How to use the door intercom.
When a visitor comes to the entrance, he dials # and your telephone number (or
presses the button with your name, if a ADI-623-08 is connected).
Answer you telephone. During the call you will hear a beep every 5:th second to
indicate that the call comes from the entrance.You now have _____sec. to talk to the
visitor. If you want to open the door for the visitor press the five-button and hang
up. 15 sec. before you are disconnected, you get a warning signal. If you want to
extend the connection with _____sec. Press the 2 button.
At the entrance you can always break the call by using the * button.
The possibility to open the door with the 5-button is enabled during the following
times:
If you don’t want to let the visitor into the building, press zero and hang up.
Fill in and copy this form and distribute it to whom it may concern.

AXCALL
2
AXCALL DI-623-21L
1. INTRODUCTION
Axcall DI-623-21L is a door intercom to be connected to a company’s internal switch-
board. This makes it possible to get in contact with all telephones from the entrance.
A person can talk to the visitor at the entrance and also open the door. The door
intercom also has a codelock function, which can be used by none-visitors. The
possibility to use call numbers and codes can be time controlled by an external timer.
To use DI-623-21L the switchboard has to have ananalogue two-wire connection. To
be able to use the opening function the switchboard also must use Dual Tone Multi-
Frequencysignalling (DTMF) to the door intercom.
DI-623-21
SWITCH-
BOARD
4
6
8
0
2
1
3
5
7
9
#
The green LED on the front panel indicates “door open” and the yellow indicates
“key pressed”. The red LED lights constant when you are connected to the switch-
board and flashes when the line is occupied by another telephone connected to the
same line. When red LED is flashing also see Point 10 side. 8.
To open the door you enter a valid code.
To call on a person you dial #and the telephone number. To prevent improper use,
the length of the number is limited to a programmable number of digits.
DI-623-21
ADI-623-08
You can also have a “direct number button” by connecting one or more ADI-623-08
(max 64 buttons). In this case you have to program the telephone number in the
memory. Button 1 activates the number in memory address 101, button 2 address 102
etc. The number that can be dialled with a “direct button” has a fixed limit of 14 digits.

AXCALL
3
A separate button connected to terminal PL1:6 could even activate memory address
101 to get you in touch with the reception.
Note! If the red LED starts flashing when you make a call, you have forgotten to
connect the telephone line or the line is occupied.
It’s also possible to make a call to the entrance. Dial the number and the intercom
answers automatically and you can talk to the visitor. This function is disabled by
putting the jumper in OFF-position (see page 10). As delivered the jumper is normally
in OFF-position.
Note: If more intercoms are connected to the same telephone line, the jumper must be
in OFF-position.
2. INITIALISATION AND PASSWORD
After installation the unit has to be initialised with a special code. This code pre-sets
printer parameters, clears the memory including the password sets the opening time
to 7 sec. and sets the time of call to 60 sec. The code is 199200.
INITIALISATION AND MEMORY RESET
- Open the door unit.
- Press and release RST-button on the circuit board and wait for four short
beep.
- Enter 199200.
- Press #. 6 short signals are heard. Note: The memory is cleared!
To be able to program the unit and to get information out from it you do need a
password. This password is a six-digit code.
SET PASSWORD
- Press and release RST-button on the circuit board and wait for four short
beep.
- Enter a 6-digit code.
- Press # and you hear two short and one long. Your password is set.
- Press * and close the door unit.
The following codes are not permitted: 00 00 00, 19 92 00 - 19 92 99 You can nei-
ther use a password which contains a telephone number you are going to use.

AXCALL
4
3. PROGRAMMING OF TELEPHONE NUMBERS* AND CODES
* Only if direct buttons (ADI-623-08) or PL1:6 are to be used
DI-623-21L has the possibility to store 99 codes and/or telephone numbers. These are
stored at fixed addresses, 101 to 199, and could be 1 to 14 digits. You should make a
log of what is stored at which address. Each code could be combined with one of two
functions:
< 1> - ControlsRelay 1 monostable.
< 2> - Stores astelephone number.
You can also program the code/ direct buttons so they are possible to disable by an
external timer. The disable functions are:
< 0 > - No time control
< 1 > - Code disabledif PL2:15 PL2:16 is open.
< 2 > - Code disabledif PL2:15 PL2:16 is closed.
Programming is done in the following way:
- Enter your password. You will hear a beep every second.
- Press #and the address for the fist code/number which is101, and you hear a
double beep.
- Enter a code/number with optional number of digits (max. 14).
- Press #, and you hear a double beep.
- Enter a function (1-2), and you hear a double beep.
- Enter a disable function (0-2), and you hear two short and one long. The code
is now stored in the memory and the unit returns to programming mode.
- Press *. The unit returns to working mode.
Example 1: Program a 3-digit telephone number (209), which should not be time-
controlled (0).
- Enter yourpassword.
- Press # 101 209# 2 0
- Press *. The unit returns to working mode.

AXCALL
5
Example 2: Program a code (# 154) with 4 digits (5678) which should be disabled if
PL2:15 PL2:16 is closed. (2).
- Enter your password.
- Press # 154 5678# 1 2
- Press *. The unit returns to working mode.
If you enter more codes you only have to press * when the programming is finished,
and not after each code. * also works as "break" during programming.
The programmed codes/numbers and their functions could be checked withprintout
# 82.
Note: If a code/number is included in the six digit password, e.g. if your password is
123456, and an 1234 is a door code, the door will open on 1234 and the code lock will
enter programming mode after 6 digits.
4. CANCEL CODES/TELEPHONE NUMBERS
If you want to cancel number or a code e.g. code 1, do the following:
- Enter your password.
- Press # 101 # #.The code is erased and the code lock returns to programming
mode.
- Press *. The unit returns to working mode.
5. PROGRAMMING OF TIME OF RELAY AND CALL
Enter opening in seconds(default value 7 sec.).
- Enter your password. You will hear a beep every second.
- Press # 51 double beep < 01-99> and you hear two short and one long.
- Press *. The unit returns to working mode.
Ex: # 51 07 = 7 seconds
Enter opening in minutes.
- Press # 52 instead of # 51.

AXCALL
6
Enter time of call in seconds(default value 60 sec.).
- Enter your password. You will hear a beep every second.
- Press # 53 double beep < 01-99> and you hear two short and one long.
- Press *. The unit returns to working mode.
Ex: # 53 60 = 60 seconds
Enter time of call in minutes.
- Press # 54 instead of # 53.
6. PROGRAMMING OF SPECIAL FUNCTION
As mentioned in the introduction you may open the door from your telephone. This
is done by pressing 5 on the keypad. By programming #39 and the first of two func-
tion digits, you can chose if and when this function is activated. (#39 is set to 04 by
default or by reset).
The first function digit which controls the “open with 5”-function is:
< 0> - Always activated
< 1> - Disabledif PL2:15 PL2:16 is open.
< 2> - Disabledif PL2:15 PL2:16 is closed.
< 3> - Always disabled.
To prevent a person to call a number outside the company, you can limit the length
of the number that can be dialled from the keypad. Numbers that are programmed in
the memory are not influenced. The limit is set by programming a second digit after
#39. This digit can be between0and 9.
Example 3: Program so that open door with five always work (0) and that the length
of the telephone number is maximum 3 digits (3).
- Enter your password.
- Press # 39 0 3
- Press *. The unit returns to working mode.
After initialisation “open with five” is set toalways work and the length of number is
set to 4 digits. You may reset this default set-up by programming # 39 #. If you pro-
gram #39x0, it means that you only can use programmed direct buttons.

AXCALL
7
7. PROGRAMMING OF UNIT-ID
If you have more than one door unit the printer outputs can be connected in parallel
to one printer or PC. To be able to know to which unit the printout belongs, you must
give all units a unique number. This is done in the following way:
- Enter your password.
- Press # 44 and you hear a double beep.
- Enter a 2-digit number (01-99) and you hear two short one long.
- Press *. The unit returns to working mode.
8. PRINTOUT
Printout of codes, telephone numbers and functions is done with# 82.
- Enter your password.
- Press # 82, system data, codes/numbers, there addresses and functions are
printed out.
Example of printout:
The printout shows that this is a DI-623-21L software version 1.0 with the unit-ID 01.
The second line indicates that the “open with five”-function is disabled and that the
length of the calling number is 4 digits. Line 3 shows that the opening time is 7 sec.
and line 4 that the time of call is 60 sec. Line 5 shows that if you if you close PL1:6
and PL2:16, or if you press button one on a connected ADI-623-08 the number 722 40
00 is called and that this function not could be time controlled. Finally line 6 indicates
that 1234 is an access code that could not be time controlled.
9. TECHNICAL DATA
Power supply: 12 - 24VDC
12 .- 18VAC
Power consumption: 25mA (idle)
100mA (max)
Max load
of relay contacts: 30VDC 2A
Printer output 1200 baud

AXCALL
8
Installed by Company: ....................................................
Name: ..........................................................
Telephone: ..................................................
Password: ..................
10. ADDITIONAL PROGRAMMING
Besides what’s earlier mentioned in this manual, there are two functions that could be
reprogrammed. The short beep that comes every5:th second can be disabled, and the
line test during calling can also be disabled.
The first function, disable the beep is up to the user to decide whether it’s disturbing
or not. Line test need to be disabled in some cases, e.g. if the power on the line is to
low (below app. 20V = red LED flashes), or in the case the PABX detects the break as
an impulse 0:a ( dead or fault connection).
Following settings is possible:
0 = Disabledbeep andEnabledline test.
1 = Enabledbeep andEnabledline test. (default at 199200).
2 = Disabledbeep andDisabledline test.
3 = Enabledbeep andDisabledline test.
For setting:
- Disconnect the power.
- Press and hold the button on front keypad corresponding to the setting you
want.
- Connect the power, when holding the button.
- Release the button and the setting is stored in memory.
Note! At reset 199200 function (1) is set.

AXCALL
9
SHORT FORM PROGRAMMING GUIDE FOR DI-623-21L
CLEAR
MEMORY PASSWORD
TELEPHONE NUMBER*/CODES
only if DI-608 or PL1:6 is used
Enter Delete
PRINTOUT
OPENING
TIME
TIME OF
CALL UNIT- ID
SPECIAL-
FUNCTION
RST-button
RST-button
PasswordPassword
Password
Password
Password Password
Password
199200 # 6-digit code # # 101-199
#39
1-14 digits #
Function
Disablefunction
Disable five
*
*
*
*
*
*
# 101-199
#82
# 51(sec)53(min)
# 52(sec)54(min) # 44
01-99
01-99 01-990-9
Limit number l.
# #

AXCALL
10
CONNECTION OF DI-623-21L
1
+
2 3 4 5 6 7 8 9
10
15
16
17
18
19
20
21
22
23
24
Normally in
position A.
Disable Intercom
answering
_
+
12V
24V
Electriclock
Telephone line
Connection
of DI-608
Speaker
volume
K1
TxD
GND
RxD
Busy
Tamper
AONOFF
Power supply
Connector for prox
reader. See manuals
for each control unit.
B
K4
Voltage
jumper

AXCALL
11
CONNECTION OF DIRECT BUTTONS WITH ADI-623-08
As mentioned in the introduction you can connect one or more ADI-623-08 to a DI-
623-21L to be able to use more direct buttons. The connection is made with the cable
that comes with the ADI-623-08. To light the name labels you also have to connect
power on PL1:1 & 2. ADI-623-08 has 8 buttons that each activates an address in DI-
623-21L. To be able to access different groups of addresses in ADI-623-08 you have
to make an hardware addressing. This is done with the jumpers A0-A2. As delivered
the jumper A0-A2 is set as below (Default). This corresponds to addresses 109 to 116
in DI-623-21L You can see a list of addresses and jumpers in the diagram below. To
change an address you just put A0-A2 so that the right address is achieved.
1
PL1
PL2
TO K1 ON
ADI-623-XX T0 K1 ON
NEXT ADI-623-08
ADI-623-XX PL1:1
ADI-623-XX PL1:2
K1 K2
12V
25
A0 A1 A2
26 272829 30 31 32
24V
2 3 4 5
101-108
Addresses
109-116
117-124
125-132
133-140
141-148
149-156
157-164
A0 A1 A2
Note: Before you connect or disconnect a ADI-623-08 you must disconnect the
power.

AXCALL
12
LIST OF NUMBERS/CODES IN DI-623-21L


Installed by:
Telephone:
Table of contents