AQD6 Series 12V/24V Power Supply/Charger
Features
Small –Light –Efficient –Clean Power
Field Selectable AC Input: 120/240 VAC
12 VDC at 6A / 24 VDC at 6A, Selectable
Tolerates brownout or overvoltage input ± 15% of nominal voltage
High efficiency: 90% at 25V output, full load
Battery Charger Maximum Charge Current: 0.7A
Dedicated battery charging circuit for Wet, AGM, and Sealed Lead
Acid Battery(s)
Power Limited Output with Thermal Protection
Reverse Battery Protection
Battery Online, No Drop or Switchover with AC Power Fail
Quality Manufactured in the USA
UL Listed Access Control & Burglar Alarm systems
Set of Form “C” Relay Contacts Indicates AC Power Status
Set of Form “C” Relay Contacts Indicates Low Battery
Amber LED Indicates Power Normal
DC Output is Class II Power Limited
Lifetime Warranty
Ordering examples:
AQD6B
Supervised Power Supply/Charger module without an enclosure.
AQD6
Supervised Power Supply/Charger module with a 14” x 14”x 4.75”enclosure.
-8F
-8C
-16F
-16C
-8F8R
-8C1R
AQD6 with one PDB-8F
AQD6 with one PDB-8C
AQD6 with two PDB-8F
AQD6 with two PDB-8C
AQD6 with one PDB-8F8R
AQD6 with one PDB-8C1R
Description
The AQD6 series are heavy-duty, self-contained, efficient, clean,
offline switching power supplies, with linear-type performance,
and are jumper selectable between 12 VDC at 6A and 24 VDC
at 6A. The AQD6 series have a dedicated lead acid battery(s)
charger that obtains maximum battery life while providing 12
VDC or 24 VDC uninterruptible power for access control security
systems. The field selectable AC input allows these power
supplies to be powered anywhere in the world. The AQD6
series have exceptional brownout capability with operation down
to 85% of nominal voltage. The AQD6 series have an extensive
filtering system that provides linear output performance, and
they are electronically protected against battery reversal,
shorting, or overloading. Power limited output with thermal
protection is available with Models AQD6-8F, AQD6-8C,
AQD6-16F, AQD6-16C AQD6-8F8R, and AQD6-8C1R; non-
power limited in Model AQD6. Each of these protective features
will self-restore.
NOTE: Before connecting load and battery(s), the 12V/24V jumper
is moved to the desired voltage.
AQD6-16C
Securitron
Phoenix, AZ 85044
Tel: 1-800-624-5625
Mon-Fri: 6:00am - 4:00pm PDT
Fax: 1-800-232-7329
www.securitron.com
500-33520, Revision B Page 2 of 4
CAUTION
Damage can occur when switched with DC output load.
Proper voltage must be confirmed before connecting
devices.
The AQD6 series are UL Listed and have additional supervisory
features:
Battery disconnect relay when battery(s) are depleted
Set of Form “C” relay contacts that indicate AC power
failure
Set of Form “C” relay contacts that indicate low battery(s)
DC Output is Class II power limited.
Depending on load, low battery trouble indicates 50–75% battery
capacity remaining. Input wiring to the unit should be enclosed
in conduit secured firmly to the enclosure. The AQD6 cannot be
used to power a mercantile bell.
Specifications
AC Input: L, N, G - 3P Terminal block
Safety block with recessed hardware insulation accepts up to
12 AWG
L= Line, N= Neutral, and G = Ground
AC Input .........................................................120–240 VAC / 240W
AC Input Frequency…………………… ............................50 to 60 Hz
AC LED Indicator (Panel mounted on the enclosure door)
The AC indicator is a green LED. This LED off with AC at the terminals
would indicate a blown fuse link. A blown AC fuse link would indicate
catastrophic failure and must be returned to the factory for repair.
AC Input Voltage Selection
CAUTION
To prevent damage, the power supply board must be configured for
the proper voltage before applying line voltage.
NOTE: Once the link is cut, there is no conversion back to 120 VAC.
There is a removable link located at the top right of the power supply
board. This link is cut and removed to convert to 240 VAC.
DC Output Voltage Selector Jumper
CAUTION
To prevent damage, the DC load and battery(s) connections are
removed before switching selector switch up or down.
The jumper is slightly left of center near the AC terminal block, and is
marked with “VOLTAGE SELECT 12V / 24V”. The jumper is moved to
the appropriate pins to configure the output voltage.
DC Outputs: 2P Terminal block
NOTE: There is up to a 10-second delay for initial turn on.
Output voltage Nominal ............................................12 VDC / 24 VDC
Output voltage Typical ........................................ AC on 12.5V / 25.0V
Output range with rated load .............12.0–13.0 VDC / 24.5–25.5 VDC
Output range on battery power...........9.79–13.2 VDC / 19.6–26.4 VDC
Output continuous current (UL rating)............................................... 6A
Load regulation no load to max (no battery) ...............................±0.2%
Output ripple full load ...........................................................240 mV pp
Current Overload Short Circuit Protection ......................................Yes
Thermal runaway Protection ...........................................................Yes
Power Limited Output with Thermal Protection for Models AQD6-8F,
AQD6-8C, AQD6-16F, AQD6-16C, AQD6-8F8R, and AQD6-8C1R.
Non power limited for Model AQD6
Current Overload and Thermal shutdown will auto-restart without
removing load.
Ambient operating temperature range .........................-20oC to +50oC
Product was not evaluated at UL for outdoor use.
DC LED Indicator (Adjacent to DC terminal block) .....................Green
Battery Charging: (2P Terminal block marked [–Bat+])
CAUTION
To avoid spark, AC must be applied before connecting battery cable
to battery.
Fault reporting relay rating: 32 VDC, 120 VAC, 1A
The battery charger is precision set to float charge 12V or 24V sealed or
wet lead acid batteries. A 12-inch battery cable assembly is provided
that plugs from module to battery: Red (+), Black (–) Neg.
Battery(s), any type of lead acid ......................12V / 24V, 4 AH–40 AH
UL evaluated .....................................................................72AH
Battery(s) recharge .........................................................700 mA max
Battery(s) average recharging current .....................................250 mA
Battery(s) PTC self-resetting circuit breaker .............................6A PTC
Battery(s) Reverse hookup protection ..............................Yes, 4A PTC
To estimate the recharge time in hours for depleted battery(s), the AH
rating is multiplied by 4 (AH x 4). As an example, a 12V system with two
depleted 12V, 7 AH batteries would take about 28 hours to re-charge.
AQD6 Supervised Added Features:
UL Listed
Class II Power Limited .............................Refer to DC outputs section
AC Status Output Relay: 3P Terminal block
AC Fail “C” contacts rating ................................ 32 VDC, 120 VAC, 1A
Three position AC fail terminal block marked “NO, C, NC” are shown in
the Normal, energized, AC ON condition.
Battery LED Indicator .....................................................................Red
Battery Charge
Battery Max. Charge (no load) .........................................13.7V /27.4V
Battery Cutoff internal relay contacts ................. 32 VDC, 120 VAC,1A
Low Battery Cutoff…………….…….. ..... 9V /18 V for 12 V / 24V setting
Battery Cutoff Relay is normally energized for fail-safe operation.
Sealed lead acid batteries have a typical life of 3 to 5 years.
Physical
AQD6 Module Dimensions .........................7.36”L x 4.04”W x 1.75”H
Height includes 7/16” standoffs, not provided with module only.
Mounting Holes Center to Center ............................. 6.44”W x 3.41” H
AQD6 module only weight ........................................................ 12.4 oz
AQD6 in enclosure ......................................................14” x 14” x 3.50”
AQD6 in enclosure weight ........................................................6.85 lbs
UL Approvals for AQD6
UL 294, 6th Edition –Access Control System Unit
Endurance Test Level 1
Attack Test Level 1
Battery Standby Test Level 4
UL 603 –Power supplies for Use with Burglar-Alarm Systems
UL 1481 –Power Supplies for Fire-Protective Signaling Systems
ULC S318-96 –Power supplies for Burglar Alarm Systems
ULC S533-02 –Standard for Egress Door Securing and Releasing
Devices
For ULC-S318-96 compliance, the power supply battery fail line must be
connected to and monitored by a control panel trouble zone.
NOTE 1: The AQD6 uses a standard power supply enclosure, not an
attack proof’ enclosure. As such, the AQD6 should not be
used to power a mercantile bell.
NOTE 2: When using a battery that is not housed inside the power
supply enclosure, the battery leads require protection from
the enclosure via the use of conduit.
NOTE 3: When using the AQD6B in another enclosure, minimum
standard spacing between live electrical circuits shall be
taken into account.
500-33520, Revision B Page 3 of 4
Maintenance
The power supply and stand by battery(s) should be tested at least once a year as follows:
1. CHECK LED’s for normal state:AC ON Green, Trouble Normal ON Green, DC ON Red.
2. CHECK output voltage with normal load (assures proper voltage to float charge batteries): For 12V setting, voltage should
read between 13.6 VDC and 13.8 VDC; and for 24V setting, voltage should read between 27.1 VDC and 27.6 VDC.
3. DISCONNECT AC input: AC LED should be off, and all other LED’s should remain normal.
4. CHECK DC output to be above 12.0 VDC for 12V setting and 24.0 VDC for 24V setting (checks standby batteries to be
operational).
5. APPLY AC and VERIFY AC LED ON.
Battery Selection
The table below shows typical standby time in hours for various loads and batteries. The table works for either 12 VDC or 24 VDC.
The AQD6 was evaluated at UL with a 75 Ah sealed lead acid battery.
Approximate Battery Standby Time Table with a reserve of 6A for 5 minutes for Alarm
Total Output
in
Amps
4 AH
Battery
Standby
7 AH
Battery
Standby
12 AH
Battery
Standby
24 AH
Battery
Standby
40 AH
Battery
Standby
75 AH
Battery
Standby
0.06
53
101
180
371
625
1180
0.125
25
48
86
178
300
566
0.25
13
24
43
89
150
283
0.50
6.4
12.1
21.6
44.5
74.9
142
1
3.2
6.0
10.8
22.2
37.5
71
2
1.6
3.0
5.4
11.1
18.7
35
3
1.1
2.0
3.6
7.4
12.5
24
4
0.8
1.5
2.7
5.6
9.4
18
5
0.6
1.2
2.2
4.4
7.5
14
6
0.5
1.0
1.8
3.7
6.2
12
500-33520, Revision B Page 4 of 4
AQD6 in an enclosure with two PDBs in a 24V Configuration
WARRANTY
The AQD6 is covered by the MagnaCare®lifetime replacement no fault warranty. No registration is required. Product will be replaced
forever, for any reason, including but not limited to installation error, vandalism, or act of God. Replacement product is shipped at
Securitron’s expense next day air, if needed.
For more information, visit www.securitron.com
Securitron is a brand associated with Hanchett Entry Systems, Inc.,
an ASSA ABLOY Group company. Copyright © 2016, Hanchett
Entry Systems, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of Hanchett Entry
Systems, Inc. is prohibited.

This manual suits for next models

7

Other Assa Abloy Power Supply manuals

Assa Abloy SECURITRON BPSS-10 User manual

Assa Abloy

Assa Abloy SECURITRON BPSS-10 User manual

Assa Abloy Securitron AQL4 User manual

Assa Abloy

Assa Abloy Securitron AQL4 User manual

Assa Abloy ADAMS RITE PS-SE Operating instructions

Assa Abloy

Assa Abloy ADAMS RITE PS-SE Operating instructions

Assa Abloy Securitron AQD5 Series User manual

Assa Abloy

Assa Abloy Securitron AQD5 Series User manual

Assa Abloy Securitron BPS-12-1 User manual

Assa Abloy

Assa Abloy Securitron BPS-12-1 User manual

Assa Abloy Securitron AQE30E User manual

Assa Abloy

Assa Abloy Securitron AQE30E User manual

Assa Abloy Securitron AQL6 User manual

Assa Abloy

Assa Abloy Securitron AQL6 User manual

Assa Abloy Securitron AQL102 User manual

Assa Abloy

Assa Abloy Securitron AQL102 User manual

Assa Abloy SECURITRON BPSM-12-6 User manual

Assa Abloy

Assa Abloy SECURITRON BPSM-12-6 User manual

Assa Abloy effeff 1006 Series User manual

Assa Abloy

Assa Abloy effeff 1006 Series User manual

Popular Power Supply manuals by other brands

Yamaha PW800W owner's manual

Yamaha

Yamaha PW800W owner's manual

Elektro-Automatik EA-PS 9080-100 manual

Elektro-Automatik

Elektro-Automatik EA-PS 9080-100 manual

LOVATO ELECTRIC PMVFUPS01 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC PMVFUPS01 instruction manual

MATRIX TECHNOLOGY MPS-H-3 Series user manual

MATRIX TECHNOLOGY

MATRIX TECHNOLOGY MPS-H-3 Series user manual

VTOMAN Jump 1800 user manual

VTOMAN

VTOMAN Jump 1800 user manual

Allen-Bradley 140G-G-PRA Installation

Allen-Bradley

Allen-Bradley 140G-G-PRA Installation

DIS PS 6000 user manual

DIS

DIS PS 6000 user manual

Rohde & Schwarz HMP Series Getting started

Rohde & Schwarz

Rohde & Schwarz HMP Series Getting started

Carrier INFINITY KIT63000 installation instructions

Carrier

Carrier INFINITY KIT63000 installation instructions

Niko 550-00010 quick start guide

Niko

Niko 550-00010 quick start guide

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

Akyga AK-ND-43 user manual

Akyga

Akyga AK-ND-43 user manual

HP procurve switch zl installation guide

HP

HP procurve switch zl installation guide

Navitel NS300 user manual

Navitel

Navitel NS300 user manual

IDEC PS3X Series instruction sheet