, 5A 30VDC)
>1x105 (3A 250VAC, 3A 30VDC)
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.
† For variation of maximum hot switching capacity of voltage with
current refer to plot.
‡ Hot switching at/beyond the levels specied is recommended for
optimal contact resistance stability. These values can change due
to factors such as switching frequency, environmental conditions &
desired reliability level.
Power Requirements
+3.3V +5V +12V -12V
0 1.5A 30mA 0
Mechanical Characteristics
Single slot 3U PXI (CompactPCI card).
3D models for all versions in a variety of popular le formats are
available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via front panel 25-pin male-D-type connector, for pin outs
please refer to the operating manual.
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0°C to +55°C
Up to 90% non-condensing
5000m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20°C to +75°C
Up to 90% non-condensing
15000m
PXI & CompactPCI Compliance
The module is compliant with the PXI Specication 2.2. Local Bus,
Trigger Bus and Star Trigger are not implemented.
Uses a 33MHz 32-bit backplane interface.
Safety & CE Compliance
All modules are fully CE compliant and meet applicable EU
directives: Low-voltage safety EN61010-1:2010, EMC Immunity
EN61326-1:2013, Emissions EN55011:2009+A1:2010.
Relay Type
The 40-549 is tted with electro-mechanical power relays, gold clad
silver alloy.
40-549 Current/Operating Life Plot
40-549 Current/Voltage Plot
AC Resisve
DC Resisve
125VAC Resisve
30VDC Resisve
250VAC Resisve

Page 1.3
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 1 - TECHNICAL SPECIFICATION
5A Power EMR Matrix – 40-549
pickeringtest.com
Ordering Information
Support Products
Spare Relay Kits
Kits of replacement relays are available for the majority of
Pickering’s PXI switching products, simplifying servicing and
reducing down-time.
Product Relay Kit
40-549-001
40-549-002
40-549-003
40-549-004
91-100-020
91-100-020
91-100-020
91-100-020
For further assistance, please contact your local Pickering sales
ofce.
Mating Connectors & Cabling
For connection accessories for the 40-549 modules please
refer to the 90-008D 25-pin D-type Connector Accessories data
sheet where a complete list and documentation can be found for
accessories, or refer to the Connection Solutions catalog.
Product Order Codes
5A Power EMR 1-Pole Matrix, Single 16x4
5A Power EMR 1-Pole Matrix, Single 8x8
5A Power EMR 1-Pole Matrix, Dual 8x4
5A Power EMR 1-Pole Matrix, Single 8x4
40-549-001
40-549-002
40-549-003
40-549-004
Product Customization
Pickering PXI modules are designed and manufactured on our own
exible manufacturing lines, giving complete product control and
enabling simple customization to meet very specic requirements.
Customization can include:
• Alternative relay types
• Mixture of relay types
• Alternative number of relays
• Different performance specications
All customized products are given a unique part number, fully
documented and may be ordered at any time in the future. Please
contact your local sales ofce to discuss.

Page 1.4 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
SECTION 1 - TECHNICAL SPECIFICATION
5A Power EMR Matrix – 40-549
pickeringtest.com
Supporting Products & Software
We also offer customized cabling and have a free online Cable Design Tool that can be
used to create custom cable solutions for many applications.
Visit: pickeringtest.com/cdt to start your design.
Mass Interconnect
We recommend the use of a mass interconnect solution when an Interchangeable Test
Adapter (ITA) is required for a PXI or LXI based test system. Our modules are fully
supported by both Virginia Panel and MacPanel.
Pickering Reed Relays
We are the only switch provider with in-house reed relay manufacturing capability
via our Relay Division. These instrument grade reed relays feature SoftCenter™
technology, ensuring long service life and repeatable contact performance.
To learn more, please go to: pickeringrelay.com
Chassis Compatibility
This PXI module must be used in a suitable chassis. It is compatible with the following chassis types:
• All chassis conforming to the 3U PXI and 3U Compact PCI (cPCI) specication
• Legacy and Hybrid Peripheral slots in a 3U PXI Express (PXIe) chassis
• Pickering Interfaces LXI or LXI/USB Modular Chassis
Chassis Selection Guide
Standard PXI or hybrid PXIe Chassis from any Vendor:
• Mix our 1000+ PXI switching & simulation modules with any
vendor’s PXI instrumentation
• Embedded or remote Windows PC control
• Real-time Operating System Support
• High data bandwidths, especially with PXI Express
• Integrated module timing and synchronization
Pickering LXI or LXI/USB Modular Chassis—only accept
our 1000+ PXI Switching & Simulation Modules:
• Ethernet or USB control enables remote operation
• Low-cost control from practically any controller
• LXI provides manual control via Web browsers
• Driverless software support
• Power sequencing immunity
• Ethernet provides chassis/controller voltage isolation
• Independence from Windows operating system
Connectivity Solutions
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+
products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are
manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules.
Connectors & Backshells Multiway Cable Assemblies RF Cable Assemblies Connector Blocks

Page 1.5
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 1 - TECHNICAL SPECIFICATION
5A Power EMR Matrix – 40-549
pickeringtest.com
Supporting Products & Software
© Copyright (2020) Pickering Interfaces. All Rights Reserved
Pickering Interfaces maintains a commitment to continuous product development, consequently we reserve the right to vary from the description given in this data sheet.
Programming
Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and
popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os
The VISA driver is also compatible with Real-Time Operating Systems such as LabVIEW RT. For other RTOS support contact Pickering.
These drivers may be used with a variety of programming environments and applications including:
• Pickering Interfaces Switch Path Manager
• National Instruments products (LabVIEW, LabWindows/CVI, Switch Executive, MAX, TestStand, VeriStand, etc.)
• Microsoft Visual Studio products (Visual Basic, Visual C+)
• Keysight VEE and OpenTAP
• Mathworks Matlab
• Marvin ATEasy
• MTQ Testsolutions Tecap Test & Measurement Suite
Drivers for popular Linux distributions are available, other environments are also supported, please contact Pickering with specic enquiries.
We provide Soft Front Panels (SFPs) for our products for familiarity and manual control, as well as comprehensive documentation and
example programs to help you develop test routines with ease.
To learn more about software drivers and development environments, please go to:
pickeringtest.com/software
Signal Routing Software
Our signal routing software, Switch Path Manager, automatically selects and energizes switch
paths through Pickering switching systems. Signal routing is performed by simply dening test
system endpoints to be connected together, greatly accelerating Test System software
development. To learn more, please go to: pickeringtest.com/spm
Diagnostic Relay Test Tools
eBIRST Switching System Test Tools are designed specically for our PXI, PCI or LXI
products, these tools simplify switching system fault-nding by quickly testing the system
and graphically identifying the faulty relay.
To learn more, please go to: pickeringtest.com/ebirst
Three Year Warranty & Guaranteed Long-Term Support
All standard products manufactured by Pickering Interfaces are warranted against defective materials and workmanship for a period of three
years from the date of delivery to the original purchaser. Extended warranty and service agreements are available for all our modules and
systems with various levels to suit your requirements. Although we offer a 3-year warranty as standard, we also include guaranteed long-
term support—with a history of supporting our products for typically 15-20 years. To learn more, please go to: pickeringtest.com/support
Available Product Resources
We have a large library of product resources including success stories, product and support videos, articles, as well as complete product
catalogs and product reference maps to assist when looking for the switching, simulation and cable and connector solutions you need.
We have also published handy reference books on Switching Technology and for the PXI and LXI standards.
To view, download or request any of our product resources, please visit: pickeringtest.com/resources

Page 1.6 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
SECTION 1 - TECHNICAL SPECIFICATION
THIS PAGE INTENTIONALLY BLANK

Page 2.1
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 2 - TECHNICAL DESCRIPTION
SECTION 2 - TECHNICAL DESCRIPTION
FUNCTIONAL DESCRIPTION
A functional block diagram is provided in Figure 2.1. The Module is powered by the +5V and +3.3V supplies from the
PXI backplane via Compact PCI connector J1. The interface to the user’s equipment is via the front panel mounted
25-pin male D-type connector, J2.
The module comprises a single PCB populated with 1-pole electro-mechanical relays congured as a single 16x4
(40-549-001), single 8x8 (40-549-002), dual 8x4 (40-549-003) or a single 8x4 (40-549-004) matrix. The relays
are energised via control signals from relay drivers U17 to U20. Each relay driver is loaded with serial data from
PCI bridge U1 to operate the required matrix crosspoint via digital isolators U21 and U22. Module conguration is
determined by data stored in Serial EPROM U3. PCI Bridge U1 is congured by Flash EPROM U2.
X2
X4
X8
X1
X3
X5
X6
X7
X12
X9
X10
X11
X14
X16
X13
X15
Y2
Y4
Y1
Y3
MATRIX
CROSSPOINT
25-PIN
D-TYPE
CONNECTOR
MODULE
CONFIGURATION
U3
PCI
BRIDGE
U1
PCI BRIDGE
CONFIGURATION
U2
TERMINATING
RESISTORS
R1 TO R12
COMPACT PCI
BUS
CONNECTOR
J1
+3.3V
0V
RELAY
DRIVERS
U17, U18,
U19, U20
RELAY CONTROL
RELAY CONTACTS
RL1 TO RL64
DIGITAL
ISOLATORS
U21, U22
+5V
16X4 MATRIX
Figure 2.1 - 5 Amp Single 16x4 Power Matrix Module 40-549-001: Functional Block
Diagram (the -002, -003 and -004 versions are functionally the same but are congured
as single 8x8, dual 8x4 and single 8x4 matrices respectively)

Page 2.2 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
SECTION 2 - TECHNICAL DESCRIPTION
THIS PAGE INTENTIONALLY BLANK

Page 3.1
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 3 - INSTALLATION
Page 3.1
REED RELAY MODULE 40-110/115/120/125
pickering SECTION 3 - INSTALLATION
kg
PREOPERATION CHECKS (UNPACKING)
1. Check the module for transport damage and report any damage immediately to Pickering Interfaces.
Do not attempt to install the product if any damage is evident.
2. Position the chassis relative to any other equipment the module(s) will connect with. Ensure the chassis is not
connected to the electrical supply.
3. Ensure that the designated area for the chassis containing the module is of at and solid construction to
withstand and support the combined weight of the module(s) and chassis.
SECTION 3 - INSTALLATION
!
Refer to the Warnings and Cautions at the front of this manual
Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only.
Figure 3.1 - Installing the Module into a PXI/cPCI/LXI Chassis
PXI / LXI Chassis

Page 3.2 5 AMP POWER EMR MATRIX MODULE 40-549
pickering
SECTION 3 - INSTALLATION
Page 3.2 REED RELAY MODULE 40-110/115/120/125
pickering
SECTION 3 - INSTALLATION
SOFTWARE INSTALLATION
First install the appropriate Pickering PXI switch card drivers by running the installer program Setup.exe (provided
in a compressed zip le), either from the CD-ROM supplied, or by downloading the latest version from our website
pickeringtest.com - the recommended method. Setup is accompanied by a ReadMe le containing
additional installation information. A single installation covers all cards in the System 40, System 45 and System
50 ranges.
When installation completes, the installed drivers’ ReadMe le is offered for display. It can also be displayed
later using a shortcut on the Programs>>Pickering menu.
If you are not a LabVIEW user you should choose the “full” version, and once that has been installed run
the LabVIEW Runtime Engine installer via the shortcut on the Programs>>Pickering menu. In the absence of
LabVIEW the Runtime Engine is required to support the Pickering Test Panels application.
!
HARDWARE INSTALLATION
ELECTRICAL CONNECTION (CHASSIS)
1. The chassis must be electrically installed in accordance with local regional electrical codes by a qualied
engineer.
2. The chassis must be grounded.
Electrostatic discharge can damage the components on the module. To avoid such damage in handling the
board refer to page VII.
Ensure that there is adequate ventilation.
The module should be installed in accordance with the following procedure:
1. Ensure that the system is turned OFF but still connected to mains so that it remains grounded.
2. Choose an appropriate slot in the rack.
3. Remove the blanking plate for the chosen slot.
4. Ensure that the injector/ejector handle is in its downward position. Align the module with the card guides on
the top and bottom of the slot.
Do not raise the injector/ejector handle whilst inserting the module as the module will not insert properly.
5. Hold the handle whilst slowly sliding the module into the card guides until the handle catches on the injector/
ejector rail (refer to Figure 3.1).
6. Raise the injector/ejector handle until the module rmly seats into the backplane. The front panel of the
module should be ush with the front panel of the chassis.
7. Secure the front panel of the module using both screws to the chassis front panel mounting rails.
8. In a system employing a remote control interface to connect an external controller to a PXI chassis or to link
multiple chassis, power-up the system as follows:
a. For a system comprising an external controller and one chassis, power up the chassis before powering up
the external controller.
b. For a system comprising more than one chassis, turn ON the last chassis in the system followed by the
penultimate, etc, and nally turn ON the external controller or chassis containing the system controller.
9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up
sequence.

Page 3.3
5 AMP POWER EMR MATRIX MODULE 40-549
pickering SECTION 3 - INSTALLATION
Page 3.3
REED RELAY MODULE 40-110/115/120/125
pickering SECTION 3 - INSTALLATION
Figure 3.3 - General Soft Front Panel Selector
TESTING OPERATION
After installation of the hardware and Pickering PXI Driver software package start the General Soft Front
Panel (GSFP) using the desktop icon or via the Start menu (Start Menu-> Pickering Interfaces Ltd ->
General Soft Front Panel).
A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click
on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
Panels can be opened simultaneously for all the installed cards.
More details how to use the GSFP can be found in the manual, via menu Help\Manual
Figure 3.2 - General Soft Front Panel Icon
Table of contents
Other artisan Control Unit manuals
Popular Control Unit manuals by other brands

G.R.A.S.
G.R.A.S. 12HM instruction manual

Valeo
Valeo SC1000 IVECO operating instructions

Becker
Becker BDC-i440 Series Assembly and operating instructions

Texas Instruments
Texas Instruments ADS5296 user guide

CAME
CAME BPT MTMA/08 Programming manual

Roco and Fleischmann
Roco and Fleischmann z21start user manual

Control Techniques
Control Techniques UD77 DeviceNet Startup guide

Weston Precision Audio
Weston Precision Audio H1 Analog Harmonizer user manual

NiceRF
NiceRF RF24L01F20 manual

Santec
Santec Designer Series Installation and Rough-In

STIEBEL ELTRON
STIEBEL ELTRON FEB Operation and installation manual

ICMA
ICMA TAS001 manual