manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Axiom
  6. •
  7. Speakers
  8. •
  9. Axiom ED80P User manual

Axiom ED80P User manual

Other Axiom Speakers manuals

Axiom VP100 v2 User manual

Axiom

Axiom VP100 v2 User manual

Axiom T80 User manual

Axiom

Axiom T80 User manual

Axiom Architectural W2 User manual

Axiom

Axiom Architectural W2 User manual

Axiom M0 User manual

Axiom

Axiom M0 User manual

Axiom FMS 16/24 Specification sheet

Axiom

Axiom FMS 16/24 Specification sheet

Axiom VP160 User manual

Axiom

Axiom VP160 User manual

Axiom Vocal Point VP Zero User manual

Axiom

Axiom Vocal Point VP Zero User manual

Axiom AX8000 NEO User manual

Axiom

Axiom AX8000 NEO User manual

Axiom M3 User manual

Axiom

Axiom M3 User manual

Axiom M3 v3 User manual

Axiom

Axiom M3 v3 User manual

Axiom ED150P User manual

Axiom

Axiom ED150P User manual

Axiom Audiobyte User manual

Axiom

Axiom Audiobyte User manual

Axiom QS8 v3 User manual

Axiom

Axiom QS8 v3 User manual

Axiom W2 Specification sheet

Axiom

Axiom W2 Specification sheet

Axiom M2 User manual

Axiom

Axiom M2 User manual

Axiom DEMO9S08LL16 User manual

Axiom

Axiom DEMO9S08LL16 User manual

Axiom W100 User manual

Axiom

Axiom W100 User manual

Axiom LFR1100 User manual

Axiom

Axiom LFR1100 User manual

Axiom Millennia M50 User manual

Axiom

Axiom Millennia M50 User manual

Axiom LFR660 v4 User manual

Axiom

Axiom LFR660 v4 User manual

Axiom Millennia M60 User manual

Axiom

Axiom Millennia M60 User manual

Axiom VP180 v3 User manual

Axiom

Axiom VP180 v3 User manual

Axiom Architectural Series W100 Specification sheet

Axiom

Axiom Architectural Series W100 Specification sheet

Axiom AX12C User manual

Axiom

Axiom AX12C User manual

Popular Speakers manuals by other brands

Electro-Voice LR4S engineering data

Electro-Voice

Electro-Voice LR4S engineering data

Definitive Technology Sound Cylinder user guide

Definitive Technology

Definitive Technology Sound Cylinder user guide

AudioSource LS545 user manual

AudioSource

AudioSource LS545 user manual

Paso C402-T Instructions for use

Paso

Paso C402-T Instructions for use

Altec Lansing 416-8C LF SPEAKER manual

Altec Lansing

Altec Lansing 416-8C LF SPEAKER manual

Kenwood KFC-1072 Servise manual

Kenwood

Kenwood KFC-1072 Servise manual

Peavey ProSys 112 user guide

Peavey

Peavey ProSys 112 user guide

JBL Control Contractor 60 Series installation instructions

JBL

JBL Control Contractor 60 Series installation instructions

Aura STORM-8 owner's manual

Aura

Aura STORM-8 owner's manual

Oontz ANGLE 3 PLUS quick start guide

Oontz

Oontz ANGLE 3 PLUS quick start guide

Electro-Voice LR4A engineering data

Electro-Voice

Electro-Voice LR4A engineering data

Rave RK-650-ICA-B owner's manual

Rave

Rave RK-650-ICA-B owner's manual

Flux Reference Series installation manual

Flux

Flux Reference Series installation manual

Lanzar AQAWBS64BK installation manual

Lanzar

Lanzar AQAWBS64BK installation manual

DAPAudio DCS-6230 manual

DAPAudio

DAPAudio DCS-6230 manual

Aluratek ABS03F quick start guide

Aluratek

Aluratek ABS03F quick start guide

Kenwood KES-5A instruction manual

Kenwood

Kenwood KES-5A instruction manual

Sonance ORIGINAL SERIES instruction manual

Sonance

Sonance ORIGINAL SERIES instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL
ED80P
passive point source loudspeaker
KEY FEATURES
• Near-eld and mid-eld sound reinforcement applicaons • High quality, low distoron drivers
• Asymmetric HF coverage paern • Audiophile-grade passive crossover network
• Rotatable HF Horn for opmal horizontal coverage • 35° monitor taper
• Water-repellent treatment of LF loudspeaker • Various rigging hardware
INTRODUCTION
ED point source systems are designed for indoor and outdoor sound reinforcement applicaons
ranging from clubs, bars and restaurants to theatres, live music venues, houses of worship and theme
environments. Passive ED series loudspeaker systems are easy to set up and simple to operate.
The ED80P consists of an 8” LF drive unit and a 1” HF compression driver loaded by an asymmetric
HF horn in a compact enclosure, designed for many mul-purpose sound reinforcement acvies. The
asymmetric HF coverage paern, varying from 120° horizontal in the lower part of the horn for more
eecve near eld coverage, and narrowing to 60° horizontal at the top of the horn for more focused
coverage in the far eld. The result is more accurate coverage of a typical auditorium than is possible
with a xed horizontal coverage device. The HF horn is also rotatable through 90° by simply removing
four screws and realigning the horn, so that coverage can also be opmised for stage monitor use. This
rotatable horn feature also makes it possible to maintain the ideal coverage paern when the cabinet
is installed in a horizontal (landscape) orientaon. Its asymmetric dispersion paern provides opmal
coverage of typical rectangular venues, with wider dispersion at the front and narrower dispersion at
the rear.
This versale loudspeaker can also be used as a low prole stage monitor with its 35° tapered side,
and in this situaon the HF horn can be rotated to maintain the best coverage paern for performers
both near to and further away from the monitor. ED80P cabinet is an unobtrusive and compact format
designed for a multude of near eld applicaons such as theatre under-balcony ll, stage front ll,
delay speaker, bar and restaurant audio, and discreet stage monitor. A pole mount socket make this a very versale loudspeaker in both portable
and permanently installed applicaons.
TECHNICAL SPECIFICATION
Acouscal
LF Power Compression
@ -10 dB Power (56 W) = 0.5 dB
@ -3 dB Power (280 W) = 1.4 dB
@ 0 dB Power (560 W) = 2.3 dB
System type Point Source Loudspeaker
with asymetric HF Horn
Connectors
Low frequency transducer 8” (200 mm), 2” (50 mm) ISV voice coil, 8Ω Connector Type Neutrik® Speakon® NL4 x 2
Input Wiring Pin 1+/1- (Pin 2+/2- pass thru)
High frequency transducer 1” compression driver, 1” (25 mm) aluminium
voice coil, PEPT diaphragm, 8Ω
Mechanical
Width 250 mm (9.8”)
Height 450 mm (17.7”)
Frequency response 75 Hz – 18 kHz (-6dB) Depth 230 mm (9.1”)
Sensivity (2.83 V @ 1m, 2 Pi) 95 dBSPL Taper angle 35°
Horizontal Coverage Angle 60 to 120° (-6 dB) Construcon 15 mm phenolic birch plywood
Vercal Coverage Angle 55° (-6 dB) Paint Black textured paint (or White)
Maximum Peak SPL @ 1m 124 dB Suspension system
Electrical Suspension Rigging points
Nominal Impedance 8 Ω Oponal brackets
Minimum Impedance 6.1 Ω @ 300Hz Net Weight 8 Kg (17.6 lbs)
Power Handling (AES) 280 W
Power Handling (prgm) 560 W
revision 2017-07-18
h120°
h60°
MECHANICAL DRAWING
OPTIONAL ACCESSORIES
KPTED80B Wall or Truss Mounng “C” bracket.
KPTLTP Wall Mounng bracket.
PLH295 Ø 48-51mm truss tube aluminium half coupler with
M10 x 50 built-in bolt and fastening nut.
NL4FX Neutrik Speakon® PLUG
see hp://www.axiomproaudio.com for detailed descripon and other available accessories.
SPARE PARTS
NL4MP Neutrik Speakon® panel socket 98ED80WZ8 8’’ woofer - 2” VC
91CR0071 ED80P Crossover PCBA 98DRICDX1-1070 1’’ - 1” vc compression driver
25 cm
9.8"
23 cm
9.1"
45 cm
17.7"
Wall
Adapter
Pole Adapter
M8 Flying Point
M8 Flying Point
INSTRUCTION FOR ROTATING THE HORN
1) Remove the speaker grid unscrewing
the four screws indicated below.
turn
90°
2) Unscrew the 4 screws fixing the horn and
rotate the horn by 90°.
REAR PANEL
INPUT - Power input for the external amplier. The ED80P includes a passive crossover for ltering the signal. It includes also an internal protecon
that limits any excessive power to the HF secon and, if the signal persists for a long me, it excludes the HF secon. The connecons are the
following:
INPUT - LINK
NL4 pin number internal connecon
1+ +
1- -
2+ none (pass thru)
2- none (pass thru)
LINK - Power output in parallel with the INPUT socket for connecng the unit to another
speaker. The number of ED80P cabinets that can be connected in parallel depends on the
amplier load capacity.
HORN ORIENTATION
ED80P features an asymmetrical horn that can be rotated in a few minutes for obtaingn the best coverage according to the speaker conguraon.
KPTED80B WALL or TRUSS MOUNTING
Using the “C” shape bracket the ED80P loudspeaker can be installed to walls or mounted to trusses in combinaon combining with a PLH295.
It allows to aim the speaker in one direcon (vercal or horizontal) in 7 steps (-22.5°,-15°,-7.5°,0°,+7.5°,+15°,+22.5°).
VERTICAL POSITION
FOH CONFIGURATION
HORIZONTAL POSITION
FOH CONFIGURATION
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
�ght dispersion
long throw
VERTICAL POSITION
FOH CONFIGURATION
�ght dispersion
long throw
VERTICAL POSITION
FOH CONFIGURATION
wide
dispersion
short throw
wide
dispersion
short throw
�ght
dispersion
long throw
HORIZONTAL POSITION
FOH CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
HORIZONTAL POSITION
FOH CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
�ght dispersion
long throw
wide dispersion
short throw
�ght
dispersion
long throw
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
wide
dispersion
short throw
wide
dispersion
short throw
�ght dispersion
long throw
wide
dispersion
short throw
LIMITED WARRANTY
Proel warrants all materials, workmanship and proper operaon of this product for a period of two years from the original date of purchase. If any defects are found
in the materials or workmanship or if the product fails to funcon properly during the applicable warranty period, the owner should inform about these defects the
dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed descripon. This warranty does not extend to damage resulng from
improper installaon, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned units, and when the unit has been properly used and warranty is sll
valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible for any “direct damage” or “indirect damage” caused by product defecveness.
• This unit package has been submied to ISTA 1A integrity tests. We suggest you control the unit condions immediately aer unpacking it.
• If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspecon.
• Proel is not responsible for any damage that occurs during shipment.
• Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
• Possible damages to unit should be immediately noed to forwarder. Each complaint for package tampered with should be done within eight days from product
receipt.
SAFETY INSTRUCTIONS
– To reduce the risk, close supervision is necessary when the product is used near children.
– Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
– This product should be site away from heat sources such as radiators, lamps and any other device that generate heat.
– This product should be located so that its locaon or posion does not interfere with its proper venlaon and heang dissipaon.
– Care should be taken so that objects and liquids do not go inside the product.
– The product should be connected to a power supply mains line only of the type described on the operang instrucons or as marked on the product. Connect the
apparatus to a power supply using only power cord included making always sure it is in good condions.
– WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
– Do not cancel the safety feature assured by means of a polarized line plug (one blade wider than the other) or with a earth connecon.
– Make sure that power supply mains line has a proper earth connecon.
– Power supply cord should be unplugged from the outlet during strong thunderstorm or when le unused for a long period of me.
CE CONFORMITY
Proel products comply with direcve EMC 2014/30/CE, as stated in EN 55103-1 and EN 55103-2 standards and with direcve LVD 2014/35/CE, as stated in EN 60065
standard.
PROEL S.p.A. (World Headquarter) - Via alla Ruenia 37/43 - 64027 Sant’Omero (Te) - ITALY
Tel: +39 0861 81241 Fax: +39 0861 887862 www.axiomproaudio.com
KPTLTP WALL MOUNTING
This wall mounng bracket allows to aim the loudspeaker in both horizontally and vercally. The horizontal aiming is free with +/-15° and the
vercal aiming is in 4 steps (0°,-15°,-30°,-45°). The loudspeaker can be mounted horizontally or vercally as in the following gure.