ATEN VS0104 User manual

VS0102 / VS0104 / VS0108
2/4/8-Port VGA Splitter with Audio
RS-232 Control Tool
V1.0.061
User Manual
www.aten.com

VS0102/04/08 RS-232 Control Tool
2
FCC Information
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the
instruction manual, may cause interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna;
Increase the separation between the equipment and receiver;
Connect the equipment into an outlet on a circuit different from that which
the receiver is connected;
Consult the dealer or an experienced radio/television technician for help.
RoHS
This product is RoHS compliant.
SJ/T 11364-2006
The following contains information that relates to China.

VS0102/04/08 RS-232 Control Tool
3
RS-232 Control Tool Operation
Overview
The VS0102 / VS0104 / VS0108’s built-in bi-directional RS-232 serial
interface allows system control through a high-end controller, PC, and/or home
automation / home theater software package. The RS-232 Control Tool is an
application used to send operational commands from your PC – to the VS0102
/ VS0104 / VS0108 through a serial (RS-232) interface connection. RS-232
serial operations to and from the VS0102 / VS0104 / VS0108 can be managed
using ATEN’s Graphical User Interface (GUI) on computers that are running
the Microsoft Windows operating system. In order to use the RS-232 Control
Tool, two separate programs must be installed on the PC- .NET Framework 2.0
and the RS-232 Control Tool. The procedure for installing and operating the
RS-232 Control Tool is detailed in the following sections.
Before You Begin
Installing .NET Framework 2.0
To install .NET Framework on your PC, do the following:
1. Download the executable file from the ATEN website or the Microsoft
Download Center online, and run it.
2. Follow the instructions on the screen. The installation applet will
automatically detect the operating system and install the correct drivers
Installing the RS-232 Control Tool
To install the RS-232 Control Tool, do the following:
1. Download the RS-232 Control Tool from the Download or VS0102 /
VS0104 / VS0108’s Resource page on our website:
www.aten.com
2. Save the file to a convenient location.

VS0102/04/08 RS-232 Control Tool
4
3. Double click the file to run setup. The Welcome screen appears:
Click Next.
4. The License Agreement appears:
If you agree with the License Agreement, select I agree with the terms of
this license agreement, and click Next.

VS0102/04/08 RS-232 Control Tool
5
5. The User Information screen appears:
Fill in your Name and Company, then click Next.
6. When the Installation Folder screen appears, you can select where you
want to install the program by clicking Change, or use the default
installation location provided, then click Next.

VS0102/04/08 RS-232 Control Tool
6
7. From the Shortcut Folder screen type in or use the drop-down menu to
enter the folder where you want to install the shortcuts.
Then select Install shortcuts for current user only, or Make shortcuts
available to all users, and click Next.
8. At the Ready to Install screen confirm your settings, click Back if you
need to make changes, or click Next to begin the installation.

VS0102/04/08 RS-232 Control Tool
7
9. When the installation has completed successfully, the following screen
will appear:
Click Finish. You are now ready to use the RS-232 Control Tool.

VS0102/04/08 RS-232 Control Tool
8
GUI Main Page
The RS-232 Control Tool is a convenient and intuitive application to send RS-
232 commands to your VS0102 / VS0104 / VS0108. The various elements of
the GUI are described in the following sections. For detailed information about
the function of each RS-232 command, see the VS0102 / VS0104 / VS0108’s
user manual.
To invoke the GUI, simply click the RS-232 Control Tool shortcut. The
interface opens on the Switch Port page by default, as shown below:

VS0102/04/08 RS-232 Control Tool
9
Switch Port
The Switch Port page is used to connect the Video/Audio source to the display
ports, and to power on/off displays.
From the Switch Port page, the following actions are possible:
Select an Output port from the drop-down menu.
Select ON or OFF to turn the selected display port on or off
Use the Refresh button to update the Output port list
Use the text box to manually enter the command.
Click SEND to send the command.

VS0102/04/08 RS-232 Control Tool
10
Switch Port Commands
The actions can also be performed by keying the command into the text box,
and clicking SEND or pressing the [Enter] key, as described below.
The available formulas for Switch Port commands are as follows:
1. Switch Command + Output Command + Port Number + Control
For example, to turn on output port 02, type the following:
sw o02 on
-or-
For example, to turn off output port 01, type the following:
sw o01 off
Possible Values
The following table shows the possible values for the Switch Port commands:
Command Description
sw Switch command.
Output Command Description
o Output command.
Port Number Description
yy 01-08 port (default is 01).
* All output ports.
Control Description
on Turn on the display.
off Turn off the display.

VS0102/04/08 RS-232 Control Tool
11
Switch Port Commands Table:
After commands are sent acknowledge messages are returned.
Note: 1. Each command string can be separated with a space.
2. The Port Number command string can be skipped, and the default
value will be used.
Command Input Port Control Enter Description
sw o yy on [Enter] Turn on display port yy.
sw o yy off [Enter] Turn off display port yy.
sw o * on [Enter] Turn on all displays.
sw o * off [Enter] Turn off all displays.
Ack Description
Command OK Command is correct and function executed.
Command Incorrect Unavailable command or parameters.

VS0102/04/08 RS-232 Control Tool
12
Switch Command for Cascaded Splitters
Serial port commands for cascaded splitters require identifying the chain of
ports to which the target device is connected. The formula for Switch Port
commands in a cascade are as follows:
Switch Command + Output Command + Port Number (at first stage) + Port
Number (at second stage) + Port Number (at third stage) + Control
For the example above, the command for switching off the Target Output Port
4of the splitter connected to Port 3 at the second stage of the cascade, which,
in turn, is connected to output Port 4 at the first stage unit, is as follows:
sw o04-03-04 off
This cascade command format is applied to Mute Commands, page 17, Read
Info Commands, page 20, and Reset Commands, page 23. However, the
cascade commands are not applicable for the Version or EDID commands,
which are only applied to the first stage unit.
First Stage Unit
Second Stage Unit
Third Stage Unit
Target
Output

VS0102/04/08 RS-232 Control Tool
13
EDID Mode
The EDID Mode page is used to set the EDID setting for all displays. The
EDID Mode page provides three options - Port1, Auto, and Default(*), as
described below.
Port1: The EDID from port1 will be passed to the video source for use
with all displays.
Auto: The EDID will automatically be selected and passed to each video
source.
Default: The default EDID will be passed to all video sources.
Use the text box to manually enter the command.
Click SEND to send the command.

VS0102/04/08 RS-232 Control Tool
14
EDID Mode Commands:
The actions can also be performed by keying the command into the text box,
and clicking SEND or pressing the [Enter] key, as described below.
1. EDID Command + Control
For example, to change the EDID setting to Auto, type the following:
edid auto
Possible Values
The following table shows the possible values for the EDID commands:
Command Description
edid EDID mode command.
Control Description
port1 Implement the EDID of the
display connected to Port 1, and
pass it to the video source for
use with all displays.
auto Implements the true EDID remix
of all connected displays. The
VS0102 / VS0104 / VS0108
uses the best resolution for all
displays.
default Implements ATEN’s default
EDID.

VS0102/04/08 RS-232 Control Tool
15
EDID Mode Commands Table
After commands are sent acknowledge messages are returned.
Note: 1. Each command string can be separated with a space.
2. The Port Number command string can be skipped, and the default
value will be used.
Command Control Enter Description
edid port1 [Enter] The EDID from Port 1 is passed to the
video source for use with all displays.
edid auto [Enter] The VS0102 / VS0104 / VS0108
implements the true EDID remix of all
connected displays and uses the best
resolution for all displays.
edid default [Enter] ATEN’s default EDID is passed to the
video source.
Ack Description
Command OK Command is correct and function executed.
Command Incorrect Unavailable command or parameters.

VS0102/04/08 RS-232 Control Tool
16
Mute
The Mute page is used to turn audio on or off for an output port. On the Mute
page, the following actions are possible:
Select an Output port from the drop-down menu.
Click ON to mute the selected port.
Click OFF to enable the audio of the selected port.
Use the text box to manually enter the command.
Click SEND to send the command.

VS0102/04/08 RS-232 Control Tool
17
Mute Commands:
The actions can also be performed by keying the command into the text box,
and clicking SEND or pressing the [Enter] key, as described below.
1. Mute Command + Output Command + Port Number + Control
For example, to mute the audio for output port 04, type the following:
mute o04 on
-or-
For example, to turn on the audio for output port 04, type the following:
mute o04 off
Possible Values
The following table shows the possible values for the Mute commands:
Command Description
mute Mute command.
Output Command Description
o Output command.
Port Number Description
yy 01-08 port (default is 01).
* All ports.
Control Description
on Mute on; audio of output port is
disabled.
off Mute off; audio of output port is
enabled (default).

VS0102/04/08 RS-232 Control Tool
18
Mute Commands Table
After commands are sent acknowledge messages are returned.
Note: 1. Each command string can be separated with a space.
2. The Port Number command string can be skipped, and the default
value will be used.
Command Output Port Control Enter Description
mute o yy on [Enter] Mute on for output port
yy (no audio).
mute o yy off [Enter] Mute off for output port
yy (audio on).
mute o * on [Enter] Mute on for all ports (no
audio).
mute o * off [Enter] Mute off for all ports
(audio on).
Ack Description
Command OK Command is correct and function executed.
Command Incorrect Unavailable command or parameters.

VS0102/04/08 RS-232 Control Tool
19
Read Info
The Read Info page is used to get configuration information from the VS0102
/ VS0104 / VS0108, which is displayed in the large text box on the center of
the page. On the Read Info page, the following actions are possible:
Select an Output port from the drop-down menu.
Select Version to display the VS0102 / VS0104 / VS0108’s firmware
version.
Select EDID to display the current EDID setting for all ports.
Select Video to display the current on/off video status of a port.
Select Audio to display the current on/off audio status of a port.
Use the text box to manually enter the command.
Click SEND to send the command.

VS0102/04/08 RS-232 Control Tool
20
Read Info Commands:
The actions can also be performed by keying the command into the text box,
and clicking SEND or pressing the [Enter] key, as described below.
1. Read Command + Control
For example, to read the firmware version, type the following:
read version
2. Read Command + Output Command + Port Number + Control
For example, to display the video on/off status for port 03, type the following:
read o03 video
Possible Values
The following table shows the possible values for the Read Info commands:
Command Description
read Read info command.
Output Command Description
o Output command.
Port Number Description
yy 01-08 port (default is 01).
* All ports.
Control Description
version Read firmware version.
edid Read EDID information
(For port 01 only).
video Read video on/off status.
audio Read audio on/off status.
This manual suits for next models
2
Table of contents
Other ATEN Accessories manuals
Popular Accessories manuals by other brands

Metrix
Metrix 5534 installation manual

Timeguard
Timeguard RCD01WAVN Installation & operating instructions

Silvercrest
Silvercrest Z32138 Assembly, operating and safety instructions

Chef's Choice
Chef's Choice Chef'sChoice 316 instructions

H.Koenig
H.Koenig BW1890 instruction manual

Glastender
Glastender ST24 Operation manual