The MAS S 50 series encoders operate absolute. In other words, unlike the
incremental systems, they do not lose their positions in power outages and
continue to measure from where they left off.
They are with shaft and they have 50 mm body diameter. The MAS series multi-turn
absolute rotary encoders offer highly flexible solutions in use, with different analog
output signals, shaft diameters and flange types.
The MAS multi-turn absolute rotary encoder with integrated reference provides
high quality feedback.
•The installation of the product is carried out by the customer who purchases the product, according to the wiring
diagrams, installation information, etc. in this manual.
•Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
•There must be minimum distance between the sensor and control unit. Avoid additions except the suitable
connector unless it needs.
•Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies,
inductive and capacitive noisy supplies.
•Shielding edge of the sensor cable must be ground connected.
•For not to damage the sensor, supply directions and voltage must be paid attention. Don’t energize before all
connections completed.
•Transport and storage should be at their original packaging and an ambient temperature of -20°C / + 70°C in such
a way that they will not be exposed to dust, humudity, impact, vibration, falling or water.
•Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped
with a damp cloth.
•The product may be damaged and may become unusable if used outside of the specifications in the user manual.
•The product will be out of warranty if used outside of the specifications in the user manual and opened or
repaired other than authorized services.
RESET: With the reset function you can set the desired location to 0. The reset terminal and GND are short-circuited for about
5 seconds and then disconnected. The sensor then accepts the current position as zero.
DIRECTION CHANGE: You can change the angle increase direction with the direction change function. The direction changing
terminal and GND are short-circuited for about 5 seconds and then disconnected.Thus, the sensor reverses the angle direction
(CW is CCW and CCW is CW).