6.4 Connect to the Electricity Suppy
Electrical installations must be carried out by a qualified
electrician. Do not attempt to tamper with or access the
electrical control box or casing inside the UV, as doing so
will invalidate the warranty.
The power supply must meet the specifications on the
product. The cores in the supply cable are coloured in
accordance with the following code:
Brown = Live
Blue = Neutral
Earth = Green/Yellow (where fitted)
IMPORTANT: Do not use the supply cable to lift the UV as
this may cause damage.
Section 7. Maintenance
7.1 UV Bulb Replacement
Isolate the unit from any electricity and water supplies before
carrying out maintenance on the unit. It is not necessary to
stop the water through the UV to change the bulb.
Life span of a UV bulb is 9000 hours (approx 1 year continue
running). It is recommended that the bulb is changed during
this running time.
7.1.1 To Remove a UV Bulb
1. Disconnect the electricity supply.
2. Unscrew the black end cap at one end of the unit. Take
care not to unscrew the white locking nut also.
3. Carefully slide the black end cap over the wire to
reveal the bulb socket. Do not lose the end cap sealing
ring.
4. Disconnect the bulb socket.
5. Repeat steps 2 to 4 at the other end of the UV.
6. With the end caps out of the way, carefully slide out
the UV bulb.
7.1.2 To Install a New UV BUlb
1. Refer to the installation of the UV Bulb steps in 6.2.
IMPORTANT: After checking all the ttings are correctly
tightened you can switch your unit back on.
7.2 Replace / Clean Quartz Supply
Always isolate the unit from any electricity and water
supplies before carrying out maintenance on the unit.
7.2.1 To Remove a Quartz Sleeve
NOTE: Removing the quartz sleeve will cause water to
ow out of the unit.
1. Remove the UV bulb.
2. With the electricity supply disconnected, UV isolated
and UV Bulb removed, unscrew the locking nut at one
end of the UV.
3. Water should be drained from the unit.
4. Carefully remove the quartz sleeve O-Ring and keep
safe.
5. Unscrew the locking nut from the other end and
remove the quartz sleeve O-Ring and keep safe.
6. Carefully remove the quartz sleeve taking care not to
allow it to drop inside the UV body.
7. To drain any water that may be left in the unit, we
would recommend that you unscrew the mounting
bracket(s), disconnect the unit from the pipework, and
tilt the unit to drain the chamber of water.
8. Clean the sleeve and polish with a soft cloth or paper
towel. If you live in a hard water area, you may get
limescale on the quartz sleeve; this can be easily
removed by using vinegar or a cold water descaler.
7.2.2 To Re-Install a Quartz Sleeve
1. Refer to the re-installation of the quartz sleeve and
UV bulb in 6.1.
IMPORTANT: After checking all the ttings are correctly
tightened you can switch your unit back on.
7.2.3 Check for Leaking Water
If you notice water leaking from around the end caps, you
should check the following:
1. Check the O-Ring is undamaged.
2. Check there are no cracks and breaks in the quartz
sleeve.
3. Check that the locking nut is compressing the O-Ring
to form a water tight seal.
4. Check that the end caps are suciently tight.
5. All components are clean and free from dirt and
debris.
NOTE: Please note that the items list 1-5 are service items and
therefore not subject to a claim under warranty.
The service items listed are available from your AstralPool
stockist.