This user manual outlines the intended use of the Aspire Lifecomfort Hybrid Comfort Mattress System.
The intended use constitutes how to achieve maximum comfort whilst maximising safety and efficiency
for care staff and patients alike.
It is IMPORTANT that this user manual is read in its entirety prior to operating the Aspire Lifecomfort
Hybrid Comfort Mattress System. The manual is designed to ensure that patients are equipped with
the information required to competently and responsibly operate the user’s mattress and pump.
It is recommended that the user manual be kept in an easily accessible place for quick reference.
If required, Aidacare product specialists can provide additional training.
All WARNINGS and CAUTIONS within this manual should be strictly adhered to. Failure to do so could
result in harm to the patient or operator.
CAUTIONS highlighted throughout this manual identify possible hazards in procedures or conditions,
which if not followed correctly could result in equipment damage, or failure.
WARNINGS highlighted throughout this manual identify possible hazards in procedures
or conditions which if not followed correctly could result in serious injury, or fatality.
General
1. Electrical equipment can be hazardous if used incorrectly
2. Residual Current Devices (RCD) are not supplied with Aspire Lifecomfort Hybrid Comfort Mattress
Systems. Please consult with your Biomedical Engineer/advisor concerning RCD requirements
3. The clinically qualified person responsible should consider the age, size and condition of the patient
before using the Aspire Lifecomfort Hybrid Comfort Mattress System
4. The maximum safe working load for the Aspire Lifecomfort hybrid Mattress System is:
• Single = 30-230kg
• King Single = 30-230kg
• Bariatric = 30-380kg
5. This mattress is not to be used on top of a pre-existing support surface. This is a Mattress
Replacement so there is no need for a static foam mattress or pressure safety underlay to be located
underneath, this mattress can go directly onto the bed platform
SAFEGUARD DESCRIPTION
To reduce the risk
of electrocution
1. Occupants should not operate the product at any time. Always ensure that the
pump is unplugged when not in use.
2. Do not disassemble the pump at any time.
3. Do not place or store the pump close to water or any other liquid.
4. Do not submerge the pump in water or any other liquid.
5. Do not make contact with the pump if it has come into contact with water
or any other liquid, unplug immediately.
To reduce the risk of
burn, electrocution,
fire or injury to
the patient
6. When powered mode is to be used, the mattress will become active by connecting
it to the pump. Ensure the pump is not turned off or unplugged whilst in use.
7. Always ensure that warning labels are adhered to ensuring that voltage is correct,
approved power cords are used and that Children & Animals do not come into
contact with the packaging materials that could cause suffocation.
8. Equipment is not suitable to be used in the presence of a flammable anaesthetic
mixture with air, oxygen or nitrous oxide.
9. Keep away from sharp objects.
10. Close supervision is necessary when this product is used by, on, or near children
or people with disabilities.
11. Use this product only for its intended use as described in the user manual. Do not
use attachments not recommended by Aidacare.
12. Do not operate this product if the pump has a damaged power cord or plug, not
working properly, has been dropped or damaged or dropped/submerged into
water or another liquid. If this occurs, contact your Aspire dealer immediately for
a product inspection.
13. Keep the power cord away from hot surfaces.
14. Do not block the air valves/tubes/openings by placing on a soft surface such as a
bed or couch. Keep all valves/tubes/openings responsible for air flow, clear of all
lint, hair and other particles.
15. Do not insert any object into the air valves/tubes/openings.
16. Avoid dropping pump and do NOT mount any heavy objects on top of it.
17. Place the power cord and air hoses at the occupant’s foot area to avoid strangling
of the occupant’s neck.
18. Avoid electromagnetic interference by ensuring that electro-magnetic or RF
generated equipment is kept away from the occupant.
19. Over the course of operation, the pump will generate a small amount of heat.
DO NOT maintain skin contact with pump for more than 1 minute at a time. Never
cover the pump when it is in use, ensure air flow to pump is free at all times.
20. During a power outage or loss (even if only temporary) the pump will stop and
power failure alarm will sound for up to 20 seconds. The pump will return to normal
operation once the power supply is resumed.
21. Connect this product to a properly grounded power outlet only.
22. Avoid the risk of electrocution by grounding the ground pin with grounding
power outlet.
23. The EMC specification is compliant with all regulations and requirements. For
power leads with a ground pin, the connection with properly grounded power
outlets will suppress the EMC effect. The pump will work correctly for power leads
that are not grounded.
2. SAFETY PRECAUTIONS 3. PRODUCT SAFEGUARDS