Axiom ED120P User manual

ED120P
passive point source loudspeaker
USER MANUAL
revision 2023-08-31

2
Watch for these symbols:
The lightning ash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure, that may be of sucient magnitude to constute a risk of electric shock to
persons.
The exclamaon point within an equilateral triangle is intended to alert the user to the presence of important operang and
maintenance (servicing) instrucons in the literature accompanying the appliance.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instrucons.
2. Keep these instrucons.
3. Heed all warnings.
4. Follow all instrucons.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any venlaon openings. Install in accordance with the manufacturer’s instrucons.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than
the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, parcularly at plugs, convenience receptacles, and the point where
they exit from the apparatus.
11. Only use aachments/accessories specied by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart
is used, use cauon when moving the cart/apparatus combinaon to avoid injury from p-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of me.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such
as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate normally, or has been dropped.
15. Warning: to reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
16. Do not expose this equipment to dripping or splashing and ensure that no objects lled with liquids, such as vases, are placed
on the equipment.
17. To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
18. The mains plug of the power supply cord shall remain readily operable.
19. This apparatus contains potenally lethal voltages. To prevent electric shock or hazard, do not remove the chassis, input
module or ac input covers. No user serviceable parts inside. Refer servicing to qualied service personnel.
20. The loudspeakers covered by this manual are not intended for high moisture outdoor environments. Moisture can damage
the speaker cone and surround and cause corrosion of electrical contacts and metal parts. Avoid exposing the speakers to
direct moisture.
21. Keep loudspeakers out of extended or intense direct sunlight. The driver suspension will prematurely dry out and nished
surfaces may be degraded by long-term exposure to intense ultra-violet (UV) light.
22. The loudspeakers can generate considerable energy. When placed on a slippery surface such as polished wood or linoleum,
the speaker may move due to its acouscal energy output.
23. Precauons should be taken to assure that the speaker does not fall o a stage or table on which it is placed.
24. The loudspeakers are easily capable of generang sound pressure levels (SPL) sucient to cause permanent hearing damage
to performers, producon crew and audience members. Cauon should be taken to avoid prolonged exposure to SPL in excess
of 90 dB.
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end
of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate
this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users
should contact either the retailer where they purchased this product, or their local government oce, for details of where and
how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms
and condions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

3
LIMITED WARRANTY
Proel warrants all materials, workmanship and proper operaon of this product for a period of two years from the original date of purchase. If any
defects are found in the materials or workmanship or if the product fails to funcon properly during the applicable warranty period, the owner
should inform about these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed descripon.
This warranty does not extend to damage resulng from improper installaon, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned
units, and when the unit has been properly used and warranty is sll valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible
for any “direct damage” or “indirect damage” caused by product defecveness.
• This unit package has been submied to ISTA 1A integrity tests. We suggest you control the unit condions immediately aer unpacking it.
• If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspecon.
• Proel is not responsible for any damage that occurs during shipment.
• Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
• Possible damages to unit should be immediately noed to forwarder. Each complaint for package tampered with should be done within eight
days from product receipt.
CONDITIONS OF USE
Proel do not accept any liability for damage caused to third pares due to improper installaon, use of non-original spare parts, lack of
maintenance, tampering or improper use of this product, including disregard of acceptable and applicable safety standards. Proel strongly
recommends that this loudspeaker cabinet be suspended taking into consideraon all current Naonal, Federal, State and Local regulaons. The
product must be installed be qualied personal. Please contact the manufacturer for further informaon.
DECLARATION OF CONFORMITY
The product is in compliance with:
RoHS Direcve 2011/65/EU and 2015/863/EU, WEEE Direcve 2012/19/EU.
The product is in compliance with:
S.I. 2012/3032 The Restricon of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulaons 2012

4
INTRODUCTION
ED point source systems are designed for indoor and outdoor sound reinforcement applicaons ranging from clubs, bars and
restaurants to theatres, live music venues, houses of worship and theme environments. Passive ED series loudspeaker systems are
easy to set up and simple to operate.
The ED120P consists of an 12” LF drive unit and a 1.4” HF compression driver loaded by
an asymmetric HF horn in a compact enclosure, designed for many mul-purpose sound
reinforcement acvies. The asymmetric HF coverage paern, varying from 100° horizontal
in the lower part of the horn for more eecve near eld coverage, and narrowing to 60°
horizontal at the top of the horn for more focused coverage in the far eld. The result is
more accurate coverage of a typical auditorium than is possible with a xed horizontal
coverage device. The HF horn is also rotatable through 90° by simply removing four screws
and realigning the horn, so that coverage can also be opmised for stage monitor use. This
rotatable horn feature also makes it possible to maintain the ideal coverage paern when the
cabinet is installed in a horizontal (landscape) orientaon. Its asymmetric dispersion paern
provides opmal coverage of typical rectangular venues, with wider dispersion at the front
and narrower dispersion at the rear.
This versale loudspeaker can also be used as a low prole stage monitor with its 35° tapered
side, and in this situaon the HF horn can be rotated to maintain the best coverage paern for
performers both near to and further away from the monitor. ED120P cabinet is an unobtrusive
and compact format designed for a multude of near eld applicaons such as theatre under-
balcony ll, stage front ll, delay speaker, bar and restaurant audio, and discreet stage monitor.
A pole mount socket make this a very versale loudspeaker in both portable and permanently
installed applicaons.
TECHNICAL SPECIFICATION
SYSTEM POWER HANDLING
System’s Acousc Principle Two-way Vented Enclosure
Asymmetric Dispersion
Power Handling (AES) 680 W
Power Handling (prgm) 1360 W
Frequency response 65 Hz – 17 kHz (-6dB)
LF Power Compression
@ -10 dB Power (136 W) = 0.9 dB
Nominal Impedance 8 Ω @ -3 dB Power (680 W) = 2.8 dB
Minimum Impedance 6.2 Ω @ 250Hz @ 0 dB Power (1360 W) = 3.8 dB
Horizontal Coverage Angle 60 to 100° (-6 dB) ENCLOSURE & CONSTRUCTION
Vercal Coverage Angle 60° (-6 dB) Width 360 mm (14.2”)
Sensivity (2.83V @ 1m, 2 Pi) 97 dBSPL Height 610 mm (24”)
Maximum Peak SPL @ 1m 128 dB Depth 310 mm (12.2”)
TRANSDUCERS Taper angle Stage Monitor: 35° - Fronill: 7.5°
Low frequency transducer 12” (300mm), 3” (75mm) ISV aluminium
voice coil, 8Ω
Enclosure Material 15mm, reinforced phenolic birch
Paint High resistance, black or white water
based paint
High frequency transducer
1.4” (35.5 mm) compression driver, 2.4”
(60 mm) aluminium voice coil, Titanium
diaphragm, 8Ω Flying System M10 / M6 ying points or dedicated
metal brackets
INPUT CONNECTIONS Net Weight 18 Kg (39.6 lbs)
Connector Type Neutrik® Speakon® NL4 x 2
Input Wiring Pin 1+/1- (Pin 2+/2- pass thru)
* AES Pink Noise Connuous Power
h100°
h60°
INDEX
INTRODUCTION ...........................4
TECHNICAL SPECIFICATION ..................4
MECHANICAL DRAWING ....................5
OPTIONAL ACCESSORIES ....................5
SPARE PARTS ..............................5
INPUT ...................................6
LINK .....................................6
HORN ORIENTATION........................6
KPTED120B WALL or TRUSS MOUNTING........7
KPTLTP WALL MOUNTING ...................7

5
MECHANICAL DRAWING
OPTIONAL ACCESSORIES
KPTED120B Wall or Truss Mounting “C” bracket for
horizontal or vercal aiming at 15 steps in +/-
70° range.
KPTLTP Wall Mounng bracket, free horizontal aiming
and 4 steps at 15° for vertical aiming, the
loudspeaker can be mounted horizontally or
vercally.
PLH300 Ø 48-51mm truss tube aluminium coupler with
M12 x 50 built-in bolt and fastening nut.
NL4FX Neutrik Speakon® PLUG
see hp://www.axiomproaudio.com for detailed descripon and other available accessories.
SPARE PARTS
NL4MP Neutrik Speakon® panel socket 98DRI2065 1.4’’ - 2.4” VC compression driver - 8 ohm
91CR0072 ED120P Crossover PCBA 98MBN2065 tanium diaphragm for 1.4” driver
98ED120WZ8 12’’ woofer - 3” VC - 8 ohm
Wall
Adapter
36 cm
14.2"
31 cm
12.2"
61 cm
24"
Pole Adapter
M10 Flying Point
M10 Flying Point
M10 Flying Point
INSTRUCTION FOR ROTATING THE HORN
1) Remove the speaker grid unscrewing
the six screws indicated below.
turn
90°
2) Unscrew the 4 screws fixing the horn and
rotate the horn by 90°.
Aiming
Point

6
INPUT
Power input for the external amplier. The ED120P includes a passive crossover for ltering the signal,
it includes also an internal protecon that limit for excessive power on the HF secon and if the signal
persists for a long me period it excludes the HF secon. The connecons are the following:
INPUT - LINK
NL4 pin number internal connecon
1+ +
1- -
2+ none (pass thru)
2- none (pass thru)
LINK
Power output in parallel with the INPUT socket for connecng the unit to another speaker.
The number of ED120P cabinets that can be connected in parallel depends on the amplier load
capacity.
HORN ORIENTATION
For a correct horn orientaon see the following examples:
WARNING! CAREFULLY READ THE FOLLOWING INSTRUCTIONS AND CONDITION OF USE:
• For a supplementary safety assure always the loudspeaker to the wall with an alternave rope.
• This loudspeaker is designed exclusively for Professional audio applicaons. The product must be installed by qualied
personal only.
• Proel strongly recommends that this loudspeaker cabinet be suspended taking into consideraon all current Naonal,
Federal, State and Local regulaons. Please contact the manufacturer for further informaon.
• Proel do not accept any liability for damage caused to third pares due to improper installaon, lack of maintenance,
tampering or improper use of this product, including disregard of acceptable and applicable safety standards.
• During assembly pay aenon to the possible risk of crushing. Wear suitable protecve clothing. Observe all
instrucons given on the rigging components and the loudspeaker cabinets. When chain hoists are in operaon ensure
that there is nobody directly underneath or in the vicinity of the load. Do not under any circumstances climb on the array.
VERTICAL POSITION
FOH CONFIGURATION
HORIZONTAL POSITION
FOH CONFIGURATION
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
�ght dispersion
long throw
VERTICAL POSITION
FOH CONFIGURATION
�ght dispersion
long throw
VERTICAL POSITION
FOH CONFIGURATION
wide
dispersion
short throw
wide
dispersion
short throw
�ght
dispersion
long throw
HORIZONTAL POSITION
FOH CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
HORIZONTAL POSITION
FOH CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
�ght dispersion
long throw
wide dispersion
short throw
�ght
dispersion
long throw
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
wide dispersion
short throw
�ght dispersion
long throw
HORIZONTAL POSITION
STAGE MONITOR CONFIGURATION
wide
dispersion
short throw
wide
dispersion
short throw
�ght dispersion
long throw
wide
dispersion
short throw

7
KPTED120B WALL or TRUSS MOUNTING
Using the “C” shape bracket the ED120P loudspeaker can be mounted to walls or truss combining it with two PLH300:
It allows to aim the speaker in one direcon (vercal or horizontal) in 15 steps (0°, ±10°, ±15°, ±25°, ±30°, ±40°, ±55°, ±70°).
For installing the speaker using the “C” bracket follow these instrucons:
1) Install the “C” bracket to the the wall or to the truss.
2) Mount the two steering plates on the top and boom of the loudspeaker using the bolts (a).
3) Carefully put the loudspeaker into the “C” bracket then screw in the screws (b) to x it to the “C” bracket.
4) Aim the loudspeaker and ghten the screw-knobs (c) in the desired holes.
5) Tight the screws (b).
KPTLTP WALL MOUNTING
This wall mounng bracket allows to aim the loudspeaker in both horizontally and vercally. The horizontal aiming is free with
+/-15° and the vercal aiming is in 4 steps (0°,-15°,-30°,-45°), the loudspeaker can be mounted horizontally or vercally as in the
following gure.
a
a
a
b
b
4
c
c a
2
1
2
2
2
3
5

PROEL S.p.A. (World Headquarters) - Via alla Ruenia 37/43 - 64027 Sant’Omero (Te) - ITALY
Tel: +39 0861 81241 Fax: +39 0861 887862 www.axiomproaudio.com
Table of contents
Other Axiom Speakers manuals

Axiom
Axiom Architectural W2 User manual

Axiom
Axiom ED120P User manual

Axiom
Axiom Millennia M2 Technical manual

Axiom
Axiom FMS 16/24 Specification sheet

Axiom
Axiom VP100 v2 User manual

Axiom
Axiom LFR1100 User manual

Axiom
Axiom QUADPOLAR QS8 v3 User manual

Axiom
Axiom W2 Specification sheet

Axiom
Axiom T2 User manual

Axiom
Axiom Axiom VP150 User manual